Steven Lee Alderman
R. J. Reynolds Tobacco Company
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Steven Lee Alderman.
Inhalation Toxicology | 2012
Bradley J. Ingebrethsen; Stephen K. Cole; Steven Lee Alderman
The particle size distribution of aerosols produced by electronic cigarettes was measured in an undiluted state by a spectral transmission procedure and after high dilution with an electrical mobility analyzer. The undiluted e-cigarette aerosols were found to have particle diameters of average mass in the 250–450 nm range and particle number concentrations in the 109 particles/cm3 range. These measurements are comparable to those observed for tobacco burning cigarette smoke in prior studies and also measured in the current study with the spectral transmission method and with the electrical mobility procedure. Total particulate mass for the e-cigarettes calculated from the size distribution parameters measured by spectral transmission were in good agreement with replicate determinations of total particulate mass by gravimetric filter collection. In contrast, average particle diameters determined for e-cigarettes by the electrical mobility method are in the 50 nm range and total particulate masses calculated based on the suggested diameters are orders of magnitude smaller than those determined gravimetrically. This latter discrepancy, and the very small particle diameters observed, are believed to result from almost complete e-cigarette aerosol particle evaporation at the dilution levels and conditions of the electrical mobility analysis. A much smaller degree, ~20% by mass, of apparent particle evaporation was observed for tobacco burning cigarette smoke. The spectral transmission method is validated in the current study against measurements on tobacco burning cigarette smoke, which has been well characterized in prior studies, and is supported as yielding an accurate characterization of the e-cigarette aerosol particle size distribution.
Aerosol Science and Technology | 2011
Steven Lee Alderman; Bradley J. Ingebrethsen
Particle size distribution and number concentration measurements of mainstream cigarette smoke are reported for commercial cigarettes encompassing a broad range of design parameters. Measurements were made using a Cambustion DMS500 fast particulate spectrometer. Twenty-nine brand styles were evaluated using a 60-mL puff of 2-s duration taken once every 30 s. A subset of cigarettes was evaluated using additional smoking regimens to explore the influence of puff volume and filter ventilation blocking. The DMS500-derived particulate matter mass was compared with filter-collected mass to assess the reliability of the aerosol measurements. Under the 60-mL/2-s puffing condition, all puffs for all products were observed to exhibit count median diameters between 145 nm and 189 nm. Measured particle size was 12–22 nm smaller for a 60-mL puff relative to a 35-mL puff. Partial or complete filter ventilation blocking under the 60-mL/2-s puffing condition had a small effect on particle size. Some trends in particle size as a function of puff number and smoking regimen appear consistent with a tobacco-rod residence time/coagulation hypothesis; however, other observations suggest that smoke formation processes in addition to coagulation influence particle size. The DMS500 underestimates smoke particulate mass relative to gravimetric filter collection, indicating evaporation of cigarette smoke particulate matter within the instrument. Approximately 75% of the evaporated mass can be attributed to particulate phase water. Some data also suggest a possible underestimation of number concentration. This introduces a significant confounding bias in the measurements and limits the information on smoke formation that can be extracted.
Aerosol Science and Technology | 2011
Bradley J. Ingebrethsen; Steven Lee Alderman; Balager Ademe
The effect of Brownian coagulation on the particle size distribution of mainstream cigarette smoke subjected to conditions encountered in the mouth during human smoking has been examined experimentally and simulated with a numerical coagulation model. Smoke puffed into an artificial mouth was subjected to variable aging times and exhausted to a fast electrical mobility analyzer for particle size distribution measurement. The experimental results agreed well with the predictions of a sectional-based model of Brownian coagulation that allowed for the modeling of various continuous feed and fixed volume coagulation environments. Due to the steady input of fresh, smaller particles, particle growth during the filling of the mouth with smoke, a process intrinsic to the puffing maneuver, was significant but slower than that during fixed volume, static aging. Mouth hold times and initial smoke mass concentration were found to be strong determinants of the average particle size of smoke exiting the mouth into the respiratory tract during inhalation. The results also suggest that the smallest particles present in fresh smoke, those less than 0.1 μm diameter, are greatly reduced in number during the unavoidable mouth coagulation during puffing and virtually eliminated after 1 s of mouth hold.
Contributions to Tobacco Research | 2015
Steven Lee Alderman; Chen Song; Serban C. Moldoveanu; Stephen K. Cole
Abstract The relatively volatile nature of the particulate matter fraction of e-cigarette aerosols presents an experimental challenge with regard to particle size distribution measure-ments. This is particularly true for instruments requiring a high degree of aerosol dilution. This was illustrated in a previous study, where average particle diameters in the 10-50 nm range were determined by a high-dilution, electrical mobility method. Total particulate matter (TPM) masses calculated based on those diameters were orders of magnitude smaller than gravimetrically determined TPM. This discrepancy was believed to result from almost complete particle evaporation at the dilution levels of the electrical mobility analysis. The same study described a spectral transmission measurement of e-cigarette particle size in an undiluted state, and reported particles from 210-380 nm count median diameter. Observed particle number concentrations were in the 109 particles/cm3 range. Additional particle size measurements described here also found e-cigarette particle size to be in the 260-320 nm count median diameter range. Cambridge filter pads have been used for decades to determine TPM yields of tobacco burning cigarettes, and collection of e-cigarette TPM by fibrous filters is predicted to be a highly efficient process over a wide range of filtration flow rates. The results presented in this work provide support for this hypothesis. Described here is a study in which e-cigarette aerosols were collected on Cambridge filters with adsorbent traps placed downstream in an effort to capture any material passing through the filter. Amounts of glycerin, propylene glycol, nicotine, and water were quantified on the filter and downstream trap. Glycerin, propylene glycol, and nicotine were effciently captured (> 98%) by the upstream Cambridge filter, and a correlation was observed between filtration efficiency and the partial vapor pressure of each component. The present analysis was largely inconclusive with regard to filter efficiency and particle-vapor partitioning of water. [Beitr. Tabakforsch. Int. 26 (2014) 183-190]
Archive | 2012
William Robert Collett; Stephen Benson Sears; Dennis Lee Potter; Steven Lee Alderman; Mo Kebaili
Archive | 2013
Andries Don Sebastian; Karen V. Williams; Stephen Benson Sears; Bradley J. Ingebrethsen; Balager Ademe; Steven Lee Alderman; William Robert Collett; Grady Lance Dooly; Iii Charles Jacob Novak
Archive | 2013
Stephen Benson Sears; Timothy Brian Nestor; Iii Charles Jacob Novak; Steven Lee Alderman; Michael Ryan Galloway; Quentin Paul Guenther; Frederic Philippe Ampolini; Raymond Charles Henry; Allen Michael East; Scott Ingham; Glen Kimsey; Keith William Anderson
Archive | 2013
John Depiano; David Smith; Charles Jacob Novak; Frank S. Silveira; Steven Lee Alderman; Grady Lance Dooly; Frederic Philippe Ampolini; Timothy Brian Nestor; Quentin Paul Guenther; Stephen Benson Sears; John William Wolber; Michael Laine
Archive | 2009
Andries Don Sebastian; Billy Tyrone Conner; Chandra Kumar Banerjee; Steven Lee Alderman; Paul E. Braxton; Carolyn Rierson Carpenter; Alvaro Gonzalez-Parra; Bradley James Ingebrethsen; Kristen L. Murray; Timothy Brian Nestor; Evon Llewellyn Crooks
Archive | 2013
John Depiano; David Smith; Patsy Anthony Coppola; Charles Jacob Novak; Steven Lee Alderman; James William Mcclellan; John William Wolber; Frank S. Silveira; Michael Laine; Paul Andrew Brinkley; Grady Lance Dooly