Radiology | 1973

Increased Rate of Complications as a Result of Treating Only One Prescribed Field Daily

Richard D. Marks; Suresh K. Agarwal; William C. Constable

The technique of treating only one prescribed field daily in a multi-field setup produces an increased biological effect upon the normal tissues. In a consecutive group of 18 patients with Hodgkins disease all treated employing extended opposed fields on a 60Co unit and treating only one prescribed field daily, 8 patients have delayed complications attributable to radiotherapy. All 18 have been followed for more than four years. The concept of Nominal Standard Dose (NSD) has been utilized in this study to compare the dosages in critical areas, i.e., the heart and spinal cord, relative to the tumor dose. Tolerance was exceeded to a greater extent in the patients with complications.


Stereotactic and Functional Neurosurgery | 1991

Quality Assurance of Leksell Gamma Units

Harold W. Berk; Suresh K. Agarwal

A Leksell Gamma Unit was commissioned and a Lars Leksell Center for Radiosurgery was established at the University of Virginia Health Sciences Center in March 1989. At that time a formal quality assurance program designed for the Leksell Gamma Unit was put into effect. This paper will review the components of suggested daily, monthly, semiannual and annual quality assurance reviews of United States Nuclear Regulatory Commission regulatory as well as nonregulatory items for Leksell Gamma Units. The acceptance criterion for each quality assurance test has been established based on federal requirements and the recommendations of national scientific organizations as well as the practical experience gained from this quality assurance program.


Radiology | 1978

The effectiveness of glass lenses in reducing exposure to the eyes.

Suresh K. Agarwal; Elroy J. Friesen; Alan L. Huddleston; Ravindra P. Rao

A study was done to determine the degree of radiation protection afforded by various types of prescription lenses, including commercially available lead glasses. A wide variation in measured attenuation was found. Two commonly available types of prescription lenses were found to provide greater than 92% attenuation of the x-ray beam generated at 108 kVp.


Stereotactic and Functional Neurosurgery | 1993

Extracranial absorbed doses with Gamma Knife radiosurgery.

Harold W. Berk; J.M. Larner; C. Spaulding; Suresh K. Agarwal; M.R. Scott; Ladislau Steiner

Radiosurgery is used with increasing frequency, not only for the treatment of cerebral arteriovenous malformations (AVMs), but also for the treatment of other well-defined lesions including acoustic neuromas, meningiomas, pituitary adenomas as well as solitary metastases. Although investigators have addressed dosimetric aspects of stereotactic radiosurgery in terms of target volume, little if any attention has been focused on the absorbed doses received at extracranial sites. Therefore, absorbed doses to the eye, thyroid, sternum and gonads were measured in 111 patients (100 adults and 11 children) using thermoluminescent dosimetry (TLDs). For the 100 adults, the average maximum target absorbed dose was 35 +/- 8 Gy. The measured absorbed dose in selected organs of adults from Gamma Knife radiosurgery using one or more isocenters was 9 +/- 8 cGy for the eye, 15 +/- 7 cGy for the thyroid, 20 +/- 10 cGy for the sternum and 3 +/- 2 cGy for the gonads. The absorbed doses received by the children (13 years and younger) was similar with the exception of a marked increase in gonadal dose. The use of multiple isocenters is associated with higher absorbed doses to extracranial sites.


International Journal of Radiation Oncology Biology Physics | 1979

A MISSING TISSUE COMPENSATOR

Gene R. Feaster; Suresh K. Agarwal; Alan L. Huddleston; Elroy J. Friesen

Abstract A method is described for the fabrication of missing tissue compensators used in radiation therapy. This method uses layers of styrofoam plastic and a hot-wire cutting machine to construct a mold in which the compensator is made from tissue equivalent material. When the patient contours are provided, no special equipment or materials are required beyond those normally found in a therapy clinic.


Stereotactic and Functional Neurosurgery | 1993

The Dosimetric Consequences of Weighted Fields Using the Same Isocenter in Radiosurgery

J.M. Larner; Harold W. Berk; Suresh K. Agarwal; Ladislau Steiner

One handicap in achieving ideal dosimetry with the Gamma Knife is the limited number of standard collimator sizes (4, 8, 14 and 18 mm). We report an approach that makes possible the creation of 50% or higher isodose lines, corresponding to collimator sizes from 4 to 18 mm. This technique, which uses the same icocenter, but with different sized and weighted collimators, improves matching for given isodose lines to the diameter of the lesion in a defined plane. However, when combination fields, designed to reproduce the 50% isodose diameter of the 8- and 14-mm collimators, are compared to the standard sizes, there are significant differences in the three-dimensional dosimetry.


Medical Physics | 1983

An overview of errors in line source dosimetry for gamma-ray brachytherapy

Subramania Jayaraman; Lawrence H. Lanzl; Suresh K. Agarwal

The generally used approach for routine brachytherapy dosimetry depends on a value of source strength provided by the source supplier, the theoretical concept of exposure rate constants for different nuclides, and the applicability of inverse square law to point sources. Corrections for filtration of the radiation within the capsule of the source and attenuation in tissue medium are effected based on attenuation coefficients and data published in the literature. Therefore there is no unique or ideal way of selecting the required data and there could be a spread in the dose values derived by different users. The errors inherent in the current practice of dosimetry of linear sources in brachytherapy are discussed. If the brachytherapy sources are specified in terms of exposure rate at a distance from the source by the source suppliers, the overall uncertainty in the dosimetry at regions of clinical interest around the source could be limited to about +/- 6%.


International Journal of Radiation Oncology Biology Physics | 1977

A method of dosimetry for irregularly shaped fields

Suresh K. Agarwal; Jack Wakley; Ronald V. Scheele; Ann Normansell

Abstract The calculation of an effective equivalent square treatment area for an irregularly shaped field, using the table of equivalent squares from B.J.R. Supplement 11 3 is explained. Depth doses obtained using this calculated area are compared with experimentally measured values; the results obtained indicate that the method, which is simple enough to be used by technologists, is sufficiently accurate for routine use in treatment planning.


Medical Physics | 1979

Dose distribution from a Delta-25 head scanner.

Suresh K. Agarwal; E. J. Friesen; D. Bhaduri; G. Courlas

The dose distribution pattern from a Delta-25 head scanner was evaluated experimentally in a 17.5-cm-diam cylinder water phantom for different scan speed and slice thickness combinations. TLD chips were used to measure the dose at different points across the scan section. The isodose curves thus obtained were found to be asymmetric, with the regions of maximum and minimum dose near the surface on the opposite sides of the phantom. The effect of changing the scan thickness and speed on dose was evaluated and a linear increase in dose with the increase of slice thickness was observed. This was consistent with the design of the line focus and the beam collimators used in this system. The effect of multiple slice scan on the dose was also evaluated.


Medical Physics | 1981

Influence of surface shape on tissue–air ratio for cobalt‐60

S. Jayaraman; Suresh K. Agarwal; D. Bhaduri

The shape of the surface of incidence could affect the scatter and change the effective tissue-air ratio (TAR) value. The curvature of the body is considerable within the large beams used for total body irradiation. The effect of the surface curvature on the effective TAR value was studied using a computational approach that sums up the differential scatter air ratios from elemental beams. It was observed that the difference between the effective TAR and the standard flat surface TAR increased with depth to reach a maximum value of about 2% around 8--11 cm depth. It decreased for larger depths, and the effect of surface shape was not perceivable beyond 18 cm depth.

Collaboration


Dive into the Suresh K. Agarwal's collaboration.

Top Co-Authors

Avatar

Jack Wakley

University of Virginia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

D. Bhaduri

University of Virginia

View shared research outputs
Top Co-Authors

Avatar

J.M. Larner

University of Virginia

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge