Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sung-Ae Son is active.

Publication


Featured researches published by Sung-Ae Son.


Diabetologia | 2005

The effects of the overexpression of recombinant uncoupling protein 2 on proliferation, migration and plasminogen activator inhibitor 1 expression in human vascular smooth muscle cells

Jung-Hoon Park; Keun-Gyu Park; Hyun Jung Kim; Kang Hg; Jong Deok Ahn; Heung Sik Kim; Kim Ym; Sung-Ae Son; In-Suk Kim; Yoo-Mi Kim; Chi Dae Kim; Kyoo-Hyung Lee; In-Seon Lee

Aims/hypothesisIncreased oxidative stress in vascular smooth muscle cells (VSMCs) has been implicated in the pathogenesis of accelerated atherosclerosis in patients with diabetes mellitus. Uncoupling protein 2 (UCP-2) is an important regulator of intracellular reactive oxygen species (ROS) production. We hypothesised that UCP-2 functions as an inhibitor of the atherosclerotic process in VSMCs.MethodsOverexpression of human UCP-2 was performed in primary cultured human VSMCs (HVSMCs) via adenovirus-mediated gene transfer. Its effects on ROS production, AP-1 activity, plasminogen activator inhibitor 1 (PAI-1) gene expression, and cellular proliferation and migration were measured in response to high glucose and angiotensin II (Ang II) concentrations, two major factors in the pathogenesis of atherosclerosis in patients with diabetes and hypertension. Mitochondrial membrane potential and NAD(P)H oxidase activity were also measured.ResultsHigh glucose and Ang II caused transient mitochondrial membrane hyperpolarisation. They also significantly stimulated ROS production, NAD(P)H oxidase activity, mitochondrial membrane potential, AP-1 activity, PAI-1 mRNA expression, and proliferation and migration of HVSMCs. Adenovirus-mediated transfer of the UCP-2 gene reversed all of these effects.Conclusions/interpretationThe present study demonstrates that UCP-2 can modify atherosclerotic processes in HVSMCs in response to high glucose and Ang II. Our data suggest that agents increasing UCP-2 expression in vascular cells may help prevent the development and progression of atherosclerosis in patients with diabetes and hypertension.


Restorative Dentistry and Endodontics | 2014

The effect of resin thickness on polymerization characteristics of silorane-based composite resin

Sung-Ae Son; Hyoung-Mee Roh; Bock Hur; Yong Hoon Kwon; Jeong-Kil Park

Objectives This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukeys test at p < 0.05 level. Results The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.


The Journal of Advanced Prosthodontics | 2015

Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements.

Seung-Hyun Youm; Kyoung-Hwa Jung; Sung-Ae Son; Yong Hoon Kwon; Jeong-Kil Park

PURPOSE The aim was to evaluate the effect of curing mode and different dentin surface pretreatment on microtensile bond strength (µTBS) of self-adhesive resin cements. MATERIALS AND METHODS Thirty-six extracted human permanent molars were sectioned horizontally exposing flat dentin surface. The teeth were divided into 12 groups (3 teeth/group) according to the dentin surface pretreatment methods (control, 18% EDTA, 10% Polyacrylic acid) and curing mode (self-curing vs. light-curing) of cement. After pretreatment, composite resin blocks were cemented with the following: (a) G-CEM LinkAce; (b) RelyX U200, followed by either self-curing or light-curing. After storage, the teeth were sectioned and µTBS test was performed using a microtensile testing machine. The data was statistically analyzed using one-way ANOVA, Student T-test and Scheffes post-hoc test at P<.05 level. RESULTS For G-CEM LinkAce cement groups, polyacrylic acid pretreatment showed the highest µTBS in the self-cured group. In the light-cured group, no significant improvements were observed according to the dentin surface pretreatment. There were no significant differences between curing modes. Both dentin surface pretreatment methods helped to increase the µTBS of RelyX U200 resin cement significantly and degree of pretreatment effect was similar. No significant differences were found regarding curing modes except control groups. In the comparisons of two self-adhesive resin cements, all groups within the same pretreatment and curing mode were significantly different excluding self-cured control groups. CONCLUSION Selecting RelyX U200 used in this study and application of dentin surface pretreatment with EDTA and polyacrylic acid might be recommended to enhance the bond strength of cement to dentin.


The Journal of Advanced Prosthodontics | 2013

The effect of additional etching and curing mechanism of composite resin on the dentin bond strength.

In-Su Lee; Sung-Ae Son; Bock Hur; Yong Hoon Kwon; Jeong-Kil Park

PURPOSE The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ×20 magnification. The data was analyzed using a one-way ANOVA and Scheffes post-hoc test (α=.05). RESULTS Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.


Restorative Dentistry and Endodontics | 2015

Effect of additional etching and ethanol-wet bonding on the dentin bond strength of one-step self-etch adhesives.

Joonghee Ahn; Kyoung-Hwa Jung; Sung-Ae Son; Bock Hur; Yong Hoon Kwon; Jeong-Kil Park

Objectives This study examined the effects of additional acid etching on the dentin bond strength of one-step self-etch adhesives with different compositions and pH. The effect of ethanol wetting on etched dentin bond strength of self-etch adhesives was also evaluated. Materials and Methods Forty-two human permanent molars were classified into 21 groups according to the adhesive types (Clearfil SE Bond [SE, control]; G-aenial Bond [GB]; Xeno V [XV]; Beauti Bond [BB]; Adper Easy Bond [AE]; Single Bond Universal [SU]; All Bond Universal [AU]), and the dentin conditioning methods. Composite resins were placed on the dentin surfaces, and the teeth were sectioned. The microtensile bond strength was measured, and the failure mode of the fractured specimens was examined. The data were analyzed statistically using two-way ANOVA and Duncans post hoc test. Results In GB, XV and SE (pH ≤ 2), the bond strength was decreased significantly when the dentin was etched (p < 0.05). In BB, AE and SU (pH 2.4 - 2.7), additional etching did not affect the bond strength (p > 0.05). In AU (pH = 3.2), additional etching increased the bond strength significantly (p < 0.05). When adhesives were applied to the acid etched dentin with ethanol-wet bonding, the bond strength was significantly higher than that of the no ethanol-wet bonding groups, and the incidence of cohesive failure was increased. Conclusions The effect of additional acid etching on the dentin bond strength was influenced by the pH of one-step self-etch adhesives. Ethanol wetting on etched dentin could create a stronger bonding performance of one-step self-etch adhesives for acid etched dentin.


Restorative Dentistry and Endodontics | 2015

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

Ji-Deok Moon; Eun-Mi Seon; Sung-Ae Son; Kyoung-Hwa Jung; Yong Hoon Kwon; Jeong-Kil Park

Objectives This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE L*a*b* color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (ΔE*) and the translucency parameter (TP) were calculated using the color coordinates. Results ΔE* ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ΔE* values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ΔE* change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.


Materials | 2017

Effect of Dentin Wetness on the Bond Strength of Universal Adhesives

An-Na Choi; Ji-Hye Lee; Sung-Ae Son; Kyoung-Hwa Jung; Yong Kwon; Jeong-Kil Park

The effects of dentin wetness on the bond strength and adhesive interface morphology of universal adhesives have been investigated using micro-tensile bond strength (μTBS) testing and confocal laser scanning microscopy (CLSM). Seventy-two human third molars were wet ground to expose flat dentin surfaces. They were divided into three groups according to the air-drying time of the dentin surfaces: 0 (without air drying), 5, and 10 s. The dentin surfaces were then treated with three universal adhesives: G-Premio Bond, Single Bond Universal, and All-Bond Universal in self-etch or etch-and-rinse mode. After composite build up, a μTBS test was performed. One additional tooth was prepared for each group by staining the adhesives with 0.01 wt % of Rhodamine B fluorescent dye for CLSM analysis. The data were analyzed statistically using ANOVA and Tukey’s post hoc tests (α = 0.05). Two-way ANOVA showed significant differences among the adhesive systems and dentin moisture conditions. An interaction effect was also observed (p < 0.05). One-way ANOVA showed that All-Bond Universal was the only material influenced by the wetness of the dentin surfaces. Wetness of the dentin surface is a factor influencing the micro-tensile bond strength of universal adhesives.


The Journal of Korean Academy of Conservative Dentistry | 2011

Influence of application methods of one-step self-etching adhesives on microtensile bond strength

Chul-Kyu Choi; Sung-Ae Son; Jin-hee Ha; Bock Hur; Hyeon-Cheol Kim; Yong-Hun Kwon; Jeong-Kil Park

Over the last decade, the classic concept of three-step bonding to dental tissues has developed rapidlyto more user-friendly, simplified adhesive systems.These comprise the two-step etch-and-rinse and theself-etching system. The use of self-etching systemeliminates the conditioning, rinsing and drying stepsthat have been shown to be both critical and difficultto standardize in operative conditions, because of theinstability of the demineralized dentin matrix.


The Journal of Korean Academy of Conservative Dentistry | 2004

The effect of multiple application on microtensile bond strength of all-in-one dentin adhesive systems

Sung-Ae Son; Bock Hur

The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturers recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p


Materials | 2018

Enamel Anti-Demineralization Effect of Orthodontic Adhesive Containing Bioactive Glass and Graphene Oxide: An In-Vitro Study

Seungmin Lee; Kyung-Hyeon Yoo; Seog-Young Yoon; In-Ryoung Kim; Bong-Soo Park; Woo-Sung Son; Ching-Chang Ko; Sung-Ae Son; Yong-Il Kim

White spot lesions (WSLs), a side effect of orthodontic treatment, can result in reversible and unaesthetic results. Graphene oxide (GO) with a bioactive glass (BAG) mixture (BAG@GO) was added to Low-Viscosity Transbond XT (LV) in a ratio of 1, 3, and 5%. The composite’s characterization and its physical and biological properties were verified with scanning electron microscopy (SEM) and X-ray diffraction (XRD); its microhardness, shear bond strength (SBS), cell viability, and adhesive remnant index (ARI) were also assessed. Efficiency in reducing WSL was evaluated using antibacterial activity of S. mutans. Anti-demineralization was analyzed using a cycle of the acid-base solution. Adhesives with 3 wt.% or 5 wt.% of BAG@GO showed significant increase in microhardness compared with LV. The sample and LV groups showed no significant differences in SBS or ARI. The cell viability test confirmed that none of the sample groups showed higher toxicity compared to the LV group. Antibacterial activity was higher in the 48-h group than in the 24 h group; the 48 h test showed that BAG@GO had a high antibacterial effect, which was more pronounced in 5 wt.% of BAG@GO. Anti-demineralization effect was higher in the BAG@GO-group than in the LV-group; the higher the BAG@GO concentration, the higher the anti-demineralization effect.

Collaboration


Dive into the Sung-Ae Son's collaboration.

Top Co-Authors

Avatar

Jeong-Kil Park

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Yong Hoon Kwon

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Bock Hur

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Kyoung-Hwa Jung

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Hyeon-Cheol Kim

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Eun-Mi Seon

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Hyung-Il Kim

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Yong-Il Kim

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Young Hoon Kwon

Pusan National University

View shared research outputs
Top Co-Authors

Avatar

Aromi Kang

Pusan National University

View shared research outputs
Researchain Logo
Decentralizing Knowledge