Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Siti Zarina Mohd. Muji is active.

Publication


Featured researches published by Siti Zarina Mohd. Muji.


international conference on mechatronics | 2011

Electronic design for portable electrical capacitance sensor: A multiphase flow measurement

E. Johana Mohamad; O. M. Faizan Marwah; Ruzairi Abdul Rahim; Mohd Hafiz Fazalul Rahiman; Siti Zarina Mohd. Muji

The earlier research shows that the electrical capacitance sensor through the tomography technique is applicable in flow visualization or image reconstruction, named as Electrical Capacitance Tomography (ECT). ECT can be used for imaging industrial multi-component processes involving nonconducting fluids and solids in pipelines. The electrical capacitance sensor is a non-invasive device that uses non-intrusive technique to measure the concentration of flow inside a closed pipe by measuring variations in the dielectric permittivity of the material. The capacitance of the sensor changes when the mean dielectric constant between the electrodes varies due to variations in the percentage of gas and liquid flowing in the pipe. The acquired concentration profile that obtains from capacitance measurements is able to imaging liquid and gas mixture in pipelines, meanwhile the system development is designed to attach on a vessel. The electrode plates which act as the sensor previously has been assemble fixed on the pipeline, thus it causes difficulty for the production to have any new process installation in the future. Therefore on-board sensing plate offers a new design and idea on ECT system which is portable to be assembled in different diameter sizes of pipeline, and its flexible to apply in any number due to different size of pipeline without redesign the sensing module. The on-board sensing plate development contains signal conditioning circuit and sensing electrode built in a single module (embedded on single plate). In this paper, the details on fabricating the sensors electrodes, had been described, including signal conditioning circuit/electronic part of measurement, such as stray immune capacitance measurement circuit, amplifying circuit, AC to DC converter circuit and filter circuit.


ieee international conference on photonics | 2013

Sensors and projection overview of optical tomography

Siti Zarina Mohd. Muji; Mohd Fadzli Abdul Shaib; R. Abdul Rahim; Chiew Loon Goh; H. Abdul Rahim; Zahriladha Zakaria

This paper reviews previous research on sensor arrays, projection arrangements and image reconstruction algorithms of optical tomography for industrial processes. These include the review of sensor selection and projection arrangement technique to optimize system performance. Issues on types of algorithm for image reconstruction purposes, which is one of the factors to increase the resolution of the image, will also be elaborated. This review could provide a preliminary decision overview for students or researchers before initiating a research related to optical tomography.


Journal of Independent Studies and Research - Computing | 2016

Online Optical Tomography System Application of Charge-Coupled Device (CCD) for Object Detection in Crystal Clear Water

Juliza Jamaludin; Ruzairi Abdul Rahim; Herlina Abdul Rahim; Mohd Hafiz Fazalul Rahiman; Siti Zarina Mohd. Muji; Jemmy Mohd Rohani


Sensors & Transducers | 2012

Measurement of bubble flow in liquid using optical tomography

Naizatul Shima Mohd Fadzil; Siti Zarina Mohd. Muji; Ruzairi Abdul Rahim; Yusri Yunus; Salinda Bunyamin; Shafishuaza Sahlan; Nor Muzakkir Nor Ayob


Archive | 2011

Development of pulse rate measurement system using programmable system on chip (PSOC) application

Zulkarnay Zakaria; Nur Syazwana Khairudin; Ruzairi Abdul Rahim; Mohd Hafiz Fazalul Rahiman; Siti Zarina Mohd. Muji


Archive | 2011

Aplikasi 12C menggunakan PIC 18F4520

Siti Zarina Mohd. Muji; Ruzairi Abdul Rahim


Archive | 2011

Gravity flow rig operation in control lab, FKE, UTM

Siti Zarina Mohd. Muji; Temour Tajdari; Ruzairi Abdul Rahim; M. F. Rahmat


Archive | 2011

Application of 12c protocol in data transfer

Ruzairi Abdul Rahim; Siti Zarina Mohd. Muji; Mohd Hafiz Fazalul Rahiman; Zulkarnay Zakaria


Archive | 2011

Magnetic induction tomography (MIT): a review on excitation coil design aspects

Zulkarnay Zakaria; Ruzairi Abdul Rahim; Mohd. Hafiz Hussain; Nurfarahiyah Mohammad; Siti Zarina Mohd. Muji


Archive | 2011

Liver cancer from view of physiological and medical imaging

Zulkarnay Zakaria; Mohd Hafiz Fazalul Rahiman; Ruzairi Abdul Rahim; Muhammad Saiful Badri Mansor; Siti Zarina Mohd. Muji

Collaboration


Dive into the Siti Zarina Mohd. Muji's collaboration.

Top Co-Authors

Avatar

Ruzairi Abdul Rahim

Universiti Tun Hussein Onn Malaysia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Zulkarnay Zakaria

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

Chiew Loon Goh

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

H. Abdul Rahim

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

Herlina Abdul Rahim

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

Juliza Jamaludin

Universiti Sains Islam Malaysia

View shared research outputs
Top Co-Authors

Avatar

M. F. Rahmat

Universiti Teknologi Malaysia

View shared research outputs
Top Co-Authors

Avatar

Mohd Fadzli Abdul Shaib

Universiti Tun Hussein Onn Malaysia

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge