Stephen Barnard
Public Health England
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Stephen Barnard.
PLOS ONE | 2011
Simon Horn; Stephen Barnard; Kai Rothkamm
Most human exposures to ionising radiation are partial body exposures. However, to date only limited tools are available for rapid and accurate estimation of the dose distribution and the extent of the body spared from the exposure. These parameters are of great importance for emergency triage and clinical management of exposed individuals. Here, measurements of γ-H2AX immunofluorescence by microscopy and flow cytometry were compared as rapid biodosimetric tools for whole and partial body exposures. Ex vivo uniformly X-irradiated blood lymphocytes from one donor were used to generate a universal biexponential calibration function for γ-H2AX foci/intensity yields per unit dose for time points up to 96 hours post exposure. Foci – but not intensity – levels remained significantly above background for 96 hours for doses of 0.5 Gy or more. Foci-based dose estimates for ex vivo X-irradiated blood samples from 13 volunteers were in excellent agreement with the actual dose delivered to the targeted samples. Flow cytometric dose estimates for X-irradiated blood samples from 8 volunteers were in excellent agreement with the actual dose delivered at 1 hour post exposure but less so at 24 hours post exposure. In partial body exposures, simulated by mixing ex vivo irradiated and unirradiated lymphocytes, foci/intensity distributions were significantly over-dispersed compared to uniformly irradiated lymphocytes. For both methods and in all cases the estimated fraction of irradiated lymphocytes and dose to that fraction, calculated using the zero contaminated Poisson test and γ-H2AX calibration function, were in good agreement with the actual mixing ratios and doses delivered to the samples. In conclusion, γ-H2AX analysis of irradiated lymphocytes enables rapid and accurate assessment of whole body doses while dispersion analysis of foci or intensity distributions helps determine partial body doses and the irradiated fraction size in cases of partial body exposures.
Environmental and Molecular Mutagenesis | 2015
Kai Rothkamm; Stephen Barnard; Jayne Moquet; Michele Ellender; Zohaib Rana; Susanne Burdak-Rothkamm
The discovery of DNA damage response proteins such as γH2AX, ATM, 53BP1, RAD51, and the MRE11/RAD50/NBS1 complex, that accumulate and/or are modified in the vicinity of a chromosomal DNA double‐strand break to form microscopically visible, subnuclear foci, has revolutionized the detection of these lesions and has enabled studies of the cellular machinery that contributes to their repair. Double‐strand breaks are induced directly by a number of physical and chemical agents, including ionizing radiation and radiomimetic drugs, but can also arise as secondary lesions during replication and DNA repair following exposure to a wide range of genotoxins. Here we aim to review the biological meaning and significance of DNA damage foci, looking specifically at a range of different settings in which such markers of DNA damage and repair are being studied and interpreted. Environ. Mol. Mutagen. 56:491–504, 2015.
Radiation Research | 2013
Kai Rothkamm; Christina Beinke; Horst Romm; Christophe Badie; Y. Balagurunathan; Stephen Barnard; N. Bernard; H. Boulay-Greene; M. Brengues; A. De Amicis; S. De Sanctis; R. Greither; F. Herodin; A. Jones; Sylwia Kabacik; T. Knie; Ulrike Kulka; Florigio Lista; P. Martigne; A. Missel; Jayne Moquet; Ursula Oestreicher; A. Peinnequin; T. Poyot; U. Roessler; Harry Scherthan; B. Terbrueggen; Hubert Thierens; M. Valente; Anne Vral
Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.
Radiation Protection Dosimetry | 2015
Ulrike Kulka; L. Ainsbury; Michael J. Atkinson; Stephen Barnard; R. W. Smith; Joan Francesc Barquinero; Leonardo Barrios; C. Bassinet; Christina Beinke; Alexandra Cucu; F. Darroudi; P. Fattibene; E. Bortolin; S. Della Monaca; Octávia Monteiro Gil; Eric Gregoire; Valeria Hadjidekova; Siamak Haghdoost; Vasiliki I. Hatzi; W. Hempel; R. Herranz; Alicja Jaworska; Carita Lindholm; Katalin Lumniczky; R. Mkacher; S. Mörtl; Alegría Montoro; Jayne Moquet; Mercedes Moreno; Mihaela Noditi
Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.
Radiation Research | 2013
Christina Beinke; Stephen Barnard; H. Boulay-Greene; A. De Amicis; S. De Sanctis; F. Herodin; A. Jones; Ulrike Kulka; Florigio Lista; D. Lloyd; P. Martigne; Jayne Moquet; Ursula Oestreicher; Horst Romm; Kai Rothkamm; M. Valente; Viktor Meineke; Herbert Braselmann; Michael Abend
The study design and obtained results represent an intercomparison of various laboratories performing dose assessment using the dicentric chromosome analysis (DCA) as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25–5 Gy) as well as blind samples (0.1–6.4 Gy) were sent to the participants. DCA was performed according to established protocols. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 2.4 days after sample arrival. DCA dose estimates were reported with high and comparable accuracy, with MAD values ranging between 0.16–0.5 Gy for both manual and automated scoring. No significant differences were found for dose estimates based either on 20, 30, 40 or 50 cells, suggesting that the scored number of cells can be reduced from 50 to 20 without loss of precision of triage dose estimates, at least for homogenous exposure scenarios. Triage categories of clinical significance could be discriminated efficiently using both scoring procedures.
Genome Integrity | 2013
Stephen Barnard; Simon Bouffler; Kai Rothkamm
DNA double-strand breaks are among the most deleterious lesions induced by ionising radiation. A range of inter-connected cellular response mechanisms has evolved to enable their efficient repair and thus protect the cell from the harmful consequences of un- or mis-repaired breaks which may include early effects such as cell killing and associated acute toxicities and late effects such as cancer. A number of studies suggest that the induction and repair of double-strand breaks may not always occur linearly with ionising radiation dose. Here we have aimed to identify and discuss some of the biological and methodological factors that can potentially modify the shape of the dose response curve obtained for these endpoints using the most common assays for double-strand breaks, pulsed-field gel electrophoresis and microscopic scoring of radiation-induced foci.
Mutation Research-reviews in Mutation Research | 2016
Elizabeth A. Ainsbury; Stephen Barnard; Scott Bright; Claudia Dalke; Miguel Jarrin; Sarah Kunze; Rick Tanner; Joseph R. Dynlacht; Roy A. Quinlan; Jochen Graw; Munira Kadhim; Nobuyuki Hamada
The lens of the eye has long been considered as a radiosensitive tissue, but recent research has suggested that the radiosensitivity is even greater than previously thought. The 2012 recommendation of the International Commission on Radiological Protection (ICRP) to substantially reduce the annual occupational equivalent dose limit for the ocular lens has now been adopted in the European Union and is under consideration around the rest of the world. However, ICRP clearly states that the recommendations are chiefly based on epidemiological evidence because there are a very small number of studies that provide explicit biological, mechanistic evidence at doses <2Gy. This paper aims to present a review of recently published information on the biological and mechanistic aspects of cataracts induced by exposure to ionizing radiation (IR). The data were compiled by assessing the pertinent literature in several distinct areas which contribute to the understanding of IR induced cataracts, information regarding lens biology and general processes of cataractogenesis. Results from cellular and tissue level studies and animal models, and relevant human studies, were examined. The main focus was the biological effects of low linear energy transfer IR, but dosimetry issues and a number of other confounding factors were also considered. The results of this review clearly highlight a number of gaps in current knowledge. Overall, while there have been a number of recent advances in understanding, it remains unknown exactly how IR exposure contributes to opacification. A fuller understanding of how exposure to relatively low doses of IR promotes induction and/or progression of IR-induced cataracts will have important implications for prevention and treatment of this disease, as well as for the field of radiation protection.
International Journal of Radiation Biology | 2014
Elizabeth A. Ainsbury; Jenna Al-hafidh; Ainars Bajinskis; Stephen Barnard; Joan Francesc Barquinero; Christina Beinke; Virginie de Gelder; Eric Gregoire; Alicja Jaworska; Carita Lindholm; David G. Lloyd; Jayne Moquet; Reetta Nylund; Ursula Oestreicher; Sandrine Roch-Lefèvre; Kai Rothkamm; Horst Romm; Harry Scherthan; Sylwester Sommer; Hubert Thierens; Charlot Vandevoorde; Anne Vral; Andrzej Wojcik
Abstract Purpose: The European Unions Seventh Framework Programme-funded project ‘Multi-disciplinary biodosimetric tools to manage high scale radiological casualties’ (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose: Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals. Materials and methods: Three biological dosimetry tools – the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays – were tested, in addition to provision of the triage status results (low exposure: < 1 Gy; medium exposure: 1–2 Gy; high exposure: > 2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes: An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included. Results: The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here. Conclusions: The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective.
PeerJ | 2014
Jayne Moquet; Stephen Barnard; Kai Rothkamm
Following a radiation incident, preliminary dose estimates made by γ-H2AX foci analysis can supplement the early triage of casualties based on clinical symptoms. Sample processing time is important when many individuals need to be rapidly assessed. A protocol was therefore developed for high sample throughput that requires less than 0.1 ml blood, thus potentially enabling finger prick sampling. The technique combines red blood cell lysis and leukocyte fixation in one step on a 96 well plate, in contrast to the routine protocol, where lymphocytes in larger blood volumes are typically separated by Ficoll density gradient centrifugation with subsequent washing and fixation steps. The rapid ‘96 well lyse/fix’ method reduced the estimated sample processing time for 96 samples to about 4 h compared to 15 h using the routine protocol. However, scoring 20 cells in 96 samples prepared by the rapid protocol took longer than for the routine method (3.1 versus 1.5 h at zero dose; 7.0 versus 6.1 h for irradiated samples). Similar foci yields were scored for both protocols and consistent dose estimates were obtained for samples exposed to 0, 0.2, 0.6, 1.1, 1.2, 2.1 and 4.3 Gy of 250 kVp X-rays at 0.5 Gy/min and incubated for 2 h. Linear regression coefficients were 0.87 ± 0.06 (R2 = 97.6%) and 0.85 ± 0.05 (R2 = 98.3%) for estimated versus actual doses for the routine and lyse/fix method, respectively. The lyse/fix protocol can therefore facilitate high throughput processing for γ-H2AX biodosimetry for use in large scale radiation incidents, at the cost of somewhat longer foci scoring times.
Radiation Protection Dosimetry | 2014
Hubert Thierens; Anne Vral; Charlot Vandevoorde; Veerle Vandersickel; V. de Gelder; Horst Romm; Ursula Oestreicher; Kai Rothkamm; Stephen Barnard; Elizabeth A. Ainsbury; Sylwester Sommer; Christina Beinke; Andrzej Wojcik
Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.