Susanne Kheddache
Sahlgrenska University Hospital
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Susanne Kheddache.
Radiology | 2008
Jenny Vikgren; Sara Zachrisson; Angelica Svalkvist; Åse Allansdotter Johnsson; Marianne Boijsen; Agneta Flinck; Susanne Kheddache; Magnus Båth
PURPOSE To compare chest tomosynthesis with chest radiography in the detection of pulmonary nodules by using multidetector computed tomography (CT) as the reference method. MATERIALS AND METHODS The Regional Ethical Review Board approved this study, and all participants gave informed consent. Four thoracic radiologists acted as observers in a jackknife free-response receiver operating characteristic (JAFROC) study conducted in 42 patients with and 47 patients without pulmonary nodules examined with chest tomosynthesis and chest radiography. Multidetector CT served as reference method. The observers marked suspected nodules on the images by using a four-point rating scale for the confidence of presence. The JAFROC figure of merit was used as the measure of detectability. The number of lesion localizations relative to the total number of lesions (lesion localization fraction [LLF]) and the number of nonlesion localizations relative to the total number of cases (nonlesion localization fraction [NLF]) were determined. RESULTS Performance of chest tomosynthesis was significantly better than that of chest radiography with regard to detectability (F statistic = 32.7, df = 1, 34.8, P < .0001). For tomosynthesis, the LLF for the smallest nodules (< or = 4 mm) was 0.39 and increased with an increase in size to an LLF for the largest nodules (> 8 mm) of 0.83. The LLF for radiography was small, except for the largest nodules, for which it was 0.52. In total, the LLF was three times higher for tomosynthesis. The NLF was approximately 50% higher for tomosynthesis. CONCLUSION For the detection of pulmonary nodules, the performance of chest tomosynthesis is better, with increased sensitivity especially for nodules smaller than 9 mm, than that of chest radiography.
European Radiology | 2004
Patrik Sund; Magnus Båth; Susanne Kheddache; Lars Gunnar Månsson
A study was conducted to compare physical and clinical system performance in digital chest radiography. Four digital X-ray modalities, two storage-phosphor based systems and two generations of a CCD-based system, were evaluated in terms of both their imaging properties (determination of presampling MTF and DQE) and clinical image quality (grading of the reproduction of anatomical details of 23 healthy volunteers using both absolute and relative visual grading analysis). One of the two storage-phosphor systems performed best in both evaluations and the first generation of the CCD-based system was rated worst; however, the other two systems were ranked differently with the two methods. The newest CCD-based system yielded a higher clinical image quality than the second storage-phosphor system, although the latter presented a DQE substantially higher than the former. The results show that clinical performance cannot be predicted from determinations of DQE alone, and that a system with lower DQE, under the quantum-saturated conditions in chest radiography, can outperform a system with higher DQE if the image processing used on the former is more effective in presenting the information in the image to the radiologist.
Acta Radiologica | 2009
Sara Zachrisson; Jenny Vikgren; Angelica Svalkvist; Åse Allansdotter Johnsson; Marianne Boijsen; Agneta Flinck; Lars Gunnar Månsson; Susanne Kheddache; Magnus Båth
Background: The new technique chest tomosynthesis refers to the principle of collecting low-dose projections of the chest at different angles and using these projections to reconstruct section images of the chest at a radiation dose comparable to that of chest radiography. Purpose: To investigate if, for experienced thoracic radiologists, the detectability of pulmonary nodules obtained after only a short initial learning period of chest tomosynthesis improves with additional clinical experience of the new technique. Material and Methods: Two readings of the same clinical chest tomosynthesis cases, the first performed after 6 months of clinical experience and the second after an additional period of 1 year, were conducted. Three senior thoracic radiologists, with more than 20 years of experience of chest radiography, acted as observers, with the task of detecting pulmonary nodules in a jackknife free-response receiver operating characteristics (JAFROC1) study. The image material consisted of 42 patients with and 47 patients without pulmonary nodules examined with chest tomosynthesis. Multidetector computed tomography (MDCT) was used as a reference. The total number of nodules was 131. The JAFROC1 figure of merit (FOM) was used as the principal measure of detectability. Results: The difference in the observer-averaged JAFROC1 FOM of the two readings was 0.004 (95% confidence interval: -0.11, 0.12; F-statistic: 0.01 on 1 and 2.65 df; P=0.91). Thus, no significant improvement in detectability was found after the additional clinical experience of tomosynthesis. Conclusion: The study indicates that experienced thoracic radiologists already within the first months of clinical use of chest tomosynthesis are able to take advantage of the new technique in the task of detecting pulmonary nodules.
Medical Imaging 2000: Image Perception and Performance | 2000
Patrik Sund; Clemens Herrmann; Anders Tingberg; Susanne Kheddache; Lars Gunnar Månsson; A Almen; Sören Mattsson
The Imix radiography system (Oy Imix Ab, Finland) consists of an intensifying screen, optics, and a CCD camera. An upgrade of this system (Imix 2000) with a red-emitting screen and new optics has recently been released. The image quality of Imix (original version), Imix 2000, and two storage-phosphor systems, Fuji FCR 9501 and Agfa ADC70 was evaluated in physical terms (DQE) and with visual grading of the visibility of anatomical structures in clinical images (141 kV). PA chest images of 50 healthy volunteers were evaluated by experienced radiologists. All images were evaluated on Siemens Simomed monitors, using the European Quality Criteria. The maximum DQE values for Imix, Imix 2000 Agfa and Fuji were 11%, 14%, 17% and 19%, respectively (141 kV, 5 (mu) Gy). Using the visual grading, the observers rated the systems in the following descending order: Fuji, Imix 2000, Agfa, and Imix. Thus, the upgrade to Imix 2000 resulted in higher DQE values and a significant improvement in clinical image quality. The visual grading agrees reasonably well with the DQE results; however, Imix 2000 received a better score than what could be expected from the DQE measurements.
Radiation Protection Dosimetry | 2010
Åse Allansdotter Johnsson; Jenny Vikgren; Angelica Svalkvist; Sara Zachrisson; Agneta Flinck; Marianne Boijsen; Susanne Kheddache; Lars Gunnar Månsson; Magnus Båth
Since December 2006, approximately 3800 clinical chest tomosynthesis examinations have been performed at our department at Sahlgrenska University Hospital. A subset of the examinations has been included in studies of the detectability of pulmonary nodules, using computed tomography (CT) as the gold standard. Visibility studies, in which chest tomosynthesis and CT have been compared side-by side, have been used to determine the depiction potential of chest tomosynthesis. Comparisons with conventional chest radiography have been made. In the clinical setting, chest tomosynthesis has mostly been used as an additional examination. The most frequent indication for chest tomosynthesis has been suspicion of a nodule or tumour. In visibility studies, tomosynthesis has depicted over 90 % of the nodules seen on the CT scan. The corresponding figure for chest radiography has been <30 %. In the detection studies, the lesion-level sensitivity has been approximately 60 % for tomosynthesis and 20 % for chest radiography. In one of the detection studies, an analysis of all false-positive nodules was performed. This analysis showed that all findings had morphological correlates on the CT examinations. The majority of the false-positive nodules were localised in the immediate subpleural region. In conclusion, chest tomosynthesis is an improved chest radiography method, which can be used to optimise the use of CT resources, thereby reducing the radiation dose to the patient population. However, there are some limitations with chest tomosynthesis. For example, patients undergoing tomosynthesis have to be able to stand still and hold their breath firmly for 10 s. Also, chest tomosynthesis has a limited depth resolution, which may explain why pathology in the subpleural region is more difficult to interpret and artefacts from medical devices may occur.
Acta Radiologica | 2011
Sara Asplund; Åse Allansdotter Johnsson; Jenny Vikgren; Angelica Svalkvist; Marianne Boijsen; Valeria Fisichella; Agneta Flinck; Åsa Wiksell; Jonas Ivarsson; Hans Rystedt; Lars Gunnar Månsson; Susanne Kheddache; Magnus Båth
Background In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. Purpose To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. Material and Methods Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. Results Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and subpleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. Conclusion The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution.
European Journal of Radiology | 1991
Susanne Kheddache; Lars Gunnar Månsson; Jan Erik Angelhed; Lisbeth Denbratt; B Gottfridsson; D. Schlossman
A digital system for chest radiography based on a large image intensifier was compared to a conventional film-screen system. The digital system was optimized with regard to spatial and contrast resolution and dose. The images were digitally processed for contrast and edge enhancement. A simulated pneumothorax and two simulated nodules were positioned over the lungs and the mediastinum of an anthropomorphic phantom. Observer performance was evaluated with ROC analysis. Five observers assessed the processed digital images and the conventional full-size radiographs. The time spent viewing the full-size radiographs and the digital images was recorded. For the simulated pneumothorax, the results showed perfect performance for the full-size radiographs and detectability was high also for the processed digital images. No significant difference in the detectability of the simulated nodules was seen between the two imaging systems. The results for the digital images showed a significantly improved detectability for the nodules in the mediastinum as compared to a previous ROC study where no optimization and image processing was available. No significant difference in detectability was seen between the former and the present ROC study for small nodules in the lung. No difference was seen in the time spent assessing the conventional full-size radiographs and the digital images. The study indicates that processed digital images produced by a large image intensifier are equal in image quality to conventional full-size radiographs for low-contrast objects such as nodules.
Radiation Protection Dosimetry | 2010
Åse Allansdotter Johnsson; Angelica Svalkvist; Jenny Vikgren; Marianne Boijsen; Agneta Flinck; Susanne Kheddache; Magnus Båth
The aim of the present study was to investigate nodule size measurements with chest tomosynthesis (TS) and computed tomography (CT). A 26-mm thick phantom, composed of a Polylite block with embedded spheres of different materials and sizes (4-20 mm), was scanned by both CT and TS. Six observers without prior knowledge of the true diameters of the spheres independently measured the diameter of the spheres on the CT and TS images. Four observers were allowed to change the window settings and two of the observers used predetermined fixed viewing conditions. The mean relative errors for all observers and all measured spheres compared with the known diameter of the spheres were 1.4 % (standard deviation, SD: 5.4 %) on CT images and -1.1 % (SD: 5.0 %) on TS images. With regard to the four observers where the window settings were at the discretion of the observer, the mean relative errors were 1.4 % (SD: 6.4 %) on CT images and -1.7 % (SD: 5.7 %) on TS images. Regarding the two observers using identical viewing conditions the mean relative error was 1.5 % (SD: 2.8 %) on CT images and 0.2 % (SD: 2.6 %) on TS images. In conclusion, the study suggests that nodule size measurements on chest TS might be an alternative to measurements on CT.
European Radiology | 1999
Susanne Kheddache; A. Thilander-Klang; B. Lanhede; Lars Gunnar Månsson; N. Bjurstam; P. Ackerholm; L. Björneld
Abstract. The aim of this study was to compare the image quality of storage phosphor plates with that in screen-film radiograms in mammography. Two anode/filter combinations were also compared – Mo/Mo and W/Rh. S Storage phosphor plates, generation IIIN (Fuji, Tokyo, Japan) and a conventional screen-film system (Kodak, Rochester, N. Y.) were evaluated using two mammographic units. One unit had a 0.6-mm focal spot, an anode/filter combination of Mo/Mo and no grid (AMo); the other had a 0.3-mm focal spot, a grid, and two possible combinations of anode/filter Mo/Mo (BMo) and W/Rh (BW). Simulated tumours and microcalcifications were randomly positioned in an anthropomorphic breast phantom (RMI model 165, no. 210–009, Radiation Measurements Inc., Middleton, Wisconsin). The image quality was evaluated using a modified version of receiver operating characteristics analysis. Five observers evaluated 300 films and 300 hard copy images each. Radiation doses were also determined. The image quality of the conventional screen-film images was significantly better than that for the storage phosphor plate mammograms. The BMo system rated best, for the detection of both tumours and microcalcifications, although it was not significantly different from the BW system. Systems BMo and BW rated significantly better than the AMo system for both image receptors studied. The mean absorbed dose was twice as high for the BMo system as for the AMo and BW systems for both conventional and digital technique. The mammograms produced with the screen-film combination gave a significantly better detectability than the storage phosphor plates used in this study. Substantial dose reduction could be achieved using an anode/filter combination of W/Rh instead of Mo/Mo with no significant loss of information in the images.
European Radiology | 1999
Lars Gunnar Månsson; Susanne Kheddache; B. Lanhede; U. Tylén
Abstract. The purpose of the study was to compare the image quality for one conventional and four digital chest radiography techniques. Three storage phosphor systems, one selenium drum system, and one film-screen system were compared using a modified receiver-operating-characteristics method. Simulated pathology was randomly positioned over the parenchymal regions and the mediastinum of an anthropomorphic phantom. Eight observers (four chest radiologists, one specialist in general radiology, one hospital physicist, and two radiographers) evaluated 60 images for each technique. The selenium drum system (Philips, Eindhoven, The Netherlands) rated best for the detection of parenchymal nodules. Together with the storage phosphor system of generation IIIN (Philips/Fuji), the selenium drum system also rated best for detection of thin linear structures. The storage phosphor system of generation V (Fuji) rated best for the detection of mediastinal nodules. The first generation of the storage phosphor system from Agfa (Mortsel, Belgium) rated worst for the detection of parenchymal nodules and thin linear structures. These differences were significant (p < 0.0001). Averaging the results for all test objects, the selenium drum system and the storage phosphor system of generation V were significantly better than the other systems tested. The film/screen system performed significantly better than the first-generation storage phosphor system from Agfa, equal to the generation IIIN storage phosphor system (Philips/Fuji) and significantly worse than the selenium drum system (Philips) and the generation-V storage phosphor system (Fuji). The conclusion is therefore that the image quality of selenium-based digital technique and of the more recent generations of storage phosphor systems is superior to both conventional technique and storage phosphor systems using image plates of older types.