Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Shyh-Liang Lou is active.

Publication


Featured researches published by Shyh-Liang Lou.


Talanta | 2010

Flexible thick-film glucose biosensor: Influence of mechanical bending on the performance

Min-Chieh Chuang; Yang-Li Yang; Ta-Feng Tseng; Tzu‐Yang Chou; Shyh-Liang Lou; Joseph Wang

The influence of the bending-induced mechanical stress of flexible Nafion/GOx/carbon screen-printed electrodes (SPEs) upon the performance of such glucose biosensors has been examined. Surprisingly, such flexible enzyme/polymer-SPEs operate well following a severe bending-induced mechanical stress (including a 180 degrees pinch), and actually display a substantial sensitivity enhancement following their mechanical bending. The bending-induced sensitivity enhancement is observed only for the amperometric detection of the glucose substrate but not for measurements of hydrogen peroxide, catechol or ferrocyanide at coated or bare SPEs. These (and additional) data indicate that the bending effect is associated primarily with changes in the biocatalytic activity. Such sensitivity enhancement is more pronounced at elevated glucose levels, reflecting the bending-induced changes in the biocatalytic reaction. Factors affecting the bending-induced changes in the performance are examined. While our data clearly indicate that flexible enzyme/polymer-SPEs can tolerate a severe mechanical stress and hold promise as wearable glucose biosensors, delivering the sample to the active sensor surface remains the major challenge for such continuous health monitoring.


international conference of the ieee engineering in medicine and biology society | 2008

A miniaturized glucose biosensor for in vitro and in vivo studies

Yang-Li Yang; Jian-Feng Huang; Ta-Feng Tseng; Chia-Ching Lin; Shyh-Liang Lou

A miniaturized wireless glucose biosensor has been developed to perform in vitro and in vivo studies. It consists of an external control subsystem and an implant sensing subsystem. The implant subsystem consists of a micro-processor, which coordinates circuitries of radio frequency, power regulator, command demodulator, glucose sensing trigger and signal read-out. Except for a set of sensing electrodes, the micro-processor, the circuitries and a receiving coil were hermetically sealed with polydimethylsiloxane. The electrode set is a substrate of silicon oxide coated with platinum, which includes a working electrode and a reference electrode. Glucose oxidase was immobilized on the surface of the working electrode. The implant subsystem bi-directionally communicates with the external subsystem via radio frequency technologies. The external subsystem wirelessly supplies electricity to power the implant, issues commands to the implant to perform tasks, receives the glucose responses detected by the electrode, and relays the response signals to a computer through a RS-232 connection. Studies of in vitro and in vivo were performed to evaluate the biosensor. The linear response of the biosensor is up to 15 mM of glucose in vitro. The results of in vivo study show significant glucose variations measured from the interstitial tissue fluid of a diabetes rat in fasting and non-fasting periods.


Sensors | 2010

Effects of Electric Potential Treatment of a Chromium Hexacyanoferrate Modified Biosensor Based on PQQ-Dependent Glucose Dehydrogenase

Ta-Feng Tseng; Yang-Li Yang; Yuh-Jiuan Lin; Shyh-Liang Lou

A novel potential treatment technique applied to a glucose biosensor that is based on pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase (GDH) and chromium hexacyanoferrate (CrHCF) incorporated into a platinum (Pt) electrode was demonstrated. CrHCF, serving as a mediator, was electrochemically deposited on the Pt electrode as ascertained by CV, SEM, FTIR and XPS measurements. The potential treatment of CrHCF, which converts Fe(II) to Fe(III), enables the glucose detection. The amperometric measurement linearity of the biosensor was up to 20 mM (R = 0.9923), and the detection sensitivity was 199.94 nA/mM per cm2. More importantly, this biosensor remained stable for >270 days.


international conference of the ieee engineering in medicine and biology society | 2007

Using MPTMS as Permselective Membranes of Biosensors

Yang-Li Yang; Ta-Feng Tseng; Shyh-Liang Lou

A sol-gel material of (3-mercaptopropyl)trimethoxysilane (MPTMS) is proposed to function as permselective membranes of biosensors. Permselectivity of MPTMS and Nafionreg was compared by studying their anti-interferent ability. Membrane porosity of MPTMS and Nafionreg was first confirmed via voltammetric responses in ferrocynite/ferricynite solution. In the comparison studies, membranes prepared with 20% MPTMS in phosphate buffer solution (PBS) and 1% Nafionreg in 2-propanol (IPA) were used as coating materials on the surface of two platinum (Pt) electrodes. These electrodes were used to electrochemically measure the response currents of ascorbic acid, uric acid, and acetaminophen. The results indicate that the MPTMS-based electrode produced much less response currents from the interference species compared to that of the Nafionreg-based electrode. This denotes that the anti-interferent ability of MPTMS is superior to that of Nafionreg. A platinum working electrode containing glucose oxidase (GOx) immobilized by poly-aniline (PA) and then modified by MPTMS was developed and evaluated. The results show that the optimum applied potential for the glucose biosensor is 0.4 V. This operational potential not only inhibits the response currents from ascorbic acid, uric acid, and acetaminophen but also produces rather high signals for glucose.


international conference of the ieee engineering in medicine and biology society | 2007

Chromium hexacyanoferrate modified biosensor based on PQQ-dependent glucose dehydrogenase

Ta-Feng Tseng; Yang-Li Yang; Shyh-Liang Lou

A pyrroloquinoline quinone (PQQ)-dependent glucose dehydrogenase based platinum electrode was developed to detect glucose. Chromium hexacyanoferrate was modified onto this electrode to serve as an electron transfer mediator between PQQ and the platinum electrode. This biosensor showed the optimal response of glucose measurements at pH 7 and an operation potential of +0.4 V (vs. Ag/AgCl). More importantly the lifespan of the biosensor has been last for 47 days without significant enzyme activity degradation.


Analyst | 2010

Thick-film textile-based amperometric sensors and biosensors

Yang-Li Yang; Min-Chieh Chuang; Shyh-Liang Lou; Joseph Wang


Electrochemistry Communications | 2009

Thermally Stable Improved First-Generation Glucose Biosensors based on Nafion/Glucose-Oxidase Modified Heated Electrodes

Ta-Feng Tseng; Yang-Li Yang; Min-Chieh Chuang; Shyh-Liang Lou; Michal Galik; Gerd-Uwe Flechsig; Joseph Wang


Sensors and Actuators B-chemical | 2008

Performance characteristic studies of glucose biosensors modified by (3-mercaptopropyl)trimethoxysilane sol–gel and non-conducting polyaniline

Yang-Li Yang; Ta-Feng Tseng; Jui-Ming Yeh; Chien-An Chen; Shyh-Liang Lou


Archive | 2009

A nitrite biosensor based on hemoglobin immobilized with MPTMS

林政宏; Chen-Hung Lin; 曾達峰; Ta-Feng Tseng; 楊泱澧; Yang-Li Yang; 婁世亮; Shyh-Liang Lou


Archive | 2009

Implantable bio-sensing system

蔡瀚慶; Han-Ching Tsai; 林建廷; Jain-Ting Lin; 何依珊; I-shan Ho; 楊泱澧; Yang-Li Yang; 曾達峯; Ta-Feng Tseng; 婁世亮; Shyh-Liang Lou

Collaboration


Dive into the Shyh-Liang Lou's collaboration.

Top Co-Authors

Avatar

Yang-Li Yang

Chung Yuan Christian University

View shared research outputs
Top Co-Authors

Avatar

Ta-Feng Tseng

Chung Yuan Christian University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joseph Wang

University of California

View shared research outputs
Top Co-Authors

Avatar

Chia-Ching Lin

Chung Yuan Christian University

View shared research outputs
Top Co-Authors

Avatar

Chien-An Chen

Industrial Technology Research Institute

View shared research outputs
Top Co-Authors

Avatar

Jian-Feng Huang

Chung Yuan Christian University

View shared research outputs
Top Co-Authors

Avatar

Jui-Ming Yeh

Chung Yuan Christian University

View shared research outputs
Top Co-Authors

Avatar

Michal Galik

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge