Stephen M. Ronayne
University of Melbourne
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Stephen M. Ronayne.
Nature Biotechnology | 2016
Thomas J. Oxley; Nicholas L. Opie; Sam E. John; Gil S. Rind; Stephen M. Ronayne; Tracey Wheeler; Jack W. Judy; Alan James McDonald; Anthony Dornom; Timothy John Haynes Lovell; Christopher Steward; David J. Garrett; Bradford A. Moffat; E. Lui; Nawaf Yassi; Bruce C.V. Campbell; Yan T. Wong; Kate Fox; Ewan S. Nurse; Iwan E. Bennett; Sébastien H. Bauquier; Kishan Liyanage; Nicole R. van der Nagel; Piero Perucca; Arman Ahnood; Katherine P. Gill; Bernard Yan; Leonid Churilov; Chris French; Patricia Desmond
High-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.
international conference of the ieee engineering in medicine and biology society | 2016
Yan T. Wong; Nicholas L. Opie; Sam E. John; Giulia Gerboni; Gil S. Rind; Stephen M. Ronayne; Kate Fox; Thomas J. Oxley; David B. Grayden
A major challenge facing neural prostheses is the development of electrodes that are well tolerated by the brain and body. A novel way to circumvent the need to perform an invasive craniotomy and penetration of the blood-brain barrier to implant electrodes, is to guide electrodes up into the cerebral veins and place electrodes on the vessel walls adjacent to neuronal populations. To aid in the development of these stent based devices, microelectrodes manufactured from Nitinol would allow electrodes to be implanted via a catheter and then once deployed, alter their shape to conform to the vessel walls. However, there is a paucity of data on whether Nitinol is a suitable material to record neural signals. Here we show that Nitinol is tolerated by the body and that it can effectively measure neural signals. Specifically, we electrochemically evaluate Nitinol electrodes in blood and record visually evoked potentials from sheep.A major challenge facing neural prostheses is the development of electrodes that are well tolerated by the brain and body. A novel way to circumvent the need to perform an invasive craniotomy and penetration of the blood-brain barrier to implant electrodes, is to guide electrodes up into the cerebral veins and place electrodes on the vessel walls adjacent to neuronal populations. To aid in the development of these stent based devices, microelectrodes manufactured from Nitinol would allow electrodes to be implanted via a catheter and then once deployed, alter their shape to conform to the vessel walls. However, there is a paucity of data on whether Nitinol is a suitable material to record neural signals. Here we show that Nitinol is tolerated by the body and that it can effectively measure neural signals. Specifically, we electrochemically evaluate Nitinol electrodes in blood and record visually evoked potentials from sheep.
Journal of Neurosurgery | 2017
Thomas J. Oxley; Nicholas L. Opie; Gil S. Rind; Kishan Liyanage; Sam E. John; Stephen M. Ronayne; Alan James McDonald; Anthony Dornom; Timothy John Haynes Lovell; Peter Mitchell; Iwan E. Bennett; Sébastien H. Bauquier; Leon N. Warne; Christopher Steward; David B. Grayden; Patricia Desmond; Stephen M. Davis; Terence J. O'Brien; Clive N. May
OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (< 1 mm) for a length of 40 mm, or the anterior half of the SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular herophili, and the anterior formation of the SSS. The bifurcation of the cruciate sulcal veins with the SSS was a reliable predictor of the commencement of the motor area. CONCLUSIONS The ovine model for cerebral catheter venography has generalizability to the human cerebral venous system in relation to motor cortex location. This novel model may facilitate the development of the novel field of endovascular neural interfaces that may include preclinical investigations for cortical recording applications such as paralysis and epilepsy, as well as other potential applications in neuromodulation.
PLOS ONE | 2016
Kishan Liyanage; Christopher Steward; Bradford A. Moffat; Nicholas L. Opie; Gil S. Rind; Sam E. John; Stephen M. Ronayne; Clive N. May; Terence J. O'Brien; Marjorie Milne; Thomas J. Oxley
Segmentation is the process of partitioning an image into subdivisions and can be applied to medical images to isolate anatomical or pathological areas for further analysis. This process can be done manually or automated by the use of image processing computer packages. Atlas-based segmentation automates this process by the use of a pre-labelled template and a registration algorithm. We developed an ovine brain atlas that can be used as a model for neurological conditions such as Parkinson’s disease and focal epilepsy. 17 female Corriedale ovine brains were imaged in-vivo in a 1.5T (low-resolution) MRI scanner. 13 of the low-resolution images were combined using a template construction algorithm to form a low-resolution template. The template was labelled to form an atlas and tested by comparing manual with atlas-based segmentations against the remaining four low-resolution images. The comparisons were in the form of similarity metrics used in previous segmentation research. Dice Similarity Coefficients were utilised to determine the degree of overlap between eight independent, manual and atlas-based segmentations, with values ranging from 0 (no overlap) to 1 (complete overlap). For 7 of these 8 segmented areas, we achieved a Dice Similarity Coefficient of 0.5–0.8. The amygdala was difficult to segment due to its variable location and similar intensity to surrounding tissues resulting in Dice Coefficients of 0.0–0.2. We developed a low resolution ovine brain atlas with eight clinically relevant areas labelled. This brain atlas performed comparably to prior human atlases described in the literature and to intra-observer error providing an atlas that can be used to guide further research using ovine brains as a model and is hosted online for public access.
Scientific Reports | 2018
Sam E. John; Nicholas L. Opie; Yan T. Wong; Gil S. Rind; Stephen M. Ronayne; Giulia Gerboni; Sébastien H. Bauquier; Terence J. O’Brien; Clive N. May; David B. Grayden; Thomas J. Oxley
Recent work has demonstrated the feasibility of minimally-invasive implantation of electrodes into a cortical blood vessel. However, the effect of the dura and blood vessel on recording signal quality is not understood and may be a critical factor impacting implementation of a closed-loop endovascular neuromodulation system. The present work compares the performance and recording signal quality of a minimally-invasive endovascular neural interface with conventional subdural and epidural interfaces. We compared bandwidth, signal-to-noise ratio, and spatial resolution of recorded cortical signals using subdural, epidural and endovascular arrays four weeks after implantation in sheep. We show that the quality of the signals (bandwidth and signal-to-noise ratio) of the endovascular neural interface is not significantly different from conventional neural sensors. However, the spatial resolution depends on the array location and the frequency of recording. We also show that there is a direct correlation between the signal-noise-ratio and classification accuracy, and that decoding accuracy is comparable between electrode arrays. These results support the consideration for use of an endovascular neural interface in a clinical trial of a novel closed-loop neuromodulation technology.
Archive | 2017
Thomas J. Oxley; Nicholas L. Opie; Sam E. John; Gil S. Rind; Stephen M. Ronayne; Anthony N. Burkitt; David B. Grayden; Clive N. May; Terence J. O’Brien
Intracranial electrode arrays for recording and stimulating electrical brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. When compared to scalp electroencephalography (EEG), cortical recordings have demonstrated superior spatial resolution and consequently a greater potential for cognitive command output. Traditional cortical arrays require direct implantation into the brain via open craniotomy, which is a delicate and lengthy procedure. This can lead to inflammatory tissue responses amongst other clinical complications and has necessitated the development of minimally invasive methods that circumvent or mitigate brain trauma. In this study, we demonstrate the feasibility of chronically recording brain activity from within an external cerebral vein using a passive stent - electrode recording array (stentrode). We achieved implantation into a superficial cortical vein lying adjacent to the motor cortex using catheter angiography. Access was made via vascular puncture in the external jugular vein in the neck. Following successful implantation, we demonstrated neural recordings in freely moving sheep for time periods up to 190 days. Venous internal lumen patency was preserved for the duration of implantation. Spectral content and bandwidth of vascular electrocorticography were found to be comparable to those of recordings from epidural surface arrays.
Neuroscience & Biobehavioral Reviews | 2017
Sam E. John; Timothy John Haynes Lovell; Nicholas L. Opie; Stefan Wilson; Theodore C. Scordas; Yan T. Wong; Gil S. Rind; Stephen M. Ronayne; Sébastien H. Bauquier; Clive N. May; David B. Grayden; Terence J. O’Brien; Thomas J. Oxley
HIGHLIGHTSSheep display complex behaviors such as facial recognition, emotion, and memory.Sheep motor cortex is responsible for goal‐directed effector independent tasks.Sheep brain has similar structure and grouping to other higher‐order mammals.Sheep have less clearly defined somatotopy than humans. ABSTRACT In recent years, sheep (Ovis aries) have emerged as a useful animal model for neurological research due to their relatively large brain and blood vessel size, their cortical architecture, and their docile temperament. However, the functional anatomy of sheep brain is not as well studied as that of non‐human primates, rodents, and felines. For example, while the location of the sheep motor cortex has been known for many years, there have been few studies of the somatotopy of the motor cortex and there were a range of discrepancies across them. The motivation for this review is to provide a definitive resource for studies of the sheep motor cortex. This work critically reviews the literature examining the organization of the motor cortex in sheep, utilizing studies that have applied direct electrical stimulation and histological methods A clearer understanding of the sheep brain will facilitate and progress the use of this species as a scientific animal model for neurological research.
Journal of Neural Engineering | 2016
Nicholas L. Opie; Sam E. John; Gil S. Rind; Stephen M. Ronayne; David B. Grayden; Anthony N. Burkitt; Clive N. May; Terence J. O'Brien; Thomas J. Oxley
IEEE Transactions on Biomedical Engineering | 2017
Nicholas L. Opie; Nicole R. van der Nagel; Sam E. John; Kirstan A. Vessey; Gil S. Rind; Stephen M. Ronayne; Erica L. Fletcher; Clive N. May; Terence J. O'Brien; Thomas J. Oxley
IEEE Transactions on Biomedical Engineering | 2018
Sam E. John; Nicholas V. Apollo; Nicholas L. Opie; Gil S. Rind; Stephen M. Ronayne; Clive N. May; Thomas J. Oxley; David B. Grayden