Diabetes | 2012

Fully Integrated Artificial Pancreas in Type 1 Diabetes: Modular Closed-Loop Glucose Control Maintains Near Normoglycemia

Marc D. Breton; Anne Farret; Daniela Bruttomesso; Stacey M. Anderson; Lalo Magni; Stephen D. Patek; Chiara Dalla Man; Jerome Place; Susan Demartini; Simone Del Favero; Chiara Toffanin; Colleen Hughes-Karvetski; Eyal Dassau; Howard Zisser; Francis J. Doyle; Giuseppe De Nicolao; Angelo Avogaro; Claudio Cobelli; Eric Renard; Boris P. Kovatchev

Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9–10 mmol/L. The CLC system was fully integrated using automated data transfer CGM→algorithm→CSII. All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 mmol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs.


Journal of diabetes science and technology | 2010

Multinational Study of Subcutaneous Model-Predictive Closed-Loop Control in Type 1 Diabetes Mellitus: Summary of the Results

Boris P. Kovatchev; Claudio Cobelli; Eric Renard; Stacey M. Anderson; Marc D. Breton; Stephen D. Patek; William L. Clarke; Daniela Bruttomesso; Alberto Maran; Silvana Costa; Angelo Avogaro; Chiara Dalla Man; Andrea Facchinetti; Lalo Magni; Giuseppe De Nicolao; Jerome Place; Anne Farret

Background: In 2008–2009, the first multinational study was completed comparing closed-loop control (artificial pancreas) to state-of-the-art open-loop therapy in adults with type 1 diabetes mellitus (T1DM). Methods: The design of the control algorithm was done entirely in silico, i.e., using computer simulation experiments with N = 300 synthetic “subjects” with T1DM instead of traditional animal trials. The clinical experiments recruited 20 adults with T1DM at the Universities of Virginia (11); Padova, Italy (6); and Montpellier, France (3). Open-loop and closed-loop admission was scheduled 3–4 weeks apart, continued for 22 h (14.5 h of which were in closed loop), and used a continuous glucose monitor and an insulin pump. The only difference between the two sessions was that insulin dosing was performed by the patient under a physicians supervision during open loop, whereas insulin dosing was performed by a control algorithm during closed loop. Results: In silico design resulted in rapid (less than 6 months compared to years of animal trials) and cost-effective system development, testing, and regulatory approvals in the United States, Italy, and France. In the clinic, compared to open-loop, closed-loop control reduced nocturnal hypoglycemia (blood glucose below 3.9 mmol/liter) from 23 to 5 episodes (p < .01) and increased the amount of time spent overnight within the target range (3.9 to 7.8 mmol/liter) from 64% to 78% (p = .03). Conclusions: In silico experiments can be used as viable alternatives to animal trials for the preclinical testing of insulin treatment strategies. Compared to open-loop treatment under identical conditions, closed-loop control improves the overnight regulation of diabetes.


Journal of diabetes science and technology | 2009

Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience.

William L. Clarke; Stacey M. Anderson; Marc D. Breton; Stephen D. Patek; Laurissa Kashmer; Boris P. Kovatchev

Background: Recent progress in the development of clinically accurate continuous glucose monitors (CGMs), automated continuous insulin infusion pumps, and control algorithms for calculating insulin doses from CGM data have enabled the development of prototypes of subcutaneous closed-loop systems for controlling blood glucose (BG) levels in type 1 diabetes. The use of a new personalized model predictive control (MPC) algorithm to determine insulin doses to achieve and maintain BG levels between 70 and 140 mg/dl overnight and to control postprandial BG levels is presented. Methods: Eight adults with type 1 diabetes were studied twice, once using their personal open-loop systems to control BG overnight and for 4 h following a standardized meal and once using a closed-loop system that utilizes the MPC algorithm to control BG overnight and for 4 h following a standardized meal. Average BG levels, percentage of time within BG target of 70–140 mg/dl, number of hypoglycemia episodes, and postprandial BG excursions during both study periods were compared. Results: With closed-loop control, once BG levels achieved the target range (70–140 mg/dl), they remained within that range throughout the night in seven of the eight subjects. One subject developed a BG level of 65 mg/dl, which was signaled by the CGM trend analysis, and the MPC algorithm directed the discontinuance of the insulin infusion. The number of overnight hypoglycemic events was significantly reduced (p = .011) with closed-loop control. Postprandial BG excursions were similar during closed-loop and open-loop control Conclusion: Model predictive closed-loop control of BG levels can be achieved overnight and following a standardized breakfast meal. This “artificial pancreas” controls BG levels as effectively as patient-directed open-loop control following a morning meal but is significantly superior to open-loop control in preventing overnight hypoglycemia.


Journal of diabetes science and technology | 2008

Evaluating the Efficacy of Closed-Loop Glucose Regulation via Control-Variability Grid Analysis

Lalo Magni; Davide Martino Raimondo; Chiara Dalla Man; Marc D. Breton; Stephen D. Patek; Giuseppe De Nicolao; Claudio Cobelli; Boris P. Kovatchev

Background: Advancements in subcutaneous continuous glucose monitoring and subcutaneous insulin delivery are stimulating the development of a minimally invasive artificial pancreas that facilitates optimal glycemic regulation in diabetes. The key component of such a system is the blood glucose controller for which different design strategies have been investigated in the literature. In order to evaluate and compare the efficacy of the various algorithms, several performance indices have been proposed. Methods: A new tool—control-variability grid analysis (CVGA)—for measuring the quality of closed-loop glucose control on a group of subjects is introduced. It is a method for visualization of the extreme glucose excursions caused by a control algorithm in a group of subjects, with each subject presented by one data point for any given observation period. A numeric assessment of the overall level of glucose regulation in the population is given by the summary outcome of the CVGA. Results: It has been shown that CVGA has multiple uses: Comparison of different patients over a given time period, of the same patient over different time periods, of different control laws, and of different tuning of the same controller on the same population. Conclusions: Control-variability grid analysis provides a summary of the quality of glycemic regulation for a population of subjects and is complementary to measures such as area under the curve or low/high blood glucose indices, which characterize a single glucose trajectory for a single subject.


IEEE Transactions on Information Theory | 2006

A Min-Plus Calculus for End-to-End Statistical Service Guarantees

Almut Burchard; Jörg Liebeherr; Stephen D. Patek

The network calculus offers an elegant framework for determining worst-case bounds on delay and backlog in a network. This paper extends the network calculus to a probabilistic framework with statistical service guarantees. The notion of a statistical service curve is presented as a probabilistic bound on the service received by an individual flow or an aggregate of flows. The problem of concatenating per-node statistical service curves to form an end-to-end (network) statistical service curve is explored. Two solution approaches are presented that can each yield statistical network service curves. The first approach requires the availability of time scale bounds at which arrivals and departures at each node are correlated. The second approach considers a service curve that describes service over time intervals. Although the latter description of service is less general, it is argued that many practically relevant service curves may be compliant to this description


Diabetes Care | 2012

Pilot Studies of Wearable Outpatient Artificial Pancreas in Type 1 Diabetes

Claudio Cobelli; Eric Renard; Boris P. Kovatchev; Patrick Keith-Hynes; Najib Ben Brahim; Jerome Place; Simone Del Favero; Marc D. Breton; Anne Farret; Daniela Bruttomesso; Eyal Dassau; Howard Zisser; Francis J. Doyle; Stephen D. Patek; Angelo Avogaro

The artificial pancreas (AP) has been tested extensively in the hospital setting (1–5). Here we describe a next logical step in AP development—the first outpatient trials of a wearable AP based on a smartphone computational platform. Following Ethical Committee approvals and ClinicalTrials.gov registration (NCT01447992 and NCT01447979), two simultaneous studies were conducted in Padova, Italy, and Montpellier, France, in October 2011, enrolling a 38-year-old female and a 52-year-old male, respectively; both were Caucasian, type 1 diabetic insulin pump users. Day 1—At 17:00, the patients arrived at hotels located within 1 km from the emergency room. Subjects’ pumps were replaced by Omnipod Insulin Management Systems. The APs were activated in open-loop mode implementing the patients’ regular routines and remote monitoring was initiated. At 20:00, the patients had dinner at a local restaurant, without dietary restrictions and then spent the night in the hotel. Day 2—At 7:00, the patients were admitted to the clinic and the APs were switched to automated closed-loop control and challenged by breakfast at 8:00 and lunch at 12:00. At 18:00, the patients moved back to the hotel; dinner was at 20:00 in a local restaurant, without dietary restrictions. Meal bolus was recommended by the APs and approved by the patients; …


Journal of diabetes science and technology | 2009

In silico preclinical trials: methodology and engineering guide to closed-loop control in type 1 diabetes mellitus.

Stephen D. Patek; B. Wayne Bequette; Marc D. Breton; Bruce Buckingham; Eyal Dassau; Francis J. Doyle; John Lum; Lalo Magni; Howard Zisser

This article sets forth guidelines for in silico (simulation-based) proof-of-concept testing of artificial pancreas control algorithms. The goal was to design a test procedure that can facilitate regulatory approval [e.g., Food and Drug Administration Investigational Device Exemption] for General Clinical Research Center experiments without preliminary testing on animals. The methodology is designed around a software package, based on a recent meal simulation model of the glucose-insulin system. Putting a premium on generality, this document starts by specifying a generic, rather abstract, meta-algorithm for control. The meta-algorithm has two main components: (1) patient assessment and tuning of control parameters, i.e., algorithmic processes for collection and processing patient data prior to closed-loop operation, and (2) controller warm-up and run-time operation, i.e., algorithmic processes for initializing controller states and managing blood glucose. The simulation-based testing methodology is designed to reveal the conceptual/mathematical operation of both main components, as applied to a large population of in silico patients with type 1 diabetes mellitus.


Journal of diabetes science and technology | 2010

Hypoglycemia Prevention via Pump Attenuation and Red-Yellow-Green “Traffic” Lights Using Continuous Glucose Monitoring and Insulin Pump Data

Colleen S. Hughes; Stephen D. Patek; Marc D. Breton; Boris P. Kovatchev

Background: Hypoglycemia has been identified as a primary barrier to optimal management of diabetes. This observation, in conjunction with the introduction of continuous glucose monitoring (CGM) devices, has set the stage for achieving tight glycemic control with systems that adjust the insulin pump settings based on measured glucose concentrations. Because system safety and system reliability are key considerations, there is a need for algorithms that reduce the risk of hypoglycemia in closed-loop, open-loop, and advisory-mode systems. More specifically, the algorithm presented here is formulated as a component of the independent safety system module proposed in the modular control-to-range architecture. Methods: We developed two algorithms for attenuating insulin pump injections, which we refer to as Brakes and Power Brakes: Brakes is a pump attenuation function computed using CGM information only, while Power Brakes is an attenuation function in which a metabolic state observer with insulin input is used in addition to CGM information to inform the level of pump attenuation. These algorithms modulate the insulin pump delivery so that the insulin injection rate is dramatically reduced when the risk of hypoglycemia is high. Additionally, we combined these algorithms with an alert system that indicates a level of hypoglycemic risk to the user. Results: We demonstrated the effectiveness of Brakes and Power Brakes in reducing the incidence of hypoglycemia in two simulated scenarios: An elevated basal rate scenario and a scenario in which a bolus is delivered for a meal that is skipped. For these scenarios, the incidence of hypoglycemia using Power Brakes was reduced by 88 and 94%, respectively, where we defined hypoglycemia based on the American Diabetes Association guidelines for defining and reporting as 70 mg/dl. In the elevated basal rate scenario, no rebounds above 180 mg/dl (the desired upper limit of the control-to-range protocol) following hypoglycemia were shown to occur. We demonstrated the way the hypoglycemia alert system can trigger the intake of carbohydrates to reduce the incidence of hypoglycemia by 98%. Conclusions: This article offers, for the first time, a method for smoothly reducing insulin delivery rate to prevent hypoglycemia in individuals with type 1 diabetes mellitus based on a mathematically formal assessment of hypoglycemic risk. In silico, we demonstrate the way this method can prevent hypoglycemia while avoiding hyperglycemia rebounds that exceed 180 mg/dl. In conjunction with the pump attenuation algorithms, this article also proposes a system for alerting an individual of their hypoglycemic risk that contains three “levels” of alerts in the form of a traffic light. This alert system can be used in an advisory mode setting to alert the user to take action when hypoglycemia is imminent (“red” light) or in a closed-loop setting where initiation of rescue action begins when the red light alert is triggered.


systems man and cybernetics | 2000

Missile defense and interceptor allocation by neuro-dynamic programming

Dimitri P. Bertsekas; Mark L. Homer; David A. Logan; Stephen D. Patek; Nils R. Sandell

This paper proposes a solution methodology for a missile defense problem involving the sequential allocation of defensive resources over a series of engagements. The problem is cast as a dynamic programming/Markovian decision problem, which is computationally intractable by exact methods because of its large number of states and its complex modeling issues. We employed a neuro-dynamic programming framework, whereby the cost-to-go function is approximated using neural network architectures that are trained on simulated data. We report on the performance obtained using several different training methods, and we compare this performance with the optimal approach.


Journal of diabetes science and technology | 2009

Control to Range for Diabetes: Functionality and Modular Architecture

Boris P. Kovatchev; Stephen D. Patek; Eyal Dassau; Francis J. Doyle; Lalo Magni; Giuseppe De Nicolao; Claudio Cobelli

Background: Closed-loop control of type 1 diabetes is receiving increasing attention due to advancement in glucose sensor and insulin pump technology. Here the function and structure of a class of control algorithms designed to exert control to range, defined as insulin treatment optimizing glycemia within a predefined target range by preventing extreme glucose fluctuations, are studied. Methods: The main contribution of the article is definition of a modular architecture for control to range. Emphasis is on system specifications rather than algorithmic realization. The key system architecture elements are two interacting modules: range correction module, which assesses the risk for incipient hyper- or hypoglycemia and adjusts insulin rate accordingly, and safety supervision module, which assesses the risk for hypoglycemia and attenuates or discontinues insulin delivery when necessary. The novel engineering concept of range correction module is that algorithm action is relative to a nominal open-loop strategy—a predefined combination of basal rate and boluses believed to be optimal under nominal conditions. Results: A proof of concept of the feasibility of our control-to-range strategy is illustrated by using a prototypal implementation tested in silico on patient use cases. These functional and architectural distinctions provide several advantages, including (i) significant insulin delivery corrections are only made if relevant risks are detected; (ii) drawbacks of integral action are avoided, e.g., undershoots with consequent hypoglycemic risks; (iii) a simple linear model is sufficient and complex algorithmic constraints are replaced by safety supervision; and (iv) the nominal profile provides straightforward individualization for each patient. Conclusions: We believe that the modular control-to-range system is the best approach to incremental development, regulatory approval, industrial deployment, and clinical acceptance of closed-loop control for diabetes.

Collaboration


Dive into the Stephen D. Patek's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Howard Zisser

University of California

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge