Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Stefan König is active.

Publication


Featured researches published by Stefan König.


Drug Testing and Analysis | 2014

Rapid and simple LC-MS/MS-Screening of 64 novel psychoactive substances using dried blood spots

Lars Ambach; Ana Hernández Redondo; Stefan König; Wolfgang Weinmann

The range of novel psychoactive substances (NPS) including phenethylamines, cathinones, piperazines, tryptamines, etc. is continuously growing. Therefore, fast and reliable screening methods for these compounds are essential and needed. The use of dried blood spots (DBS) for a fast straightforward approach helps to simplify and shorten sample preparation significantly. DBS were produced from 10 µl of whole blood and extracted offline with 500 µl methanol followed by evaporation and reconstitution in mobile phase. Reversed-phase chromatographic separation and mass spectrometric detection (RP-LC-MS/MS) was achieved within a run time of 10 min. The screening method was validated by evaluating the following parameters: limit of detection (LOD), matrix effect, selectivity and specificity, extraction efficiency, and short-term and long-term stability. Furthermore, the method was applied to authentic samples and results were compared with those obtained with a validated whole blood method used for routine analysis of NPS. LOD was between 1 and 10 ng/ml. No interference from matrix compounds was observed. The method was proven to be specific and selective for the analytes, although with limitations for 3-FMC/flephedrone and MDDMA/MDEA. Mean extraction efficiency was 84.6 %. All substances were stable in DBS for at least a week when cooled. Cooling was essential for the stability of cathinones. Prepared samples were stable for at least 3 days. Comparison to the validated whole blood method yielded similar results. DBS were shown to be useful in developing a rapid screening method for NPS with simplified sample preparation.


Drug Testing and Analysis | 2014

Pharmacokinetics of GHB and detection window in serum and urine after single uptake of a low dose of GBL – an experiment with two volunteers

Alexandra Schröck; Yvonne Hari; Stefan König; Volker Auwärter; Stefan Schürch; Wolfgang Weinmann

During the last few years γ-hydroxybutyric acid (GHB) and γ-butyrolactone (GBL) have attracted much interest as recreational drugs and knock-out drops in drug-facilitated sexual assaults. This experiment aims at getting an insight into the pharmacokinetics of GHB after intake of GBL. Therefore Two volunteers took a single dose of 1.5 ml GBL, which had been spiked to a soft drink. Assuming that GBL was completely metabolized to GHB, the corresponding amount of GHB was 2.1 g. Blood and urine samples were collected 5 h and 24 h after ingestion, respectively. Additionally, hair samples (head hair and beard hair) were taken within four to five weeks after intake of GBL. Samples were analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after protein precipitation with acetonitrile. The following observations were made: spiked to a soft drink, GBL, which tastes very bitter, formed a liquid layer at the bottom of the glass, only disappearing when stirring. Both volunteers reported weak central effects after approximately 15 min, which disappeared completely half an hour later. Maximum concentrations of GHB in serum were measured after 20 min (95 µg/ml and 106 µg/ml). Already after 4-5 h the GHB concentrations in serum decreased below 1 µg/ml. In urine maximum GHB concentrations (140 µg/ml and 120 µg/ml) were measured after 1-2 h, and decreased to less than 1 µg/ml within 8-10 h. The ratio of GHB in serum versus blood was 1.2 and 1.6.


Forensic Science International | 2014

Simultaneous quantification of delta-9-THC, THC-acid A, CBN and CBD in seized drugs using HPLC-DAD

Lars Ambach; Franziska Penitschka; Alain Broillet; Stefan König; Wolfgang Weinmann; Werner Bernhard

An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).


Forensic Science International | 2014

Determination of Δ9-tetrahydrocannabinolic acid A (Δ9-THCA-A) in whole blood and plasma by LC–MS/MS and application in authentic samples from drivers suspected of driving under the influence of cannabis

Nikolaos Raikos; Helene Schmid; Susanne Nussbaumer; Lars Ambach; Stephan Lanz; Andreas Längin; Stefan König; Nadine Roth; Volker Auwärter; Wolfgang Weinmann

Delta-9-tetrahydrocannabinolic acid A (THCA-A) is the biosynthetic precursor of delta-9-tetrahydrocannabinol (THC) in cannabis plants, and has no psychotropic effects. THCA-A can be detected in blood and urine, and several metabolites have been identified. THCA-A was also shown to be incorporated in hair by side stream smoke to a minor extent, but incorporation via blood stream or sweat seems unlikely. The detection of THCA-A in biological fluids may serve as a marker for differentiating between the intake of prescribed THC medication - containing only pure THC - and cannabis products containing THC besides THC-acid A and other cannabinoids. However, the knowledge about its usefulness in forensic cases is very limited. The aim of the present work was the development of a reliable method for THCA-A determination in human blood or plasma using LC-MS/MS and application to cases of driving under the influence of drugs. Fifty eight (58) authentic whole blood and the respective plasma samples were collected from drivers suspected of driving under the influence of cannabis from the region of Bern (Switzerland). Samples were first tested for THC, 11-OH-THC and THC-COOH, and then additionally for THCA-A. For this purpose, the existing LC-MS/MS method was modified and validated, and found to be selective and linear over a range of 1.0 to 200ng/mL (the correlation coefficients were above 0.9980 in all validation runs). Limit of detection (LOD) and limit of quantification (LOQ) were 0.3ng/mL and 1.0ng/mL respectively. Intra- and inter-assay accuracy were equal or better than 90% and intra- and inter-assay precision were equal or better than 11.1%. The mean extraction efficiencies were satisfactory being equal or higher than 85.4%. THCA-A was stable in whole blood samples after 3 freeze/thaw cycles and storage at 4°C for 7 days. Re-injection (autosampler) stability was also satisfactory. THC was present in all blood samples with levels ranging from 0.7 to 51ng/mL. THCA-A concentrations ranged from 1.0 to 496ng/mL in blood samples and from 1.4 to 824ng/mL in plasma samples. The plasma:blood partition coefficient had a mean value of 1.7 (±0.21, SD). No correlation was found between the degree of intoxication or impairment stated in the police protocols or reports of medical examinations and the detected THCA-A-concentration in blood.


Bioanalysis | 2017

Rapid quantification of free and glucuronidated THCCOOH in urine using coated well plates and LC–MS/MS analysis

Marianne Hädener; Wolfgang Weinmann; Dave R van Staveren; Stefan König

AIM Generally, urine drug testing for cannabis abuse involves measuring total concentrations of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) obtained by enzymatic and/or alkaline hydrolysis of THCCOOH-glucuronide. As hydrolysis can be inconsistent and incomplete, direct measurement of the two metabolites is preferable. Methodology & results: We developed a high-throughput LC-MS/MS method for simultaneous quantification of free and glucuronidated THCCOOH in urine using coated 96-well plates for analyte extraction and column-switching chromatography. Excellent separation of the two analytes was achieved within 2.5 min, with linear ranges from 5 to 2000 μg/l for THCCOOH and from 10 to 4000 μg/l for THCCOOH-glucuronide. CONCLUSION The method was successfully validated and applied to authentic urine samples from cannabis consumers, demonstrating its applicability for routine cannabinoid testing.


Journal of Analytical Toxicology | 2013

A Quantitative Phenytoin GC–MS Method and its Validation for Samples from Human ex situ Brain Microdialysis, Blood and Saliva Using Solid-Phase Extraction

Raphael Hösli; Andrea Tobler; Stefan König; Stefan Mühlebach

This study describes the development and validation of a gas chromatography-mass spectrometry (GC-MS) method to identify and quantitate phenytoin in brain microdialysate, saliva and blood from human samples. A solid-phase extraction (SPE) was performed with a nonpolar C8-SCX column. The eluate was evaporated with nitrogen (50°C) and derivatized with trimethylsulfonium hydroxide before GC-MS analysis. As the internal standard, 5-(p-methylphenyl)-5-phenylhydantoin was used. The MS was run in scan mode and the identification was made with three ion fragment masses. All peaks were identified with MassLib. Spiked phenytoin samples showed recovery after SPE of ≥94%. The calibration curve (phenytoin 50 to 1,200 ng/mL, n = 6, at six concentration levels) showed good linearity and correlation (r² > 0.998). The limit of detection was 15 ng/mL; the limit of quantification was 50 ng/mL. Dried extracted samples were stable within a 15% deviation range for ≥4 weeks at room temperature. The method met International Organization for Standardization standards and was able to detect and quantify phenytoin in different biological matrices and patient samples. The GC-MS method with SPE is specific, sensitive, robust and well reproducible, and is therefore an appropriate candidate for the pharmacokinetic assessment of phenytoin concentrations in different human biological samples.


Drug Testing and Analysis | 2017

Assessing cannabis consumption frequency: is the combined use of free and glucuronidated THCCOOH blood levels of diagnostic utility?

Marianne Hädener; Marie Fabritius; Stefan König; Christian Giroud; Wolfgang Weinmann

Heavy cannabis consumption is considered incompatible with safe driving. In Swiss traffic policy, drivers suspected of regular cannabis use are therefore required to undergo medical assessment of their long-term fitness to drive. A whole blood concentration of the cannabis metabolite 11-nor-9-carboxy-Δ9 -tetrahydrocannabinol (THCCOOH) of 40 µg/L is currently used by Swiss forensic experts as the decision limit for regular cannabis consumption. The present study aimed to investigate the suitability of THCCOOH-glucuronide blood levels as an additional and/or better marker for the frequency of cannabis use. Whole blood samples collected from 23 heavy (≥10 joints/month) and 25 occasional smokers (≥1 joint/month, but ≤ 1 joint/week) enrolled in a placebo-controlled cannabis smoking study were analyzed for THCCOOH and THCCOOH-glucuronide. Based on receiver operating characteristic (ROC) curve analysis, concentration thresholds could be established for distinguishing between these two groups. Proposed thresholds for heavy use were THCCOOH-glucuronide > 52 µg/L (100% specificity; 41% sensitivity) and/or total THCCOOH > 58 µg/L (100% specificity; 43% sensitivity). Optimum thresholds for occasional use were THCCOOH-glucuronide < 5 µg/L (73% specificity; 97% sensitivity) and/or total THCCOOH < 5 µg/L (62% specificity; 98% sensitivity). Our results indicate that the THCCOOH-glucuronide whole blood concentration is a useful parameter that complements the free THCCOOH level to assess the frequency of cannabis consumption. The consideration of the blood concentrations of both free and glucuronidated THCCOOH improves the identification of heavy users whose fitness to drive has to be carefully assessed. Copyright


Bioanalysis | 2014

Electrochemical simulation of phase I metabolism for 21 drugs using four different working electrodes in an automated screening setup with MS detection

Anders Just Pedersen; Lars Ambach; Stefan König; Wolfgang Weinmann

BACKGROUND Electrochemical conversion of xenobiotics has been shown to mimic human phase I metabolism for a few compounds. MATERIALS & METHODS Twenty-one compounds were analyzed with a semiautomated electrochemical setup and mass spectrometry detection. RESULTS The system was able to mimic some metabolic pathways, such as oxygen gain, dealkylation and deiodination, but many of the expected and known metabolites were not produced. CONCLUSION Electrochemical conversion is a useful approach for the preparative synthesis of some types of metabolites, but as a screening method for unknown phase I metabolites, the method is, in our opinion, inferior to incubation with human liver microsomes and in vivo experiments with laboratory animals, for example.


Journal of Automated Methods & Management in Chemistry | 2018

Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

Raphael Hösli; Stefan König; Stefan Mühlebach

Phenytoin (PHT) is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva) and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL) and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis), and resulted in a better LOD (<1 ng/mL)/LOQ (10 ng/mL). The calibration curve of the LC-MS/MS method (10–2000 ng/mL) showed linearity over a larger range with correlation coefficients r2 > 0.995 for all tested matrices (blood, saliva, and dialysate). For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.


Forensic Science International | 2018

Analysis of volatiles in fire debris by combination of activated charcoal strips (ACS) and automated thermal desorption–gas chromatography–mass spectrometry (ATD/GC–MS)

Marie Claire Michèle Fabritius; Alain Broillet; Stefan König; Wolfgang Weinmann

Adsorption of volatiles in gaseous phase to activated charcoal strip (ACS) is one possibility for the extraction and concentration of ignitable liquid residues (ILRs) from fire debris in arson investigations. Besides liquid extraction using carbon dioxide or hexane, automated thermo-desorption can be used to transfer adsorbed residues to direct analysis by gas chromatography-mass spectrometry (GC-MS). We present a fire debris analysis work-flow with headspace adsorption of volatiles onto ACS and subsequent automated thermo-desorption (ATD) GC-MS analysis. Only a small portion of the ACS is inserted in the ATD tube for thermal desorption coupled to GC-MS, allowing for subsequent confirmation analysis with another portion of the same ACS. This approach is a promising alternative to the routinely used ACS method with solvent extraction of retained volatiles, and the application to fire debris analysis is demonstrated.

Collaboration


Dive into the Stefan König's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge