Journal of Computer Assisted Tomography | 1992

Rapid automated algorithm for aligning and reslicing PET images

Roger P. Woods; Simon R. Cherry; John C. Mazziotta

A computer algorithm for the three-dimensional (3D) alignment of PET images is described. To align two images, the algorithm calculates the ratio of one image to the other on a voxel-by-voxel basis and then iteratively moves the images relative to one another to minimize the variance of this ratio across voxels. Since the method relies on anatomic information in the images rather than on external fiducial markers, it can be applied retrospectively. Validation studies using a 3D brain phantom show that the algorithm aligns images acquired at a wide variety of positions with maximum positional errors that are usually less than the width of a voxel (1.745 mm). Simulated cortical activation sites do not interfere with alignment. Global errors in quantitation from realignment are <2%. Regional errors due to partial volume effects are largest when the gantry is rotated by large angles or when the bed is translated axially by one-half the interplane distance. To minimize such partial volume effects, the algorithm can be used prospectively, during acquisition, to reposition the scanner gantry and bed to match an earlier study. Computation requires 3–6 min on a Sun SPARCstation 2.


Journal of Computer Assisted Tomography | 1998

Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation

Roger P. Woods; Scott T. Grafton; Colin J. Holmes; Simon R. Cherry; John C. Mazziotta

PURPOSE We sought to describe and validate an automated image registration method (AIR 3.0) based on matching of voxel intensities. METHOD Different cost functions, different minimization methods, and various sampling, smoothing, and editing strategies were compared. Internal consistency measures were used to place limits on registration accuracy for MRI data, and absolute accuracy was measured using a brain phantom for PET data. RESULTS All strategies were consistent with subvoxel accuracy for intrasubject, intramodality registration. Estimated accuracy of registration of structural MRI images was in the 75 to 150 microns range. Sparse data sampling strategies reduced registration times to minutes with only modest loss of accuracy. CONCLUSION The registration algorithm described is a robust and flexible tool that can be used to address a variety of image registration problems. Registration strategies can be tailored to meet different needs by optimizing tradeoffs between speed and accuracy.


Nature Medicine | 2008

Simultaneous PET-MRI: a new approach for functional and morphological imaging

Martin S. Judenhofer; Danny F. Newport; Ciprian Catana; Stefan Siegel; Markus Becker; Axel Thielscher; Manfred Kneilling; Matthias P. Lichy; Martin Eichner; Karin Klingel; Gerald Reischl; Stefan Widmaier; Martin Röcken; Robert E. Nutt; Hans Jürgen Machulla; Kamil Uludag; Simon R. Cherry; Claus D. Claussen; Bernd J. Pichler

Noninvasive imaging at the molecular level is an emerging field in biomedical research. This paper introduces a new technology synergizing two leading imaging methodologies: positron emission tomography (PET) and magnetic resonance imaging (MRI). Although the value of PET lies in its high-sensitivity tracking of biomarkers in vivo, it lacks resolving morphology. MRI has lower sensitivity, but produces high soft-tissue contrast and provides spectroscopic information and functional MRI (fMRI). We have developed a three-dimensional animal PET scanner that is built into a 7-T MRI. Our evaluations show that both modalities preserve their functionality, even when operated isochronously. With this combined imaging system, we simultaneously acquired functional and morphological PET-MRI data from living mice. PET-MRI provides a powerful tool for studying biology and pathology in preclinical research and has great potential for clinical applications. Combining fMRI and spectroscopy with PET paves the way for a new perspective in molecular imaging.


Physics in Medicine and Biology | 1998

High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner

Jinyi Qi; Richard M. Leahy; Simon R. Cherry; Arion F. Chatziioannou; Thomas H. Farquhar

A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the field of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and 18FDG animal studies appear to confirm this observation.


Gene Therapy | 1999

Repetitive, non-invasive imaging of the dopamine D2 receptor as a reporter gene in living animals.

Duncan C. MacLaren; Sanjiv S. Gambhir; Nagichettiar Satyamurthy; Jorge R. Barrio; Susan T. Sharfstein; Tatsushi Toyokuni; Lily Wu; Arnold J. Berk; Simon R. Cherry; Michael E. Phelps; Harvey R. Herschman

Reporter genes (eg β-galactosidase, chloramphenicol-acetyltransferase, green fluorescent protein, luciferase) play critical roles in investigating mechanisms of gene expression in transgenic animals and in developing gene delivery systems for gene therapy. However, measuring expression of these reporter genes requires biopsy or death. We now report a procedure to image reporter gene expression repetitively and non-invasively in living animals with positron emission tomography (PET), using the dopamine type 2 receptor (D2R) as a reporter gene and 3-(2′-[18F]fluoroethyl)spiperone (FESP) as a reporter probe. We use a viral delivery system to demonstrate the ability of this PET reporter gene/PET reporter probe system to image reporter gene expression following somatic gene transfer. In mice injected intravenously with replication-deficient adenovirus carrying a D2R reporter gene, PET in vivo measures of hepatic [18F] retention are proportional to in vitro measures of hepatic FESP retention, D2R ligand binding and D2R mRNA. We use tumor-forming cells carrying a stably transfected D2R gene to demonstrate imaging of this PET reporter gene/PET reporter probe system in ‘tissues’. Tumors expressing the transfected D2R reporter gene retain substantially more FESP than control tumors. The D2R/FESP reporter gene/reporter probe system should be a valuable technique to monitor, in vivo, expression from both gene therapy vectors and transgenes.


Physics in Medicine and Biology | 2004

In vivo molecular and genomic imaging: New challenges for imaging physics

Simon R. Cherry

The emerging and rapidly growing field of molecular and genomic imaging is providing new opportunities to directly visualize the biology of living organisms. By combining our growing knowledge regarding the role of specific genes and proteins in human health and disease, with novel ways to target these entities in a manner that produces an externally detectable signal, it is becoming increasingly possible to visualize and quantify specific biological processes in a non-invasive manner. All the major imaging modalities are contributing to this new field, each with its unique mechanisms for generating contrast and trade-offs in spatial resolution, temporal resolution and sensitivity with respect to the biological process of interest. Much of the development in molecular imaging is currently being carried out in animal models of disease, but as the field matures and with the development of more individualized medicine and the molecular targeting of new therapeutics, clinical translation is inevitable and will likely forever change our approach to diagnostic imaging. This review provides an introduction to the field of molecular imaging for readers who are not experts in the biological sciences and discusses the opportunities to apply a broad range of imaging technologies to better understand the biology of human health and disease. It also provides a brief review of the imaging technology (particularly for x-ray, nuclear and optical imaging) that is being developed to support this new field.


Physics in Medicine and Biology | 2001

Performance evaluation of the microPET P4: a PET system dedicated to animal imaging

Yuan-Chuan Tai; Arion F. Chatziioannou; Stefan Siegel; John Young; D Newport; R N Goble; Robert E. Nutt; Simon R. Cherry

The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8 x 8 array of 2.2 x 2.2 x 10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET. including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.


Physics in Medicine and Biology | 1997

Simultaneous PET and MR imaging

Yiping Shao; Simon R. Cherry; Keyvan Farahani; Ken Meadors; Stefan Siegel; Robert W. Silverman; Paul Marsden

We have developed a prototype PET detector which is compatible with a clinical MRI system to provide simultaneous PET and MR imaging. This single-slice PET system consists of 48 2 x 2 x 10 mm3 LSO crystals in a 38 mm diameter ring configuration that can be placed inside the receiver coil of the MRI system, coupled to three multi-channel photomultipliers housed outside the main magnetic field via 4 m long and 2 mm diameter optical fibres. The PET system exhibits 2 mm spatial resolution, 41% energy resolution at 511 keV and 20 ns timing resolution. Simultaneous PET and MR phantom images were successfully acquired.


Physics in Medicine and Biology | 2003

MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging

Yuan-Chuan Tai; Arion F. Chatziioannou; Yongfeng Yang; Robert W. Silverman; Ken Meadors; Stefan Siegel; Danny F. Newport; Jennifer R. Stickel; Simon R. Cherry

MicroPET II is a second-generation animal PET scanner designed for high-resolution imaging of small laboratory rodents. The system consists of 90 scintillation detector modules arranged in three contiguous axial rings with a ring diameter of 16.0 cm and an axial length of 4.9 cm. Each detector module consists of a 14 x 14 array of lutetium oxyorthosilicate (LSO) crystals coupled to a multi-channel photomultiplier tube (MC-PMT) through a coherent optical fibre bundle. Each LSO crystal element measures 0.975 mm x 0.975 mm in cross section by 12.5 mm in length. A barium sulphate reflector material was used between LSO elements leading to a detector pitch of 1.15 mm in both axial and transverse directions. Fused optical fibre bundles were made from 90 microm diameter glass fibres with a numerical aperture of 0.56. Interstitial extramural absorber was added between the fibres to reduce optical cross talk. A charge-division readout circuit was implemented on printed circuit boards to decode the 196 crystals in each array from the outputs of the 64 anode signals of the MC-PMT. Electronics from Concorde Microsystems Inc. (Knoxville, TN) were used for signal amplification, digitization, event qualification, coincidence processing and data capture. Coincidence data were passed to a host PC that recorded events in list mode. Following acquisition, data were sorted into sinograms and reconstructed using Fourier rebinning and filtered hackprojection algorithms. Basic evaluation of the system has been completed. The absolute sensitivity of the microPET II scanner was 2.26% at the centre of the field of view (CFOV) for an energy window of 250-750 keV and a timing window of 10 ns. The intrinsic spatial resolution of the detectors in the system averaged 1.21 mm full width at half maximum (FWHM) when measured with a 22Na point source 0.5 mm in diameter. Reconstructed image resolution ranged from 0.83 mm FWHM at the CFOV to 1.47 mm FWHM in the radial direction, 1.17 mm FWHM in the tangential direction and 1.42 mm FWHM in the axial direction at 1 cm offset from the CFOV. These values represent highly significant improvements over our earlier microPET scanner (approximately fourfold sensitivity increase and 25-35% improvement in linear spatial resolution under equivalent operating conditions) and are expected to be further improved when the system is fully optimized.


Physics in Medicine and Biology | 2005

Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging

Abhijit J. Chaudhari; Felix Darvas; James R. Bading; Rex Moats; Peter S. Conti; Desmond J. Smith; Simon R. Cherry; Richard M. Leahy

For bioluminescence imaging studies in small animals, it is important to be able to accurately localize the three-dimensional (3D) distribution of the underlying bioluminescent source. The spectrum of light produced by the source that escapes the subject varies with the depth of the emission source because of the wavelength-dependence of the optical properties of tissue. Consequently, multispectral or hyperspectral data acquisition should help in the 3D localization of deep sources. In this paper, we describe a framework for fully 3D bioluminescence tomographic image acquisition and reconstruction that exploits spectral information. We describe regularized tomographic reconstruction techniques that use semi-infinite slab or FEM-based diffusion approximations of photon transport through turbid media. Singular value decomposition analysis was used for data dimensionality reduction and to illustrate the advantage of using hyperspectral rather than achromatic data. Simulation studies in an atlas-mouse geometry indicated that sub-millimeter resolution may be attainable given accurate knowledge of the optical properties of the animal. A fixed arrangement of mirrors and a single CCD camera were used for simultaneous acquisition of multispectral imaging data over most of the surface of the animal. Phantom studies conducted using this system demonstrated our ability to accurately localize deep point-like sources and show that a resolution of 1.5 to 2.2 mm for depths up to 6 mm can be achieved. We also include an in vivo study of a mouse with a brain tumour expressing firefly luciferase. Co-registration of the reconstructed 3D bioluminescent image with magnetic resonance images indicated good anatomical localization of the tumour.

Collaboration


Dive into the Simon R. Cherry's collaboration.

Top Co-Authors

Avatar

Yongfeng Yang

University of California

View shared research outputs
Top Co-Authors

Avatar

Yiping Shao

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jinyi Qi

University of California

View shared research outputs
Top Co-Authors

Avatar

Richard M. Leahy

University of Southern California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yibao Wu

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge