Dive into the research topics where Steven W. Graves is active.

Publication


Featured researches published by Steven W. Graves.


Analytical Chemistry | 2010

Particle Focusing in Staged Inertial Microfluidic Devices for Flow Cytometry

John Oakey; Robert W. Applegate; Erik Arellano; Dino Di Carlo; Steven W. Graves; Mehmet Toner

Microfluidic inertial focusing has been demonstrated to be an effective method for passively positioning microparticles and cells without the assistance of sheath fluid. Because inertial focusing produces well-defined lateral equilibrium particle positions in addition to highly regulated interparticle spacing, its value in flow cytometry has been suggested. Particle focusing occurs in straight channels and can be manipulated through cross sectional channel geometry by the introduction of curvature. Here, we present a staged channel design consisting of both curved and straight sections that combine to order particles into a single streamline with longitudinal spacing. We have evaluated the performance of these staged inertial focusing channels using standard flow cytometry methods that make use of calibration microspheres. Our analysis has determined the measurement precision and resolution, as a function of flow velocity and particle concentration that is provided by these channels. These devices were found to operate with increasing effectiveness at higher flow rates and particle concentrations, within the examined ranges, which is ideal for high throughput analysis. Further, the prototype flow cytometer equipped with an inertial focusing microchannel matched the resolution provided by a commercial hydrodynamic focusing flow cytometer. Most notably, our analysis indicates that the inertial focusing channels virtually eliminated particle coincidence at the analysis point. These properties suggest a potentially significant role for inertial focusing in the development of inexpensive flow cytometry-based diagnostics and in applications requiring the analysis of high particle concentrations.


Cytometry Part A | 2008

A flow cytometer for the measurement of Raman spectra

Dakota A. Watson; Leif O. Brown; Daniel F. Gaskill; Mark A. Naivar; Steven W. Graves; Stephen K. Doorn; John P. Nolan

Multiparameter measurements in flow cytometry are limited by the broad emission spectra of fluorescent labels. By contrast, Raman spectra are notable for their narrow spectral features. To increase the multiparameter analysis capabilities of flow cytometry, we investigated the possibility of measuring Raman signals in a flow cytometry‐based system. We constructed a Raman Spectral Flow Cytometer, substituting a spectrograph and CCD detector for the traditional mirrors, optical filters, and photomultiplier tubes. Excitation at 633 nm was provided by a HeNe laser, and forward‐angle light scatter is used to trigger acquisition of complete spectra from individual particles. Microspheres were labeled with nanoparticle surface enhanced Raman scattering (SERS) tags and measured using the RSFC. Fluorescence and Raman spectra from labeled microspheres were acquired using the Raman Spectral Flow Cytometer. SERS spectral intensities were dependent on integration time, laser power, and detector pixel binning. Spectra from particles labeled with one each of four different SERS tags could be distinguished by either a virtual bandpass approach using commercial flow cytometry data analysis software or by principal component analysis. Raman flow cytometry opens up new possibilities for highly multiparameter and multiplexed measurements of cells and other particles using a simple optical design and a single detector and light source.


Cytometry Part A | 2006

Ultrasonic particle‐concentration for sheathless focusing of particles for analysis in a flow cytometer

Gregory Goddard; John C. Martin; Steven W. Graves; Gregory Kaduchak

The development of inexpensive small flow cytometers is recognized as an important goal for many applications ranging from medical uses in developing countries for disease diagnosis to use as an analytical platform in support of homeland defense. Although hydrodynamic focusing is highly effective at particle positioning, the use of sheath fluid increases assay cost and reduces instrument utility for field and autonomous remote operations.


Small | 2012

Inertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams

Daniel R. Gossett; Henry Tat Kwong Tse; Jaideep S. Dudani; Keisuke Goda; Travis A. Woods; Steven W. Graves; Dino Di Carlo

A general strategy for controlling particle movement across streams would enable new capabilities in single-cell analysis, solid-phase reaction control, and biophysics research. Transferring cells across streams is difficult to achieve in a well-controlled manner, since it requires precise control of fluid flow along with external force fields or precisely manufactured mechanical structures. Herein a strategy is introduced for particle transfer based on passive inertial lift forces and shifts in the distribution of these forces for channels with shifting aspect ratios. Uniquely, use of the dominant wall-effect lift parallel to the particle rotation direction is explored and utilized to achieve controllable cross-stream motion. In this way, particles are positioned to migrate across laminar streams and enter a new solution without significant disturbance of the interface at rates exceeding 1000 particles per second and sub-millisecond transfer times. The capabilities of rapid inertial solution exchange (RInSE) for preparation of hematological samples and other cellular assays are demonstrated. Lastly, improvements to inline flow cytometry after RInSE of excess fluorescent dye and focusing for downstream analysis are characterized. The described approach is simply applied to manipulating cells and particles and quickly exposing them to or removing them from a reacting solution, with broader applications in control and analysis of low affinity interactions on cells or particles.


Journal of Biological Chemistry | 2003

α4β1 integrin affinity changes govern cell adhesion

Alexandre Chigaev; Gordon Zwartz; Steven W. Graves; Denise C. Dwyer; Hisashi Tsuji; Terry D. Foutz; Bruce S. Edwards; Eric R. Prossnitz; Richard S. Larson; Larry A. Sklar

Integrin α4β1 is a receptor for vascular cell adhesion molecule-1 and fibronectin. It is important in lymphopoiesis, inflammatory recruitment of leukocytes, and other situations that require cell adhesion to the vascular endothelium. The avidity of the cells expressing α4β1 integrin can be rapidly changed by chemokines and chemoattractants. Different mechanisms, including changes in the number of interacting molecules due to the alteration of the receptor topology or changes in the affinity of the individual bonds, have been proposed to explain the nature of these fast changes in avidity. Recently, we described a fluorescent LDV-containing small molecule, which we used to monitor the affinity changes on live cells in real time (Chigaev, A., Blenc, A. M., Braaten, J. V., Kumaraswamy, N., Kepley, C. L., Andrews, R. P., Oliver, J. M., Edwards, B. S., Prossnitz, E. R., Larson, R. S. et al. (2001) J. Biol. Chem. 276, 48670–48678). Here we show that the affinity of the small molecule probe as well as the native ligand vascular cell adhesion molecule-1 varies in parallel when the integrin is modulated with divalent cations and that the affinity modulation leads to the changes in cell avidity. Using formyl peptide receptor-transfected U937 cells, we further show that the time course of avidity changes in response to the receptor activation coincides with the time course of the affinity changes. Taken together, these data are consistent with the idea that affinity regulation is a major factor that governs the avidity of cell adhesion mediated by the α4 integrin.


Lab on a Chip | 2014

The intersection of flow cytometry with microfluidics and microfabrication

Menake E. Piyasena; Steven W. Graves

A modern flow cytometer can analyze and sort particles on a one by one basis at rates of 50,000 particles per second. Flow cytometers can also measure as many as 17 channels of fluorescence, several angles of scattered light, and other non-optical parameters such as particle impedance. More specialized flow cytometers can provide even greater analysis power, such as single molecule detection, imaging, and full spectral collection, at reduced rates. These capabilities have made flow cytometers an invaluable tool for numerous applications including cellular immunophenotyping, CD4+ T-cell counting, multiplex microsphere analysis, high-throughput screening, and rare cell analysis and sorting. Many bio-analytical techniques have been influenced by the advent of microfluidics as a component in analytical tools and flow cytometry is no exception. Here we detail the functions and uses of a modern flow cytometer, review the recent and historical contributions of microfluidics and microfabricated devices to field of flow cytometry, examine current application areas, and suggest opportunities for the synergistic application of microfabrication approaches to modern flow cytometry.


Analytical Chemistry | 2012

Multinode acoustic focusing for parallel flow cytometry

Menake E. Piyasena; Pearlson P. Austin Suthanthiraraj; Robert W. Applegate; Andrew M. Goumas; Travis A. Woods; Gabriel P. Lopez; Steven W. Graves

Flow cytometry can simultaneously measure and analyze multiple properties of single cells or particles with high sensitivity and precision. Yet, conventional flow cytometers have fundamental limitations with regards to analyzing particles larger than about 70 μm, analyzing at flow rates greater than a few hundred microliters per minute, and providing analysis rates greater than 50,000 per second. To overcome these limits, we have developed multinode acoustic focusing flow cells that can position particles (as small as a red blood cell and as large as 107 μm in diameter) into as many as 37 parallel flow streams. We demonstrate the potential of such flow cells for the development of high throughput, parallel flow cytometers by precision focusing of flow cytometry alignment microspheres, red blood cells, and the analysis of a CD4+ cellular immunophenotyping assay. This approach will have significant impact toward the creation of high throughput flow cytometers for rare cell detection applications (e.g., circulating tumor cells), applications requiring large particle analysis, and high volume flow cytometry.


Cytometry Part A | 2006

Single particle high resolution spectral analysis flow cytometry

Gregory Goddard; John C. Martin; Mark A. Naivar; Peter M. Goodwin; Steven W. Graves; Robb Habbersett; John P. Nolan; James H. Jett

While conventional multiparameter flow cytometers have proven highly successful, there are several types of analytical measurements that would benefit from a more comprehensive and flexible approach to spectral analysis including, but certainly not limited to spectral deconvolution of overlapping emission spectra, fluorescence resonance energy transfer measurements, metachromic dye analysis, free versus bound dye resolution, and Raman spectroscopy.


Bioinformatics | 2000

DNAssist: the integrated editing and analysis of molecular biology sequences in Windows

Hugh-George Patterton; Steven W. Graves

MOTIVATION The programs currently available for the analysis of nucleic acid and protein sequences suffer from a variety of problems: Web-based programs often require inconvenient reformatting of sequences when proceeding from one analysis to the next, and commercial-console-based programs are cost prohibitive. Here, we report the development of DNASSIST:, an inexpensive, multiple-document, interface program for the fully integrated editing and analysis of nucleic acid and protein sequences in the familiar environment of Microsoft Windows.


Journal of the American Chemical Society | 2010

High-Resolution Spectral Analysis of Individual SERS-Active Nanoparticles in Flow

Gregory Goddard; Leif O. Brown; Robb Habbersett; Christina I. Brady; John C. Martin; Steven W. Graves; James P. Freyer; Stephen K. Doorn

Nanoparticle spectroscopic tags based on surface enhanced Raman scattering (SERS) are playing an increasingly important role in bioassay and imaging applications. The ability to rapidly characterize large populations of such tags spectroscopically in a high-throughput flow-based platform will open new areas for their application and provide new tools for advancing their development. We demonstrate here a high-resolution spectral flow cytometer capable of acquiring Raman spectra of individual SERS-tags at flow rates of hundreds of particles per second, while maintaining the spectral resolution required to make full use of the detailed information encoded in the Raman signature for advanced multiplexing needs. The approach allows multiple optical parameters to be acquired simultaneously over thousands of individual nanoparticle tags. Characteristics such as tag size, brightness, and spectral uniformity are correlated on a per-particle basis. The tags evaluated here display highly uniform spectral signatures, but with greater variability in brightness. Subpopulations in the SERS response, not apparent in ensemble measurements, are also shown to exist. Relating tag variability to synthesis parameters makes flow-based spectral characterization a powerful tool for advancing particle development through its ability to provide rapid feedback on strategies aimed at constraining desired tag properties. Evidence for single-tag signal saturation at high excitation power densities is also shown, suggesting a role for high-throughput investigation of fundamental properties of the SERS tags as well.

Collaboration


Dive into the Steven W. Graves's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

John P. Nolan

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

John C. Martin

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Larry A. Sklar

University of New Mexico

View shared research outputs
Top Co-Authors

Avatar

Carl W. Brown

University of New Mexico

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gregory Goddard

Los Alamos National Laboratory

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge