Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sibylle Gröters is active.

Publication


Featured researches published by Sibylle Gröters.


Particle and Fibre Toxicology | 2013

Comparative inhalation toxicity of multi-wall carbon nanotubes, graphene, graphite nanoplatelets and low surface carbon black.

Lan Ma-Hock; Volker Strauss; Silke Treumann; Karin Küttler; Wendel Wohlleben; Thomas Hofmann; Sibylle Gröters; Karin Wiench; Bennard van Ravenzwaay; Robert Landsiedel

BackgroundCarbon nanotubes, graphene, graphite nanoplatelets and carbon black are seemingly chemically identical carbon-based nano-materials with broad technological applications. Carbon nanotubes and carbon black possess different inhalation toxicities, whereas little is known about graphene and graphite nanoplatelets.MethodsIn order to compare the inhalation toxicity of the mentioned carbon-based nanomaterials, male Wistar rats were exposed head-nose to atmospheres of the respective materials for 6xa0hours per day on 5 consecutive days. Target concentrations were 0.1, 0.5, or 2.5xa0mg/m3 for multi-wall carbon nanotubes and 0.5, 2.5, or 10xa0mg/m3 for graphene, graphite nanoplatelets and low-surface carbon black. Toxicity was determined after end of exposure and after three-week recovery using broncho-alveolar lavage fluid and microscopic examinations of the entire respiratory tract.ResultsNo adverse effects were observed after inhalation exposure to 10xa0mg/m3 graphite nanoplatelets or relatively low specific surface area carbon black. Increases of lavage markers indicative for inflammatory processes started at exposure concentration of 0.5xa0mg/m3 for multi-wall carbon nanotubes and 10xa0mg/m3 for graphene. Consistent with the changes in lavage fluid, microgranulomas were observed at 2.5xa0mg/m3 multi-wall carbon nanotubes and 10xa0mg/m3 graphene. In order to evaluate volumetric loading of the lung as the key parameter driving the toxicity, deposited particle volume was calculated, taking into account different methods to determine the agglomerate density. However, the calculated volumetric load did not correlate to the toxicity, nor did the particle surface burden of the lung.ConclusionsThe inhalation toxicity of the investigated carbon-based materials is likely to be a complex interaction of several parameters. Until the properties which govern the toxicity are identified, testing by short-term inhalation is the best option to identify hazardous properties in order to avoid unsafe applications or select safer alternatives for a given application.


Particle and Fibre Toxicology | 2014

Application of short-term inhalation studies to assess the inhalation toxicity of nanomaterials

Robert Landsiedel; Lan Ma-Hock; Thomas Hofmann; Martin Wiemann; Volker Strauss; Silke Treumann; Wendel Wohlleben; Sibylle Gröters; Karin Wiench; Bennard van Ravenzwaay

BackgroundA standard short-term inhalation study (STIS) was applied for hazard assessment of 13 metal oxide nanomaterials and micron-scale zinc oxide.MethodsRats were exposed to test material aerosols (ranging from 0.5 to 50 mg/m3) for five consecutive days with 14- or 21-day post-exposure observation. Bronchoalveolar lavage fluid (BALF) and histopathological sections of the entire respiratory tract were examined. Pulmonary deposition and clearance and test material translocation into extra-pulmonary organs were assessed.ResultsInhaled nanomaterials were found in the lung, in alveolar macrophages, and in the draining lymph nodes. Polyacrylate-coated silica was also found in the spleen, and both zinc oxides elicited olfactory epithelium necrosis. None of the other nanomaterials was recorded in extra-pulmonary organs. Eight nanomaterials did not elicit pulmonary effects, and their no observed adverse effect concentrations (NOAECs) were at least 10 mg/m3. Five materials (coated nano-TiO2, both ZnO, both CeO2) evoked concentration-dependent transient pulmonary inflammation. Most effects were at least partially reversible during the post-exposure period.Based on the NOAECs that were derived from quantitative parameters, with BALF polymorphonuclear (PMN) neutrophil counts and total protein concentration being most sensitive, or from the severity of histopathological findings, the materials were ranked by increasing toxic potency into 3 grades: lower toxic potency: BaSO4; SiO2.acrylate (by local NOAEC); SiO2.PEG; SiO2.phosphate; SiO2.amino; nano-ZrO2; ZrO2.TODA; ZrO2.acrylate; medium toxic potency: SiO2.naked; higher toxic potency: coated nano-TiO2; nano-CeO2; Al-doped nano-CeO2; micron-scale ZnO; coated nano-ZnO (and SiO2.acrylate by systemic no observed effect concentration (NOEC)).ConclusionThe STIS revealed the type of effects of 13 nanomaterials, and micron-scale ZnO, information on their toxic potency, and the location and reversibility of effects. Assessment of lung burden and material translocation provided preliminary biokinetic information. Based upon the study results, the STIS protocol was re-assessed and preliminary suggestions regarding the grouping of nanomaterials for safety assessment were spelled out.


Mutation Research-genetic Toxicology and Environmental Mutagenesis | 2012

Investigation on the genotoxicity of different sizes of gold nanoparticles administered to the lungs of rats.

Markus Schulz; Lan Ma-Hock; Sandra Brill; Volker Strauss; Silke Treumann; Sibylle Gröters; Bennard van Ravenzwaay; Robert Landsiedel

Nanomaterials are already used today and offer even greater use and benefits in the future. The progress of nanotechnology must be accompanied by investigations of their potential harmful effects. For airborne nanomaterials, lung toxicity is a major concern and obviously the particle size is discussed as a critical property directing adverse effects. While standard toxicological test methods are generally capable of detecting the toxic effects, the choice of relevant methods for nanomaterials is still discussed. We have investigated two genotoxic endpoints - alkaline Comet assay in lung tissue and micronucleation in polychromatic erythrocytes of the bone marrow - in a combined study 72 h after a single instillation of 18 μg gold nanoparticles (NP) into the trachea of male adult Wistar rats. The administration of three test materials differing only in their primary particle size (2, 20 and 200 nm) did not lead to relevant DNA damage in the mentioned tests. The measurement of clinical pathology parameters in bronchoalveolar lavage fluid (BALF) and blood indicated neither relevant local reactions in the animals lungs nor adverse systemic effects. Minor histopathology findings occurred in the lung of the animals exposed to 20 nm and 200 nm sized nanomaterials. In conclusion, under the conditions of this study the different sized gold NP tested were non-genotoxic and showed no systemic and local adverse effects at the given dose.


Archives of Toxicology | 2014

Time course of lung retention and toxicity of inhaled particles: short-term exposure to nano-Ceria

Jana Keller; Wendel Wohlleben; Lan Ma-Hock; Volker Strauss; Sibylle Gröters; Karin Küttler; Karin Wiench; Christiane Herden; Günter Oberdörster; Bennard van Ravenzwaay; Robert Landsiedel

AbstractnTwo Ceria nanomaterials (NM-211 and NM-212) were tested for inhalation toxicity and organ burdens in order to design a chronic and carcinogenicity inhalation study (OECD TG No. 453). Rats inhaled aerosol concentrations of 0.5, 5, and 25xa0mg/m3 by whole-body exposure for 6xa0h/day on 5 consecutive days for 1 or 4xa0weeks with a post-exposure period of 24 or 129xa0days, respectively. Lungs were examined by bronchoalveolar lavage and histopathology. Inhaled Ceria is deposited in the lung and cleared with a half-time of 40xa0days; at aerosol concentrations higher than 0.5xa0mg/m3, this clearance was impaired resulting in a half-time above 200xa0days (25xa0mg/m3). After 5xa0days, Ceria (>0.5xa0mg/m3) induced an early inflammatory reaction by increases of neutrophils in the lung which decreased with time, with sustained exposure, and also after the exposure was terminated (during the post-exposure period). The neutrophil number observed in bronchoalveolar lavage fluid (BALF) was decreasing and supplemented by mononuclear cells, especially macrophages which were visible in histopathology but not in BALF. Further progression to granulomatous inflammation was observed 4xa0weeks post-exposure. The surface area of the particles provided a dose metrics with the best correlation of the two Ceria’s inflammatory responses; hence, the inflammation appears to be directed by the particle surface rather than mass or volume in the lung. Observing the time course of lung burden and inflammation, it appears that the dose rate of particle deposition drove an initial inflammatory reaction by neutrophils. The later phase (after 4xa0weeks) was dominated by mononuclear cells, especially macrophages. The progression toward the subsequent granulomatous reaction was driven by the duration and amount of the particles in the lung. The further progression of the biological response will be determined in the ongoing long-term study.


Toxicology and Applied Pharmacology | 2014

Applicability of rat precision-cut lung slices in evaluating nanomaterial cytotoxicity, apoptosis, oxidative stress, and inflammation

Ursula G. Sauer; Sandra Vogel; Alexandra Aumann; Annemarie Hess; Susanne N. Kolle; Lan Ma-Hock; Wendel Wohlleben; Martina Dammann; Volker Strauss; Silke Treumann; Sibylle Gröters; Karin Wiench; Bennard van Ravenzwaay; Robert Landsiedel

The applicability of rat precision-cut lung slices (PCLuS) in detecting nanomaterial (NM) toxicity to the respiratory tract was investigated evaluating sixteen OECD reference NMs (TiO₂, ZnO, CeO₂, SiO₂, Ag, multi-walled carbon nanotubes (MWCNTs)). Upon 24-hour test substance exposure, the PCLuS system was able to detect early events of NM toxicity: total protein, reduction in mitochondrial activity, caspase-3/-7 activation, glutathione depletion/increase, cytokine induction, and histopathological evaluation. Ion shedding NMS (ZnO and Ag) induced severe tissue destruction detected by the loss of total protein. Two anatase TiO₂ NMs, CeO₂ NMs, and two MWCNT caused significant (determined by trend analysis) cytotoxicity in the WST-1 assay. At non-cytotoxic concentrations, different TiO₂ NMs and one MWCNT increased GSH levels, presumably a defense response to reactive oxygen species, and these substances further induced a variety of cytokines. One of the SiO₂ NMs increased caspase-3/-7 activities at non-cytotoxic levels, and one rutile TiO₂ only induced cytokines. Investigating these effects is, however, not sufficient to predict apical effects found in vivo. Reproducibility of test substance measurements was not fully satisfactory, especially in the GSH and cytokine assays. Effects were frequently observed in negative controls pointing to tissue slice vulnerability even though prepared and handled with utmost care. Comparisons of the effects observed in the PCLuS to in vivo effects reveal some concordances for the metal oxide NMs, but less so for the MWCNT. The highest effective dosages, however, exceeded those reported for rat short-term inhalation studies. To become applicable for NM testing, the PCLuS system requires test protocol optimization.


Particle and Fibre Toxicology | 2014

Biokinetics and effects of barium sulfate nanoparticles

Nagarjun V. Konduru; Jana Keller; Lan Ma-Hock; Sibylle Gröters; Robert Landsiedel; Thomas C. Donaghey; Joseph D. Brain; Wendel Wohlleben; Ramon M. Molina

BackgroundNanoparticulate barium sulfate has potential novel applications and wide use in the polymer and paint industries. A short-term inhalation study on barium sulfate nanoparticles (BaSO4 NPs) was previously published [Part Fibre Toxicol 11:16, 2014]. We performed comprehensive biokinetic studies of 131BaSO4 NPs administered via different routes and of acute and subchronic pulmonary responses to instilled or inhaled BaSO4 in rats.MethodsWe compared the tissue distribution of 131Ba over 28 days after intratracheal (IT) instillation, and over 7 days after gavage and intravenous (IV) injection of 131BaSO4. Rats were exposed to 50 mg/m3 BaSO4 aerosol for 4 or 13 weeks (6 h/day, 5 consecutive days/week), and then gross and histopathologic, blood and bronchoalveolar lavage (BAL) fluid analyses were performed. BAL fluid from instilled rats was also analyzed.ResultsInhaled BaSO4 NPs showed no toxicity after 4-week exposure, but a slight neutrophil increase in BAL after 13-week exposure was observed. Lung burden of inhaled BaSO4 NPs after 4-week exposure (0.84 ± 0.18 mg/lung) decreased by 95% over 34 days. Instilled BaSO4 NPs caused dose-dependent inflammatory responses in the lungs. Instilled BaSO4 NPs (0.28 mg/lung) was cleared with a half-life of ≈ 9.6 days. Translocated 131Ba from the lungs was predominantly found in the bone (29%). Only 0.15% of gavaged dose was detected in all organs at 7 days. IV-injected 131BaSO4 NPs were predominantly localized in the liver, spleen, lungs and bone at 2 hours, but redistributed from the liver to bone over time. Fecal excretion was the dominant elimination pathway for all three routes of exposure.ConclusionsPulmonary exposure to instilled BaSO4 NPs caused dose-dependent lung injury and inflammation. Four-week and 13-week inhalation exposures to a high concentration (50 mg/m3) of BaSO4 NPs elicited minimal pulmonary response and no systemic effects. Instilled and inhaled BaSO4 NPs were cleared quickly yet resulted in higher tissue retention than when ingested. Particle dissolution is a likely mechanism. Injected BaSO4 NPs localized in the reticuloendothelial organs and redistributed to the bone over time. BaSO4 NP exhibited lower toxicity and biopersistence in the lungs compared to other poorly soluble NPs such as CeO2 and TiO2.


Toxicological Sciences | 2013

Additional Histopathologic Examination of the Lungs from a 3-Month Inhalation Toxicity Study with Multiwall Carbon Nanotubes in Rats

Silke Treumann; Lan Ma-Hock; Sibylle Gröters; Robert Landsiedel; Bennard van Ravenzwaay

For hazard assessment of multiwalled carbon nanotubes (MWCNTs), a 90-day inhalation toxicity study has been performed with Nanocyl NC 7000 in accordance with OECD 413 test guideline. MWCNTs produced no systemic toxicity. However, increased lung weights, multifocal granulomatous inflammation, diffuse histiocytic and neutrophilic infiltrates, and intra-alveolar lipoproteinosis were observed in lung and lung-associated lymph nodes at 0.5 and 2.5mg/m(3). Additional investigations of the lungs were performed, including special stains for examination of connective tissue, and electron microscopy was performed to determine the location of the MWCNTs. The alveolar walls revealed no increase of collagen fibers, whereas within the microgranulomas a slight increase of collagen fibers was observed. The pleura did not reveal any increase in collagen fibers. Only a slight increase in reticulin fibers in the alveolar walls in animals of the 0.5 and 2.5mg/m(3) concentration group was noted. In the 0.1mg/m(3) group, the only animal revealing minimal granulomas exhibited a minimal increase in collagen within the granuloma. No increase in reticulin was observed. Electron microscopy demonstrated entangled MWCNTs within alveolar macrophages. Occasionally electron dense particles/detritus were observed within membrane-bound vesicles (interpreted as phagosomes), which could represent degraded MWCNTs. If so, MWCNTs were degradable by alveolar macrophages and not persistent within the lung. Inhalation of MWCNTs caused granulomatous inflammation within the lung parenchyma but not the pleura in any of the concentration groups. Thus, there are some similarities to effects caused by inhaled asbestos, but the hallmark effects, namely pleural inflammation and/or fibrosis leading to mesotheliomas, are absent.


International Journal of Toxicology | 2012

Short-Term Rat Inhalation Study With Aerosols of Acrylic Ester-Based Polymer Dispersions Containing a Fraction of Nanoparticles

Lan Ma-Hock; Robert Landsiedel; Karin Wiench; Dominik Geiger; Volker Strauss; Sibylle Gröters; Bennard van Ravenzwaay; Matthias Gerst; Wendel Wohlleben; Gertrud Scherer

Aqueous polymer dispersions are important raw materials used in a variety of industrial processes. They may contain particles with diameters ranging from 10 to 1500 nm. Polymer exposure alone may cause pulmonary lesions after inhalation exposure. Polymer dispersions with increased proportions of nano-sized particles are being developed for improved material characteristics, and this may pose even increased pulmonary hazards upon potential inhalation exposure. In a 5-day screening study, male rats were nose-only exposed to aerosols generated from 2 dispersions of acrylic ester polymers with identical chemical composition but different nano-sized particle proportions at particle concentrations of 3 and 10 mg/m3. Immediately and 19 days after the end of inhalation, necropsies were conducted with major emphasis on respiratory tract histopathology. Three and 23 days after the end of inhalation, bronchoalveolar lavage was performed to screen for early pulmonary injury and inflammation. In contrast to the adverse effects known for other materials in short-term inhalation studies, none of the tested preparations of acrylic ester polymers elicited any adverse effect at the end of the inhalation or postinhalation periods. No shift in toxicity could be observed by the increased proportion of nano-sized polymer particles. Under the conditions of this study, the no observable adverse effect levels for both preparations were >10 mg/m3, that is 2- to 3-fold beyond current nuisance dust threshold limit values.


Toxicology Letters | 2014

Short term inhalation toxicity of a liquid aerosol of glutaraldehyde-coated CdS/Cd(OH)2 core shell quantum dots in rats

L. Ma-Hock; P.M.A. Farias; Thomas Hofmann; A.C.D.S. Andrade; J.N. Silva; T.M.S. Arnaud; Wolfgang Wohlleben; Verena Strauss; Silke Treumann; C.R. Chaves; Sibylle Gröters; Robert Landsiedel; B. van Ravenzwaay

Quantum dots exhibit extraordinary optical and mechanical properties, and the number of their applications is increasing. In order to investigate a possible effect of coating on the inhalation toxicity of previously tested non-coated CdS/Cd(OH)2 quantum dots and translocation of these very small particles from the lungs, rats were exposed to coated quantum dots or CdCl2 aerosol (since Cd(2+) was present as impurity), 6h/d for 5 consecutive days. Cd content was determined in organs and excreta after the end of exposure and three weeks thereafter. Toxicity was determined by examination of broncho-alveolar lavage fluid and microscopic evaluation of the entire respiratory tract. There was no evidence for translocation of particles from the respiratory tract. Evidence of a minimal inflammatory process was observed by examination of broncho-alveolar lavage fluid. Microscopically, minimal to mild epithelial alteration was seen in the larynx. The effects observed with coated quantum dots, non-coated quantum dots and CdCl2 were comparable, indicating that quantum dots elicited no significant effects beyond the toxicity of the Cd(2+) ion itself. Compared to other compounds with larger particle size tested at similarly low concentrations, quantum dots caused much less pronounced toxicological effects. Therefore, the present data show that small particle sizes with corresponding high surfaces are not the only factor triggering the toxic response or translocation.


Food and Chemical Toxicology | 2015

Safety assessment of [3S, 3′S]-astaxanthin – Subchronic toxicity study in rats

Roland Buesen; Stefan Schulte; V. Strauss; Silke Treumann; Matthias Becker; Sibylle Gröters; S. Carvalho; B. van Ravenzwaay

Astaxanthin, a naturally occurring xanthophyll, is commercially used as a coloring agent in salmon feed, but also marketed as a dietary supplement. The objective of this study was to investigate the subchronic toxicity of synthetic [3S, 3S]-Astaxanthin in rats. A powder formulation containing approximately 20% [3S, 3S]-Astaxanthin was administered via the diet to groups of 10 male and 10 female Wistar rats at concentrations of 5000, 15,000 and 50,000u2009ppm for a period of 13 weeks. A formulation of comparable composition but without [3S, 3S]-Astaxanthin served as a placebo control. There were no effects observed on survival, clinical examinations, clinical pathology, estrous cycle as well as on sperm parameters. At terminal necropsy, a macroscopically visible brown-blue discoloration of the gastrointestinal contents was noted which was considered to be secondary to the violet-brown color of the test material. No other significant or dose-related abnormalities were found in the tissues collected at termination. Our observations support that ingestion of [3S, 3S]-Astaxanthin of up to 700-920u2009mg/kg bw/day in rats in a gelatin/carbohydrate formulation is without adverse effects.

Collaboration


Dive into the Sibylle Gröters's collaboration.

Top Co-Authors

Avatar

Silke Treumann

Federal University of Pernambuco

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bennard van Ravenzwaay

Wageningen University and Research Centre

View shared research outputs
Top Co-Authors

Avatar

B. van Ravenzwaay

Federal University of Pernambuco

View shared research outputs
Top Co-Authors

Avatar

Thomas Hofmann

Federal University of Pernambuco

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge