Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sunghoon Jeon is active.

Publication


Featured researches published by Sunghoon Jeon.


American Journal of Veterinary Research | 2014

Effect of region of interest and slice thickness on vertebral bone mineral density measured by use of quantitative computed tomography in dogs

Yeonho Bae; Seungjo Park; Sunghoon Jeon; Gahyun Lee; Jihye Choi

OBJECTIVE To determine the effect of region of interest (ROI) setting and slice thickness on trabecular bone mineral density (BMD) measured with quantitative CT in dogs. ANIMALS 14 healthy Beagles. PROCEDURES CT of the lumbar vertebrae and a quantitative CT phantom was performed. The BMD of trabecular bone was measured from L1 to L7 in 2 ways in all dogs. First, sequential 9.6-mm-thick CT images were acquired and then CT images were reconstructed into transverse CT images with slice thicknesses of 2.4, 4.8, and 9.6 mm. The obtained images were analyzed by circular ROI and trace ROI methods. Second, lumbar vertebrae were scanned with the installed quantitative CT protocol with a slice thickness of 10 mm and then the CT images were analyzed by installed automatic BMD software. RESULTS Interclass correlation coefficients of the automatic software (0.975 to 1.0) and the circular method (0.871 to 0.996) were high, compared with those of the trace method (0.582 to 0.996). The BMD measured with the automatic software was not significantly different from that measured with circular ROI and a slice thickness of 9.6 mm. The BMD measured by use of the circular method was not different according to slice thickness. CONCLUSIONS AND CLINICAL RELEVANCE Results obtained by use of automatic software were similar to those obtained by use of more manual methods. The CT images with thinner slice thickness (2.4 and 4.8 mm) could be used in dogs of toy and small breeds to measure lumbar vertebrae BMD to reduce the limitations of the standard 10-mm slice thickness.


Veterinary Radiology & Ultrasound | 2015

ULTRASONOGRAPHIC ELASTOGRAPHY OF THE LIVER, SPLEEN, KIDNEYS, AND PROSTATE IN CLINICALLY NORMAL BEAGLE DOGS

Sunghoon Jeon; Gahyun Lee; Sang-Kwon Lee; Hyunwoo Kim; Do-Hyeon Yu; Jihye Choi

Standard ultrasonography is often insensitive for distinguishing normal vs. diseased states for canine abdominal organs. Ultrasonographic elastography is a new technique that is becoming increasingly available and may help to improve sensitivity. This study evaluated the feasibility, repeatability, and reproducibility of strain elastography of the liver, spleen, kidneys, and prostate in healthy dogs and described the elasticity of each organ using strain values and strain ratios. The reproducibility of strain elastography was excellent, and intraobserver repeatability was moderate to excellent. The strain value of each organ was not significantly different among dogs (liver = 143.38 ± 7.41, spleen = 141.04 ± 9.03, left renal cortex = 141.26 ± 7.50, right renal cortex = 145.80 ± 7.79, and prostate = 135.46 ± 5.80), except for the renal medulla (left = 51.19 ± 4.54 and right = 51.93 ± 5.09) (P < 0.05). The strain ratios for the liver, spleen, renal cortex, and prostate were similar with no significant difference (liver = 10.20 ± 1.47, spleen = 8.40 ± 1.53, left renal cortex = 9.62 ± 1.56, right renal cortex = 8.29 ± 1.63, and prostate = 8.20 ± 1.21), except for the renal medulla (left = 3.48 ± 0.68 and right = 2.95 ± 0.63) (P < 0.05). Our results indicated that strain elastography was feasible for estimating tissue stiffness in the canine liver, spleen, kidneys, and prostate. This study provides basic information for strain values and strain ratios for the liver, spleen, kidneys, and prostate in clinically normal dogs.


Veterinary Radiology & Ultrasound | 2015

MEASUREMENTS OF THE PULMONARY VASCULATURE ON THORACIC RADIOGRAPHS IN HEALTHY DOGS COMPARED TO DOGS WITH MITRAL REGURGITATION

Heejin Oui; Juyeon Oh; Seoyeon Keh; Gahyun Lee; Sunghoon Jeon; Hyunwook Kim; Junghee Yoon; Jihye Choi

This study reassessed the previously reported radiographic method of comparing pulmonary vessels versus rib diameter for differentiating healthy dogs and dogs with mitral regurgitation. The width of the right cranial pulmonary artery and vein at the fourth rib level, right caudal pulmonary artery and vein at the ninth rib level, and the diameters of the fourth rib and ninth rib were measured in prospectively recruited healthy dogs (n = 40) and retrospectively recruited dogs with mitral regurgitation (n = 58). In healthy dogs, the pulmonary arteries and accompanying veins were similar in size. The cranial lobar vessels were smaller than the fourth rib. However, 67.5% of right caudal pulmonary artery diameters and 65% of vein diameters were larger than the ninth rib in healthy dogs. The right caudal pulmonary vein diameter in dogs with mitral regurgitation, particularly those within moderate and severe grades, was significantly larger than that in healthy dogs (P < 0.001). The comparative method used to detect enlargement of the right caudal pulmonary vein relative to the accompanying pulmonary artery had the highest sensitivity (80.2%) and specificity (82.5%) for predicting mitral regurgitation. A cut-off of 1.22 when applying the ninth rib criterion had better specificity (73%) than the most used value ≤ 1 (89.7% sensitivity and 63.8% specificity), although it has less sensitivity (73%). We recommend using the accompanying pulmonary artery and 1.22 × the diameter of the ninth rib as a radiographic criterion for assessing the size of the right caudal pulmonary vein and differentiating healthy dogs from those with mitral regurgitation.


Journal of Small Animal Practice | 2014

Congenital lymphangiomatosis and an enteric duplication cyst in a young dog.

Heejin Oui; Catherine G. Lamm; Shane Stiver; Bruce Williams; Seong Young Kwon; Yeonho Bae; Sunghoon Jeon; Seungjo Park; Jung-Joon Min; Jihye Choi

A two-year-old female poodle with abdominal distention was diagnosed with concurrent enteric duplication cyst and lymphangiomatosis. Both lesions were shown as cystic structures, but some characteristic features of enteric duplication cyst were identified including a thick cyst wall and shared blood supply with the duodenum. Although it was challenging to discriminate between the types of cyst based on diagnostic imaging, this report describes the characteristics of each type of lesion using several different imaging modalities.


Veterinary Radiology & Ultrasound | 2015

STRAIN ELASTOGRAPHY USING DOBUTAMINE‐INDUCED CAROTID ARTERY PULSATION IN CANINE THYROID GLAND

Gahyun Lee; Sunghoon Jeon; Sang-Kwon Lee; Hyunwoo Kim; Do-Hyeon Yu; Jihye Choi

Thyroid disease is common in dogs and conventional ultrasonography is a standard diagnostic test for diagnosis and treatment planning. Strain elastography can provide additional information about tissue stiffness noninvasively after applying external or internal compression. However, natural carotid artery pulsations in the canine thyroid gland are too weak to maintain sufficient internal compression force. The objective of the present study was to describe the feasibility of strain elastography for evaluating the canine thyroid gland and the repeatability of dobutamine-induced carotid artery pulsation as an internal compression method. In seven healthy Beagle dogs, strain on each thyroid lobe was induced by external compression using the ultrasound probe and internal compression using carotid artery pulsation after dobutamine infusion. The thyroid appeared homogeneously green and the subcutaneous fat superficial to the thyroid lobe appeared blue. Strain values and strain ratios did not differ among dogs or between the left and right lobes. Interobserver repeatability was excellent for both compression methods. Intraobserver repeatability of the strain ratio measured using the carotid artery pulsation method (intraclass coefficient correlation = 0.933) was higher than that measured using the external compression method (0.760). Mean strain values of thyroid lobes for the external compression method (142.93 ± 6.67) differed from the internal method (147.31 ± 8.24; P < 0.05). Strain ratios between the two methods did not differ. Strain elastography was feasible for estimating thyroid stiffness in dogs. Carotid artery pulsation induced by dobutamine infusion can be used for canine thyroid strain elastography with excellent repeatability.


Journal of Veterinary Medical Science | 2014

Ultrasound, CT and FDG PET-CT of a duodenal granuloma in a dog.

Sunghoon Jeon; Seong Young Kwon; Rohani Cena; Ju-Hwan Lee; Kyoung-Oh Cho; Jung-Joon Min; Jihye Choi

ABSTRACT A 12-year-old spayed female Yorkshire Terrier with intermittent vomiting was diagnosed with regional granulomatous enteritis through histopathological examination. On ultrasonography and computed tomography, a focal thickened duodenal wall showed a mass-like appearance with indistinct wall layers. Marked uptake of 18F-fluorodeoxyglucose was observed from the mass on positron emission tomography-computed tomography. Regional granulomatous enteritis is a rare form of inflammatory bowel disease and may have imaging features similar to intestinal tumors. This is the first study describing the diagnostic imaging features of ultrasonography, computed tomography and positron emission tomography-computed tomography for regional granulomatous enteritis in a dog.


Journal of Veterinary Medical Science | 2015

Contrast-enhanced ultrasonography to assess blood perfusion of skeletal muscles in normal dogs.

Juyeon Oh; Sunghoon Jeon; Jihye Choi

This study evaluated perfusion of skeletal muscle using contrast enhanced ultrasonography in humerus, radius, femur and tibia in normal dogs. Contrast enhanced ultrasonography for each region was performed after injecting 0.5 mL and 1 mL of contrast medium (SonoVue) in every dog. Blood perfusion was assessed quantitatively by measuring the peak intensity, time to the peak intensity and area under the curve from the time–intensity curve. Vascularization in skeletal muscle was qualitatively graded with a score of 0–3 according to the number of vascular signals. A parabolic shape of time–intensity curve was observed from muscles in normal dogs, and time to the peak intensity, the peak intensity and area under the curve of each muscle were not significantly different according to the appendicular regions examined and the dosage of contrast agent administered. This study reports that feasibility of contrast enhanced ultrasonography for assessment of the muscular perfusion in canine appendicular regions.


American Journal of Veterinary Research | 2015

Dynamic computed tomographic determination of scan delay for use in performing cardiac angiography in clinically normal dogs

Jisun Kim; Yeonho Bae; Gahyun Lee; Sunghoon Jeon; Jihye Choi

OBJECTIVE To determine the scan delay for use in performing cardiac CT angiography in dogs. ANIMALS 4 clinically normal adult Beagles. PROCEDURES In a crossover study, 12 formulations of iohexol solutions differing in iodine dose (300, 400, and 800 mg/kg) and concentration (undiluted and diluted 1:1, 1:2, and 1:3 with saline [0.9% NaCl] solution) were administered IV to each dog. Dynamic CT angiography was performed to evaluate enhancement characteristics of each formulation, with the region of interest set over the aorta. Time-attenuation curves (TACs) were obtained and analyzed. RESULTS Peak arc-type TACs were obtained after administration of all undiluted formulations. Curve shape changed from peak arc type to plateau type as the total volume of the contrast solution (ie, dilution) increased. Prolonged peaks characteristic of plateau-type TACs suggested that a sufficient period of homogeneous attenuation could be achieved for CT scanning with administration of higher iohexol dilutions (1:2 or 1:3) containing higher iodine doses (400 or 800 mg/kg). In particular, attenuation values for plateau-type TACs remained between 200 and 300 Hounsfield units for > 16 seconds after the plateau endpoint was reached for 1:2 and 1:3 dilutions containing an iodine dose of 800 mg/kg. Scan delays of 13 to 17 seconds were computed for those 2 formulations. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that for clinically normal dogs, a scan delay of 13 to 17 seconds could be used to perform cardiac CT angiography with iohexol solutions containing an iodine dose of 800 mg/kg at dilutions of 1:2 or 1:3.


Journal of Veterinary Medical Science | 2013

Computed Tomography Angiography of Situs Inversus, Portosystemic Shunt and Multiple Vena Cava Anomalies in a Dog

Heejin Oui; Jisun Kim; Yeonho Bae; Juyeon Oh; Seungjo Park; Gahyun Lee; Sunghoon Jeon; Jihye Choi

ABSTRACT A 5-year-old Shih Tzu was presented with intermittent vomiting and anorexia. Microhepatica and reversed position of the abdominal organs were observed on radiography. Ultrasonographically, portosystemic shunt (PSS) was tentatively diagnosed. Computed tomography (CT) revealed that the distended portal vein drained into the left hepatic vein. The caudal vena cava (CdVC) split postrenally and converged at the renal level. Cranial to this, the azygos continuation of the CdVC was confirmed. In the thorax, a persistent left cranial vena cava (CrVC) was found along with right CrVC. This is the first report of a dog with persistent left CrVC and multiple abdominal malformations. CT angiography was useful in evaluating the characteristics of each vascular anomaly and determining the required surgical correction in this complex case.


Journal of Veterinary Science | 2017

Quantitative evaluation of renal parenchymal perfusion using contrast-enhanced ultrasonography in renal ischemia-reperfusion injury in dogs

Gahyun Lee; Sunghoon Jeon; Sang-Kwon Lee; Byunggyu Cheon; Sohyeon Moon; Jun-Gyu Park; Kyoung-Oh Cho; Jihye Choi

This study evaluated whether renal perfusion changes can be noninvasively estimated by using contrast-enhanced ultrasonography (CEUS) in renal ischemia-reperfusion injury and investigated the correlation between renal perfusion measured by CEUS and necrosis and apoptosis of renal tubular epithelial cells. In six dogs with experimentally induced renal ischemia-reperfusion injury, changes in time to peak intensity, peak intensity, and area under the curve were measured on CEUS. Peak intensity and area under the curve of the renal cortex began to decrease on day 1 (about 20% lower than baseline) and reached the lowest levels (about 50% of baseline) on day 4. They then gradually increased until day 10, at which time peak intensity was about 87% and area under the curve was about 95% of baseline; neither fully recovered. Both parameters were strongly correlated with the necrosis scores on histopathologic examination on day 4 (r = −0.810 of peak intensity and r = −0.886 of area under the curve). CEUS allowed quantitative evaluation of perfusion changes in acute renal ischemia-reperfusion injury, and CEUS results were correlated with renal tubular damage on histopathologic examination. Thus, CEUS could be a noninvasive, quantitative diagnostic method for determining progress of renal ischemia-reperfusion injury.

Collaboration


Dive into the Sunghoon Jeon's collaboration.

Top Co-Authors

Avatar

Jihye Choi

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Gahyun Lee

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Seungjo Park

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Yeonho Bae

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Kyoung-Oh Cho

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Heejin Oui

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Juyeon Oh

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Sang-Kwon Lee

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Do-Hyeon Yu

Chonnam National University

View shared research outputs
Top Co-Authors

Avatar

Hyunwook Kim

Seoul National University

View shared research outputs
Researchain Logo
Decentralizing Knowledge