Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Simone Nicolardi is active.

Publication


Featured researches published by Simone Nicolardi.


Journal of Proteomics | 2012

Alterations of the serum peptidome in renal cell carcinoma discriminating benign and malignant kidney tumors

Erica Gianazza; Clizia Chinello; Veronica Mainini; Marta Cazzaniga; Valeria Squeo; Giancarlo Albo; Stefano Signorini; Salvatore S. Di Pierro; Stefano Ferrero; Simone Nicolardi; Yuri E. M. van der Burgt; André M. Deelder; Fulvio Magni

Renal cell carcinoma (RCC) is typically asymptomatic and surgery usually increases patients life only for early stage tumors. However, some cystic and solid renal lesions cannot be confidently differentiated from clear-cell-RCC. Therefore possible markers for early detection and to distinguish malignant kidney tumors are needed. To this aim, we applied MALDI-TOF and LC-MS/MS analysis to RPC18 MB purified serum of ccRCC, non-ccRCC patients and controls. A cluster of five signals differentiate malignant tumors from benign renal masses and healthy subjects. Moreover, a combination of six ions showed the highest specificity and sensitivity to distinguish ccRCC from controls. Healthy subjects were also differentiated from non-ccRCC by three features. Peptide ratios obtained by MALDI-TOF were compared with those from label-free LC-ESI and no statistical difference was found (p>0.05). ESI-results were linked with MALDI profiles by both TOF/TOF sequencing and MALDI FT-ICR accurate mass measurements. About 200 unique endogenous peptides, originating from 32 proteins, were identified. Among them, SDPR and ZYX were found down-expressed, while SRGN and TMSL3 were up-expressed. In conclusion, our results suggest the possibility to discriminate malignant kidney tumors based on a cluster of serum peptides. Moreover, label-free approach may represent a valid method to verify results obtained by MALDI-TOF. This article is part of a Special Issue entitled: Integrated omics.


Analytical Chemistry | 2014

Structural Analysis of an Intact Monoclonal Antibody by Online Electrochemical Reduction of Disulfide Bonds and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Simone Nicolardi; André M. Deelder; Magnus Palmblad; Yuri E. M. van der Burgt

Structural confirmation and quality control of recombinant monoclonal antibodies (mAbs) by top-down mass spectrometry is still challenging due to the size of the proteins, disulfide content, and post-translational modifications such as glycosylation. In this study we have applied electrochemistry (EC) to overcome disulfide bridge complexity in top-down analysis of mAbs. To this end, an electrochemical cell was coupled directly to an electrospray ionization (ESI) source and a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS) equipped with a 15 T magnet. By performing online EC-assisted reduction of interchain disulfide bonds in an intact mAb, the released light chains could be selected for tandem mass spectrometry (MS/MS) analysis without interference from heavy-chain fragments. Moreover, the acquisition of full MS scans under denaturing conditions allowed profiling of all abundant mAb glycoforms. Ultrahigh-resolution FTICR-MS measurements provided fully resolved isotopic distributions of intact mAb and enabled the identification of the most abundant adducts and other interfering species. Furthermore, it was found that reduction of interchain disulfide bonds occurs in the ESI source dependent on capillary voltage and solvent composition. This phenomenon was systematically evaluated and compared with the results obtained from reduction in the electrochemical cell.


Journal of Proteome Research | 2013

Identification of new apolipoprotein-CIII glycoforms with ultrahigh resolution MALDI-FTICR mass spectrometry of human sera.

Simone Nicolardi; Yuri E. M. van der Burgt; Irina Dragan; Paul J. Hensbergen; André M. Deelder

Apolipoprotein-CIII (apoCIII) is an abundant blood glycoprotein associated with lipoprotein particles. Three different glycoforms have been described, all containing a mucin-type core-1 O-glycosylation with either zero, one or two sialic acids. Changes in the relative abundance of these glycoforms have been observed in a variety of different pathologies. In this study, ultrahigh resolution 15T MALDI Fourier transform ion cyclotron resonance (FTICR) MS was used to analyze apoCIII isoforms in serum protein profiles. For this purpose, serum proteins were purified using both a fully automated RPC18-based magnetic bead method and an RPC4 cartridge-based solid phase extraction method. Six new apoCIII isoforms were identified with low-ppm mass measurement errors and ultrahigh precision. These were characterized by more complex glycan moieties that are fucosylated instead of sialylated. To confirm the glycan moiety and localize the glycosylation site, top-down ESI-FTICR-MS/MS and bottom-up LC-ion trap MS/MS were used. A large variation in the presence and abundance of the fucosylated isoforms was found in a set of 96 serum samples. These findings of fucosylated apolipoprotein-CIII isoforms warrant further research to elucidate the implications these glycoforms may have for the plethora of studies where alterations in apoCIII have been linked to the development of many different pathologies.


Journal of Proteomics | 2012

Standardized and automated solid-phase extraction procedures for high-throughput proteomics of body fluids

Rico Derks; Simone Nicolardi; Bram de Visser; Sander van Berloo; Yuri E. M. van der Burgt; André M. Deelder

In order to balance the speed of analytical sample preparation procedures with mass spectrometry (MS)-based clinical proteomics the application of high-throughput robotic systems for body fluid workup is essential. In this paper we describe the implementation of various solid-phase extraction (SPE) sample preparation protocols on two different platforms, namely: 1) Magnetic bead-based SPE of peptides and proteins from body fluids on a Hamilton liquid handling workstation; 2) Cartridge-based SPE on a SPARK Symbiosis system. All SPE protocols were optimized for MS-based proteomics and compared with respect to obtained peptide- and protein profiles. Throughput numbers that were achieved in a 24 hour time frame for the sample workup procedures were more than 700 samples for the magnetic bead-based method and over 1000 samples for the cartridge-based method.


Journal of the American Society for Mass Spectrometry | 2010

Quality control based on isotopic distributions for high-throughput MALDI-TOF and MALDI-FTICR serum peptide profiling

Simone Nicolardi; Magnus Palmblad; Hans Dalebout; Rob A. E. M. Tollenaar; André M. Deelder; Yuri E. M. van der Burgt

In this study, we have implemented a new quality control (QC) parameter for peptide profiling based on isotopic distributions. This QC parameter is an objective measure and facilitates automatic sorting of large numbers of peptide spectra. Peptides in human serum samples were enriched using reversed-phase C18-functionalized magnetic beads using a high-throughput robotic platform. High-resolution MALDI-TOF and ultrahigh resolution MALDI-FTICR mass spectra were obtained and a workflow was developed for automated analysis and evaluation of these profiles. To this end, the isotopic distributions of multiple peptides were quantified from both MALDI-TOF and MALDI-FTICR spectra. Odd peptide isotope distributions in TOF spectra could be rationalized from ultrahigh resolution FTICR spectra that showed overlap of different peptides. The comparison of isotope patterns with estimated polyaveragine distributions was used to calculate a QC value for each single mass spectrum. Sorting these QC values enabled the best MALDI spectrum to be selected from replicate spots. Moreover, using this approach spectra containing high intensities of polymers or other contaminants and lacking peptides of interest can be efficiently removed from a clinical dataset. In general, this method simplifies the exclusion of low quality spectra from further statistical analysis.


Proteomics | 2013

Mapping O-glycosylation of apolipoprotein C-III in MALDI-FT-ICR protein profiles

Simone Nicolardi; Yuri E. M. van der Burgt; Manfred Wuhrer; André M. Deelder

Ultrahigh resolution MALDI‐FT‐ICR profiles were obtained from human serum samples that were processed using a fully automated RPC18‐based magnetic bead method. Proteins were profiled from m/z value 6630 with a resolving power of 73 000 up to m/z value 12 600 with a resolving power of 37 000. In this study, a detailed evaluation was performed of the isoforms of apolipoprotein C‐III, i.e. the different mucin‐type core 1 O‐glycans with the addition of one or two sialic acid residues. The MALDI‐FT‐ICR profiles are discussed with regard to reproducibility of the signal intensities as well as the accurate mass measurements. ESI‐FT‐ICR‐MS/MS analyses of the same serum samples were performed to confirm the identity of apolipoprotein C‐III glycoforms.


Analytical Chemistry | 2015

Top-Down MALDI-In-Source Decay-FTICR Mass Spectrometry of Isotopically Resolved Proteins

Simone Nicolardi; Linda Switzar; André M. Deelder; Magnus Palmblad; Yuri E. M. van der Burgt

An accurate mass measurement of a known protein provides information on potential amino acid deletions and post-translational modifications. Although this field is dominated by strategies based on electrospray ionization, mass spectrometry (MS) methods using matrix-assisted laser desorption/ionization (MALDI) have the advantage of yielding predominantly singly charged precursor ions, thus avoiding peak overlap from different charge states of multiple species. Such MALDI-MS methods require mass measurement at ultrahigh resolution, which is provided by Fourier transform ion cyclotron resonance (FTICR) mass analyzers. Recently, using a MALDI-FTICR-MS platform equipped with a 15 T magnet, we reported on the mass analysis of intact human serum peptides and small proteins with isotopic resolution up to ∼15 kDa and identified new proteoforms from an accurate measurement of mass distances. In the current study, we have used this FTICR system after an upgrade with a novel dynamically harmonized ICR cell, i.e., ParaCell, for mapping isotopically resolved intact proteins up to about 17 kDa and performed top-down MALDI in-source decay (ISD) analysis. Standard proteins myoglobin (m/z-value 16,950) and ribonuclease B (m/z-value 14,900) were measured with resolving powers of 62,000 and 61,000, respectively. Furthermore, it will be shown that (singly charged) MALDI-ISD fragment ions can be measured at isotopic resolution up to m/z-value 12,000 (e.g., resolving power 39,000 at m/z-value 12,000) providing more reliable identifications. Moreover, examples are presented of pseudo-MS(3) experiments on ISD fragment ions from RNase B by collisional-induced dissociation (CID).


Scientific Reports | 2017

Ultra-High Mass Resolution MALDI Imaging Mass Spectrometry of Proteins and Metabolites in a Mouse Model of Glioblastoma

Marialaura Dilillo; Rima Ait-Belkacem; C. Esteve; D. Pellegrini; Simone Nicolardi; Mario Costa; Eleonora Vannini; E. L. de Graaf; Matteo Caleo; Liam A. McDonnell

MALDI mass spectrometry imaging is able to simultaneously determine the spatial distribution of hundreds of molecules directly from tissue sections, without labeling and without prior knowledge. Ultra-high mass resolution measurements based on Fourier-transform mass spectrometry have been utilized to resolve isobaric lipids, metabolites and tryptic peptides. Here we demonstrate the potential of 15T MALDI-FTICR MSI for molecular pathology in a mouse model of high-grade glioma. The high mass accuracy and resolving power of high field FTICR MSI enabled tumor specific proteoforms, and tumor-specific proteins with overlapping and isobaric isotopic distributions to be clearly resolved. The protein ions detected by MALDI MSI were assigned to proteins identified by region-specific microproteomics (0.8 mm2 regions isolated using laser capture microdissection) on the basis of exact mass and isotopic distribution. These label free quantitative experiments also confirmed the protein expression changes observed by MALDI MSI and revealed changes in key metabolic proteins, which were supported by in-situ metabolite MALDI MSI.


Analytical Chemistry | 2013

Detection and Structural Elucidation of Esterified Oxylipids in Human Synovial Fluid by Electrospray Ionization-Fourier Transform Ion-Cyclotron Mass Spectrometry and Liquid Chromatography-Ion Trap-MS3: Detection of Esterified Hydroxylated Docosapentaenoic Acid Containing Phospholipids

Hulda S. Jónasdóttir; Simone Nicolardi; Willem Jonker; Rico Derks; Magnus Palmblad; Andreea Ioan-Facsinay; René E. M. Toes; Yuri E. M. van der Burgt; André M. Deelder; Oleg A. Mayboroda; Martin Giera

Here, we present the application of a cross-platform approach, combining rapid direct infusion high-resolution/accurate mass electrospray ionization Fourier transform ion-cyclotron mass spectrometry (ESI-FTICRMS) with in-depth data-dependent LC-MS(2) and LC-MS(3) analysis for lipid profiling. The analytical approach as well as the subsequent data handling is described. The method was applied to human synovial fluid samples from osteo- and rheumatoid arthritis patients. Multivariate statistical analysis revealed esterified oxylipids as molecular features in a subset of the patient samples. Employing LC-MS(2) and LC-MS(3) analysis of these species, we were able to clarify the hypothesized lipid structures initially based on the accurate mass measurements performed on the ESI-FTICRMS platform. LC-MS(3) analysis of intact esterified oxy-lipids and LC-MS(2) analysis of the hydrolysis products allowed for the detection of positional isomers. The approach led to the structural elucidation of hydroxylated docosapentaenoic acid-containing diacyl-phosphatidylcholine type phospholipids in human synovial fluid.


Rapid Communications in Mass Spectrometry | 2011

Precision profiling and identification of human serum peptides using Fourier transform ion cyclotron resonance mass spectrometry

Simone Nicolardi; Magnus Palmblad; Paul J. Hensbergen; Rob A. E. M. Tollenaar; André M. Deelder; Yuri E. M. van der Burgt

Many biomarker discovery studies are based on matrix-assisted laser desorption/ionisation (MALDI) peptide profiles. In this study, 96 human serum samples were analysed on a Bruker solariX(TM) MALDI Fourier transform ion cyclotron resonance (FTICR) system equipped with a 15 tesla magnet. Isotopically resolved peptides were observed in ultrahigh resolution FTICR profiles up to m/z 6500 with mass measurement errors (MMEs) of previously identified peptides at a sub-ppm level. For comparison with our previous platform for peptide profile mass analysis (i.e. Ultraflex II) the corresponding time-of-flight (TOF) spectra were obtained with isotopically resolved peptides up to m/z 3500. The FTICR and TOF systems performed rather similar with respect to the repeatability of the signal intensities. However, the mass measurement precision improved at least 10-fold in ultrahigh resolution data and thus simplified spectral alignment necessary for robust and quantitatively precise comparisons of profiles in large-scale clinical studies. From each single MALDI-FTICR spectrum an m/z-list was obtained with sub-ppm precision for all different species, which is beneficial for identification purposes and interlaboratory comparisons. Furthermore, the FTICR system allowed new peptide identifications from collision-induced dissociation (CID) spectra using direct infusion of reversed-phase (RP) C(18)-fractionated serum samples on an electrospray ionisation (ESI) source.

Collaboration


Dive into the Simone Nicolardi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

André M. Deelder

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Rob A. E. M. Tollenaar

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Magnus Palmblad

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Paul J. Hensbergen

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Wilma E. Mesker

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Manfred Wuhrer

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Bert A. Bonsing

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge