Stephanie A. Solazzo
Beth Israel Deaconess Medical Center
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Stephanie A. Solazzo.
Radiology | 2009
Rachel Schor-Bardach; David C. Alsop; Ivan Pedrosa; Stephanie A. Solazzo; Xiaoen Wang; Robert P. Marquis; Michael B. Atkins; Meredith M. Regan; Sabina Signoretti; Robert E. Lenkinski; S. Nahum Goldberg
PURPOSE To determine whether arterial spin-labeling (ASL) magnetic resonance (MR) imaging findings at baseline and early during antiangiogenic therapy can predict later resistance to therapy. MATERIALS AND METHODS Protocol was approved by an institutional animal care and use committee. Caki-1, A498, and 786-0 human renal cell carcinoma (RCC) xenografts were implanted in 39 nude mice. Animals received 80 mg sorafenib per kilogram of body weight once daily once tumors measured 12 mm. ASL imaging was performed at baseline and day 14, with additional imaging performed for 786-0 and A498 (3 days to 12 weeks). Mean blood flow values and qualitative differences in spatial distribution of blood flow were analyzed and compared with histopathologic findings for viability and microvascular density. t Tests were used to compare differences in mean tumor blood flow. Bonferroni-adjusted P values less than .05 denoted significant differences. RESULTS Baseline blood flow was 80.1 mL/100 g/min +/- 23.3 (standard deviation) for A498, 75.1 mL/100 g/min +/- 28.6 for 786-0, and 10.2 mL/100 g/min +/- 9.0 for Caki-1. Treated Caki-1 showed no significant change (14.9 mL/100 g/min +/- 7.6) in flow, whereas flow decreased in all treated A498 on day 14 (47.9 mL/100 g/min +/- 21.1) and in 786-0 on day 3 (20.3 mL/100 g/min +/- 8.7) (P = .003 and .03, respectively). For A498, lowest values were measured at 28-42 days of receiving sorafenib. Regions of increased flow occurred on days 35-49, 17-32 days before documented tumor growth and before significant increases in mean flow (day 77). Although 786-0 showed new, progressive regions with signal intensity detected as early as day 5 that correlated to viable tumor at histopathologic examination, no significant changes in mean flow were noted when day 3 was compared with all subsequent days (P > .99). CONCLUSION ASL imaging provides clinically relevant information regarding tumor viability in RCC lines that respond to sorafenib.
Radiology | 2010
Stephanie A. Solazzo; Muneeb Ahmed; Rachel Schor-Bardach; Wei Yang; Geoffrey D. Girnun; Syed Rahmanuddin; Tatyana Levchenko; Sabina Signoretti; Douglas R. Spitz; Vladimir P. Torchilin; S. Nahum Goldberg
PURPOSE To determine if oxidative and nitrative stress and/or apoptosis contribute to increased coagulation when combining radiofrequency (RF) ablation with liposomal doxorubicin. MATERIALS AND METHODS Animal care committee approval was obtained. R3230 mammary adenocarcinomas in Fischer rats were treated with either RF ablation (n = 43), 1 mg of intravenously injected liposomal doxorubicin (n = 26), or combined therapy (n = 30) and were compared with control subjects (n = 11). A subset of animals receiving combination therapy (n = 24) were treated in the presence or absence of N-acetylcysteine (NAC) administered 24 hours and 1 hour before RF ablation. Tumors were analyzed 2 minutes to 72 hours after treatment to determine the temporal range of response by using immunohistochemical staining of the apoptosis marker cleaved caspase-3, phosphorylated gammaH2AX, and HSP70 and of markers of oxidative and nitrative stress (8-hydroxydeoxyguanosine [8-OHdG], 4-hydroxynonenal [4-HNE]-modified proteins, and nitrotyrosine [NT]). Statistical analyses, including t tests and analysis of variance for comparisons where appropriate, were performed. RESULTS By 4 hours after RF ablation alone, a 0.48-mm +/- 0.13 (standard deviation) peripheral band with 57.0% +/- 7.3 cleaved caspase-3 positive cells was noted at the ablation margin, whereas a 0.73-mm +/- 0.18 band with 77.7% +/- 6.3 positivity was seen for combination therapy (P < .03 for both comparisons). Combination therapy caused increased and earlier staining for 4-HNE-modified proteins, 8-OHdG, NT, and gammaH2AX with colocalization to cleaved caspase-3 staining. A rim of increased HSP70 was identified peripheral to the area of cleaved caspase-3. Parameters of oxidative and nitrative stress were significantly inhibited by NAC 1 hour following RF ablation, resulting in decreased cleaved caspase-3 positivity (0.28-mm +/- 0.09 band of 25.9% +/- 7.4 positivity vs 0.59-mm +/- 0.11 band of 62.9% +/- 6.0 positivity, P < .001 for both comparisons). CONCLUSION Combining RF ablation with liposomal doxorubicin increases cell injury and apoptosis in the zone of increased coagulation by using a mechanism that involves oxidative and nitrative stress that leads to accelerated apoptosis.
Journal of Vascular and Interventional Radiology | 2004
Clare Horkan; Muneeb Ahmed; Zhengjun Liu; G. Scott Gazelle; Stephanie A. Solazzo; Jonathan B. Kruskal; S. Nahum Goldberg
PURPOSE To determine whether pharmacologic agents can be used to modulate blood flow in hepatic and renal tumors sufficiently to alter the extent of radiofrequency (RF)-induced coagulation. MATERIALS AND METHODS VX2 tumors (8-15 mm) were implanted in the liver (n = 25) or kidney (n = 8) of 33 New Zealand White rabbits. RF was applied to tumors for 6 minutes with use of conventional electrodes (125 mA +/- 35; 90 degrees C +/- 2 degrees C tip temperature). In the hepatic model, blood flow was modulated with use of halothane, epinephrine, or arsenic trioxide (2-6 mg/kg). Laser Doppler flowmetry was used to quantify changes in hepatic blood flow. Correlation of blood flow with induced coagulation diameter was performed. RF ablation was then performed in a renal model with and without arsenic trioxide. RESULTS For liver tumors, halothane and arsenic trioxide reduced blood flow to 40.3% +/- 17.8% and 29% +/- 15% of normal, respectively, whereas epinephrine increased blood flow to 207.8% +/- 97.9%. Correlation of blood flow to coagulation diameter was demonstrated (R(2) = 0.40). Coagulation measured 7 mm +/- 1 with epinephrine, 10 mm +/- 1 with normal blood flow, 12 mm +/- 3 with halothane, and 13 mm +/- 3 with arsenic trioxide (P <.04 compared with controls). In the renal model, arsenic trioxide decreased blood flow (44% +/- 16%) and increased coagulation diameter (10.9 mm +/- 1) compared with controls (84% +/- 11% and 7.6 mm +/- 1; P <.01, both comparisons). CONCLUSIONS RF-induced coagulation necrosis in rabbit hepatic and renal tumors is affected by tumor blood flow. Pharmacologic modulation of tumor blood flow may provide a noninvasive way to decrease blood flow during thermally mediated ablation therapy, potentially enabling the creation of larger zones of coagulation necrosis.
Journal of Vascular and Interventional Radiology | 2004
Andrew Hines-Peralta; C. Yehuda Hollander; Stephanie A. Solazzo; Clare Horkan; Zhengjun Liu; S. Nahum Goldberg
PURPOSE To determine whether the simultaneous application of combined bipolar radiofrequency (RF) ablation and cryoablation in a hybrid system produces larger ablation zones than RF or cryoablation alone. MATERIALS AND METHODS Multiple 15-minute ablations were performed in ex vivo bovine liver (n = 167) with a hybrid applicator system with RF ablation alone (0.3-0.7 A), cryoablation alone (3,500 psi, two freeze/thaw cycles), and combined RF/cryoablation (0.4-0.7 A, 1,000-3,500 psi) with use of a novel applicator consisting of two 2.5-cm active bipolar RF poles located on the same 18-gauge needle separated by two embedded cryoablation nozzles. Resultant coagulation diameters were compared with use of analysis of variance for more than three groups or Student t tests for two groups. Confirmation of the optimal parameters of combination RF/cryoablation was performed by reassessing a range of argon pressure (1,000-3,500 psi) and RF current (0.4-0.7 A) in in vivo porcine liver (n = 36). Arrays of two to four RF/cryoablation applicators were also assessed in ex vivo (n = 54) and in vivo (n = 12) liver. RESULTS In ex vivo liver, simultaneous RF/cryoablation (0.6 A, 3,000 psi) produced 3.6 cm +/- 0.4 of short-axis coagulation. This was significantly larger than that achieved with optimal RF alone or cryoablation alone (1.5 cm +/- 0.3 and 1.6 cm +/- 0.3, respectively; F = 95; P < .01). The coagulation diameter with simultaneous combination RF/cryoablation was related in parabolic fashion to argon pressure and current with a multivariate r(2) of 0.68. For in vivo liver, optimal combination RF/cryoablation achieved 3.3 cm +/- 0.2 of coagulation, which was significantly larger than that achieved with RF alone (1.1 cm +/- 0.1; P < .01) or cryoablation alone (1.1 cm +/- 0.1 and 1.3 cm +/- 0.1; F = 203; P < .01). The greatest contiguous coagulation was achieved with multiple-applicator arrays. For ex vivo liver, short-axis coagulation measured 5.3 cm +/- 0.1, 6.4 cm +/- 0.1, and 7.6 cm +/- 0.1 for two-, three-, and four-applicator arrays, respectively. For in vivo liver, two-, three-, and four-applicator arrays produced 5.1 cm +/- 0.2, 5.8 cm +/- 0.5, and 7.0 cm +/- 0.5 of confluent coagulation, respectively. CONCLUSION Simultaneous combination RF and cryoablation with use of a novel applicator design yielded significantly larger zones of coagulation than either modality alone. The large ablation diameters achieved warrant further investigation of the device.
International Journal of Hyperthermia | 2008
Stephanie A. Solazzo; Pawel Mertyna; Himija Peddi; Muneeb Ahmed; Clare Horkan; S. Nahum Goldberg
Purpose: To determine the critical thermal dosimetry and relative efficacy for RF ablation combined with external beam radiation (XRT) or liposomal doxorubicin (LD), in an animal tumor model. Materials and methods: This study was performed in two phases, in 13–18 mm diameter R3230 tumors subcutaneously implanted into Fischer rats. In phase 1, tumors (n = 30) were randomized into six groups. RF energy (titrated to 70°C tip temperature) was applied for either 2.5 or 5 min (n = 15, each group). For each duration, one of three adjuvant therapies was applied (n = 5, each): no therapy (control), LD (1 mg intravenously, 30 min post-RF), or XRT (20 Gy at 1 Gy min−1, within 2 h post-RF), with sacrifice at 48 h for pathologic analysis. In phase 2, thermal mapping was performed in 20 tumors throughout RF application (70°C; 5 min), at 1.5–7 mm distances from the active electrode tip. Temperature profiles throughout the tumor were constructed and were used to interpolate temperatures over time at the critical ablation margin, to derive maximum threshold temperature, AUC (area under the curve) and CEM43 (cumulative equivalent minutes at 43°C). Ablation sizes and all calculated values were compared within and across experimental groups using MANOVA statistics with pair-wise T-test for individual comparisons. Results: RF/XRT produced the largest coagulation (11.7 ± 1.5 mm at 2.5 min, ≥15 ± 0.7 mm at 5 min), followed by RF/LD, and then RF alone (p < 0.001 for all comparisons). RF/XRT demonstrated temperature threshold decreases from RF alone of 11.7 ± 0.01°C and 12.7 ± 0.38°C at 2.5 and 5 min respectively (with absolute thresholds of 42°C for XRT compared to 52°C for RF alone). RF/LD had decreases of 4.0°C at 2.5 min and 4.4°C at 5 min. Thermal dose requirements (AUC) decreased by 7.79% or 9.28% for RF/LD compared to ≥19.36% or 25.82% for RF/XRT at 2.5 and 5 min (p < 0.001). CEM43 values followed similar patterns (p < 0.001), but with a reduction of 101 and 104 in magnitude for RF/LD and RF/XRT therapies at 5 min, respectively. Conclusions: For a standardized RF dose, the combination of high dose XRT and RF increased ablation size compared to RF and liposomal doxorubicin or RF alone. Increased ablation size is more closely associated with decreased temperature threshold necessary to induce coagulation, rather than the total thermal dose.
Journal of Vascular and Interventional Radiology | 2006
Andrew Hines-Peralta; Zhengjun Liu; Clare Horkan; Stephanie A. Solazzo; S. Nahum Goldberg
PURPOSE To determine whether larger confluent zones of ablation can be achieved in chemical ablation with use of a multiple-tine infusion device compared with standard needle infusion in a solid tumor model. MATERIALS AND METHODS Multiple canine venereal sarcomas (N=42) were implanted in nine mildly immunosuppressed dogs (treated with 10 mg/kg cyclosporin A twice daily). Tumors incubated for 8-12 weeks grew to a diameter of 5.4 cm+/-1.0. With ultrasound guidance, 8-56 mL of 100% ethanol or 15% acetic acid (diluted in saturated saline solution) were injected in aliquots (2-8 mL) at multiple distances (radius of 0-2 cm) from the needle axis with use of a multiple-tine infusion device. Presence of fluid reflux at the needle puncture site and resultant coagulation diameters were measured within 1 hour and compared with the results of infusion with a standard 18-gauge needle. RESULTS Multiple-tine infusion enabled greater fluid infusion (15 mL+/-3 to 53 mL+/-3 depending on protocol) than standard needle injection (8 mL+/-1) before reflux was observed at the puncture site (P<.01). Additionally, progressive gains in contiguous tumor coagulation were achieved because acetic acid was infused as far as 2 cm from the needle axis with the multiple-tine device (P<.01; R(2)=0.59; y=0.5x+2.9). Optimal coagulation was achieved with the infusion of 4-mL aliquots at 0.5 cm and 1.0 cm from the needle, followed by three 4-mL or 8-mL aliquots (40 degrees rotation between infusions) at 1.5 cm and 2.0 cm from the needle (32 mL+/-0 and 53 mL+/-3 total, respectively). This yielded confluent short-axis coagulation diameters of 4.9 cm+/-1.0 and 5.4 cm+/-1.0, respectively, which were significantly greater than the measurement of 3.1 cm+/-0.4 achieved with standard needle infusion (P<.01). Smaller and noncontiguous foci of coagulation foci (1.7 cm+- 0.5) were seen with the use of ethanol for standard needle and multiple-tine infusions. CONCLUSIONS Chemical ablation with 15% acetic acid with use of a multiple-tine infusion device resulted in larger diameters of contiguous tumor coagulation and enabled greater volumes of infusion than standard needle infusion or ethanol ablation. This suggests that chemical ablation with acetic acid infused with use of a multiple-tine device may overcome some of the difficulties seen with the use of conventional needle chemical ablation injection alone, such as irregular ablation and fluid reflux up the needle tract.
Journal of Magnetic Resonance Imaging | 2008
Martina Morrin; Ivan Pedrosa; Charles A. McKenzie; Richard J. Farrell; Nicolas Bloch; Stephanie A. Solazzo; Long Ngo; Shraga Nahum Goldberg; Neil M. Rofsky
To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)‐enhanced T2W SSFSE (single shot fast spin echo) and T1‐weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath‐hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET‐enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.
Radiology | 2005
Stephanie A. Solazzo; Zhengjun Liu; S. Melvyn Lobo; Muneeb Ahmed; Andrew Hines-Peralta; Robert E. Lenkinski; S. Nahum Goldberg
American Journal of Roentgenology | 2005
Zhengjun Liu; S. Melvyn Lobo; Stanley Humphries; Clare Horkan; Stephanie A. Solazzo; Andrew Hines-Peralta; Robert E. Lenkinski; S. Nahum Goldberg
Radiology | 2007
Stephanie A. Solazzo; Muneeb Ahmed; Zhengjun Liu; Andrew Hines-Peralta; S. Nahum Goldberg