Steve E. Franklin
Philips
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Steve E. Franklin.
Journal of Materials Science: Materials in Medicine | 2013
Kiran H. J. Dellimore; A. R. Helyer; Steve E. Franklin
This study presents a scoping review of the literature on the morbidity and mortality associated with several common complications of urinary catheterization. Data gathered from the open literature were analyzed graphically to gain insights into the most important urinary catheter induced complications. The results reveal that the most significant catheter complications are severe mechanical trauma (perforation, partial urethral damage and urinary leakage), symptomatic bacterial infection, and anaphylaxis, catheter toxicity and hypersensitivity. The data analysis also revealed that the complications with the highest morbidity are all closely related to the mechanical interaction of the catheter with the urethra. This suggests that there is a strong need for urinary catheter design to be improved to minimize mechanical interaction, especially mechanical damage to the urinary tract, and to enhance patient comfort. Several urinary catheter design directions have been proposed based on tribological principles. Among the key recommendations is that catheter manufacturers develop catheter coatings which are both hydrophilic and antibacterial, and which maintain their antibacterial patency for at least 90xa0days.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Raman Maiti; Lutz-Christian Gerhardt; Zing S. Lee; Robert A. Byers; Daniel Woods; J.A. Sanz-Herrera; Steve E. Franklin; R. Lewis; Stephen J. Matcher; Matt Carré
Stratum corneum and epidermal layers change in terms of thickness and roughness with gender, age and anatomical site. Knowledge of the mechanical and tribological properties of skin associated with these structural changes are needed to aid in the design of exoskeletons, prostheses, orthotics, body mounted sensors used for kinematics measurements and in optimum use of wearable on-body devices. In this case study, optical coherence tomography (OCT) and digital image correlation (DIC) were combined to determine skin surface strain and sub-surface deformation behaviour of the volar forearm due to natural tissue stretching. The thickness of the epidermis together with geometry changes of the dermal-epidermal junction boundary were calculated during change in the arm angle, from flexion (90°) to full extension (180°). This posture change caused an increase in skin surface Lagrange strain, typically by 25% which induced considerable morphological changes in the upper skin layers evidenced by reduction of epidermal layer thickness (20%), flattening of the dermal-epidermal junction undulation (45-50% reduction of flatness being expressed as Ra and Rz roughness profile height change) and reduction of skin surface roughness Ra and Rz (40-50%). The newly developed method, DIC combined with OCT imaging, is a powerful, fast and non-invasive methodology to study structural skin changes in real time and the tissue response provoked by mechanical loading or stretching.
Journal of The Mechanical Behavior of Biomedical Materials | 2016
Christopher Noble; Nicole Smulders; Nicola H. Green; R. Lewis; Matt Carré; Steve E. Franklin; Sheila MacNeil; Zeike A. Taylor
Large quantities of diseased tissue are required in the research and development of new generations of medical devices, for example for use in physical testing. However, these are difficult to obtain. In contrast, porcine arteries are readily available as they are regarded as waste. Therefore, reliable means of creating from porcine tissue physical models of diseased human tissue that emulate well the associated mechanical changes would be valuable. To this end, we studied the effect on mechanical response of treating porcine thoracic aorta with collagenase, elastase and glutaraldehyde. The alterations in mechanical and failure properties were assessed via uniaxial tension testing. A constitutive model composed of the Gasser-Ogden-Holzapfel model, for elastic response, and a continuum damage model, for the failure, was also employed to provide a further basis for comparison (Calvo and Peña, 2006; Gasser et al., 2006). For the concentrations used here it was found that: collagenase treated samples showed decreased fracture stress in the axial direction only; elastase treated samples showed increased fracture stress in the circumferential direction only; and glutaraldehyde samples showed no change in either direction. With respect to the proposed constitutive model, both collagenase and elastase had a strong effect on the fibre-related terms. The model more closely captured the tissue response in the circumferential direction, due to the smoother and sharper transition from damage initiation to complete failure in this direction. Finally, comparison of the results with those of tensile tests on diseased tissues suggests that these treatments indeed provide a basis for creation of physical models of diseased arteries.
Journal of Biomechanics | 2016
Christopher Noble; Nicole Smulders; R. Lewis; Matt Carré; Steve E. Franklin; Sheila MacNeil; Zeike A. Taylor
In this study, we examine the effect of collagenase, elastase and glutaraldehyde treatments on the response of porcine aorta to controlled peel testing. Specifically, the effects on the tissue׳s resistance to dissection, as quantified by critical energy release rate, are investigated. We further explore the utility of these treatments in creating model tissues whose properties emulate those of certain diseased tissues. Such model tissues would find application in, for example, development and physical testing of new endovascular devices. Controlled peel testing of fresh and treated aortic specimens was performed with a tensile testing apparatus. The resulting reaction force profiles and critical energy release rates were compared across sample classes. It was found that collagenase digestion significantly decreases resistance to peeling, elastase digestion has almost no effect, and glutaraldehyde significantly increases resistance. The implications of these findings for understanding mechanisms of disease-associated biomechanical changes, and for the creation of model tissues that emulate these changes are explored.
Journal of The Mechanical Behavior of Biomedical Materials | 2017
Christopher Noble; Olaf van der Sluis; Ruud M.J. Voncken; Oliver Burke; Steve E. Franklin; R. Lewis; Zeike A. Taylor
In this paper, we study the dissection of arterial layers by means of a stiff, planar, penetrating external body (a wedge), and formulate a novel model of the process using cohesive zone formalism. The work is motivated by a need for better understanding of, and numerical tools for simulating catheter-induced dissection, which is a potentially catastrophic complication whose mechanisms remain little understood. As well as the large deformations and rupture of the tissue, models of such a process must accurately capture the interaction between the tissue and the external body driving the dissection. The latter feature, in particular, distinguishes catheter-induced dissection from, for example, straightforward peeling, which is relatively well-studied. As a step towards such models, we study a scenario involving a geometrically simpler penetrating object (the wedge), which affords more reliable comparison with experimental observations, but which retains the key feature of dissection driven by an external body, as described. Particular emphasis is placed on assessing the reliability of cohesive zone approaches in this context. A series of wedge-driven dissection experiments on porcine aorta were undertaken, from which tissue elastic and fracture parameters were estimated. Finite element models of the experimental configuration, with tissue considered to be a hyperelastic medium, and evolution of tissue rupture modelled with a consistent large-displacement cohesive formulation, were then constructed. Model-predicted and experimentally measured reaction forces on the wedge throughout the dissection process were compared and found to agree well. The performance of the cohesive formulation in modelling externally driven dissection is finally assessed, and the prospects for numerical models of catheter-induced dissection using such approaches is considered.
Proceedings of SPIE | 2016
X. Hu; Raman Maiti; X. Liu; Lutz-Christian Gerhardt; Z. S. Lee; Robert A. Byers; Steve E. Franklin; R. Lewis; Stephen J. Matcher; Matt Carré
Bio-mechanical properties of the human skin deformed by external forces at difference skin/material interfaces attract much attention in medical research. For instance, such properties are important design factors when one designs a healthcare device, i.e., the device might be applied directly at skin/device interfaces. In this paper, we investigated the bio-mechanical properties, i.e., surface strain, morphological changes of the skin layers, etc., of the human finger-pad and forearm skin as a function of applied pressure by utilizing two non-invasive techniques, i.e., optical coherence tomography (OCT) and digital image correlation (DIC). Skin deformation results of the human finger-pad and forearm skin were obtained while pressed against a transparent optical glass plate under the action of 0.5-24 N force and stretching naturally from 90° flexion to 180° full extension respectively. The obtained OCT images showed the deformation results beneath the skin surface, however, DIC images gave overall information of strain at the surface.
Tribology International | 2016
M. Nachman; Steve E. Franklin
Tribology International | 2015
Agata Niemczyk; Miroslawa El Fray; Steve E. Franklin
Cardiovascular Engineering and Technology | 2014
Kiran H. J. Dellimore; Steve E. Franklin; Annika R. Helyer
Biotribology | 2016
Greg Hofmann; Philippe F. Jubin; Pierre Gerligand; Annabelle Gallois-Bernos; Steve E. Franklin; Nicole Smulders; Lutz-Christian Gerhardt; Sanne Valster