Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Stefan Maenz is active.

Publication


Featured researches published by Stefan Maenz.


Journal of The Mechanical Behavior of Biomedical Materials | 2014

Enhanced mechanical properties of a novel, injectable, fiber-reinforced brushite cement.

Stefan Maenz; Elke Kunisch; Mike Mühlstädt; Anne Böhm; Victoria Kopsch; Jörg Bossert; Raimund W. Kinne; Klaus D. Jandt

Injectable, brushite-forming calcium phosphate cements (CPCs) have great potential as bone replacement materials due to enhanced degradability and long-term inclusion in bone remodeling. However, the use of such brushite-forming CPCs in load-bearing areas is limited by their low mechanical strength. One approach to overcome this limitation is the use of reinforcing fibers. Thus, an injectable, biodegradable, brushite-forming CPC based on beta-tricalcium phosphate/phosphoric acid with fiber reinforcement was developed for minimally invasive surgery. The fibers (diameter 25 µm; length 0.25, 1 or 2mm) were extruded from poly(l-lactide-co-glycolide) acid (PLGA) and added to the CPC (2.5, 5 or 7.5% (w/w)). Independent of the fiber content, injectability of the CPC was retained up to a fiber length of 1mm. The addition of all PLGA fiber types increased diametral tensile strength, biaxial flexural strength, and flexural strength by up to 25% (p ≤ 0.05 for the diametral tensile strength for the CPC with 5% (w/w) 1mm fibers and the biaxial flexural strength of the CPC with 5% (w/w) 0.25 mm fibers). In contrast, the work of fracture strongly and significantly increased (p<0.01) by up to 12.5-fold. At constant fiber content, the mechanical properties of the fiber-reinforced CPC were mostly augmented with increasing fiber length. Also, the addition of PLGA fibers to the brushite-forming CPC (up to 7.5% (w/w)) only transiently delayed cell growth and did not decrease cell viability. Fiber reinforcement of CPCs thus augments their mechanical strength while preserving the injectability and biocompatibility required for their application in modern surgery.


The Spine Journal | 2016

Decreased extrusion of calcium phosphate cement versus high viscosity PMMA cement into spongious bone marrow—an ex vivo and in vivo study in sheep vertebrae

Long Xin; Matthias Bungartz; Stefan Maenz; Victoria Horbert; Max Hennig; Bernhard Illerhaus; Jens Günster; Jörg Bossert; Sabine Bischoff; Juliane Borowski; Harald Schubert; Klaus D. Jandt; Elke Kunisch; Raimund W. Kinne; Olaf Brinkmann

BACKGROUND CONTEXT Vertebroplasty or kyphoplasty of osteoporotic vertebral fractures bears the risk of pulmonary cement embolism (3.5%-23%) caused by leakage of commonly applied acrylic polymethylmethacrylate (PMMA) cement to spongious bone marrow or outside of the vertebrae. Ultraviscous cement and specific augmentation systems have been developed to reduce such adverse effects. Rapidly setting, resorbable, physiological calcium phosphate cement (CPC) may also represent a suitable alternative. PURPOSE This study aimed to compare the intravertebral extrusion of CPC and PMMA cement in an ex vivo and in vivo study in sheep. STUDY DESIGN/SETTING A prospective experimental animal study was carried out. METHODS Defects (diameter 5 mm; 15 mm depth) were created by a ventrolateral percutaneous approach in lumbar vertebrae of female Merino sheep (2-4 years) either ex vivo (n=17) or in vivo (n=6), and injected with: (1) CPC (L3); (2) CPC reinforced with 10% poly(l-lactide-co-glycolide) (PLGA) fibers (L4); or (3) PMMA cement (L5; Kyphon HV-R). Controls were untouched (L1) or empty defects (L2). The effects of the cement injections were assessed in vivo by blood gas analysis and ex vivo by computed tomography (CT), micro-CT (voxel size: 67 µm), histology, and biomechanical testing. RESULTS Following ex vivo injection, micro-CT documented significantly increased extrusion of PMMA cement in comparison to CPC (+/- fibers) starting at a distance of 1 mm from the edge of the defect (confirmed by histology); this was also demonstrated by micro-CT following in vivo cement injection. In addition, blood gas analysis showed consistently significantly lower values for the fraction of oxygenized hemoglobin/total hemoglobin (FO2Hb) in the arterial blood until 25 minutes following injection of the PMMA cement (p ≤ .05 vs. CPC; 7, 15 minutes). Biomechanical testing following ex vivo injection showed significantly lower compressive strength and Young modulus than untouched controls for the empty defect (40% and 34% reduction, respectively) and all three cement-injected defects (21%-27% and 29%-32% reduction, respectively), without significant differences among the cements. CONCLUSIONS Because of comparable compressive strength, but significantly lower cement extrusion into spongious bone marrow than PMMA cement, physiological CPC (+/- PLGA fibers) may represent an attractive alternative to PMMA for vertebroplasty or kyphoplasty of osteoporotic vertebral fractures to reduce the frequency or severity of adverse effects.


The Spine Journal | 2017

Enhanced bone formation in sheep vertebral bodies after minimally invasive treatment with a novel, PLGA fiber-reinforced brushite cement.

Stefan Maenz; Olaf Brinkmann; Elke Kunisch; Victoria Horbert; Francesca Gunnella; Sabine Bischoff; Harald Schubert; Andre Sachse; Long Xin; Jens Günster; Bernhard Illerhaus; Klaus D. Jandt; Jörg Bossert; Raimund W. Kinne; Matthias Bungartz

BACKGROUND CONTEXT Injectable, brushite-forming calcium phosphate cements (CPC) show potential for bone replacement, but they exhibit low mechanical strength. This study tested a CPC reinforced with poly(l-lactide-co-glycolide) acid (PLGA) fibers in a minimally invasive, sheep lumbar vertebroplasty model. PURPOSE The study aimed to test the in vivo biocompatibility and osteogenic potential of a PLGA fiber-reinforced, brushite-forming CPC in a sheep large animal model. STUDY DESIGN/SETTING This is a prospective experimental animal study. METHODS Bone defects (diameter: 5 mm) were placed in aged, osteopenic female sheep, and left empty (L2) or injected with pure CPC (L3) or PLGA fiber-reinforced CPC (L4; fiber diameter: 25 µm; length: 1 mm; 10% [wt/wt]). Three and 9 months postoperation (n=20 each), the structural and functional CPC effects on bone regeneration were documented ex vivo by osteodensitometry, histomorphometry, micro-computed tomography (micro-CT), and biomechanical testing. RESULTS Addition of PLGA fibers enhanced CPC osteoconductivity and augmented bone formation. This was demonstrated by (1) significantly enhanced structural (bone volume/total volume, shown by micro-CT and histomorphometry; 3 or 9 months) and bone formation parameters (osteoid volume and osteoid surface; 9 months); (2) numerically enhanced bone mineral density (3 and 9 months) and biomechanical compression strength (9 months); and (3) numerically decreased bone erosion (eroded surface; 3 and 9 months). CONCLUSIONS The PLGA fiber-reinforced CPC is highly biocompatible and its PLGA fiber component enhanced bone formation. Also, PLGA fibers improve the mechanical properties of brittle CPC, with potential applicability in load-bearing areas.


The Spine Journal | 2016

First-time systematic postoperative clinical assessment of a minimally invasive approach for lumbar ventrolateral vertebroplasty in the large animal model sheep

Matthias Bungartz; Stefan Maenz; Elke Kunisch; Victoria Horbert; Long Xin; Francesca Gunnella; Joerg Mika; Juliane Borowski; Sabine Bischoff; Harald Schubert; Andre Sachse; Bernhard Illerhaus; Jens Günster; Jörg Bossert; Klaus D. Jandt; Raimund W. Kinne; Olaf Brinkmann

BACKGROUND CONTEXT Large animal models are highly recommended for meaningful preclinical studies, including the optimization of cement augmentation for vertebral body defects by vertebroplasty/kyphoplasty. PURPOSE The aim of this study was to perform a systematic characterization of a strictly minimally invasive in vivo large animal model for lumbar ventrolateral vertebroplasty. STUDY DESIGN/ SETTING This is a prospective experimental animal study. METHODS Lumbar defects (diameter 5 mm; depth approximately 14 mm) were created by a ventrolateral percutaneous approach in aged, osteopenic, female sheep (40 Merino sheep; 6-9 years; 68-110 kg). L1 remained untouched, L2 was left with an empty defect, and L3 carried a defect injected with a brushite-forming calcium phosphate cement (CPC). Trauma/functional impairment, surgical techniques (including drill sleeve and working canula with stop), reproducibility, bone defects, cement filling, and functional cement augmentation were documented by intraoperative incision-to-suture time and X-ray, postoperative trauma/impairment scores, and ex vivo osteodensitometry, microcomputed tomography (CT), histology, static/fluorescence histomorphometry, and biomechanical testing. RESULTS Minimally invasive vertebroplasty resulted in short operation times (28±2 minutes; mean±standard error of the mean) and X-ray exposure (1.59±0.12 minutes), very limited local trauma (score 0.00±0.00 at 24 hours), short postoperative recovery (2.95±0.29 hours), and rapid decrease of the postoperative impairment score to 0 (3.28±0.36 hours). Reproducible defect creation and cement filling were documented by intraoperative X-ray and ex vivo conventional/micro-CT. Vertebral cement augmentation and osteoconductivity of the CPC was verified by osteodensitometry (CPC>control), micro-CT (CPC>control and empty defect), histology/static histomorphometry (CPC>control and empty defect), fluorescence histomorphometry (CPC>control; all p<.05 for 3 and 9 months), and compressive strength measurements (CPC numerically higher than control; 102% for 3 months and 110% for 9 months). CONCLUSIONS This first-time systematic clinical assessment of a minimally invasive, ventrolateral, lumbar vertebroplasty model in aged, osteopenic sheep resulted in short operation times, rapid postoperative recovery, and high experimental reproducibility. This model represents an optimal basis for standardized evaluation of future studies on vertebral augmentation with resorbable and osteoconductive CPC.


Journal of The Mechanical Behavior of Biomedical Materials | 2016

Effects of oxygen plasma treatment on interfacial shear strength and post-peak residual strength of a PLGA fiber-reinforced brushite cement.

Stefan Maenz; Max Hennig; Mike Mühlstädt; Elke Kunisch; Matthias Bungartz; Olaf Brinkmann; Jörg Bossert; Raimund W. Kinne; Klaus D. Jandt

Biodegradable calcium phosphate cements (CPCs) are promising materials for minimally invasive treatment of bone defects. However, CPCs have low mechanical strength and fracture toughness. One approach to overcome these limitations is the modification of the CPC with reinforcing fibers. The matrix-fiber interfacial shear strength (ISS) is pivotal for the biomechanical properties of fiber-reinforced CPCs. The aim of the current study was to control the ISS between a brushite-forming CPC and degradable PLGA fibers by oxygen plasma treatment and to analyze the impact of the ISS alterations on its bulk mechanical properties. The ISS between CPC matrix and PLGA fibers, tested in a single-fiber pull-out test, increased up to 2.3-fold to max. 3.22±0.92MPa after fiber oxygen plasma treatment (100-300W, 1-10min), likely due to altered surface chemistry and morphology of the fibers. This ISS increase led to more efficient crack bridging and a subsequent increase of the post-peak residual strength at biomechanically relevant, moderate strains (up to 1%). At the same time, the work of fracture significantly decreased, possibly due to an increased proportion of fractured fibers unable to further absorb energy by frictional sliding. Flexural strength and flexural modulus were not affected by the oxygen plasma treatment. This study shows for the first time that the matrix-fiber ISS and some of the resulting mechanical properties of fiber-reinforced CPCs can be improved by chemical modifications such as oxygen plasma treatment, generating the possibility of avoiding catastrophic failures at the implant site and thus enhancing the applicability of biodegradable CPCs for the treatment of (load-bearing) bone defects.


Journal of Composite Materials | 2015

Mechanical properties of microwave cured glass fibre epoxy composites prepared by resin transfer moulding

Stefan Maenz; Mike Mühlstädt; Klaus D. Jandt; Jörg Bossert

The aim of this study was to significantly reduce the curing time for glass fibre epoxy composites in industrial relevant dimensions without worsening of the mechanical properties. With the combination of microwave heating and resin transfer moulding (RTM), the time between filling the mould and demoulding the samples was reduced to only 1 h and 15 min compared to at least 6 h for conventional curing of the same material. Based on the different dielectric losses of cured and uncured resin a pulsed microwave process was developed. In this way homogenously cured samples were obtained. Tensile strength, flexural strength, flexural modulus of elasticity and Charpy impact strength of microwave cured samples were compared to conventionally cured samples. No statistically significant differences were found. Thus, microwave curing shows a high potential to improve the efficiency of fibre composite production while maintaining the mechanical properties.


Colloids and Surfaces B: Biointerfaces | 2016

Hemodynamic aspects of reduced platelet adhesion on bioinspired microstructured surfaces.

Tam Thanh Pham; Stefan Wiedemeier; Stefan Maenz; Gunter Gastrock; Utz Settmacher; Klaus D. Jandt; Jürgen Zanow; Claudia Lüdecke; Jörg Bossert

Occlusion by thrombosis due to the absence of the endothelial cell layer is one of the most frequent causes of failure of artificial vascular grafts. Bioinspired surface structures may have a potential to reduce the adhesion of platelets contributing to hemostasis. The aim of this study was to investigate the hemodynamic aspects of platelet adhesion, the main cause of thrombosis, on bioinspired microstructured surfaces mimicking the endothelial cell morphology. We tested the hypothesis that platelet adhesion is statistically significantly reduced on bioinspired microstructured surfaces compared to unstructured surfaces. Platelet adhesion as a function of the microstructure dimensions was investigated under flow conditions on polydimethylsiloxane (PDMS) surfaces by a combined experimental and theoretical approach. Platelet adhesion was statistically significantly reduced (by up to 78%; p≤0.05) on the microstructured PDMS surfaces compared to that on the unstructured control surface. Finite element method (FEM) simulations of blood flow dynamic revealed a micro shear gradient on the microstructure surfaces which plays a pivotal role in reducing platelet adhesion. On the surfaces with the highest differences of the shear stress between the top of the microstructures and the ground areas, platelet adhesion was reduced most. In addition, the microstructures help to reduce the interaction strength between fluid and surfaces, resulting in a larger water contact angle but no higher resistance to flow compared to the unstructured surface. These findings provide new insight into the fundamental mechanisms of reducing platelet adhesion on microstructured bioinspired surfaces and may lay the basis for the development of innovative next generation artificial vascular grafts with reduced risk of thrombosis.


Tissue & Cell | 2015

Quantitative characterization of endothelial cell morphologies depending on shear stress in different blood vessels of domestic pigs using a focused ion beam and high resolution scanning electron microscopy (FIB-SEM)

Tam Thanh Pham; Stefan Maenz; Claudia Lüdecke; Christoph Schmerbauch; Utz Settmacher; Klaus D. Jandt; Jörg Bossert; Jürgen Zanow

Microstructured surfaces mimicking the endothelial cell (EC) morphology is a new approach to improve the blood compatibility of synthetic vascular grafts. The ECs are capable of changing their shapes depending on different shear conditions. However, the quantitative correlation between EC morphology and shear stress has not yet been investigated statistically. The aim of this study was to quantitatively investigate the morphology of ECs in dependence on the shear stress. Blood flow rates in different types of natural blood vessels (carotid, renal, hepatic and iliac arteries) originated from domestic pigs were first measured in vivo to calculate the shear stresses. The EC morphologies were quantitatively characterized ex vivo by imaging with high resolution scanning electron microscopy (SEM) and cross-sectioning of the cells using a state-of-the-art focused ion beam (FIB). The relationships between EC geometrical parameters and shear stress were statistically analyzed and found to be exponential. ECs under high shear stress conditions had a longer length and narrower width, i.e. a higher aspect ratio, while the cell height was smaller compared to low shear conditions. Based on these results, suitable and valid geometrical parameters of microstructures mimicking EC can be derived for various shear conditions in synthetic vascular grafts to optimize blood compatibility.


The Spine Journal | 2017

GDF5 significantly augments the bone formation induced by an injectable, PLGA fiber-reinforced, brushite-forming cement in a sheep defect model of lumbar osteopenia

Matthias Bungartz; Elke Kunisch; Stefan Maenz; Victoria Horbert; Long Xin; Francesca Gunnella; Joerg Mika; Juliane Borowski; Sabine Bischoff; Harald Schubert; Andre Sachse; Bernhard Illerhaus; Jens Günster; Jörg Bossert; Klaus D. Jandt; Frank Plöger; Raimund W. Kinne; Olaf Brinkmann

BACKGROUND CONTEXT Biodegradable calcium phosphate cement (CPC) represents a promising option for the surgical treatment of osteoporotic vertebral fractures. Because of augmented local bone catabolism, however, additional targeted delivery of bone morphogenetic proteins with the CPC may be needed to promote rapid and complete bone regeneration. PURPOSE In the present study, an injectable, poly(l-lactide-co-glycolide) acid (PLGA) fiber-reinforced, brushite-forming cement (CPC) containing the bone morphogenetic protein GDF5 was tested in a sheep lumbar osteopenia model. STUDY DESIGN/SETTING This is a prospective experimental animal study. METHODS Defined bone defects (diameter 5 mm) were placed in aged, osteopenic female sheep. Defects were treated with fiber-reinforced CPC alone (L4; CPC+fibers) or with CPC containing different dosages of GDF5 (L5; CPC+fibers+GDF5; 1, 5, 100, and 500 µg GDF5; n=5 or 6 each). The results were compared with those of untouched controls (L1). Three and 9 months postoperation, structural and functional effects of the CPC (±GDF5) were assessed ex vivo by measuring (1) bone mineral density (BMD); (2) bone structure, that is, bone volume/total volume (assessed by micro-computed tomography and histomorphometry), trabecular thickness, and trabecular number; (3) bone formation, that is, osteoid volume/bone volume, osteoid surface/bone surface, osteoid thickness, mineralized surface/bone surface, mineral apposition rate, and bone formation rate/bone surface; (4) bone resorption, that is, eroded surface/bone surface; and (5) compressive strength. RESULTS Compared with untouched controls (L1), both CPC+fibers (L4) and CPC+fibers+GDF5 (L5) numerically or significantly improved all parameters of bone formation, bone resorption, and bone structure. These significant effects were observed both at 3 and 9 months, but for some parameters they were less pronounced at 9 months. Compared with CPC without GDF5, additional significant effects of CPC with GDF5 were demonstrated for BMD and parameters of bone formation and structure (bone volume/total volume, trabecular thickness, and trabecular number, as well as mineralized surface/bone surface). The GDF5 effects were dose-dependent (predominantly in the 5-100 µg range) at 3 and 9 months. CONCLUSIONS GDF5 significantly enhanced the bone formation induced by a PLGA fiber-reinforced CPC in sheep lumbar osteopenia. The results indicated that a local dose as low as ≤100 µg GDF5 may be sufficient to augment middle to long-term bone formation. The novel CPC+GDF5 combination may thus qualify as an alternative to the bioinert, supraphysiologically stiff poly(methyl methacrylate) cement currently applied for vertebroplasty/kyphoplasty of osteoporotic vertebral fractures.


Dental Materials | 2016

Template assisted surface microstructuring of flowable dental composites and its effect on microbial adhesion properties

Nadja Frenzel; Stefan Maenz; Vanesa Sanz Beltrán; Andrea Völpel; Markus Heyder; Bernd W. Sigusch; Claudia Lüdecke; Klaus D. Jandt

OBJECTIVES Despite their various advantages, such as good esthetic properties, absence of mercury and adhesive bonding to teeth, modern dental composites still have some drawbacks, e.g., a relatively high rate of secondary caries on teeth filled with composite materials. Recent research suggests that microstructured biomaterials surfaces may reduce microbial adhesion to materials due to unfavorable physical material-microbe interactions. The objectives of this study were, therefore, to test the hypotheses that (i) different surface microstructures can be created on composites by a novel straightforward approach potentially suitable for clinical application and (ii) that these surface structures have a statistically significant effect on microbial adhesion properties. METHODS Six different dental composites were initially tested for their suitability for microstructuring by polydimethylsiloxane (PDMS) templates. Each composite was light-cured between a glass slide and a microstructured PDMS template. The nano-hybrid composite Grandio Flow was the only tested composite with satisfying structurability, and was therefore used for the bacterial adhesion tests. Composites samples were structured with four different microstructures (flat, cubes, linear trapezoid structures, flat pyramids) and incubated for 4h in centrifuged saliva. The bacterial adherence was then characterized by colony forming units (CFUs) and scanning electron microscopy (SEM). RESULTS All four microstructures were successfully transferred from the PDMS templates to the composite Grandio Flow. The CFU-test as well as the quantitative analysis of the SEM images showed the lowest bacterial adhesion on the flat composite samples. The highest bacterial adhesion was observed on the composite samples with linear trapezoid structures, followed by flat pyramids and cubes. The microstructure of dental composite surfaces statistically significantly influenced the adhesion of oral bacteria. SIGNIFICANCE Modifying the composite surface structure may be a clinically suitable approach to control the microbial adhesion and thus, to reduce the risk of secondary caries at dental composite restorations. Smaller composite surface structures may be useful for accomplishing this.

Collaboration


Dive into the Stefan Maenz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Bernhard Illerhaus

Bundesanstalt für Materialforschung und -prüfung

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge