Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Soumitesh Chakravorty is active.

Publication


Featured researches published by Soumitesh Chakravorty.


Journal of Clinical Microbiology | 2010

Evaluation of the Analytical Performance of the Xpert MTB/RIF Assay

Robert Blakemore; Elizabeth Story; Danica Helb; JoAnn Kop; Padmapriya P. Banada; Michelle R. Owens; Soumitesh Chakravorty; Martin Jones; David Alland

ABSTRACT We performed the first studies of analytic sensitivity, analytic specificity, and dynamic range for the new Xpert MTB/RIF assay, a nucleic acid amplification-based diagnostic system that detects Mycobacterium tuberculosis and rifampin (RIF) resistance in under 2 h. The sensitivity of the assay was tested with 79 phylogenetically and geographically diverse M. tuberculosis isolates, including 42 drug-susceptible isolates and 37 RIF-resistant isolates containing 13 different rpoB mutations or mutation combinations. The specificity of the assay was tested with 89 nontuberculosis bacteria, fungi, and viruses. The Xpert MTB/RIF assay correctly identified all 79 M. tuberculosis isolates and correctly excluded all 89 nontuberculosis isolates. RIF resistance was correctly identified in all 37 resistant isolates and in none of the 42 susceptible isolates. Dynamic range was assessed by adding 102 to 107 CFU of M. tuberculosis into M. tuberculosis-negative sputum samples. The assay showed a log-linear relationship between cycle threshold and input CFU over the entire concentration range. Resistance detection in the presence of different mixtures of RIF-resistant and RIF-susceptible DNA was assessed. Resistance detection was dependent on the particular mutation and required between 65% and 100% mutant DNA to be present in the sample for 95% certainty of resistance detection. Finally, we studied whether assay specificity could be affected by cross-contaminating amplicons generated by the GenoType MTBDRplus assay. M. tuberculosis was not detected until at least 108 copies of an MTBDRplus amplicon were spiked into 1 ml of sputum, suggesting that false-positive results would be unlikely to occur.


Journal of Clinical Microbiology | 2005

Diagnosis of extrapulmonary tuberculosis by smear, culture, and PCR using universal sample processing technology.

Soumitesh Chakravorty; Manas Kamal Sen; Jaya Sivaswami Tyagi

ABSTRACT Definitive and rapid diagnosis of extrapulmonary tuberculosis is challenging since conventional techniques have limitations. We have developed a universal sample processing (USP) technology for detecting mycobacteria in clinical specimens. In this study, this technology was evaluated blindly on 99 extrapulmonary specimens collected from 87 patients. USP-processed specimens were submitted to smear microscopy for detection of acid-fast bacilli (AFB), culture, and two PCR tests targeting devR (Rv3133c) and IS6110 gene sequences. On the basis of clinical characteristics, histology and cytology, conventional microbiology results, and response to antitubercular therapy, 68 patients were diagnosed with tuberculosis. Although USP smear and culture were significantly superior to conventional microbiology, which was not optimized (P < 0.0001), these approaches fell short of PCR tests (P < 0.0001). The low yields by smear and culture are attributed to the paucibacillary load in the specimens. The highest sensitivity in PCR was achieved when devR and IS6110 test results were combined; the sensitivity and specificity values were 83 and 93.8%, 87.5 and 100%, and 66.7 and 75%, respectively, in pleural fluid, needle-biopsied pleural tissue, and lymph node specimens. In conclusion, the application of USP technology, together with clinicopathological characteristics, promises to improve the accuracy and confidence of extrapulmonary tuberculosis diagnosis.


Journal of Clinical Microbiology | 2005

Novel Multipurpose Methodology for Detection of Mycobacteria in Pulmonary and Extrapulmonary Specimens by Smear Microscopy, Culture, and PCR

Soumitesh Chakravorty; Jaya Sivaswami Tyagi

ABSTRACT A novel, robust, reproducible, and multipurpose universal sample processing (USP) methodology for highly sensitive smear microscopy, culturing on solid and liquid media, and inhibition-free PCR which is suitable for the laboratory diagnosis of both pulmonary and extrapulmonary tuberculosis (TB) has been developed. This method exploits the chaotropic properties of guanidinium hydrochloride for sample processing and involves incubating the specimen with USP solution, concentrating bacilli by centrifugation, and using the processed specimen for smear microscopy, culture, and PCR. The detection limit for acid-fast bacilli in spiked sputum by smear microscopy is approximately 300 bacilli per ml of specimen. USP solution-treated specimens are fully compatible with culturing on solid and liquid media. High-quality, PCR-amplifiable mycobacterial DNA can be isolated from all types of clinical specimens processed with USP solution. The method has been extensively validated with both pulmonary and extrapulmonary specimens. Furthermore, the USP method is also compatible with smear microscopy, culture, and PCR of mycobacteria other than tubercle bacilli. In summary, the USP method provides smear microscopy, culture, and nucleic acid amplification technologies with a single sample-processing platform and, to the best of our knowledge, is the only method of its kind described to date. It is expected to be useful for the laboratory diagnosis of TB and other mycobacterial diseases by conventional and modern methods.


Journal of Clinical Microbiology | 2005

Utility of Universal Sample Processing Methodology, Combining Smear Microscopy, Culture, and PCR, for Diagnosis of Pulmonary Tuberculosis

Soumitesh Chakravorty; Mridu Dudeja; Mahmud Hanif; Jaya Sivaswami Tyagi

ABSTRACT The universal sample processing (USP) multipurpose methodology was developed for the diagnosis of tuberculosis (TB) and other mycobacterial diseases by using smear microscopy, culture, and PCR (S. Chakravorty and J. S. Tyagi, J. Clin. Microbiol. 43:2697-2702, 2005). Its performance was evaluated in a blinded study of 571 sputa and compared with that of the direct and N-acetyl l-cysteine (NALC)-NaOH methods of smear microscopy and culture. With culture used as the gold standard, USP smear microscopy demonstrated a sensitivity and specificity of 98.2% and 91.4%, respectively, compared to 68.6% and 92.6%, respectively, for the direct method. For a subset of 325 specimens, the USP method recorded a 97.1% sensitivity and 83.2% specificity compared to the NALC-NaOH method, which had a sensitivity and specificity of 80.0% and 89.7%, respectively, with culture used as the gold standard. Thus, the USP method exhibited a highly significant enhancement in sensitivity (P < 0.0001) compared to the direct and NALC-NaOH methods of smear microscopy. The USP culture sensitivity was 50.1% and was not significantly different from that of conventional methods (53.6%). The sensitivity and specificity of IS6110 PCR were 99.1% and 71.2%, respectively, with culture used as the gold standard, and increased to 99.7% and 78.8%, respectively, when compared with USP smear microscopy. Thus, the USP methodology was highly efficacious in diagnosing TB by smear microscopy, culture, and PCR in a clinical setting.


Journal of Clinical Microbiology | 2011

Rapid Detection of Fluoroquinolone-Resistant and Heteroresistant Mycobacterium tuberculosis by Use of Sloppy Molecular Beacons and Dual Melting-Temperature Codes in a Real-Time PCR Assay

Soumitesh Chakravorty; Bola Aladegbami; Kimberley Thoms; Jong Seok Lee; Eun Gae Lee; Vignesh Rajan; Eunjin Cho; Hyunchul Kim; Hyun-Kyung Kwak; Natalia Kurepina; Sang-Nae Cho; Barry N. Kreiswirth; Laura E. Via; Clifton E. Barry; David Alland

ABSTRACT Fluoroquinolones (FQ) are important second-line drugs to treat tuberculosis; however, FQ resistance is an emerging problem. Resistance has been mainly attributed to mutations in a 21-bp region of the Mycobacterium tuberculosis gyrA gene, often called the quinolone resistance-determining region (QRDR). We have developed a simple, rapid, and specific assay to detect FQ resistance-determining QRDR mutations. The assay amplifies the M. tuberculosis gyrA QRDR in an asymmetrical PCR followed by probing with two sloppy molecular beacons (SMBs) spanning the entire QRDR. Mutations are detected by melting temperature (Tm ) shifts that occur when the SMBs bind to mismatched sequences. By testing DNA targets corresponding to all known QRDR mutations, we found that one or both of the SMBs produced a Tm shift of at least 3.6°C for each mutation, making mutation detection very robust. The assay was also able to identify mixtures of wild-type and mutant DNA, with QRDR mutants identified in samples containing as little as 5 to 10% mutant DNA. The assay was blindly validated for its ability to identify the QRDR mutations on DNA extracted from clinical M. tuberculosis strains. Fifty QRDR wild-type samples, 34 QRDR mutant samples, and 8 heteroresistant samples containing mixtures of wild-type and mutant DNA were analyzed. The results showed 100% concordance to conventional DNA sequencing, including a complete identification of all of the mixtures. This SMB Tm shift assay will be a valuable molecular tool to rapidly detect FQ resistance and to detect the emergence of FQ heteroresistance in clinical samples from tuberculosis patients.


Mbio | 2017

The new Xpert MTB/RIF ultra: Improving detection of Mycobacterium tuberculosis and resistance to Rifampin in an assay suitable for point-of-care testing

Soumitesh Chakravorty; Ann Marie Simmons; Mazhgan Rowneki; Heta Parmar; Yuan Cao; Jamie Ryan; Padmapriya P. Banada; Srinidhi Deshpande; Shubhada Shenai; Jennifer Glass; Barry Krieswirth; Samuel G. Schumacher; Pamela Nabeta; Nestani Tukvadze; Camilla Rodrigues; Alena Skrahina; Elisa Tagliani; Daniela Maria Cirillo; Amy L. Davidow; Claudia M. Denkinger; David H. Persing; Robert Kwiatkowski; Martin Jones; David Alland

ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R.


Journal of Clinical Microbiology | 2010

Rapid Universal Identification of Bacterial Pathogens from Clinical Cultures by Using a Novel Sloppy Molecular Beacon Melting Temperature Signature Technique

Soumitesh Chakravorty; Bola Aladegbami; Michele Burday; Michael H. Levi; Salvatore A. E. Marras; Darshini Shah; Hiyam H. El-Hajj; Fred Russell Kramer; David Alland

ABSTRACT A real-time PCR assay with the ability to rapidly identify all pathogenic bacteria would have widespread medical utility. Current real-time PCR technologies cannot accomplish this task due to severe limitations in multiplexing ability. To this end, we developed a new assay system which supports very high degrees of multiplexing. We developed a new class of mismatch-tolerant “sloppy” molecular beacons, modified them to provide an extended hybridization range, and developed a multiprobe, multimelting temperature (Tm) signature approach to bacterial species identification. Sloppy molecular beacons were exceptionally versatile, and they were able to generate specific Tm values for DNA sequences that differed by as little as one nucleotide to as many as 23 polymorphisms. Combining the Tm values generated by several probe-target hybrids resulted in Tm signatures that served as highly accurate sequence identifiers. Using this method, PCR assays with as few as six sloppy molecular beacons targeting bacterial 16S rRNA gene segments could reproducibly classify 119 different sequence types of pathogenic and commensal bacteria, representing 64 genera, into 111 Tm signature types. Blinded studies using the assay to identify the bacteria present in 270 patient-derived clinical cultures including 106 patient blood cultures showed a 95 to 97% concordance with conventional methods. Importantly, no bacteria were misidentified; rather, the few species that could not be identified were classified as “indeterminate,” resulting in an assay specificity of 100%. This approach enables highly multiplexed target detection using a simple PCR format that can transform infectious disease diagnostics and improve patient outcomes.


PLOS ONE | 2012

Highly Sensitive Detection of Staphylococcus aureus Directly from Patient Blood

Padmapriya P. Banada; Soumitesh Chakravorty; Darshini Shah; Michele Burday; Fermina M. Mazzella; David Alland

Background Rapid detection of bloodstream infections (BSIs) can be lifesaving. We investigated the sample processing and assay parameters necessary for highly-sensitive detection of bloodstream bacteria, using Staphylococcus aureus as a model pathogen and an automated fluidic sample processing – polymerase chain reaction (PCR) platform as a model diagnostic system. Methodology/Principal Findings We compared a short 128 bp amplicon hemi-nested PCR and a relatively shorter 79 bp amplicon nested PCR targeting the S. aureus nuc and sodA genes, respectively. The sodA nested assay showed an enhanced limit of detection (LOD) of 5 genomic copies per reaction or 10 colony forming units (CFU) per ml blood over 50 copies per reaction or 50 CFU/ml for the nuc assay. To establish optimal extraction protocols, we investigated the relative abundance of the bacteria in different components of the blood (white blood cells (WBCs), plasma or whole blood), using the above assays. The blood samples were obtained from the patients who were culture positive for S. aureus. Whole blood resulted in maximum PCR positives with sodA assay (90% positive) as opposed to cell-associated bacteria (in WBCs) (71% samples positive) or free bacterial DNA in plasma (62.5% samples positive). Both the assays were further tested for direct detection of S. aureus in patient whole blood samples that were contemporaneous culture positive. S. aureus was detected in 40/45 of culture-positive patients (sensitivity 89%, 95% CI 0.75–0.96) and 0/59 negative controls with the sodA assay (specificity 100%, 95% CI 0.92–1). Conclusions We have demonstrated a highly sensitive two-hour assay for detection of sepsis causing bacteria like S. aureus directly in 1 ml of whole blood, without the need for blood culture.


Lancet Infectious Diseases | 2018

Xpert MTB/RIF Ultra for detection of Mycobacterium tuberculosis and rifampicin resistance: a prospective multicentre diagnostic accuracy study

Susan E. Dorman; Samuel G Schumacher; David Alland; Pamela Nabeta; Derek T. Armstrong; Bonnie King; Sandra L. Hall; Soumitesh Chakravorty; Daniela M. Cirillo; Nestani Tukvadze; Nino Bablishvili; Wendy Stevens; Lesley Scott; Camilla Rodrigues; Mubin I Kazi; Moses Joloba; Lydia Nakiyingi; Mark P. Nicol; Yonas Ghebrekristos; Irene Anyango; Wilfred Murithi; Reynaldo Dietze; Renata Lyrio Peres; Alena Skrahina; Vera Auchynka; Kamal Kishore Chopra; Mahmud Hanif; Xin Liu; Xing Yuan; Catharina Boehme

Summary Background The Xpert MTB/RIF assay is an automated molecular test that has improved the detection of tuberculosis and rifampicin resistance, but its sensitivity is inadequate in patients with paucibacillary disease or HIV. Xpert MTB/RIF Ultra (Xpert Ultra) was developed to overcome this limitation. We compared the diagnostic performance of Xpert Ultra with that of Xpert for detection of tuberculosis and rifampicin resistance. Methods In this prospective, multicentre, diagnostic accuracy study, we recruited adults with pulmonary tuberculosis symptoms presenting at primary health-care centres and hospitals in eight countries (South Africa, Uganda, Kenya, India, China, Georgia, Belarus, and Brazil). Participants were allocated to the case detection group if no drugs had been taken for tuberculosis in the past 6 months or to the multidrug-resistance risk group if drugs for tuberculosis had been taken in the past 6 months, but drug resistance was suspected. Demographic information, medical history, chest imaging results, and HIV test results were recorded at enrolment, and each participant gave at least three sputum specimen on 2 separate days. Xpert and Xpert Ultra diagnostic performance in the same sputum specimen was compared with culture tests and drug susceptibility testing as reference standards. The primary objectives were to estimate and compare the sensitivity of Xpert Ultra test with that of Xpert for detection of smear-negative tuberculosis and rifampicin resistance and to estimate and compare Xpert Ultra and Xpert specificities for detection of rifampicin resistance. Study participants in the case detection group were included in all analyses, whereas participants in the multidrug-resistance risk group were only included in analyses of rifampicin-resistance detection. Findings Between Feb 18, and Dec 24, 2016, we enrolled 2368 participants for sputum sampling. 248 participants were excluded from the analysis, and 1753 participants were distributed to the case detection group (n=1439) and the multidrug-resistance risk group (n=314). Sensitivities of Xpert Ultra and Xpert were 63% and 46%, respectively, for the 137 participants with smear-negative and culture-positive sputum (difference of 17%, 95% CI 10 to 24); 90% and 77%, respectively, for the 115 HIV-positive participants with culture-positive sputum (13%, 6·4 to 21); and 88% and 83%, respectively, across all 462 participants with culture-positive sputum (5·4%, 3·3 to 8·0). Specificities of Xpert Ultra and Xpert for case detection were 96% and 98% (−2·7%, −3·9 to −1·7) overall, and 93% and 98% for patients with a history of tuberculosis. Xpert Ultra and Xpert performed similarly in detecting rifampicin resistance. Interpretation For tuberculosis case detection, sensitivity of Xpert Ultra was superior to that of Xpert in patients with paucibacillary disease and in patients with HIV. However, this increase in sensitivity came at the expense of a decrease in specificity. Funding Government of Netherlands, Government of Australia, Bill & Melinda Gates Foundation, Government of the UK, and the National Institute of Allergy and Infectious Diseases.


Journal of Clinical Microbiology | 2012

Rapid, High-Throughput Detection of Rifampin Resistance and Heteroresistance in Mycobacterium tuberculosis by Use of Sloppy Molecular Beacon Melting Temperature Coding

Soumitesh Chakravorty; Harsheel Kothari; Bola Aladegbami; Eun Jin Cho; Jong Seok Lee; Sandy S. Roh; Hyunchul Kim; Hyungkyung Kwak; Eun Gae Lee; Soo Hee Hwang; Padmapriya P. Banada; Hassan Safi; Laura E. Via; Sang-Nae Cho; Clifton E. Barry; David Alland

ABSTRACT Rifampin resistance in Mycobacterium tuberculosis is largely determined by mutations in an 80-bp rifampin resistance determining region (RRDR) of the rpoB gene. We developed a rapid single-well PCR assay to identify RRDR mutations. The assay uses sloppy molecular beacons to probe an asymmetric PCR of the M. tuberculosis RRDR by melting temperature (Tm ) analysis. A three-point Tm code is generated which distinguishes wild-type from mutant RRDR DNA sequences in approximately 2 h. The assay was validated on synthetic oligonucleotide targets containing the 44 most common RRDR mutations. It was then tested on a panel of DNA extracted from 589 geographically diverse clinical M. tuberculosis cultures, including isolates with wild-type RRDR sequences and 25 different RRDR mutations. The assay detected 236/236 RRDR mutant sequences as mutant (sensitivity, 100%; 95% confidence interval [CI], 98 to 100%) and 353/353 RRDR wild-type sequences as wild type (specificity, 100%; 95% CI, 98.7 to 100%). The assay identified 222/225 rifampin-resistant isolates as rifampin resistant (sensitivity, 98.7%; 95% CI, 95.8 to 99.6%) and 335/336 rifampin-susceptible isolates as rifampin susceptible (specificity, 99.7%; 95% CI, 95.8 to 99.6%). All mutations were either individually identified or clustered into small mutation groups using the triple Tm code. The assay accurately identified mixed (heteroresistant) samples and was shown analytically to detect RRDR mutations when present in at least 40% of the total M. tuberculosis DNA. This was at least as accurate as Sanger DNA sequencing. The assay was easy to use and well suited for high-throughput applications. This new sloppy molecular beacon assay should greatly simplify rifampin resistance testing in clinical laboratories.

Collaboration


Dive into the Soumitesh Chakravorty's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Clifton E. Barry

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Laura E. Via

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar

Jaya Sivaswami Tyagi

All India Institute of Medical Sciences

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge