Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Stéfani Iury E. Andrade is active.

Publication


Featured researches published by Stéfani Iury E. Andrade.


Talanta | 2011

A digital image-based method for determining of total acidity in red wines using acid–base titration without indicator

Adamastor R. Tôrres; Wellington da Silva Lyra; Stéfani Iury E. Andrade; Renato A.N. Andrade; Edvan Cirino da Silva; Mário César Ugulino de Araújo; Edvaldo N. Gaião

This work proposes the use of digital image-based method for determination of total acidity in red wines by means of acid-base titration without using an external indicator or any pre-treatment of the sample. Digital images present the colour of the emergent radiation which is complementary to the radiation absorbed by anthocyanines present in wines. Anthocyanines change colour depending on the pH of the medium, and from the variation of colour in the images obtained during titration, the end point can be localized with accuracy and precision. RGB-based values were employed to build titration curves, and end points were localized by second derivative curves. The official method recommends potentiometric titration with a NaOH standard solution, and sample dilution until the pH reaches 8.2-8.4. In order to illustrate the feasibility of the proposed method, titrations of ten red wines were carried out. Results were compared with the reference method, and no statistically significant difference was observed between the results by applying the paired t-test at the 95% confidence level. The proposed method yielded more precise results than the official method. This is due to the trivariate nature of the measurements (RGB), associated with digital images.


Talanta | 2012

Photometric determination of phosphorus in mineralized biodiesel using a micro-flow-batch analyzer with solenoid micro-pumps

Marcelo B. Lima; Inakã S. Barreto; Stéfani Iury E. Andrade; Maria S.S. Neta; Luciano F. Almeida; Mário César Ugulino de Araújo

A method for the determination of phosphorus in mineralized biodiesel using a micro-flow-batch analyzer (μFBA) with solenoid micro-pumps was proposed. The samples were mineralized using an ashing procedure at 550 °C followed by dissolution of the residue. The determination of phosphorus was performed by employing the well-known molybdenum blue method. The measures of the absorbance were performed at 850 nm using an InfraRed LED integrated into the μFBA. Comparing with the reference method, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. Recovery study shows results between 97.9% and 105.8%. The proposed microsystem using solenoid micro-pumps presented satisfactory robustness and high sampling rate (190 h(-1)), with satisfactory reproducibility (relative standard deviation <4.5%, n=3), low reagents consumption (32 μL per analysis) and cost to build the device. Moreover, μFBA presents limit of detection (0.014 mg Kg(-1)), precision and accuracy compatible with the biodiesel regulations that establish a maximum concentration of 10 mg Kg(-1) (Brazil, USA, EU), suggesting that it is a good alternative for the determination of phosphorus in biodiesel.


Talanta | 2012

Turbidimetric and photometric determination of total tannins in tea using a micro-flow-batch analyzer.

Marcelo B. Lima; Stéfani Iury E. Andrade; David P. Harding; Marcelo F. Pistonesi; Beatriz S. Fernández Band; Mário César Ugulino de Araújo

Both turbidimetric and photometric determinations of total tannins in samples of green and black tea, using a micro-flow-batch analyzer (μFBA) were studied. The miniaturized system was formed using photocurable urethane-acrylate resin and ultraviolet lithography technique. The turbidimetric method was based on the precipitation reaction of Cu (II) with tannins in acetate medium at a pH of 4.5. The photometric method was based on the complexation reaction of tannins with ferrous tartrate. The turbidimetric μFBA was able to test 200 samples per hour. The photometric μFBA allowed 300 analyses per hour, generating 136μL of residue per analysis. The paired t test, at a 95% confidence level, showed no statistically significant differences between results obtained by both methods and the reference method. The urethane-acrylate μFBA maintained satisfactory physical and chemical properties, and represents an improvement over conventional flow-batch analyzer.


Analytica Chimica Acta | 2011

A modification of the successive projections algorithm for spectral variable selection in the presence of unknown interferents

Sófacles Figueredo Carreiro Soares; Roberto Kawakami Harrop Galvão; Mário César Ugulino de Araújo; Edvan Cirino da Silva; Claudete Fernandes Pereira; Stéfani Iury E. Andrade; Flaviano Carvalho Leite

This work proposes a modification to the successive projections algorithm (SPA) aimed at selecting spectral variables for multiple linear regression (MLR) in the presence of unknown interferents not included in the calibration data set. The modified algorithm favours the selection of variables in which the effect of the interferent is less pronounced. The proposed procedure can be regarded as an adaptive modelling technique, because the spectral features of the samples to be analyzed are considered in the variable selection process. The advantages of this new approach are demonstrated in two analytical problems, namely (1) ultraviolet-visible spectrometric determination of tartrazine, allure red and sunset yellow in aqueous solutions under the interference of erythrosine, and (2) near-infrared spectrometric determination of ethanol in gasoline under the interference of toluene. In these case studies, the performance of conventional MLR-SPA models is substantially degraded by the presence of the interferent. This problem is circumvented by applying the proposed Adaptive MLR-SPA approach, which results in prediction errors smaller than those obtained by three other multivariate calibration techniques, namely stepwise regression, full-spectrum partial-least-squares (PLS) and PLS with variables selected by a genetic algorithm. An inspection of the variable selection results reveals that the Adaptive approach successfully avoids spectral regions in which the interference is more intense.


Talanta | 2012

A micro-flow-batch analyzer with solenoid micro-pumps for the photometric determination of iodate in table salt

Marcelo B. Lima; Inakã S. Barreto; Stéfani Iury E. Andrade; Luciano F. Almeida; Mário César Ugulino de Araújo

In this study, a micro-flow-batch analyzer (μFBA) with solenoid micro-pumps for the photometric determination of iodate in table salt is described. The method is based on the reaction of iodate with iodide to form molecular iodine followed by the reaction with N,N-diethyl-p-phenylenediamine (DPD). The analytical signal was measured at 520 nm using a green LED integrated into the μFBA built in the urethane-acrylate resin. The analytical curve for iodate was linear in the range of 0.01-10.0 mg L(-1) with a correlation coefficient of 0.997. The limit of detection and relative standard deviation were estimated at 0.004 mg L(-1) and<1.5% (n=3), respectively. The accuracy was assessed through recovery test (97.6-103.5%) and independent analysis by a conventional titrimetric method. Comparing this technique with the conventional method, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. The proposed microsystem using solenoid micro-pumps presented satisfactory robustness and high sampling rate (170 h(-1)), with a low reagents consumption and a low cost to build the device. The proposed microsystem is a new alternative for automatic determination of iodate in table salt, comparing satisfactory to the recently flow system.


Talanta | 2012

A monosegmented flow-batch system for slow reaction kinetics: Spectrophotometric determination of boron in plants

Inakã S. Barreto; Stéfani Iury E. Andrade; Marcelo B. Lima; Edvan Cirino da Silva; Mário César Ugulino de Araújo; Luciano F. Almeida

This work introduces the monosegmented flow-batch (MSFB) analysis concept. This system combines favourable characteristics of both flow-batch and the monosegmented analysers, allowing use of the flow-batch system for slow reaction kinetics without impairing sensitivity or sampling throughput. The MSFB was evaluated during spectrophotometric determination of boron in plant extracts, which is a method that involves a slow reaction between boron and azomethine-H. All calibration solutions were prepared in-line, and all analytical processes completed by simply changing the operational parameters in the MSFB control software. The limit of detection was estimated at 0.008 mg L(-1). The measurements could be performed at a rate of 120 samples per hour with satisfactory precision. The proposed MSFB was successfully applied to analyse 10 plant samples and the results are in agreement with the reference method at a 95% level of confidence.


Analytical Methods | 2013

Using a flow-batch analyzer for photometric determination of Fe(III) in edible and lubricating oils without external pretreatment

Inakã S. Barreto; Marcelo B. Lima; Stéfani Iury E. Andrade; Mário César Ugulino de Araújo; Luciano F. Almeida

In this study a flow-batch analyzer (FBA) was utilized and its feasibility was demonstrated for the determination of Fe(III) in edible and lubricating oils without external pretreatment. The FBA method uses the reaction of this ion with thiocyanate in organic medium. The formed red complex was monitored by employing a light emitting diode (LED, λmax = 520 nm) and a phototransistor linked to the mixing chamber by optical fibers. All standard solutions were prepared in-line and all analytical processes were carried out by simply changing the operational parameters in FBA control software. Comparing with the reference method, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. The relative standard deviation, analytical frequency and limit of detection were estimated for both viscous matrices (edible and lubricating oils) at <2.1% (n = 3), about 95 h−1, and 0.004 mg kg−1, respectively. The recovery study shows results between 97.8% and 103.6% for both matrices. The FBA method showed better analytical features when compared with previous automatic flow methods. Thus, the FBA is potentially useful as an alternative for the determination of other ions in similar samples or in other viscous matrices without external pretreatment.


Analytical Methods | 2015

In-line single-phase extraction for direct determination of total iron in oils using CdTe quantum dots and a flow-batch system

Marcelo B. Lima; Stéfani Iury E. Andrade; Inakã S. Barreto; Mário César Ugulino de Araújo

In this work, a novel method for direct determination of total iron in viscous samples (edible oils and biodiesel) is presented. Considering sensitivity and selectivity, the proposed method used in-line single-phase extraction and CdTe quantum dots (QDs). The method was automated employing a flow-batch system. The in-line single-phase extraction of iron consisted of the addition of a mixture of ethanol/chloroform (75 : 25, v/v) to dissolve the oil samples, followed by addition of an acid solution, HNO3/HCl (3 : 1, v/v) to make the iron available. The analytical method was based on iron capacity to establish surface interactions with CdTe QDs that result in quenching of their fluorescence intensity proportional to the iron concentration. Various factors that may influence the fluorescence quenching of iron, such as pH, sample volume, amount of the organic mixture, and acid solution concentration, were studied. The maximum reproducibility of this fluorescence quenching occurred at pH 7.5. Phosphate buffered saline (PBS) 1.0 mol L−1 was added before the reaction. Method validation and application to real samples showed that the analytical features of the developed method were quite satisfactory in terms of linearity (r2 = 0.997), limit of detection (0.1 μg g−1), precision (RSD < 1.6%), and accuracy (recovery = 95.5–104.3% range), when compared to other studies in the literature. The proposed automatic method presented suitable robustness, a high sampling rate (79 h−1), and lower waste generation per determination (0.900 mL), contributing to the basic principles of green chemistry.


Journal of the Brazilian Chemical Society | 2014

A micro-flow-batch analyzer using webcam for spectrophotometric determination of Ortho-phosphate and aluminium(III) in tap water

Marcelo B. Lima; Stéfani Iury E. Andrade; Maria S.S. Neta; Inakã S. Barreto; Luciano F. Almeida; Mário César Ugulino de Araújo

In this work, a micro-flow-batch analyzer (µFBA) using webcam for spectrophotometric determination of ortho-phosphate and aluminium(III) in tap water is proposed. PO43- and Al3+ determinations were performed by employing molybdenum blue and quecertin methods, respectively. In order to build linear analytical curves, a mathematical model was used on the basis of the RGB (red, green and blue) values. Working ranges were from 25 to 500 µg L-1 for both analytes with estimated limits of detection, relative standard deviation (RSD, n = 5) and sampling rate of 0.82 µg L-1, < 0.8% and 160 h-1 for PO43-, and 0.93 µg L-1, < 1.1% and 160 h-1 for Al(III). Comparing with the reference methods, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. Recovery study shows results between 98.1 and 102.8%. The proposed µFBA presented satisfactory portability, robustness, flexibility, low-cost device and reduced chemicals consumption.


Talanta | 2018

A robotic magnetic nanoparticle solid phase extraction system coupled to flow-batch analyzer and GFAAS for determination of trace cadmium in edible oils without external pretreatment

Inakã S. Barreto; Stéfani Iury E. Andrade; Francisco Antônio da Silva Cunha; Marcelo B. Lima; Mário César Ugulino de Araújo; Luciano F. Almeida

A lab-made magnetic-mechanical robotic (MMR) system coupled to a flow-batch analyzer (FBA) for magnetic nanoparticles solid phase extraction (MSPE) is presented. As an illustrative application, an NMR-FBA couple was connected to a graphite furnace atomic absorption spectrometer (GFAAS) for quantification of trace cadmium in edible oils. Factors affecting MSPE, such as the amount of adsorbent, the type, concentration and volume of the eluent and elution time were studied. Under the optimized experimental conditions, the interferents studied did not reveal a significant change in the analytical response, indicating that proposed method is selective. The sampling rate, characteristic mass, working linear range, limits of detection (LOD), and sensitivity were 10h-1, 0.18pg, 0.05-1.0μgkg-1, 0.006μgL-1, and 0.4197, respectively. An enrichment factor of 9 was achieved using a 2.5mL oil sample. In order to evaluate the accuracy, a certified reference material was analyzed by the proposed and a reference method. The values obtained were compared with the one provided from the manufacturer and no statistically significant differences were observed among three values at a confidence level of 95% using paired t-test. In addition, the precision intra-day and inter day of the proposed method and the robustness were assessed and again no statistically significant differences were observed at a confidence level of 95%. The use of a microcolumn to immobilize the MNPs is not needed with the proposed MMR-FBA-GFAAS system, thus avoiding the well-known problem of non-uniform packing of the MNPs presented in previous flow-based automatic methods. Despite a high organic load of edible oils, the method developed is simple, robust and presents satisfactory analytical features when compared with others that have been reported in the literature, suggesting that it is a potentially useful alternative to determine trace analytes in viscous matrices without external pretreatment.

Collaboration


Dive into the Stéfani Iury E. Andrade's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Marcelo B. Lima

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Inakã S. Barreto

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Luciano F. Almeida

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Edvan Cirino da Silva

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

David P. Harding

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Maria S.S. Neta

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Renato A.N. Andrade

Federal University of Paraíba

View shared research outputs
Top Co-Authors

Avatar

Adamastor R. Tôrres

Federal University of Paraíba

View shared research outputs
Researchain Logo
Decentralizing Knowledge