Stephen W. Linderman
Washington University in St. Louis
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Stephen W. Linderman.
Stem Cell Research & Therapy | 2016
Hua Shen; Ioannis Kormpakis; Necat Havlioglu; Stephen W. Linderman; Shelly E. Sakiyama-Elbert; Isaac E. Erickson; Thomas I. Zarembinski; Matthew J. Silva; Richard H. Gelberman; Stavros Thomopoulos
BackgroundThe clinical outcomes following intrasynovial flexor tendon repair are highly variable. Excessive inflammation is a principal factor underlying the formation of adhesions at the repair surface and affecting matrix regeneration at the repair center that limit tendon excursion and impair tendon healing. A previous in-vitro study revealed that adipose-derived mesenchymal stromal cells (ASCs) modulate tendon fibroblast response to macrophage-induced inflammation. The goal of the current study was therefore to explore the effectiveness of autologous ASCs on the inflammatory stage of intrasynovial tendon healing in vivo using a clinically relevant animal model.MethodsZone II flexor tendon transections and suture repairs were performed in a canine model. Autologous ASC sheets were delivered to the surface of repaired tendons. Seven days after repair, the effects of ASCs on tendon healing, with a focus on the inflammatory response, were evaluated using gene expression assays, immunostaining, and histological assessments.ResultsASCs delivered via the cell sheet infiltrated the host tendon, including the repair surface and the space between the tendon ends, as viewed histologically by tracking GFP-expressing ASCs. Gene expression results demonstrated that ASCs promoted a regenerative/anti-inflammatory M2 macrophage phenotype and regulated tendon matrix remodeling. Specifically, there were significant increases in M2-stimulator (IL-4), marker (CD163 and MRC1), and effector (VEGF) gene expression in ASC-sheet treated tendons compared with nontreated tendons. When examining changes in extracellular matrix expression, tendon injury caused a significant increase in scar-associated COL3A1 expression and reductions in COL2A1 and ACAN expression. The ASC treatment effectively counteracted these changes, returning the expression levels of these genes closer to normal. Immunostaining further confirmed that ASC treatment increased CD163+ M2 cells in the repaired tendons and suppressed cell apoptosis at the repair site.ConclusionsThis study provides a novel approach for delivering ASCs with outcomes indicating potential for substantial modulation of the inflammatory environment and enhancement of tendon healing after flexor tendon repair.
Acta Biomaterialia | 2015
Stephen W. Linderman; Ioannis Kormpakis; Richard H. Gelberman; Victor Birman; Ulrike G. K. Wegst; Guy M. Genin; Stavros Thomopoulos
Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model.
Interface Focus | 2016
Lester Smith; Alix C. Deymier; John J. Boyle; Zhen Li; Stephen W. Linderman; Jill Dill Pasteris; Younan Xia; Guy M. Genin; Stavros Thomopoulos
Functionally graded, mineralized collagen tissues exist at soft-to-hard material attachments throughout the body. However, the details of how collagen and hydroxyapatite mineral (HA) interact are not fully understood, hampering efforts to develop tissue-engineered constructs that can assist with repair of injuries at the attachments of soft tissues to bone. In this study, spatial control of mineralization was achieved in collagen matrices using simulated body fluids (SBFs). Based upon previous observations of poor bonding between reconstituted collagen and HA deposited using SBF, we hypothesized that mineralizing collagen in the presence of fetuin (which inhibits surface mineralization) would lead to more mineral deposition within the scaffold and therefore a greater increase in stiffness and toughness compared with collagen mineralized without fetuin. We tested this hypothesis through integrated synthesis, mechanical testing and modelling of graded, mineralized reconstituted collagen constructs. Results supported the hypothesis, and further suggested that mineralization on the interior of reconstituted collagen constructs, as promoted by fetuin, led to superior bonding between HA and collagen. The results provide us guidance for the development of mineralized collagen scaffolds, with implications for bone and tendon-to-bone tissue engineering.
Advanced Materials | 2016
Jianhua Li; Stephen W. Linderman; Chunlei Zhu; Hong Liu; Stavros Thomopoulos; Younan Xia
Surgical sutures with highly porous sheaths are developed using a swelling and freeze-drying procedure without compromising their mechanical properties. The modified sutures show a high capacity for loading biofactors and are able to release the loaded biofactors in a sustained manner.
Clinical Orthopaedics and Related Research | 2017
Richard H. Gelberman; Stephen W. Linderman; Rohith Jayaram; Anna D. Dikina; Shelly E. Sakiyama-Elbert; Eben Alsberg; Stavros Thomopoulos; Hua Shen
BackgroundOutcomes after intrasynovial tendon repair are highly variable. An intense inflammatory cascade followed by a delayed healing response can cause adhesion formation and repair-site failure that severely impair the function of repaired digits. No effective remedies exist to fully address these issues. Cell- and growth factor-based therapies have been shown to modulate inflammation and improve cell proliferation and matrix synthesis and therefore are promising treatment approaches for intrasynovial tendon repair.Questions/Purposes(1) Can autologous adipose-derived mesenchymal stromal cells (ASCs) and recombinant bone morphogenetic protein-12 (rBMP-12) be effectively delivered to an intrasynovial flexor tendon repair without adverse effects? (2) Do autologous ASCs modulate the inflammatory response after intrasynovial tendon injury and repair? (3) Does the combined application of autologous ASCs and rBMP-12 modulate the proliferative and remodeling responses after intrasynovial tendon injury and repair?MethodsSixteen 1- to 2-year-old female canines were used in this study. Autologous ASC sheets, with and without rBMP-12, were applied to the surface of sutured flexor tendons. Fourteen days after repair, the effects of treatment were determined using quantitative PCR (six per group) for the expression of genes related to macrophage phenotype or inflammation (IL-4, CD163, VEGF, NOS2, IL-1B, and IFNG), cell proliferation (CCND1), and tendon formation (SCX, TNMD, COL1A1 and COL3A1). Proteomics analysis (four per group) was performed to examine changes in tendon protein abundances. CD146 immunostaining and hematoxylin and eosin staining (four per group) were used to detect tendon stem or progenitor cells and to semiquantitatively evaluate cellularity at the tendon repair; analyses were done blinded to group.ResultsGross inspection and cell tracing showed that autologous ASCs and rBMP-12 were delivered to the flexor tendon repair site without the deleterious effects of adhesion and repair-site gap formation. Quantitative assessment of gene and protein expression showed effects of treatment: ASC-sheet treatment modulated the postrepair inflammatory response and facilitated healing by increasing regenerative M2 macrophages (M2 marker CD204, twofold of normal, p = 0.030), inflammatory inhibitor (prostaglandin reductase 1 [PTRG1], 1.6-fold of normal, p = 0.026), and proteins involved in tendon formation (periostin [POSTN], 1.9-fold of normal, p = 0.035). Consistently, semiquantitative and qualitative evaluations of repaired tissue showed that ASC-sheet treatment reduced mononuclear cell infiltration (12% less than nontreated tendons, p = 0.021) and introduced CD146+ stem or progenitor cells to the repair site. The combined administration of ASCs and rBMP-12 further stimulated M2 macrophages by increasing IL-4 (116-fold of normal, p = 0.002) and led to the increase of M2 effector matrix metalloproteinase-12 involved in matrix remodeling (twofold of normal, p = 0.016) and reduction of a negative regulator of angiogenesis and cell migration (StAR-related lipid transfer domain protein13 [STARD13]; 84% of normal, p = 0.000), thus facilitating the proliferative stage of tendon repair.ConclusionsASCs and BMP-12 accelerated the progression of healing in the proliferative stage of tendon repair. The effects of ASCs and BMP-12 on tendon functional recovery should be evaluated in future studies.Clinical RelevanceThe cell sheet approach is an effective, biocompatible, and surgeon-friendly approach for cell and growth factor delivery during tendon repair. Combined application of ASCs and BMP-12 may accelerate intrasynovial tendon healing while suppressing the adverse inflammatory response.
PLOS ONE | 2016
Ioannis Kormpakis; Stephen W. Linderman; Stavros Thomopoulos; Richard H. Gelberman
This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4–0 or 3–0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand repairs by 21% when 4–0, and 33% when 3–0 suture was used, and caused a shift in failure mode from suture pullout to suture breakage. 8-strand repairs with half hitch loops but without a terminal knot produced equivalent mechanical properties to those without half hitch loops but with a terminal knot. 4-strand repairs were limited by the strength of the suture in all groups and, as a result, the presence of half hitch loops did not alter the mechanical properties. Overall, half hitch loops improved repair mechanics, allowing failure strength to reach the full capability of suture strength. Improving the mechanical properties of flexor tendon repair with half hitch loops has the potential to reduce the postoperative risk of gap formation and catastrophic rupture in the early postoperative period.
Operative Techniques in Orthopaedics | 2016
Stephen W. Linderman; Richard H. Gelberman; Stavros Thomopoulos; Hua Shen
The two primary factors leading to poor clinical results after intrasynovial tendon repair are adhesion formation within the digital sheath and repair-site elongation and rupture. As the outcomes following modern tendon multi-strand repair and controlled rehabilitation techniques are often unsatisfactory, alternative approaches, such as the application of growth factors and mesenchymal stem cells (MSCs), have become increasingly attractive treatment options. Successful biological therapies require carefully controlled spatiotemporal delivery of cells, growth factors, and biocompatible scaffold matrices in order to simultaneously (1) promote matrix synthesis at the tendon repair site leading to increased biomechanical strength and stiffness and (2) suppress matrix synthesis along the tendon surface and synovial sheath preventing adhesion formation. This review summarizes recent cell and biologic-based experimental treatments for flexor tendon injury, with an emphasis on large animal translational studies.
Journal of Orthopaedic Research | 2018
Stephen W. Linderman; Hua Shen; Susumu Yoneda; Rohith Jayaram; Michael Tanes; Shelly E. Sakiyama-Elbert; Younan Xia; Stavros Thomopoulos; Richard H. Gelberman
Recent growth factor, cell, and scaffold‐based experimental interventions for intrasynovial flexor tendon repair have demonstrated therapeutic potential in rodent models. However, these approaches have not achieved consistent functional improvements in large animal trials due to deleterious inflammatory reactions to delivery materials and insufficient induction of targeted biological healing responses. In this study, we achieved porous suture‐based sustained delivery of connective tissue growth factor (CTGF) into flexor tendons in a clinically relevant canine model. Repairs with CTGF‐laden sutures were mechanically competent and did not show any evidence of adhesions or other negative inflammatory reactions based on histology, gene expression, or proteomics analyses at 14 days following repair. CTGF‐laden sutures induced local cellular infiltration and a significant biological response immediately adjacent to the suture, including histological signs of angiogenesis and collagen deposition. There were no evident widespread biological effects throughout the tendon substance. There were significant differences in gene expression of the macrophage marker CD163 and anti‐apoptotic factor BCL2L1; however, these differences were not corroborated by proteomics analysis. In summary, this study provided encouraging evidence of sustained delivery of biologically active CTGF from porous sutures without signs of a negative inflammatory reaction. With the development of a safe and effective method for generating a positive local biological response, future studies can explore additional methods for enhancing intrasynovial tendon repair.
Nature Biotechnology | 2014
Avik Som; Tauseef Charanya; Stephen W. Linderman; Joshua S. Siegel
At Washington University, students and faculty have addressed challenges surrounding biomedical innovation and training through a novel and low-cost platform.
Acta Biomaterialia | 2018
Stephen W. Linderman; Mikhail Golman; Thomas R. Gardner; Victor Birman; William N. Levine; Guy M. Genin; Stavros Thomopoulos
Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. STATEMENT OF SIGNIFICANCE Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold. Experiments using idealized and clinically-relevant repairs validated these models. This work demonstrates an opportunity to dramatically improve tendon-to-bone repair strength using adhesive films with appropriate material properties.