Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Spencer Gessner is active.

Publication


Featured researches published by Spencer Gessner.


Nature | 2015

Multi-gigaelectronvolt acceleration of positrons in a self-loaded plasma wakefield

S. Corde; E. Adli; J. Allen; Weiming An; Christine Clarke; C. E. Clayton; Jean-Pierre Delahaye; J. Frederico; Spencer Gessner; Selina Green; M.J. Hogan; C. Joshi; Nate Lipkowitz; M. Litos; W. Lu; K. A. Marsh; W. B. Mori; Margaux Schmeltz; N. Vafaei-Najafabadi; D. Walz; V. Yakimenko; Gerald Yocky

Electrical breakdown sets a limit on the kinetic energy that particles in a conventional radio-frequency accelerator can reach. New accelerator concepts must be developed to achieve higher energies and to make future particle colliders more compact and affordable. The plasma wakefield accelerator (PWFA) embodies one such concept, in which the electric field of a plasma wake excited by a bunch of charged particles (such as electrons) is used to accelerate a trailing bunch of particles. To apply plasma acceleration to electron–positron colliders, it is imperative that both the electrons and their antimatter counterpart, the positrons, are efficiently accelerated at high fields using plasmas. Although substantial progress has recently been reported on high-field, high-efficiency acceleration of electrons in a PWFA powered by an electron bunch, such an electron-driven wake is unsuitable for the acceleration and focusing of a positron bunch. Here we demonstrate a new regime of PWFAs where particles in the front of a single positron bunch transfer their energy to a substantial number of those in the rear of the same bunch by exciting a wakefield in the plasma. In the process, the accelerating field is altered—‘self-loaded’—so that about a billion positrons gain five gigaelectronvolts of energy with a narrow energy spread over a distance of just 1.3 metres. They extract about 30 per cent of the wake’s energy and form a spectrally distinct bunch with a root-mean-square energy spread as low as 1.8 per cent. This ability to transfer energy efficiently from the front to the rear within a single positron bunch makes the PWFA scheme very attractive as an energy booster to an electron–positron collider.


arXiv: Accelerator Physics | 2013

A Beam Driven Plasma-Wakefield Linear Collider: From Higgs Factory to Multi-TeV

E. Adli; Jean-Pierre Delahaye; Spencer Gessner; Mark Hogan; T. Raubenheimer; Weiming An; C. Joshi; W. B. Mori

Plasma wakefield acceleration (PWFA) holds much promise for advancing the energy frontier because it can potentially provide a 1000-fold or more increase in acceleration gradient with excellent power efficiency in respect with standard technologies. Most of the advances in beam-driven plasma wakefield acceleration were obtained by a UCLA/USC/SLAC collaboration working at the SLAC FFTB[ ]. These experiments have shown that plasmas can accelerate and focus both electron and positron high energy beams, and an accelerating gradient in excess of 50 GeV/m can be sustained in an 85 cm-long plasma. The FFTB experiments were essentially proof-of-principle experiments that showed the great potential of plasma accelerators. The FACET[ ] test facility at SLAC will in the period 2012-2016 further study several issues that are directly related to the applicability of PWFA to a high-energy collider, in particular two-beam acceleration where the witness beam experiences high beam loading (required for high efficiency), small energy spread and small emittance dilution (required to achieve luminosity). The PWFA-LC concept presented in this document is an attempt to find the best design that takes advantage of the PWFA, identify the critical parameters to be achieved and eventually the necessary R&D to address their feasibility. It best benefits from the extensive R&D that has been performed for conventional rf linear colliders during the last twenty years, especially ILC[ ] and CLIC[ ], with a potential for a comparably lower power consumption and cost.


Plasma Physics and Controlled Fusion | 2014

Laser ionized preformed plasma at FACET

Selina Green; E. Adli; Christine Clarke; S. Corde; S A Edstrom; A S Fisher; J. Frederico; J C Frisch; Spencer Gessner; S Gilevich; P Hering; Mark Hogan; R K Jobe; M. Litos; J E May; D. Walz; V. Yakimenko; C. E. Clayton; C. Joshi; K. A. Marsh; N. Vafaei-Najafabadi; P. Muggli

The Facility for Advanced Accelerator and Experimental Tests (FACET) at SLAC installed a 10-TW Ti : sapphire laser system for pre-ionized plasma wakefield acceleration experiments. High energy (500 mJ), short (50 fs) pulses of 800 nm laser light at 1 Hz are used at the FACET experimental area to produce a plasma column. The laser pulses are stretched to 250 fs before injection into a vapor cell, where the laser is focused by an axicon lens to form a plasma column that can be sustained over the desired radius and length. A 20 GeV electron bunch interacts with this preformed plasma to generate a non-linear wakefield, thus accelerating a trailing witness bunch with gradients on the order of several GV m−1. The experimental setup and the methods for producing the pre-ionized plasma for plasma wakefield acceleration experiments performed at FACET are described.


Nature Communications | 2016

Demonstration of a positron beam-driven hollow channel plasma wakefield accelerator

Spencer Gessner; E. Adli; J. Allen; Weiming An; Christine Clarke; C. E. Clayton; S. Corde; Jean-Pierre Delahaye; J. Frederico; Selina Green; C. Hast; Mark Hogan; C. Joshi; Carl Lindstrøm; Nate Lipkowitz; M. Litos; Wei Lu; Kenneth A. Marsh; W. B. Mori; Brendan O’Shea; N. Vafaei-Najafabadi; D. Walz; V. Yakimenko; Gerald Yocky

Plasma wakefield accelerators have been used to accelerate electron and positron particle beams with gradients that are orders of magnitude larger than those achieved in conventional accelerators. In addition to being accelerated by the plasma wakefield, the beam particles also experience strong transverse forces that may disrupt the beam quality. Hollow plasma channels have been proposed as a technique for generating accelerating fields without transverse forces. Here we demonstrate a method for creating an extended hollow plasma channel and measure the wakefields created by an ultrarelativistic positron beam as it propagates through the channel. The plasma channel is created by directing a high-intensity laser pulse with a spatially modulated profile into lithium vapour, which results in an annular region of ionization. A peak decelerating field of 230 MeV m−1 is inferred from changes in the beam energy spectrum, in good agreement with theory and particle-in-cell simulations.


Plasma Physics and Controlled Fusion | 2016

9 GeV energy gain in a beam-driven plasma wakefield accelerator

M. Litos; E. Adli; J. Allen; Weiming An; Christine Clarke; S. Corde; C. E. Clayton; J. Frederico; Spencer Gessner; Selina Green; Mark Hogan; C. Joshi; Wei Lu; K. A. Marsh; W. B. Mori; M Schmeltz; N. Vafaei-Najafabadi; V. Yakimenko

An electron beam has gained a maximum energy of 9 GeV per particle in a 1.3 m-long electron beam-driven plasma wakefield accelerator. The amount of charge accelerated in the spectral peak was 28.3 pC, and the root-mean-square energy spread was 5.0%. The mean accelerated charge and energy gain per particle of the 215 shot data set was 115 pC and 5.3 GeV, respectively, corresponding to an acceleration gradient of 4.0 GeV/m at the spectral peak. The mean energy spread of the data set was 5.1%. These results are consistent with the extrapolation of the previously reported energy gain results using a shorter, 36 cm-long plasma source to within 10%, evincing a non-evolving wake structure that can propagate distances of over a meter in length. Wake-loading effects were evident in the data through strong dependencies observed between various spectral properties and the amount of accelerated charge.


Scientific Reports | 2017

Acceleration of a trailing positron bunch in a plasma wakefield accelerator

Antoine Doche; C. Beekman; S. Corde; J. Allen; Christine Clarke; J. Frederico; Spencer Gessner; Selina Green; Mark Hogan; Brendan O’Shea; V. Yakimenko; Weiming An; C. E. Clayton; C. Joshi; K. A. Marsh; W. B. Mori; N. Vafaei-Najafabadi; M. Litos; E. Adli; Carl Lindstrøm; Wei Lu

High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. In these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positron bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. The results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.


Nature Communications | 2016

Self-mapping the longitudinal field structure of a nonlinear plasma accelerator cavity

C. E. Clayton; E. Adli; J. Allen; Weiming An; Christine Clarke; S. Corde; J. Frederico; Spencer Gessner; Selina Green; M.J. Hogan; C. Joshi; M. Litos; W. Lu; K. A. Marsh; W. B. Mori; N. Vafaei-Najafabadi; X. L. Xu; V. Yakimenko

The preservation of emittance of the accelerating beam is the next challenge for plasma-based accelerators envisioned for future light sources and colliders. The field structure of a highly nonlinear plasma wake is potentially suitable for this purpose but has not been yet measured. Here we show that the longitudinal variation of the fields in a nonlinear plasma wakefield accelerator cavity produced by a relativistic electron bunch can be mapped using the bunch itself as a probe. We find that, for much of the cavity that is devoid of plasma electrons, the transverse force is constant longitudinally to within ±3% (r.m.s.). Moreover, comparison of experimental data and simulations has resulted in mapping of the longitudinal electric field of the unloaded wake up to 83 GV m−1 to a similar degree of accuracy. These results bode well for high-gradient, high-efficiency acceleration of electron bunches while preserving their emittance in such a cavity.


Nature Communications | 2016

High-field plasma acceleration in a high-ionization-potential gas

S. Corde; E. Adli; J. Allen; Weiming An; Christine Clarke; B Clausse; C. E. Clayton; Jean-Pierre Delahaye; J. Frederico; Spencer Gessner; Selina Green; M.J. Hogan; C. Joshi; M. Litos; W. Lu; K. A. Marsh; W. B. Mori; N. Vafaei-Najafabadi; D. Walz; V. Yakimenko

Plasma accelerators driven by particle beams are a very promising future accelerator technology as they can sustain high accelerating fields over long distances with high energy efficiency. They rely on the excitation of a plasma wave in the wake of a drive beam. To generate the plasma, a neutral gas can be field-ionized by the head of the drive beam, in which case the distance of acceleration and energy gain can be strongly limited by head erosion. Here we overcome this limit and demonstrate that electrons in the tail of a drive beam can be accelerated by up to 27 GeV in a high-ionization-potential gas (argon), boosting their initial 20.35 GeV energy by 130%. Particle-in-cell simulations show that the argon plasma is sustaining very high electric fields, of ∼150 GV m−1, over ∼20 cm. The results open new possibilities for the design of particle beam drivers and plasma sources.


New Journal of Physics | 2016

Long-range attraction of an ultrarelativistic electron beam by a column of neutral plasma

E. Adli; Carl Lindstrøm; J. Allen; Christine Clarke; J. Frederico; Spencer Gessner; Selina Green; Mark Hogan; M. Litos; Brendan O’Shea; V. Yakimenko; Weiming An; C. E. Clayton; K. A. Marsh; W. B. Mori; C. Joshi; N. Vafaei-Najafabadi; S. Corde; Wei Lu

We report on the experimental observation of the attraction of a beam of ultrarelativistic electrons towards a column of neutral plasma. In experiments performed at the FACET test facility at SLAC we observe that an electron beam moving parallel to a neutral plasma column, at an initial distance of many plasma column radii, is attracted into the column. Once the beam enters the plasma it drives a plasma wake similar to that of an electron beam entering the plasma column head-on. A simple analytical model is developed in order to capture the essential physics of the attractive force. The attraction is further studied by 3D particle-in-cell numerical simulations. The results are an important step towards better understanding of particle beam–plasma interactions in general and plasma wakefield accelerator technology in particular.


Journal of Physics: Conference Series | 2018

Commissioning of beam instrumentation at the CERN AWAKE facility after integration of the electron beam line

Ishkhan Gorgisyan; Stefano Mazzoni; Stephane Burger; L. Jensen; Steen Jensen; David Medina; Manfred Wendt; Lars Søby; E. Gschwendtner; Spencer Gessner; S. Doebert; Kevin Pepitone; Chiara Bracco; Francesco Velotti; F. Keeble; M. Wing; S. Jolly; Michele Cascella; V. Verzilov

The Advanced Proton Driven Plasma Wakefield Acceleration Experiment (AWAKE) is a project at CERN aiming to accelerate an electron bunch in a plasma wakefield driven by a proton bunch. The plasma is induced in a 10 m long rubidium vapor cell using a pulsed Ti:Sapphire laser, with the wakefield formed by a proton bunch from the CERN Super Proton Synchrotron (SPS). A 16 MeV electron bunch is simultaneously injected into the plasma cell to be accelerated by the wakefield to energies in the GeV range over this short distance. After successful runs with the proton and laser beams, the electron beam line was installed and commissioned at the end of 2017 to produce and inject a suitable electron bunch into the plasma cell. To achieve the goals of the experiment, it is important to have reliable beam instrumentation measuring the various parameters of the proton, electron and laser beams. This contribution presents the status of the beam instrumentation in AWAKE and reports on the performance achieved during the AWAKE runs in 2017.

Collaboration


Dive into the Spencer Gessner's collaboration.

Top Co-Authors

Avatar

C. Joshi

University of California

View shared research outputs
Top Co-Authors

Avatar

M. Litos

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

W. B. Mori

University of California

View shared research outputs
Top Co-Authors

Avatar

C. E. Clayton

University of California

View shared research outputs
Top Co-Authors

Avatar

J. Frederico

SLAC National Accelerator Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Weiming An

University of California

View shared research outputs
Top Co-Authors

Avatar

S. Corde

Université Paris-Saclay

View shared research outputs
Top Co-Authors

Avatar

Christine Clarke

SLAC National Accelerator Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge