Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Siegmar Blumentritt is active.

Publication


Featured researches published by Siegmar Blumentritt.


Gait & Posture | 2002

Energy expenditure and biomechanical characteristics of lower limb amputee gait:: The influence of prosthetic alignment and different prosthetic components

Thomas Schmalz; Siegmar Blumentritt; Rolf Jarasch

In this study, the influence of different prosthetic alignments and components on oxygen consumption and the important biomechanical characteristics of the normal gait pattern of leg amputees was investigated. With 15 transtibial and 12 transfemoral amputees, the oxygen consumption during walking on a treadmill was analyzed and biomechanical parameters during walking on even ground at a self-selected speed were defined. The amputation of all patients was caused by trauma. Variations of the prosthetic alignment affect the energy consumption of transfemoral amputees more significantly than that of transtibial amputees. Comparison of different prosthetic feet worn by transtibial amputees did not show significant differences regarding metabolic parameters. Compared with conventional hydraulic knee controls, the oxygen consumption of transfemoral amputees provided with an electronically controlled hydraulic knee joint is reduced. All investigated variations can be clearly characterized by the sagittal moments acting on the joints of the prosthetic limb during gait.


Archives of Physical Medicine and Rehabilitation | 2010

Comparative Biomechanical Analysis of Current Microprocessor-Controlled Prosthetic Knee Joints

Malte Bellmann; Thomas Schmalz; Siegmar Blumentritt

OBJECTIVE To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). DESIGN Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic camera system combined with 2 forceplates as well as a mobile spiroergometric system. SETTING The study was conducted in a gait laboratory. PARTICIPANTS Subjects with unilateral transfemoral amputations (N=9; mobility grade, 3-4; age, 22-49y) were tested. INTERVENTIONS Participants were fitted and tested with 4 different microprocessor-controlled knee joints. MAIN OUTCOME MEASURES Static prosthetic alignment, time distance parameters, kinematic and kinetic data and metabolic energy consumption. RESULTS Compared with the Hybrid Knee and the Adaptive 2, the C-Leg offers clear advantages in the provision of adequate swing phase flexion resistances and terminal extension damping during level walking at various speeds, especially at higher walking speeds. The Rheo Knee provides sufficient terminal extension; however, swing phase flexion resistances seem to be too low. The values for metabolic energy consumption show only slight differences during level walking. The joint resistances generated for descending stairs and ramps relieve the contralateral side to varying degrees. When walking on stairs, safety-relevant technical differences between the investigated joint types can be observed. Designs with adequate internal resistances offer stability advantages when the foot is positioned on the step. Stumble recovery tests reveal that the different knee joint designs vary in their effectiveness in preventing the patient from falling. CONCLUSIONS The patient benefits provided by the investigated electronic prosthetic knee joints differ considerably. The C-Leg appears to offer the amputee greater functional and safety-related advantages than the other tested knee joints. Reduced loading of the contralateral side has been demonstrated during ramp and stair descent. Metabolic energy consumption does not vary significantly between the tested knees. Hence, this parameter seems not to be a suitable criterion for assessing microprocessor-controlled knee components.


Jpo Journal of Prosthetics and Orthotics | 1997

design Principles, Biomechanical Data and Clinical Experience with a Polycentric Knee Offering Controlled Stance Phase Knee Flexion: A Preliminary Report

Siegmar Blumentritt; Hans Werner Scherer; Ulf Wellershaus; John W. Michael

The OTTO BOCK 3R60 prosthetic knee joint allows controlled flexion of the prosthetic knee under weightbearing in early stance phase, more closely simulating this aspect of gait than was previously possible. As the amputee transfers weight onto the prosthesis in early stance phase, this knee gradually flexes up to 15 degrees, thereby cushioning the impact of weight acceptance.In contrast to all previous polycentric knees, stability of this new design is biomechanically increased by stance flexion, rendering a locking feature unnecessary. Clinically, the amputee perceives this prosthesis as stable and comfortable. The biomechanical features of this design concept, initial clinical observations and preliminary conclusions from laboratory gait analysis are summarized.


Archives of Physical Medicine and Rehabilitation | 2012

Immediate Effects of a New Microprocessor-Controlled Prosthetic Knee Joint: A Comparative Biomechanical Evaluation

Malte Bellmann; Thomas Schmalz; Eva Ludwigs; Siegmar Blumentritt

OBJECTIVE To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. DESIGN Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. SETTING Motion analysis laboratory. PARTICIPANTS Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. INTERVENTIONS Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. MAIN OUTCOME MEASURES Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. RESULTS After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. CONCLUSIONS In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and stairs.


Jpo Journal of Prosthetics and Orthotics | 1998

Transfemoral amputees walking on a rotary hydraulic prosthetic knee mechanism: A preliminary report

Siegmar Blumentritt; Hans Werner Scherer; John W. Michael; Thomas Schmalz

Results from multiple instrumented gait analysis trials of seven traumatic transfemoral amputees capable of community ambulation are reviewed. All subjects used a novel rotary hydraulic prosthetic knee offering both stance and swing phase control, in combination with various contemporary prosthetic ankle-foot mechanisms. Unlike previous hydraulic stance and swing units, the Otto Bock 3R80 knee provides stance stability whenever the desired weightbearing load is applied to the prosthesis The mechanical principles and basic functions of the knee joint are described. Results from three phases of gait studies are presented to identify inter-individual variability and the effect of varying sagittal plane knee alignment and the ankle-foot mechanism selected. Subjective amputee preferences for specific foot devices are presented The pattern of hip moments on the amputated side during stance phase are characteristic of the individual amputee. However, the magnitude and timing of the hip moments vary considerably between individual amputees. So long as the prosthetic knee remains biomechanically stable, it appears that alignment alterations or the use of varying foot devices have little impact on the hip extension moment. On the other hand, the hip flexion effort required for the amputee to initiate knee flexion in late stance phase is directly related to the linear position of the prosthetic knee in the sagittal plane: the more posterior the knee, the greater the effort needed to begin swing phase Clinical function of this hydraulic prosthetic knee was considered satisfactory with all tested ankle-foot mechanisms. Transfemoral amputee preference for specific prosthetic feet in this study seemed to be determined by two biomechanical factors: (1) their ability to benefit from the use of a dynamic response foot without compensating with the non-amputated knee, and (2) their ability to generate a hip extension moment on the prosthetic side during the weight acceptance phase of gait


Biomedizinische Technik | 2012

Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint.

Malte Bellmann; Thomas Schmalz; Eva Ludwigs; Siegmar Blumentritt

Abstract Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.


Prosthetics and Orthotics International | 2010

Biomechanical Differences between Two Exoprosthetic Hip Joint Systems during Level Walking

Eva Ludwigs; Malte Bellmann; Thomas Schmalz; Siegmar Blumentritt

Previous studies have shown low end-user acceptance of a hip disarticulation style prosthesis and that the limitations of such prostheses, including poor gait pattern, socket discomfort, weight of the prosthesis, loss of mobility, instability and high energy consumption are a contributing factor. This study was initiated to determine if a new style of prosthetic hip joint could help to overcome some of the limitations concerning the gait pattern. The present study analyzed the gait pattern of six hip disarticulation amputee subjects. The objective was to compare two different prosthetic hip joints, both from Otto Bock HealthCare: The new Helix3D and the 7E7, which is based on the Canadian model proposed by McLaurin (1954). Kinematics and kinetics were recorded by an optoelectronic camera system with six CCD cameras and two force plates. During weight acceptance, the Helix3D extends considerably slower and reaches full extension later than the 7E7. The increased range of pelvic tilt observed with hip disarticulation amputees is significantly reduced (by 5 ± 3 degrees) when using the Helix3D Hip Joint. In addition, this system showed increased stance phase knee joint flexion as well as increased maximum swing phase knee flexion angles compared to the 7E7. These motion analysis results show that the Helix3D Hip Joint can reduce gait abnormalities compared to the uniplanar design of the 7E7 hip joint.


Jpo Journal of Prosthetics and Orthotics | 2014

Effects of Adaptation to a Functionally New Prosthetic Lower-Limb Component: Results of Biomechanical Tests Immediately after Fitting and after 3 Months of Use

Thomas Schmalz; Malte Bellmann; Eva Proebsting; Siegmar Blumentritt

ABSTRACT Ten established transfemoral amputees completed biomechanical tests after they had been fitted with a new prosthetic knee joint (test sessions: a few hours and 3 months after fitting). The required adaptation phase after fitting of a new prosthesis is frequently discussed. This phase is considered to be completed when the test result is no longer influenced by the patients’ learning processes. The study contributes to the understanding of the adaptation effects experienced prosthesis users require to master various motion patterns after being fitted with functionally new prosthetic knee joints. Biomechanical parameters (ground reaction forces, joint moments, and joint angles at the knee and the hip) were measured for level walking as well as ascending and descending ramps and stairs. For level walking, walking on ramps, and descending stairs, relevant differences in the parameters between the two tests could not be identified. For ascending stairs, the results of both tests showed obvious differences. The functions of a newly fitted prosthetic component can be intuitively used after a few hours of adaptation time if the motion patterns required are similar to that of the previous fitting. If specific functions require the learning of a motion, the learning processes will require a longer adaptation period.


Gait & Posture | 2007

Biomechanical analysis of stair ambulation in lower limb amputees.

Thomas Schmalz; Siegmar Blumentritt; Björn Marx


Clinical Biomechanics | 2006

The influence of sole wedges on frontal plane knee kinetics, in isolation and in combination with representative rigid and semi-rigid ankle-foot-orthoses.

Thomas Schmalz; Siegmar Blumentritt; Heiko Drewitz; Marie Freslier

Collaboration


Dive into the Siegmar Blumentritt's collaboration.

Top Co-Authors

Avatar

Thomas Schmalz

University of Göttingen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Björn Marx

University of Göttingen

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alli Gokeler

University Medical Center Groningen

View shared research outputs
Researchain Logo
Decentralizing Knowledge