Simon Herbert Schramm
General Electric
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Simon Herbert Schramm.
IEEE Transactions on Power Electronics | 2010
Simon Herbert Schramm; Christof Martin Sihler; Joseph Song-Manguelle; Paola Rotondo
Current source thyristor converters are the most widespread technology for large drives, and today still a suitable choice for supplying high-power variable speed drives because of excellent reliability records. The integer and noninteger harmonics generated by line-commutated converters cause pulsating torque harmonics on the motor and on the grid side of the converter. Intersections of harmonic excitation frequencies with torsional natural frequencies of mechanical drive trains (motor-driven load or generator train) cannot always be avoided in the operating-speed range of the motor. Continuously generated harmonic torque excitations could have a critical impact on the torsional behavior of the entire train. It is therefore mandatory to perform torsional analyses during the design stage of large drives, as specified in API 617 [1] to avoid torsional interaction issues. In multiunit plants, more sophisticated analyses have to be performed, considering the fully coupled electrical and mechanical system. The risk for operational problems increases with increasing percentage of converter loads (converter power relative to the short circuit level of the grid). Some oil and gas production sites, e.g., offshore platforms, are based on island or island-like power systems. To mitigate the risk of torsional issues with increasing percentage of converter loads in weak power systems, new devices for damping torsional resonance modes have been developed and successfully tested. The effect of torsional mode damping will be explained by coupled electromechanical simulations and by measurement results from applying an integrated torsional mode damper (TMD) to a 30 MW gas compression train. The TMD does not require changes to the mechanical or electrical system design and can be designed as a retrofit control system extension for variable speed drives from different manufacturers.
Archive | 2009
Christof Martin Sihler; Simon Herbert Schramm; Joseph Song-Manguelle; Paola Rotondo; Stefano Del-Puglia; Einar Vaughn Larsen
The oil and gas industry has a growing demand for electrically driven trains operated at variable speeds. Variable frequency electrical drives enable increased operational flexibility and energy efficiency. This is of great importance in applications requiring high power, such as gas compression. Load commutated inverters (LCIs) are one of the most widespread technologies for driving large gas compression trains because of excellent reliability records. One drawback of power electronics driven systems is the generation of nonfundamental air-gap torque ripple components due to electrical harmonics. The air-gap torque ripple can interact with the mechanical system at torsional natural frequencies of the drive train. Torsional vibration is an oscillatory angular motion that causes alternating twisting in shaft sections and machinery couplings. A consequence of uncontrolled excited torsional vibration may be a protective trip of the motor, to prevent mechanical damage, such as a failed coupling or a broken shaft. This paper discusses illustrative design details of applying a torsional mode damping control system to LCI driven multi-Megawatt centrifugal gas compressors. The coincidence of electrical drive harmonics and torsional natural frequencies of the mechanical system is sometimes unavoidable due to the large variable speed range of the compressor such as for process requirements. For these types of applications, a power electronic damping system technology can be applied to new units or as a retrofit solution to existing variable speed trains. The so-called integrated torsional mode damping (ITMD) unit is based on a torsional vibration measurement in the mechanical system and an interface to the existing inverter control of the drive system. The dc-link inductor of the LCI is partially used as an integrated energy storage unit and is combined with a smart damping controller, which reacts to a torsional vibration by modulating a small amount of the stored energy and sending it to the motor without impacting the normal operation of the system. As a result, the active power modulation at a torsional natural frequency of the mechanical system has a strong damping effect for torsional vibrations. Intensive simulations and several tests were performed on large LCIs (up to 50 MW) over the last three years. Selected experimental results will be presented and discussed to validate the suggested
IEEE Transactions on Industry Applications | 2011
Joseph Song-Manguelle; Christof Martin Sihler; Simon Herbert Schramm
In large-drive applications, load-commutated inverters (LCIs) are one of the most used technologies mainly because of their excellent reliability records. However, LCIs are known to generate interharmonics. They can interact with the mechanical system at torsional natural frequencies of the rotating train, on both the inverter and rectifier sides in weakly connected power systems, such as offshore oil and gas platforms. These interactions can lead to accelerated shaft fatigue, lifetime reduction, gear damage, and system blackouts. On the other hand, pulsewidth-modulated (PWM) voltage-source inverters (VSIs) are known to produce less torque ripple compared to LCIs. Consequently, VSIs are supposed to be less subject to exciting torsional resonances in mechanical shaft systems. Even with reduced torque ripple, mechanical failures have been consistently reported due to motor air-gap torques supplied by PWM drives. This paper is focused on solving torsional vibration issues. Due to system uncertainties, these issues cannot be excluded in the design phase of LCIs and VSIs for high-power applications. With regard to LCIs, the dc-link inductance is used as an integrated energy-storage unit. Motor and generator interactions are therefore decoupled. Excited eigenmodes on the grid side are damped with the rectifier; the inverter is driving the variable-speed motor. This approach is also successfully applied to damping resonance modes in the motor side. Simulation and selected experimental results on a 30-MW LCI system are provided to validate the proposed design approach. As for VSIs, a more general approach of damping or controlling excited shafts is proposed. This method is successfully applied using the dc-link capacitor as an integrated energy-storage source. This approach is used to optimize the design of new systems; otherwise, it is used to improve the performance of existing systems with minor modifications.
international power electronics and motion control conference | 2009
Simon Herbert Schramm; Christof Martin Sihler; Joseph Song-Manguelle; Paola Rotondo
Current source thyristor converters are the most widespread technology for large drives and today still a suitable choice for supplying high power variable speed drives for pumps and compressors because of excellent reliability records.
energy conversion congress and exposition | 2010
Joseph Song-Manguelle; Christof Martin Sihler; Simon Herbert Schramm
In large drive applications load-commutated inverters (LCIs) are one of the most used technologies, mainly because of their excellent reliability records. However, LCIs are known to generate interharmonics. They can interact with the mechanical system at torsional natural torsional frequencies of the rotating train, both on the inverter and on rectifier side in weakly connected power systems, such as offshore oil and gas platforms. These interactions can lead to accelerated shaft fatigue, lifetime reduction, gear damage and system blackouts.
european conference on cognitive ergonomics | 2014
Thiwanka Wijekoon; Eva-Maria Baerthlein; Ara Panosyan; Balusamy Kullampalayam Parameswaran; Simon Herbert Schramm; Stefan Schroeder
Integration of higher shares of solar and other renewable sources as well as use of heavy domestic loads in the distribution network and growing consumer acceptance of electric vehicles results in frequent voltage fluctuations in the grid leading to an increasing need for voltage regulation. An effective solution for voltage regulation in the distribution grid is the utilization of On-Load Tap Changers (OLTCs) with hybrid switches. Combination of semiconductor switches and no-load mechanical switches form a hybrid switch which can achieve arc free tap changing while the steady state power loss is kept at minimum. This paper describes the design, analysis and testing of semiconductor assisted OLTC used in the low voltage distribution network for series voltage regulation. Details of high current (1000A) hybrid switch using parallel connected low power MOSFETs and its related issues such as current sharing are discussed.
ASME 2011 Turbo Expo: Turbine Technical Conference and Exposition | 2011
Christof Martin Sihler; Simon Herbert Schramm; Valerio Rossi; Andrea Lenzi; Valerio Depau
The oil and gas industry has a growing demand for electrically driven trains operated at variable speeds. Variable frequency electrical drives enable increased operational flexibility and energy efficiency. One drawback of power electronics driven systems is the generation of non-fundamental air-gap torque ripple components due to electrical harmonics. The air-gap torque ripple can interact with the mechanical system at natural torsional frequencies of the drive train. Uncontrolled excited torsional vibration can silently lead to coupling failure due to fatigue. The coincidence of electrical drive harmonics and natural torsional frequencies of the mechanical system is sometimes unavoidable, due to the large variable speed range of the compressor as for process requirements. For those types of applications, a damping system utilizing available power electronics has been developed that can be applied to new units but also as a retrofit solution in existing variable speed trains. Electronic torsional vibration elimination (eTVe) is based on an angular vibration measurement in the mechanical system and an interface to the existing inverter control of the electrical drive. An important milestone of the eTVe development was achieved in 2010, in site testing this new solution to Liquid Natural Gas (LNG) production trains and demonstrating that it can completely eliminate torsional vibrations. With eTVe a residual torsional vibration level was achieved that was lower than the vibration level measured while the LNG train was only gas turbine driven. This torsional performance was achieved with a standard load commutated inverter drive (LCI). LCIs are one of the most widespread electrical drive technology for gas compression trains because of excellent reliability records, and it is the only one referenced solution for electric power larger than 45 MW.© 2011 ASME
Archive | 2009
Christof Martin Sihler; Jan Erich Hemmelmann; Simon Herbert Schramm
Archive | 2008
Christof Martin Sihler; Victor Donald Samper; Klaus Franz Otto Raum; Simon Herbert Schramm
Archive | 2007
Christof Martin Sihler; Alfredo Sebastian Achilles; Simon Herbert Schramm