Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Stefanie Weinstein is active.

Publication


Featured researches published by Stefanie Weinstein.


Journal of Cancer | 2013

Advances in CT colonography for colorectal cancer screening and diagnosis

Judy Yee; Stefanie Weinstein; Tara A. Morgan; Patrick Alore; Rizwan Aslam

CT colonography (CTC) is a validated colorectal cancer test that provides an additional minimally-invasive screening option which is likely to be preferred by some patients. Important examination prerequisites include adequate colonic cleansing and distention. Tagging of residual material aids in the differentiation of true polyps from stool. Low radiation dose technique should be employed routinely for screening studies. Readers must be skilled in the use of both 2D and 3D interpretation methods.


Radiology | 2011

Reduced Cathartic Bowel Preparation for CT Colonography: Prospective Comparison of 2-L Polyethylene Glycol and Magnesium Citrate

Alexander W. Keedy; Judy Yee; Rizwan Aslam; Stefanie Weinstein; Luis A. Landeras; Janak N. Shah; Kenneth R. McQuaid; Benjamin M. Yeh

PURPOSE To prospectively compare adequacy of colonic cleansing, adequacy of solid stool and fluid tagging, and patient acceptance by using reduced-volume, 2-L polyethylene glycol (PEG) versus magnesium citrate bowel preparations for CT colonography. MATERIALS AND METHODS This study was approved by the institutional Committee on Human Research and was compliant with HIPAA; all patients provided written consent. In this randomized, investigator-blinded study, 50 patients underwent oral preparation with either a 2-L PEG or a magnesium citrate solution, tagging with oral contrast agents, and subsequent CT colonography and segmentally unblinded colonoscopy. The residual stool (score 0 [best] to 3 [worst]) and fluid (score 0 [best] to 4 [worst]) burden and tagging adequacy were qualitatively assessed. Residual fluid attenuation was recorded as a quantitative measure of tagging adequacy. Patients completed a tolerance questionnaire within 2 weeks of scanning. Preparations were compared for residual stool and fluid by using generalized estimating equations; the Mann-Whitney test was used to compare the qualitative tagging score, mean residual fluid attenuation, and adverse effects assessed on the patient experience questionnaire. RESULTS The mean residual stool (0.90 of three) and fluid burden (1.05 of four) scores for PEG were similar to those for magnesium citrate (0.96 [P = .58] and 0.98 [P = .48], respectively). However, the mean fecal and fluid tagging scores were significantly better for PEG (0.48 and 0.28, respectively) than for magnesium citrate (1.52 [P < .01] and 1.28 [P < .01], respectively). Mean residual fluid attenuation was higher for PEG (765 HU) than for magnesium citrate (443 HU, P = .01), and mean interpretation time was shorter for PEG (14.8 minutes) than for magnesium citrate (18.0 minutes, P = .04). Tolerance ratings were not significantly different between preparations. CONCLUSION Reduced-volume PEG and magnesium citrate bowel preparations demonstrated adequate cleansing effectiveness for CT colonography, with better tagging and shorter interpretation time observed in the PEG group. Adequate polyp detection was maintained but requires further validation because of the small number of clinically important polyps.


Radiographics | 2013

Multidetector CT of the Postoperative Colon: Review of Normal Appearances and Common Complications

Stefanie Weinstein; Samuel Osei-Bonsu; Rizwan Aslam; Judy Yee

If not properly recognized, the normal postoperative appearance of the pelvis following colorectal surgery can be misinterpreted as disease, including infection or recurrent tumor. However, multidetector computed tomography (CT) with the supplemental use of multiplanar reformation clearly demonstrates the expected postoperative anatomic changes in this setting. The high-resolution images achievable with multidetector CT enable the radiologist to play an important role in the postoperative assessment of patients following colon surgery. Whenever possible, the radiologist should be aware of the specific indication for the study, the type of surgery that was performed (ranging from segmental bowel excision to more extensive radical resection), and what anastomoses were created. This knowledge, as well as familiarity with the normal multidetector CT appearances of various postoperative complications, is critical for prompt diagnosis and appropriate management of these complications and for better differentiation of complications from normal findings.


American Journal of Roentgenology | 2011

Colorectal cancer screening in women: An underutilized lifesaver

Lisa L. Chu; Stefanie Weinstein; Judy Yee

OBJECTIVE Colorectal cancer (CRC) represents the third most common cancer diagnosed and a major cause of cancer-related deaths in women. Despite strong evidence that early screening decreases colorectal cancer incidence and mortality rates, colorectal cancer screening rates in women still lag significantly behind screening rates for breast and cervical cancers. Additionally, women have been found to be less likely than men to undergo CRC screening. This is despite the fact that the overall lifetime risk for the development of colorectal carcinoma is similar in both sexes. Barriers to screening have been found to be different for women compared with men. Screening adherence in women also appears to be associated with various social and demographic factors. CONCLUSION CT colonography (CTC) is an accurate, minimally invasive, and well-tolerated examination that is newly endorsed by the American Cancer Society, U.S. Multisociety Task Force, and the American College of Radiology. Improved screening compliance may occur in women with further dissemination of CTC.


Journal of Computer Assisted Tomography | 2012

Computed tomography and magnetic resonance imaging of adult renal cell carcinoma associated with Xp11.2 translocation.

Trien T. Dang; Etay Ziv; Stefanie Weinstein; Maxwell V. Meng; Zhen Wang; Fergus V. Coakley

Objective This study aimed to report the computed tomography (CT) and magnetic resonance imaging (MRI) findings of renal cell carcinoma associated with Xp11.2 translocation in adults. Methods We retrospectively identified 9 adults with renal cell carcinoma associated with Xp11.2 translocation who underwent baseline cross-sectional imaging with CT (n = 9) or MRI (n = 3). All available clinical, imaging, and histopathological records were reviewed. Results Mean patient age was 24 years (range, 18–45 years). Eight of 9 cancers demonstrated imaging findings of hemorrhage or necrosis (n = 3), advanced stage disease (n = 2), or both (n = 3) at CT or MRI. Conclusions The possibility of renal cell carcinoma associated with Xp11.2 translocation should be considered for a renal mass seen in a patient 45 years or younger, which demonstrates hemorrhage or necrosis or advanced stage disease at CT or MRI.


Journal of Ultrasound in Medicine | 2015

Value of Intraoperative Sonography in Pancreatic Surgery.

Stefanie Weinstein; Tara A. Morgan; Liina Poder; Lewis K. Shin; R. Brooke Jeffrey; Rizwan Aslam; Judy Yee

The utility of intraoperative sonography for pancreatic disease has been well described for detection and evaluation of neoplastic and inflammatory pancreatic disease. 1– 8 Intraoperative sonography can help substantially reduce surgical time as well as decrease potential injury to tissues and major structures. Imaging with sonography literally at the point of care—the surgeons scalpel—can precisely define the location of pancreatic lesions and their direct relationship with surrounding structures in real time during surgery. This article highlights our experience with intraoperative sonography at multiple institutional sites for both open and laparoscopic surgical procedures. We use intraoperative sonography for a wide range of pancreatic disease to provide accurate localization and staging of disease, provide guidance for enucleation of nonpalpable, nonvisible tumors, and in planning the most direct and least invasive surgical approach, avoiding injury to the pancreatic duct or other vital structures.


The Journal of Urology | 2017

Contrast Enhanced Ultrasound as a Radiation-Free Alternative to Fluoroscopic Nephrostogram for Evaluating Ureteral Patency

Thomas Chi; Manint Usawachintachit; Stefanie Weinstein; Maureen P. Kohi; Andrew G. Taylor; David T. Tzou; Helena C. Chang; Marshall L. Stoller; John Mongan

Purpose: We compared contrast enhanced ultrasound and fluoroscopic nephrostography in the evaluation of ureteral patency following percutaneous nephrolithotomy. Materials and Methods: This prospective cohort, noninferiority study was performed after obtaining institutional review board approval. We enrolled eligible patients with kidney and proximal ureteral stones who underwent percutaneous nephrolithotomy at our center. On postoperative day 1 patients received contrast enhanced ultrasound and fluoroscopic nephrostogram within 2 hours of each other to evaluate ureteral patency, which was the primary outcome of this study. Results: A total of 92 pairs of imaging studies were performed in 82 patients during the study period. Five study pairs were excluded due to technical errors that prevented imaging interpretation. Females slightly predominated over males with a mean ± SD age of 50.5 ± 15.9 years and a mean body mass index of 29.6 ± 8.6 kg/m2. Of the remaining 87 sets of studies 69 (79.3%) demonstrated concordant findings regarding ureteral patency for the 2 imaging techniques and 18 (20.7%) were discordant. The nephrostomy tube was removed on the same day in 15 of the 17 patients who demonstrated antegrade urine flow only on contrast enhanced ultrasound and they had no subsequent adverse events. No adverse events were noted related to ultrasound contrast injection. While contrast enhanced ultrasound used no ionizing radiation, fluoroscopic nephrostograms provided a mean radiation exposure dose of 2.8 ± 3.7 mGy. Conclusions: A contrast enhanced ultrasound nephrostogram can be safely performed to evaluate for ureteral patency following percutaneous nephrolithotomy. This imaging technique was mostly concordant with fluoroscopic findings. Most discordance was likely attributable to the higher sensitivity for patency of contrast enhanced ultrasound compared to fluoroscopy.


Radiology | 2017

Feasibility of Antegrade Contrast-enhanced US Nephrostograms to Evaluate Ureteral Patency

Thomas Chi; Manint Usawachintachit; John Mongan; Maureen P. Kohi; Andrew G. Taylor; Priyanka Jha; Helena C. Chang; Marshall L. Stoller; Ruth B. Goldstein; Stefanie Weinstein

Purpose To demonstrate the feasibility of contrast material-enhanced ulrasonographic (US) nephrostograms to assess ureteral patency after percutaneous nephrolithotomy (PCNL) in this proof-of-concept study. Materials and Methods For this HIPAA-compliant, institutional review board-approved prospective blinded pilot study, patients undergoing PCNL provided consent to undergo contrast-enhanced US and fluoroscopic nephrostograms on postoperative day 1. For contrast-enhanced US, 1.5 mL of Optison (GE Healthcare, Oslo, Norway) microbubble contrast agent solution (perflutren protein-type A microspheres) was injected via the nephrostomy tube. Unobstructed antegrade ureteral flow was defined by the presence of contrast material in the bladder. Contrast-enhanced US results were compared against those of fluoroscopic nephrostograms for concordance. Results Ten studies were performed in nine patients (four women, five men). Contrast-enhanced US demonstrated ureteral patency in eight studies and obstruction in two. One patient underwent two studies, one showing obstruction and the second showing patency. Concordance between US and fluoroscopic assessments of ureteral patency was evaluated by using a Clopper-Pearson exact binomial test. These results were perfectly concordant with fluoroscopic nephrostogram results, with a 95% confidence interval of 69.2% and 100%. No complications or adverse events related to contrast-enhanced US occurred. Conclusion Contrast-enhanced US nephrostograms are simple to perform and are capable of demonstrating both patency and obstruction of the ureter. The perfect concordance with fluoroscopic results across 10 studies demonstrated here is not sufficient to establish diagnostic accuracy of this technique, but motivates further, larger scale investigation. If subsequent larger studies confirm these preliminary results, contrast-enhanced US may provide a safer, more convenient way to evaluate ureteral patency than fluoroscopy.


Magnetic Resonance Imaging | 2016

Comparison of diffusion-weighted imaging and T2-weighted single shot fast spin-echo: Implications for LI-RADS characterization of hepatocellular carcinoma.

Robert M. Hicks; Judy Yee; Michael A. Ohliger; Stefanie Weinstein; Jeffrey S. Kao; Nabia S. Ikram; Thomas A. Hope

PURPOSE To evaluate the performance of diffusion-weighted imaging (DWI) and T2-weighted single shot fast spin-echo (SSFSE) imaging of the liver in the detection of hepatocellular carcinoma (HCC) in reference to the LI-RADS classification system. METHODS MR images of 40 patients with 68 LI-RADS grade 3-5 lesions were analyzed. Two readers independently reviewed sequences and characterized lesion signal intensity, followed by consensus evaluation. CE-MRI served as reference standard. Sensitivities were compared across sequences. Lesion-to-liver contrast-to-noise ratios (CNRs) and apparent diffusion coefficients (ADCs) were measured and compared using the Wilcoxon signed-rank test across sequences and the Mann-Whitney U or Kruskal-Wallis test between LI-RADS categories. Inter-reader variability was assessed using Cohens kappa statistic. RESULTS Consensus sensitivities of LI-RADS 3-5 lesions using SSFSE images versus DWI were similar (0.53-0.63, p=0.089), however, the sensitivity with DWI b=700 was higher (0.63) than DWI b=0 (0.53, p=0.039). Lesion-to-liver CNRs were larger for all DWI sequences compared to SSFSE images (p<0.001 for all). ADCs of large (>2cm) LIRADS 3-5 lesions were lower than those of small lesions (1.09±0.33 vs. 1.31±0.26, p=0.02), however lesion ADCs were not different from those of adjacent hepatic parenchyma for any LI-RADS lesion. CONCLUSIONS DWI has a similar sensitivity compared to SSFSE, but intensity on DWI likely represents intrinsic T2 signal hyper-intensity rather than restricted diffusion as the ADC values were not lower than adjacent parenchyma. Therefore it may not be appropriate to consider hyper-intensity on high b-value as a separate ancillary criteria to T2 hyper-intensity in LI-RADS.


Journal of Ultrasound in Medicine | 2015

Intraoperative sonography during carotid endarterectomy: Normal appearance and spectrum of complications

Stefanie Weinstein; Marc C. Mabray; Riz Aslam; Tom Hope; Judy Yee; Christopher D. Owens

Carotid endarterectomy is a commonly performed procedure for prevention of stroke related to carotid stenosis. Intraoperative sonography is used to identify potentially correctable technical defects during carotid endarterectomy. The main risk of endarterectomy is perioperative stroke, and great effort has been put into trying to reduce this risk through various surgical techniques and evaluation of the surgical bed. Postoperative carotid thrombosis, or thombo‐embolization from the arterectomy site, remains a common cause of perioperative stroke and is often related to technical defects in the arterial reconstruction procedure. Re‐exploration and repair of any imperfections have the potential to improve outcomes. Intraoperative imaging can identify potentially occult lesions, provide the option for correction, and thus reduce chance of stroke. Familiarity with the spectrum of intraoperative sonographic findings helps correctly identify residual intimal dissection flaps, plaque, thrombi, and stenosis, which may require immediate surgical revision. Our objective is to illustrate the spectrum of intraoperative findings and their importance.

Collaboration


Dive into the Stefanie Weinstein's collaboration.

Top Co-Authors

Avatar

Judy Yee

University of California

View shared research outputs
Top Co-Authors

Avatar

Rizwan Aslam

University of California

View shared research outputs
Top Co-Authors

Avatar

John Mongan

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Thomas A. Hope

University of California

View shared research outputs
Top Co-Authors

Avatar

Thomas Chi

University of California

View shared research outputs
Top Co-Authors

Avatar

Tara A. Morgan

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge