Shunsuke Ohnishi
Beth Israel Deaconess Medical Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Shunsuke Ohnishi.
Molecular Imaging | 2005
Shunsuke Ohnishi; Stephen Johnson Lomnes; Rita G. Laurence; Andrew Gogbashian; Giuliano Mariani; John V. Frangioni
Intraoperative near-infrared (NIR) fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs) for sentinel lymph node (SLN) mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800), emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.
Journal of Biomedical Optics | 2006
Alec M. De Grand; Stephen Johnson Lomnes; Deborah S. Lee; Matthew Pietrzykowski; Shunsuke Ohnishi; Timothy G. Morgan; Andrew Gogbashian; Rita G. Laurence; John V. Frangioni
We demonstrate how to construct calibrated, stable, and inexpensive tissue-like phantoms for near-IR (NIR) fluorescence imaging applications. The bulk phantom material is composed of gelatin, intralipid, hemoglobin, and indocyanine green (ICG). Absorbance, scatter, background fluorescence, and texture can be tuned as desired. NIR fluorescent inclusions are comprised of ICG-labeled polystyrene divinylbenzene beads and Pam78-labeled hydroxyapatite crystals. The former mimic tumor masses of controllable size and contrast agent concentration, and the latter mimic microcalcifications in breast cancer. NIR-fluorescent inclusions can be positioned precisely in phantoms, with one or more regions having different optical properties, and their position can be verified independently using microcomputed tomography. We demonstrate how these phantoms can be used to calibrate and compare imaging systems, and to train surgeons to operate under NIR fluorescence image guidance.
Annals of Surgical Oncology | 2007
Cherie P. Parungo; David I. Soybel; Yolonda L. Colson; Sang-Wook Kim; Shunsuke Ohnishi; Alec M. De Grand; Rita G. Laurence; Edward G. Soltesz; Fredrick Y. Chen; Lawrence H. Cohn; Moungi G. Bawendi; John V. Frangioni
BackgroundUnderstanding lymph drainage patterns of the peritoneum could assist in staging and treatment of gastrointestinal and ovarian malignancies. Sentinel lymph nodes (SLNs) have been identified for solid organs and the pleural space. Our purpose was to determine whether the peritoneal space has a predictable lymph node drainage pattern.MethodsRats received intraperitoneal injections of near-infrared (NIR) fluorescent tracers: namely, quantum dots (designed for retention in SLNs) or human serum albumin conjugated with IRDye800 (HSA800; designed for lymphatic flow beyond the SLN). A custom imaging system detected NIR fluorescence at 10 and 20 minutes and 1, 4, and 24 hours after injection. To determine the contribution of viscera to peritoneal lymphatic flow, additional cohorts received bowel resection before NIR tracer injection. Associations with appropriate controls were assessed with the χ2 test.ResultsQuantum dots drained to the celiac, superior mesenteric, and periportal lymph node groups. HSA800 drained to these same groups at early time points but continued flowing to the mediastinal lymph nodes via the thoracic duct. After bowel resection, both tracers were found in the thoracic, not abdominal, lymph node groups. Additionally, HSA800 was no longer found in the thoracic duct but in the anterior chest wall and diaphragmatic lymphatics.ConclusionsThe peritoneal space drains to the celiac, superior mesenteric, and periportal lymph node groups first. Lymph continues via the thoracic duct to the mediastinal lymph nodes. Bowel lymphatics are a key determinant of peritoneal lymph flow, because bowel resection shifts lymph flow directly to the intrathoracic lymph nodes via chest wall lymphatics.
Methods of Molecular Biology | 2007
John V. Frangioni; Sang-Wook Kim; Shunsuke Ohnishi; Sungjee Kim; Moungi G. Bawendi
Sentinel lymph node (SLN) mapping is an important cancer surgery during which the first lymph node draining the site of a tumor is identified, resected, and analyzed for the presence or absence of malignant cells. Fluorescent semiconductor nanocrystals (quantum dots [QDs]) of the appropriate size, charge, and emission wavelength permit this surgery to be performed rapidly, with high sensitivity and under complete image guidance. We describe the materials and methods necessary for the production and characterization of type-II near-infrared fluorescent QDs, which have been optimized for SLN mapping. They contain a CdTe core, CdSe shell, and a highly anionic, oligomeric phosphine organic coating. We also describe how to utilize such QDs in animal model systems of SLN mapping.
Molecular Imaging | 2005
Valerie Humblet; Rena G. Lapidus; Larry R. Williams; Takashi Tsukamoto; Camilo Rojas; Pavel Majer; Bunda Hin; Shunsuke Ohnishi; Alec M. De Grand; Atif Zaheer; Jürgen T. Renze; Akira Nakayama; Barbara S. Slusher; John V. Frangioni
Surgical resection remains a definitive treatment for prostate cancer. Yet, prostate cancer surgery is performed without image guidance for tumor margin, extension beyond the capsule and lymph node positivity, and without verification of other occult metastases in the surgical field. Recently, several imaging systems have been described that exploit near-infrared (NIR) fluorescent light for sensitive, real-time detection of disease pathology intraoperatively. In this study, we describe a high-affinity (9 nM), single nucleophile-containing, small molecule specific for the active site of the enzyme PSMA. We demonstrate production of a tetra-sulfonated heptamethine indocyanine NIR fluorescent derivative of this molecule using a high-yield LC/MS purification strategy. Interestingly, NIR fluorophore conjugation improves affinity over 20-fold, and we provide mechanistic insight into this observation. We describe the preparative production of enzymatically active PSMA using a baculovirus expression system and an adenovirus that co-expresses PSMA and GFP. We demonstrate sensitive and specific in vitro imaging of endogenous and ectopically expressed PSMA in human cells and in vivo imaging of xenograft tumors. We also discuss chemical strategies for improving performance even further. Taken together, this study describes nearly complete preclinical development of an optically based small-molecule contrast agent for image-guided surgery.
Surgery | 2008
Eiichi Tanaka; Hak Soo Choi; Valerie Humblet; Shunsuke Ohnishi; Rita G. Laurence; John V. Frangioni
BACKGROUND Currently, only x-ray fluoroscopy is available for visualization of the extrahepatic bile ducts intraoperatively. We hypothesized that with an appropriate fluorophore and imaging system, invisible near-infrared (NIR) light could be used for image-guided procedures on the extrahepatic bile ducts. METHODS We quantified the performance of three 800 nm NIR fluorophores, differing primarily in their degree of hydrophilicity, for real-time imaging of the extrahepatic bile ducts in rats and pigs: IR-786, indocyanine green (ICG), and the carboxylic form of IRDyetrade mark 800CW (CW800-CA). The signal-to-background ratio (SBR) of the common bile duct relative to liver and pancreas was measured as a function of the dose of contrast agent, injection site, and kinetics using an intraoperative NIR fluorescence imaging system described previously. Bile samples were examined by high performance liquid chromatography tandem mass spectrometry (HPLC/MS) to determine the chemical form of fluorophores in bile. RESULTS Non-sulfonated (IR-786) and di-sulfonated (ICG) NIR fluorophores had poor efficiency and kinetics of excretion into bile. Tetra-sulfonated CW800-CA, however, provided sensitive, specific, and real-time visualization of the extrahepatic bile ducts after a single low-dose given either intraportally or intravenously via systemic vein. A SBR >/=2 provided sensitive assessment of extrahepatic bile duct anatomy and function for over 30 min post-injection, including the detection of millimeter-sized, radiolucent inclusions in pigs. CW800-CA remained intact chemically after secretion into bile. CONCLUSION The combination of invisible NIR light and an IV injection of CW800-CA provides prolonged, real-time visualization of the extrahepatic bile duct, without ionizing radiation and without changing the look of the operative field.
Annals of Surgical Oncology | 2004
Cherie P. Parungo; Shunsuke Ohnishi; Alec M. De Grand; Rita G. Laurence; Edward G. Soltesz; Yolonda L. Colson; Peter M. Kang; Tomislav Mihaljevic; Lawrence H. Cohn; John V. Frangioni
AbstractBackground: Understanding the spatial and temporal drainage patterns of the pleural space could have profound impact on the treatment of lung cancer and mesothelioma. The purpose of this study was to identify the in vivo pattern of drainage from the pleural space to prognostic lymph node stations. Methods: Fifty-six rats underwent pleural space injection of a novel lymph tracer composed of recombinant human serum albumin (HSA) covalently conjugated to the near-infrared (NIR) fluorophore IRDye78 via an amide bond (HSA-78). Nodal uptake was imaged at 10, 20, 30, and 60 minutes and 4, 12, and 24 hours after injection with a custom system that simultaneously acquires color video, NIR fluorescence of HSA-78, and a merged picture of the two. Six pigs underwent the same procedure with imaging at 30 minutes, 1 hour, and 24 hours. Results: In both the rat model and the pig model, HSA-78 drained from the pleural space to superior mediastinal lymph nodes first, followed by other intrathoracic and then extrathoracic lymph nodes over the course of 24 hours. Conclusion: NIR fluorescence imaging in two species shows that the superior mediastinal lymph nodes are the first to drain the pleural space. Over the course of 24 hours, the pleural space also communicates with other intrathoracic and then extrathoracic lymph nodes. This study also demonstrates an intraoperative method for identifying nodes communicating with the pleural space, with potential utility in the staging and/or resection of lung cancer and mesothelioma.
American Journal of Transplantation | 2006
Shunsuke Ohnishi; J.-L. Vanderheyden; Eichii Tanaka; B. Patel; A. M. De Grand; Rita G. Laurence; K. Yamashita; John V. Frangioni
The intraoperative detection of cell injury and cell death is fundamental to human surgeries such as organ transplantation and resection. Because of low autofluorescence background and relatively high tissue penetration, invisible light in the 800 nm region provides sensitive detection of disease pathology without changing the appearance of the surgical field. In order to provide surgeons with real‐time intraoperative detection of cell injury and death after ischemia/reperfusion (I/R), we have developed a bioactive derivative of human annexin V (annexin800), which fluoresces at 800 nm. Total fluorescence yield, as a function of bioactivity, was optimized in vitro, and final performance was assessed in vivo. In liver, intestine and heart animal models of I/R, an optimal signal to background ratio was obtained 30 min after intravenous injection of annexin800, and histology confirmed concordance between planar reflectance images and actual deep tissue injury. In summary, annexin800 permits sensitive, real‐time detection of cell injury and cell death after I/R in the intraoperative setting, and can be used during a variety of surgeries for rapid assessment of tissue and organ status.
Journal of the American Chemical Society | 2006
John P. Zimmer; Sang-Wook Kim; Shunsuke Ohnishi; Eichii Tanaka; John V. Frangioni; Moungi G. Bawendi
Journal of the American Chemical Society | 2005
Sang-Wook Kim; John P. Zimmer; Shunsuke Ohnishi; Joseph B. Tracy; John V. Frangioni; Moungi G. Bawendi