Steven Baete
Ghent University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Steven Baete.
Physics in Medicine and Biology | 2011
Jan Vandecasteele; S Ghysel; Steven Baete; Y De Deene
Recently, novel radiochromic leucodye micelle hydrogel dosimeters were introduced in the literature. In these studies, gel measured electron depth dose profiles were compared with ion chamber depth dose data, from which it was concluded that leucocrystal violet-type dosimeters were independent of dose rate. Similar conclusions were drawn for leucomalachite green-type dosimeters, only after pre-irradiating the samples to a homogeneous radiation dose. However, in our extensive study of the radio-physical properties of leucocrystal violet- and leucomalachite green-type dosimeters, a significant dose rate dependence was found. For a dose rate variation between 50 and 400 cGy min(-1), a maximum difference of 75% was found in optical dose sensitivity for the leucomalachite green-type dosimeter. Furthermore, the measured optical dose sensitivity of the leucomalachite green-type dosimeter was four times lower than the value previously reported in the literature. For the leucocrystal violet-type dosimeter, a maximum difference in optical dose sensitivity of 55% was found between 50 and 400 cGy min(-1). A modified composition of the leucomalachite green-type dosimeter is proposed. This dosimeter is composed of gelatin, sodium dodecyl sulfate, chloroform, trichloroacetic acid and leucomalachite green. The optical dose sensitivity amounted to 4.375 × 10(-5) cm(-1) cGy(-1) (dose rate 400 cGy min(-1)). No energy dependence for photon energies between 6 and 18 MV was found. No temperature dependence during readout was found notwithstanding a temperature dependence during irradiation of 1.90 cGy °C(-1) increase on a total dose of 100 cGy. The novel gel dosimeter formulation exhibits an improved spatial stability (2.45 × 10(-7) cm(2) s(-1) (= 0.088 mm(2) h(-1))) and good water/soft tissue equivalence. Nevertheless, the novel formulation was also found to have a significant, albeit reduced, dose rate dependence, as a maximum difference of 33% was found in optical dose sensitivity when the dose rate varied between 50 and 400 cGy min(-1). By pre-irradiating the novel leucomalachite green-type dosimeter to 500 cGy, the apparent difference in dose response between 200 and 400 cGy min(-1) was eliminated, similar to earlier findings. However, a dose response difference of 38% between 50 and 200 cGy min(-1) was still measured. On the basis of these experimental results it is concluded that the leucodye micelle gel dosimeter is not yet optimal for dose verifications of high precision radiation therapy treatments. This study, however, indicates that the dose rate dependence has a potential for improvement. Future research is necessary to further minimize the dose rate dependence through extensive chemical analysis and optimization of the gel formulation. Some insights into the physicochemical mechanisms were obtained and are discussed in this paper.
Journal of Magnetic Resonance | 2008
Steven Baete; Y De Deene; B. Masschaele; W. De Neve
The spin-spin relaxation rate R2 (=1/T2) in hydrogel foams measured by use of a multiple spin echo sequence is found to be dependent on the echo time spacing. This property, referred to as R2-dispersion, originates to a large extent from molecular self-diffusion of water within internal field gradients that result from magnetic susceptibility differences between the gel and air phase. Another contribution to the R2 relaxation rate is surface relaxation. Numerical simulations are performed to investigate the relation between the foam microstructure (the mean air bubble radius and standard deviation of the air bubble radius) and foam composition properties (such as magnetic susceptibilities, diffusion coefficient and surface relaxivity) at one hand and the R2-dispersion at the other hand. The simulated R2-dispersions of gel foam are in agreement with the measured R2-dispersions. By correlating the R2-dispersion parameters and simulated microstructure properties a semi-empirical relationship is obtained that enables the mean air bubble size to be derived from measured R2-dispersion curves. The R2-derived mean air bubble size of a hydrogel foam is in agreement with the bubble size measured with X-ray micro-CT. This illustrates the feasibility of using 1H R2-dispersion measurements to determine the size of air bubbles in hydrogel foams and of alveoli in lung tissue.
Physics in Medicine and Biology | 2011
Steven Baete; Jan Vandecasteele; Y De Deene
In (19)F MRI oximetry, a method used to image tumour hypoxia, perfluorocarbons serve as oxygenation markers. The goal of this study is to evaluate the impact of perfluorocarbon distribution and concentration in (19)F MRI oximetry through a computer simulation. The simulation studies the correspondence between (19)F measured (pO(FNMR)(2)) and actual tissue oxygen tension (pO(2)) for several tissue perfluorocarbon distributions. For this, a Krogh tissue model is implemented which incorporates the presence of perfluorocarbons in blood and tissue. That is, in tissue the perfluorocarbons are distributed homogeneously according to Gaussian diffusion profiles, or the perfluorocarbons are concentrated in the capillary wall. Using these distributions, the oxygen tension in the simulation volume is calculated. The simulated mean oxygen tension is then compared with pO(FNMR)(2), the (19)F MRI-based measure of pO(2) and with pO(0)(2), pO(2) in the absence of perfluorocarbons. The agreement between pO(FNMR)(2) and actual pO(2) is influenced by vascular density and perfluorocarbon distribution. The presence of perfluorocarbons generally gives rise to a pO(2) increase in tissue. This effect is enhanced when perfluorocarbons are also present in blood. Only the homogeneous perfluorocarbon distribution in tissue with no perfluorocarbons in blood guarantees small deviations of pO(FNMR)(2) from pO(2). Hence, perfluorocarbon distribution in tissue and blood has a serious impact on the reliability of (19)F MRI-based measures of oxygen tension. In addition, the presence of perfluorocarbons influences the actual oxygen tension. This finding may be of great importance for further development of (19)F MRI oximetry.
Magnetic Resonance Materials in Physics Biology and Medicine | 2010
Steven Baete; Jan Vandecasteele; Luc Colman; Wilfried De Neve; Yves De Deene
ObjectiveThis study presents a reproducible phantom which mimics oxygen-consuming tissue and can be used for the validation of 19F MRI oximetry.Materials and methodsThe phantom consists of a haemodialysis filter of which the outer compartment is filled with a gelatin matrix containing viable yeast cells. Perfluorocarbon emulsions can be added to the gelatin matrix to simulate sequestered perfluorocarbons. A blood-substituting perfluorocarbon fluid is pumped through the lumen of the fibres in the filter. 19F relaxometry MRI is performed with a fast 2D Look-Locker imaging sequence on a clinical 3T scanner.ResultsAcute and perfusion-related hypoxia were simulated and imaged spatially and temporally using the phantom.ConclusionsThe presented experimental setup can be used to simulate oxygen consumption by somatic cells in vivo and for validating computational biophysical models of hypoxia, as measured with 19F MRI oximetry.
4th European Conference of the International Federation for Medical and Biological Engineering / 4th European Congress for Medical and Biomedical Engineering | 2009
Steven Baete; Y De Deene
The spin-spin relaxation rate R2 (=1/T2) in hydrogel foams measured by use of a multiple spin echo sequence was found to be dependent on the echo time spacing. (Baete and De Deene. Proc. Intl. Soc. Magn. Reson. Med. 15:37, 2007). This property, referred to as R2-dispersion, originates to a large extent from molecular self-diffusion of water within internal field gradients that result from magnetic susceptibility differences between the gel and air phase. Another contribution to the R2 relaxation rate is surface relaxation. Numerical simulations are performed to investigate the relation between the foam microstructure (the mean air bubble radius and standard deviation of the air bubble radius) at one hand and the R2-dispersion at the other hand. The simulated R2-dispersions of gel foam are in agreement with measured R2-dispersions. By correlating the R2-dispersion parameters and simulated microstructure properties a relationship is obtained that enables the mean air bubble size to be derived from measured R2-dispersion curves. The R2-derived mean air bubble size of a hydrogel foam is in agreement with the bubble size measured with X-ray micro-CT. This illustrates the feasibility of using 1H R2-dispersion measurements to determine the size of air bubbles in hydrogel foams and of alveoli in lung tissue.
MAGNETIC RESONANCE IN POROUS MEDIA: Proceedings of the 9th International Bologna#N#Conference on Magnetic Resonance in Porous Media (MRPM9), including 8th Colloquium on#N#Mobile Magnetic Resonance (CMMR8) | 2008
Steven Baete; Y De Deene
The spin‐spin relaxation rate R2 ( = 1/T2) in hydrogel foams measured by use of a multi spin echo sequence is found to be dependent on the echo time spacing. This property, referred to as R2‐dispersion, originates from both surface relaxation and molecular self‐diffusion of water within internal field gradients that result from magnetic susceptibility differences between the gel and air phase. In hydrogel foams, correlations between the average air bubble size and R2‐values are found (S. Baete and Y. De Deene, Proc. Intl. Soc. Mag. Reson. Med. (15) 37, 2007.). Random walk diffusion is simulated to correlate the R2‐dispersion with the foam microstructure (i.e. the mean air bubble radius and standard deviation of the air bubble radius) and foam composition properties (i.e. magnetic susceptibilities, diffusion coefficient and surface relaxivity). Simulations of R2‐dispersion are in agreement with NMR measurements of a hydrogel foam. By correlating the R2‐dispersion parameters and microstructure properties a ...
Proceedings of the first BENELUX In Vivo MR Methods Symposium | 2007
Steven Baete; Yves De Deene
Magnetic Resonance in Porous Media : A selection of papers presented at the 9th International Bologna Conference Magnetic Resonance in Porous Media (MRPM 9), July 2008, Cambridge MA, USA | 2009
Els Fieremans; Yves De Deene; Steven Baete; Ignace Lemahieu
Archive | 2011
Steven Baete
ISMRM Benelux Chapter, 3rd Annual meeting, Abstracts | 2011
Steven Baete; Yves De Deene