Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Simona Gulino is active.

Publication


Featured researches published by Simona Gulino.


American Journal of Cardiology | 2011

Dual Antiplatelet Therapy Versus Aspirin Alone in Patients Undergoing Transcatheter Aortic Valve Implantation

Gian Paolo Ussia; Marilena Scarabelli; Massimiliano Mulè; Marco Barbanti; Kunal Sarkar; Valeria Cammalleri; Sebastiano Immè; Patrizia Aruta; Anna Maria Pistritto; Simona Gulino; Wanda Deste; Davide Capodanno; Corrado Tamburino

Dual antiplatelet therapy (DAPT) with clopidogrel and aspirin is a widely accepted strategy in patients undergoing transcatheter aortic valve implantation (TAVI), but this approach is not evidence based. The goal of the present study was to determine whether DAPT in patients undergoing TAVI is associated with improved outcomes compared to aspirin alone. From May 2009 to August 2010, consecutive patients were randomized to receive a 300-mg loading dose of clopidogrel on the day before TAVI followed by a 3-month maintenance daily dose of 75 mg plus aspirin 100 mg lifelong (DAPT group) or aspirin 100 mg alone (ASA group). The primary end point was the composite of major adverse cardiac and cerebrovascular events, defined as death from any cause, myocardial infarction, major stroke, urgent or emergency conversion to surgery, or life-threatening bleeding. The cumulative incidence of major adverse cardiac and cerebrovascular events at 30 days and 6 months was 14% and 16%, respectively. No significant differences between the DAPT and ASA groups were noted at both 30 days (13% vs 15%, p = 0.71) and 6 months (18% vs 15%; p = 0.85). In conclusion, the strategy of adding clopidogrel to aspirin for 3 months after TAVI was not found to be superior to aspirin alone. These results must be confirmed in a larger randomized trial.


Jacc-cardiovascular Interventions | 2015

5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis.

Marco Barbanti; Anna Sonia Petronio; Federica Ettori; Azeem Latib; Francesco Bedogni; Federico De Marco; Arnaldo Poli; Carla Boschetti; Marco De Carlo; Claudia Fiorina; Antonio Colombo; Nedy Brambilla; Giuseppe Bruschi; Paola Martina; Claudia Pandolfi; Cristina Giannini; Salvatore Curello; Carmelo Sgroi; Simona Gulino; Martina Patanè; Yohei Ohno; Claudia Tamburino; Guilherme F. Attizzani; Sebastiano Immè; Alessandra Gentili; Corrado Tamburino

OBJECTIVES The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota). BACKGROUND There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. METHODS Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. RESULTS All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. CONCLUSIONS TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.


American Journal of Cardiology | 2012

Comparison of Complications and Outcomes to One Year of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Patients With Severe Aortic Stenosis

Corrado Tamburino; Marco Barbanti; Davide Capodanno; Carmelo Mignosa; Maurizio Gentile; Patrizia Aruta; Anna Maria Pistritto; Claudio Bonanno; Salvatore Bonura; Alessandra Cadoni; Simona Gulino; Maria Concetta Di Pasqua; Valeria Cammalleri; Marilena Scarabelli; Massimiliano Mulè; Sebastiano Immè; Giuliana Del Campo; Gian Paolo Ussia

Comparisons of transcatheter aortic valve implantation (TAVI) to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis remain sparse or limited by a short follow-up. We sought to evaluate early and midterm outcomes of consecutive patients (n = 618) undergoing successful TAVI (n = 218) or isolated SAVR (n = 400) at 2 centers. The primary end point was incidence of Valvular Academic Research Consortium-defined major adverse cerebrovascular and cardiac events (MACCEs) up to 1 year. Control of potential confounders was attempted with extensive statistical adjustment by covariates and/or propensity score. In-hospital MACCEs occurred in 73 patients (11.8%) and was more frequent in patients treated with SAVR compared to those treated with TAVI (7.8% vs 14.0%, p = 0.022). After addressing potential confounders using 3 methods of statistical adjustment, SAVR was consistently associated with a higher risk of MACCEs than TAVI, with estimates of relative risk ranging from 2.2 to 2.6 at 30 days, 2.3 to 2.5 at 6 months, and 2.0 to 2.2 at 12 months. This difference was driven by an adjusted increased risk of life-threatening bleeding at 6 and 12 months and stroke at 12 months with SAVR. Conversely, no differences in adjusted risk of death, stroke and myocardial infarction were noted between TAVI and SAVR at each time point. In conclusion, in a large observational registry with admitted potential for selection bias and residual confounding, TAVI was not associated with a higher risk of 1-year MACCEs compared to SAVR.


Heart | 2015

Early discharge after transfemoral transcatheter aortic valve implantation

Marco Barbanti; Piera Capranzano; Yohei Ohno; Guilherme F. Attizzani; Simona Gulino; Sebastiano Immè; Stefano Cannata; Patrizia Aruta; Vera Bottari; Martina Patanè; Claudia Tamburino; Daniele Di Stefano; Wanda Deste; Daniela Giannazzo; Giuseppe Gargiulo; Giuseppe Caruso; Carmelo Sgroi; Denise Todaro; Emanuela Di Simone; Davide Capodanno; Corrado Tamburino

Background The aim of this study was to assess the feasibility and the safety of early discharge (within 72 h) after transfemoral transcatheter aortic valve implantation (TAVI) and to identify baseline features and/or peri-procedural variables, which may affect post-TAVI length-of-stay (LoS) duration. Methods and results Patients discharged within 72 h of TAVI (early discharge group) were compared with consecutive patients discharged after 3 days (late discharge group). Propensity-matched cohorts of patients with a 2:1 ratio were created to better control confounding bias. Among 465 patients, 107 (23.0%) were discharged within 3 days of the procedure. Multivariable regression analysis of unmatched patients demonstrated that baseline New York Heart Association (NYHA) class IV (OR: 0.22, 95% CI 0.05 to 0.96; p=0.045) and any bleeding (OR: 0.31, 95% CI 0.74 to 0.92; p=0.031) were less likely to be associated with early discharge after TAVI. Conversely, the year of procedure (OR: 1.66, 95% CI 1.25 to 2.20; p<0.001) and the presence of a permanent pacemaker (PPM) before TAVI (OR: 2.80, 95% CI 1.36 to 5.75; p=0.005) were associated with a higher probability of early discharge. In matched populations, patients in the early discharge group reported lower incidence of in-hospital bleeding (7.9% vs 19.4%, p=0.014), major vascular complications (2.3% vs 9.1%, p=0.038) and PPM implantation (7.9% vs18.5%, p=0.021), whereas after discharge, at 30-day, no significant differences were reported between groups in terms of death (2.2% vs 1.7%, p=0.540), bleeding (0.0% vs 1.1%, p=0.444), PPM implantation (1.1% vs 0.0%, p=0.333) and re-hospitalisation (1.1% vs 1.1%, p=1.000). Conclusions Early discharge (within 72 h) after transfemoral TAVI is feasible and does not seem to jeopardise the early safety of the procedure, when performed in a subset of patients selected by clinical judgement. Patients undergoing TAVI in unstable haemodynamic compensation and patients experiencing bleeding after the procedure demonstrated to be poorly suitable to this approach, whereas increasing experience in post-TAVI management was associated with a reduction of LoS.


International Journal of Cardiology | 2017

Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis

Marco Barbanti; Sergio Buccheri; Josep Rodés-Cabau; Simona Gulino; Philippe Généreux; Gerlando Pilato; Danny Dvir; Andrea Picci; Giuliano Costa; Corrado Tamburino; Martin B. Leon; John G. Webb

OBJECTIVE The aim of this study was to conduct a weighted meta-analysis to determine the rates of acute (≤30days) major outcomes after (TAVR) with second-generation devices. METHODS A comprehensive search of multiple electronic databases from January 2011 to May 2017 was conducted using predefined criteria. New-generation TAVR devices were defined as any device which received CE mark approval or is still under evaluation for CE marking after CoreValve and SAPIEN XT prostheses. RESULTS A total of 37 studies including 10,822 patients met inclusion criteria and were included in the analysis. Devices investigated in the studies were the following: SAPIEN 3 (n=5423, 45.9%), Lotus Valve (n=3007, %), Portico (n=130, 1.1%), JenaValve (n=345, 2.9%), Symetis Acurate (n=1314, 11,1%), and Evolut R (n=1603, 13.6%). Thirty-day all-cause and cardiovascular 30-day death were 2.2% (95% CI: 1.6% to 2.8%) and 1.6% (95% CI: 0.9% to 2.3%), respectively; Any stroke and major/disabling stroke occurred at a pooled estimate rate of 2.6% (95% CI: 2.0% to 3.3%) and 0.9% (95% CI: 0.2% to 1.6%), respectively; life-threatening bleeding, 3.9% (95% CI: 2.9% to 5.0%); major vascular complications, 4.5% (95% CI: 3.7% to 5.4%); pacemaker implantation, 16.2% (95% CI: 12.7% to 19.6%); more than mild aortic regurgitation, 1.6% (95% CI: 0.9 to 2.3). CONCLUSIONS Second-generation TAVR devices are associated with very low mortality and major complications rates at 30-day, and improved prosthesis performance with <2% of patients having more than mild post-procedural aortic regurgitation. On the other hand, the need for pacemaker implantation seems to remain an unresolved issue, and warrants further investigation.


Circulation-cardiovascular Interventions | 2016

Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure

Marco Barbanti; John G. Webb; Claudia Tamburino; Nicolas M. Van Mieghem; Raj Makkar; Nicolo Piazza; Azeem Latib; Jan Malte Sinning; Kim Won-Keun; Sabine Bleiziffer; Francesco Bedogni; Samir Kapadia; Didier Tchetche; Josep Rodés-Cabau; Claudia Fiorina; Luis Nombela-Franco; Federico De Marco; Peter de Jaegere; Tarun Chakravarty; Beatriz Vaquerizo; Antonio Colombo; Lars G. Svensson; Rüdiger Lange; Georg Nickenig; Helge Möllmann; Thomas Walther; Francesco Della Rosa; Yacine Elhmidi; Danny Dvir; Nedy Brambilla

Background—Transcatheter aortic valves can degenerate in a manner similar to surgical bioprostheses. Methods and Results—Clinical and echocardiographic outcomes of patients who underwent redo transcatheter aortic valve replacement (TAVR) procedures >2 weeks post procedure were collected from 14 centers. Among 13 876 patients, 50 (0.4%) underwent redo TAVR procedure at participating centers. Indications for redo TAVR were moderate–severe prosthetic aortic valve stenosis (n=10, 21.7%), moderate–severe central prosthetic aortic valve regurgitation (n=13, 28.3%), and moderate–severe paraprosthetic aortic valve regurgitation (n=25, 50.0%). The index TAVR was most commonly a Medtronic CoreValve (N=38, 76.0%), followed by Edwards SAPIEN-type valves (n=12, 24.0%) and Portico (n=1, 2.0%). The redo TAVR device was most commonly a CoreValve/Evolut R (n=29, 58.0%), followed by a SAPIEN-type valve (n=20,40.0%) or a Boston Lotus valve (n=1, 2.0%). In 40 patients (80.0%), redo TAVR was performed using the identical device type or that of the succeeding generation. Valve performance was uniformly good after redo TAVR (mean transvalvular gradient post redo TAVR: 12.5±6.1 mm Hg). At hospital discharge, all patients remained alive, with 1 nondisabling stroke (2.0%) and 1 life-threatening bleed (2.0%). Permanent pacemaker implantation was required in 3 out of 35 patients without a prior pacemaker (8.6%). Late survival was 85.1% at a median follow-up of 1589 days (range: 31–3775) after index TAVR and 635 days (range: 8–2460) after redo TAVR. Conclusions—Redo TAVR for the treatment of postprocedural and late occurrence of paravalvular regurgitation and transcatheter aortic valve prosthesis failure seems to be safe, and it is associated with favorable acute and midterm clinical and echocardiographic outcomes.


American Heart Journal | 2012

Accuracy of intracardiac echocardiography for aortic root assessment in patients undergoing transcatheter aortic valve implantation

Gian Paolo Ussia; Marco Barbanti; Kunal Sarkar; Miriam Cumbo; Patrizia Aruta; Marilena Scarabelli; Valeria Cammalleri; Sebastiano Immè; Anna Maria Pistritto; Simona Gulino; Wanda Deste; Gaetano Zingali; Valeria Garretto; Massimiliano Mulè; Salvatore Scandura; Corrado Tamburino

BACKGROUND Multislice computed tomography (MSCT) has generally been accepted as the most accurate modality fulfilling this purpose with good reproducibility. A major drawback of MSCT consists in the use of contrast dye, which may be unsafe in transcatheter aortic valve implantation (TAVI) patients who frequently are affected by renal failure. We sought to appraise the accuracy of intracardiac echocardiography (ICE) in measurements of structures in the aortic root in patients undergoing TAVI. METHODS Aortic annulus and sinus of Valsalva diameters were measured using ICE, performed during standard invasive preprocedural assessment in 30 consecutive patients with severe aortic stenosis referred for TAVI. Multislice computed tomography was performed in all patients afterward, and aortic root measurements were made by an independent radiologist. RESULTS Effective ICE measurements were obtained in all patients, easily and without any complication. Mean aortic annulus diameters were 21.9 ± 1.8 mm using ICE, 22.0 ± 1.9 mm using MSCT (3-chamber [3-C] view) and 22.8 ± 1.8 mm using the mean of long-axis and short-axis (L-ax/S-ax) view MSCT (P = .192, ICE vs 3-C MSCT; P < .001, ICE vs L-ax/S-ax MSCT, respectively). Correlation between ICE and both MSCT measurements was good (r(2) = 0.83, P < .001; r(2) = 0.80, P < .001, respectively). Mean sinus of Valsalva diameters were 32.3 ± 3.3 mm using ICE and 32.5 ± 3.1 mm using 3-C MSCT view (P = .141). Even in this case, correlation between ICE and both MSCT measurements was excellent (r(2) = 0.96, P < .001). CONCLUSIONS In patients referred for TAVI, measurements of the aortic annulus and the sinus of Valsalva using ICE compare favorably with those made at MSCT. This approach might be a useful and reproducible strategy in patients with severe renal impairment to avoid the administration of contrast dye during MSCT.


Circulation-cardiovascular Interventions | 2017

Optimized Screening of Coronary Artery Disease With Invasive Coronary Angiography and Ad Hoc Percutaneous Coronary Intervention During Transcatheter Aortic Valve Replacement

Marco Barbanti; Denise Todaro; Giuliano Costa; Gerlando Pilato; Andrea Picci; Simona Gulino; Piera Capranzano; Ketty La Spina; Emanuela Di Simone; Paolo D’Arrigo; Wanda Deste; Antonino Indelicato; Stefano Cannata; Daniela Giannazzo; Sebastiano Immè; Claudia Tamburino; Martina Patanè; Sergio Buccheri; Davide Capodanno; Carmelo Sgroi; Corrado Tamburino

Background— We sought to describe an optimized approach to coronary artery disease (CAD) screening and management in patients undergoing transcatheter aortic valve replacement (TAVR). Methods and Results— When invasive coronary angiography showed CAD, the treatment strategy and completeness of revascularization was determined based on coronary anatomy. TAVR was performed in the same setting if percutaneous coronary intervention (PCI) was uncomplicated; otherwise TAVR was postponed. A total of 604 patients undergoing CAD screening at the time of TAVR procedure were prospectively included in this study. Severe CAD was found in 136 patients (22.5%). Among patients with severe CAD, 53 patients (8.8%) underwent uncomplicated PCI. After PCI, TAVR was postponed in 2 patients (0.3%). In 83 patients (13.8%), coronary angiography showed severe CAD that was left untreated. After TAVR, all-cause and cardiovascular 30-day mortality rates were 2.4% and 1.4%, respectively. Disabling stroke, myocardial infarction, and life-threatening bleeding occurred in 0.5%, 0.8%, and 4.0% of patients, respectively. Acute kidney injury II or III rate was 3.3%. At 2 years, all-cause mortality rate was 14.1%. Disabling stroke and myocardial infarction occurred in 2.5% and 1.8% of patients, respectively. Patients undergoing TAVR and PCI in the same session had similar rate of the composite of death, disabling stroke, and myocardial infarction when compared with patients without CAD, and patients with severe CAD left untreated (TAVR+PCI: 10.4%; severe CAD left untreated: 15.4%; no-CAD: 14.8%; P=0.765). Conclusions— In patients undergoing TAVR, screening of CAD with invasive coronary angiography and ad hoc PCI during TAVR is feasible and was not associated with increased periprocedural risks. PCI followed by TAVR in the same session had similar outcomes than TAVR in which PCI was not performed.


American Journal of Cardiology | 2016

Three-Year Outcomes of Transcatheter Aortic Valve Implantation in Patients With Varying Levels of Surgical Risk (from the CoreValve ADVANCE Study).

Marco Barbanti; Molly Schiltgen; Sarah Verdoliva; Johan Bosmans; Sabine Bleiziffer; Ulrich Gerckens; Peter Wenaweser; Stephen Brecker; Simona Gulino; Corrado Tamburino; Axel Linke

This study compared 3-year clinical outcomes of patients who underwent transcatheter aortic valve implantation with the Society of Thoracic Surgeons (STS) score ≤7% to those of patients with a score >7%. Data were drawn from the ADVANCE study, a multinational post-market clinical trial that enrolled real-world patients with severe aortic stenosis treated with the CoreValve bioprosthesis. Events were independently adjudicated using Valve Academic Research Consortium-1 definitions. A total of 996 patients were implanted: STS ≤7% (n = 697, median STS 4.3%, interquartile range 3.1% to 5.4%) and STS >7% (n = 298, median STS 9.7%, interquartile range 8.0% to 12.4%). At 3 years, the STS ≤7% group had lower rates of all-cause mortality (28.6 vs 45.9, p <0.01) and cardiovascular mortality (19.0 vs 30.2, p <0.01) than the STS >7% group. No differences were observed in cerebrovascular accidents, vascular complications, bleeding, or myocardial infarction. In patients with STS ≤7%, mortality at 3 years was higher in those with moderate or severe aortic regurgitation (AR) at discharge than in those with mild or less AR (39.9% vs 22.9%; hazard ratio 1.98; 95% confidence interval 1.37 to 2.86; p <0.01). Conversely, the severity of AR at discharge did not affect 3-year mortality in patients with STS >7% (42.9% vs 44.6%, moderate/severe vs mild/less; hazard ratio 1.04; 95% confidence interval, 0.62 to 1.75; p = 0.861; p for interaction = 0.047). In conclusion, patients with STS ≤7% had lower rates of all-cause and cardiovascular mortality at 3 years after transcatheter aortic valve implantation. Complication rates were low and stable in both groups, demonstrating the safety of this procedure for patients at various levels of surgical risk.


American Journal of Cardiology | 2015

Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation.

Sung-Han Yoon; Yohei Ohno; Motoharu Araki; Marco Barbanti; Mao-Shin Lin; Jung-Min Ahn; Dong Hyun Yang; Young-Hak Kim; Sebastiano Immè; Simona Gulino; Claudia Tamburino; Carmelo Sgroi; Duk-Woo Park; Soo-Jin Kang; Seung-Whan Lee; Cheol Whan Lee; Seong-Wook Park; Toshiya Muramatsu; Hsien-Li Kao; Corrado Tamburino; Seung-Jung Park

The current transcatheter aortic valve implantation (TAVI) devices have been designed to fit Caucasian and Latin American aortic root anatomies. We evaluated the racial differences in aortic root anatomy and calcium distribution in patients with aortic stenosis who underwent TAVI. We conducted a multicenter study of 4 centers in Asia and Europe, which includes consecutive patients who underwent TAVI with preprocedural multidetector computed tomography. Quantitative assessment of aortic root dimensions, calcium volume for leaflet, and left ventricular outflow tract were retrospectively performed in a centralized core laboratory. A total of 308 patients (Asian group, n = 202; Caucasian group, n = 106) were analyzed. Compared to Caucasian group, Asian group had smaller annulus area (406.3 ± 69.8 vs 430.0 ± 76.8 mm(2); p = 0.007) and left coronary cusp diameter (30.2 ± 3.2 vs 31.1 ± 3.4 mm; p = 0.02) and lower height of left coronary artery ostia (12.0 ± 2.5 vs 13.4 ± 3.4 mm; p <0.001). Of baseline anatomic characteristics, body height showed the highest correlation with annulus area (Pearson correlation r = 0.64; p <0.001). Co-existence of lower height of left coronary artery ostia (<12 mm) and small diameter of left coronary cusp (<30 mm) were more frequent in Asian group compared with Caucasian group (35.6% vs 20.8%; p = 0.02). In contrast, there were no differences in calcium volumes of leaflet (367.2 ± 322.5 vs 359.1 ± 325.7 mm(3); p = 0.84) and left ventricular outflow tract (8.9 ± 23.4 vs 10.1 ± 23.8 mm(3); p = 0.66) between 2 groups. In conclusion, judicious consideration will be required to perform TAVI for short patients with lower height of left coronary artery ostia and small sinus of Valsalva.

Collaboration


Dive into the Simona Gulino's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge