Susanne Nahles
Charité
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Susanne Nahles.
American Journal of Orthodontics and Dentofacial Orthopedics | 2013
Tabea Flügge; Stefan Schlager; Katja Nelson; Susanne Nahles; Marc C. Metzger
INTRODUCTION Digital impression devices are used alternatively to conventional impression techniques and materials. The aims of this study were to evaluate the precision of digital intraoral scanning under clinical conditions (iTero; Align Technologies, San Jose, Calif) and to compare it with the precision of extraoral digitization. METHODS One patient received 10 full-arch intraoral scans with the iTero and conventional impressions with a polyether impression material (Impregum Penta; 3M ESPE, Seefeld, Germany). Stone cast models manufactured from the impressions were digitized 10 times with an extraoral scanner (D250; 3Shape, Copenhagen, Denmark) and 10 times with the iTero. Virtual models provided by each method were roughly aligned, and the model edges were trimmed with cutting planes to create common borders (Rapidform XOR; Inus Technologies, Seoul, Korea). A second model alignment was then performed along the closest distances of the surfaces (Artec Studio software; Artec Group, Luxembourg, Luxembourg). To assess precision, deviations between corresponding models were compared. Repeated intraoral scanning was evaluated in group 1, repeated extraoral model scanning with the iTero was assessed in group 2, and repeated model scanning with the D250 was assessed in group 3. Deviations between models were measured and expressed as maximums, means, medians, and root mean square errors for quantitative analysis. Color-coded displays of the deviations allowed qualitative visualization of the deviations. RESULTS The greatest deviations and therefore the lowest precision were in group 1, with mean deviations of 50 μm, median deviations of 37 μm, and root mean square errors of 73 μm. Group 2 showed a higher precision, with mean deviations of 25 μm, median deviations of 18 μm, and root mean square errors of 51 μm. Scanning with the D250 had the highest precision, with mean deviations of 10 μm, median deviations of 5 μm, and root mean square errors of 20 μm. Intraoral and extraoral scanning with the iTero resulted in deviations at the facial surfaces of the anterior teeth and the buccal molar surfaces. CONCLUSIONS Scanning with the iTero is less accurate than scanning with the D250. Intraoral scanning with the iTero is less accurate than model scanning with the iTero, suggesting that the intraoral conditions (saliva, limited spacing) contribute to the inaccuracy of a scan. For treatment planning and manufacturing of tooth-supported appliances, virtual models created with the iTero can be used. An extended scanning protocol could improve the scanning results in some regions.
Clinical Oral Implants Research | 2016
Tobias Fretwurst; Guenter Buzanich; Susanne Nahles; Johan Peter Woelber; Heinrich Riesemeier; Katja Nelson
OBJECTIVES Dental peri-implantitis is characterized by a multifactorial etiology. The role of metal elements as an etiological factor for peri-implantitis is still unclear. The aim of this study was to investigate the incidence of metal elements in bone and mucosal tissues around dental Grade 4 CP titanium implants with signs of peri-implantitis in human patients. METHODS In this prospective pilot study, all patients were enrolled consecutively in two study centers. Bone and soft tissue samples of patients with peri-implantitis with indication for explantation were analyzed for the incidence of different elements (Ca, P, Ti, Fe) by means of synchrotron radiation X-ray fluorescence spectroscopy (SRXRF) and polarized light microscopy (PLM). The existence of macrophages and lymphocytes in the histologic specimens was analyzed. RESULTS Biopsies of 12 patients (seven bone samples, five mucosal samples) were included and analyzed. In nine of the 12 samples (75%), the SRXRF examination revealed the existence of titanium (Ti) and an associated occurrence with Iron (Fe). Metal particles were detected in peri-implant soft tissue using PLM. In samples with increased titanium concentration, lymphocytes were detected, whereas M1 macrophages were predominantly seen in samples with metal particles. CONCLUSION Titanium and Iron elements were found in soft and hard tissue biopsies retrieved from peri-implantitis sites. Further histologic and immunohistochemical studies need to clarify which specific immune reaction metal elements/particles induce in dental peri-implant tissue.
Oral Surgery, Oral Medicine, Oral Pathology, and Oral Radiology | 2016
Jan-Dirk Raguse; Jaber Hossamo; Ingeborg Tinhofer; Bodo Hoffmeister; Volker Budach; Basil Jamil; Korinna Jöhrens; Nadine Thieme; Christian Doll; Susanne Nahles; Stefan Hartwig; Carmen Stromberger
OBJECTIVE The purpose of this study was to evaluate risk factors for and the incidence of osteoradionecrosis (ORN) of the jaw in patients with head and neck cancer. STUDY DESIGN This study was a retrospective analysis of the risk for ORN and outcome for 149 of 540 patients with head and neck cancer of the oral cavity (65%), oropharynx (26%), or other head and neck sites (9%) treated with radiotherapy between 2004 and 2009. ORN was graded according to Late Effects of Normal Tissues/Somatic Objective Management Analytic Scale (LENT/SOMA) criteria. RESULTS Within a median follow-up of 41 months (95% confidence interval: 27.4-54.6), 38 patients (25.5%) had developed ORN, 37 patients (25%) had a local recurrence, and 53 patients (36%) had died. The median time to diagnosis of ORN was 14.5 months (range: 3-80), and 79% were diagnosed within 2 years of RT. Eleven of these patients had undergone previous mandibular surgery. Univariate significant risk factors for ORN were any comorbidity, poor oral hygiene, pre-radiotherapy osteotomy, close tumor-to-bone proximity, post-radiotherapy dentoalveolar surgery (DAS), DAS without sufficient wound closure, alcohol consumption, and denture pressure sores. In multivariate analysis, comorbidities, pre-radiotherapy mandibular surgery, poor oral hygiene, and insufficient DAS remained significant. CONCLUSIONS Reducing the risk of ORN calls for maintaining optimal oral hygiene, ensuring good denture fit, receiving proper training in DAS, and helping patients to stop drinking and smoking.
Journal of Cranio-maxillofacial Surgery | 2015
Tobias Fretwurst; Claudia Nack; M. Al-Ghrairi; Jan-Dirk Raguse; Andres Stricker; R. Schmelzeisen; Katja Nelson; Susanne Nahles
OBJECTIVE The purpose of the present study was to evaluate crestal bone level changes around dental implants after iliac bone augmentation in the long term. MATERIAL AND METHODS A total of 32 partially edentulous/edentulous patients (mean age, 52 years; range, 22-70 years) and a remaining bone volume of less than 5 mm of the alveolar ridge underwent maxillary or mandibular iliac bone graft augmentation. All patients received spaced standardized radiological examination for evaluation of peri-implant crestal bone loss. RESULTS The grafting procedure was successfully performed in all patients. A total of 150 implants were placed. The mean observation period was 69 months (range, 12-165 months; success rate for maxilla, 96%; success rate for mandible, 92%). The mean amount of crestal bone loss after 10 years was 1.8 mm. A significant difference between gender and crestal bone loss was shown, but no influence was found regarding the implant system, diameter of implant, and age of the patients. CONCLUSION In patients with atrophic jaws, a sufficient long-term reconstruction can be achieved with the combination of iliac onlay grafting and dental implants. The results demonstrate high success rates and a stable peri-implant bone level in the long term.
Journal of Cranio-maxillofacial Surgery | 2015
Sabine Maria Toso; Kerstin Menzel; Yvonne Motzkus; Martin Klein; Horst Menneking; Jan-Dirk Raguse; Susanne Nahles; Bodo Hoffmeister; Nicolai Adolphs
Optimum functional and aesthetic facial reconstruction is still a challenge in patients who suffer from inborn or acquired facial deformity. It is known that functional and aesthetic impairment can result in significant psychosocial strain, leading to the social isolation of patients who are affected by major facial deformities. Microvascular techniques and increasing experience in facial transplantation certainly contribute to better restorative outcomes. However, these technologies also have some drawbacks, limitations and unsolved problems. Extensive facial defects which include several aesthetic units and dentition can be restored by combining dental prostheses and anaplastology, thus providing an adequate functional and aesthetic outcome in selected patients without the drawbacks of major surgical procedures. Referring to some representative patient cases, it is shown how extreme facial disfigurement after oncological surgery can be palliated by combining intraoral dentures with extraoral facial prostheses using individualized treatment and without the need for major reconstructive surgery.
Journal of Cranio-maxillofacial Surgery | 2015
Fabian Duttenhoefer; Claudia Nack; Christian Doll; Jan-Dirk Raguse; Berthold Hell; Andres Stricker; Katja Nelson; Susanne Nahles
Long-term results of reconstructions and prosthetic rehabilitation of patients presenting severely atrophied edentulous ridges remains a challenge for clinicians. Among the various available augmentation materials there is evidence that avascular fibula bone grafts possess a reliable resistance against resorption and may thus provide a valuable source to reduce the loss of vertical bone height after reconstruction of the severely atrophied mandible and maxilla. The purpose of the present study was to assess long-term crestal bone level stability in avascular fibula bone grafts. 8 edentulous female patients (average age 70.6 years) with Class-VI-atrophy and less than 5 mm residual bone volume received onlay-grafting with avascular fibula bone grafts and were monitored with a mean observation time of 133.7 months (121-186). A total of 39 implants were placed in the maxilla and mandible. Three patients received immediate and five patients delayed implant placement 3 months after grafting. All patients were provided with bar-retained dentures. Postoperative evaluation included clinical implant success (Buser) and radiographic examinations (orthopantomogram) to quantify crestal bone resorption. Grafting was successfully performed in all patients with no regrafting necessary. All implants but one, lost 2 years after abutment connection, remained successfully integrated and fulfilled the Buser criteria, rendering to a success rate of 97%. Mean bone resorption after 10 years was mesial 1.4 mm and distal 1.4 mm at each implant-site. Maximum bone resorption occurred between postoperative and first year, thereafter no significant resorption was measured in re-examinations up to 15 years. Avascular fibula grafts are a reliable bone graft for augmentation procedures in atrophied edentulous ridges. Dental implants that integrated in the autogenous fibular bone grafts showed a stable crestal peri-implant bone level up to 15 years after implant placement.
Journal of Oral Rehabilitation | 2015
C. Nack; Jan-Dirk Raguse; Andres Stricker; Katja Nelson; Susanne Nahles
The aim of this study is to evaluate the clinical and radiological parameters of standard SLA surface implants compared to chemically modified hydrophilic SLActive implants in irradiated patients after the initial 12-month loading period up to 5 years. Twenty patients with a mean age of 61·1 years were treated with dental implants after ablative surgery and radio-chemotherapy of oral cancer. All patients were non-smokers. The placement of 102 implants (50 SLA, 52 SLActive) was performed bilaterally according to a split-mouth design. Mean crestal bone changes were evaluated using standardised orthopantomographies and clinical parameters. Data were analysed using a Kaplan-Meier curve, Mann-Whitney U-test and two-factorial non-parametric analysis. The average observation period was 60 months. The amount of bone loss at the implant shoulder of SLA implants was mesial and distal 0·7 mm. The SLActive implants displayed a bone loss of mesial 0·6 mm as well as distal 0·7 mm after 5 years. Two SLA implants were lost before loading. One patient lost five implants due to recurrence of a tumour. The overall cumulative 12-month, 3-year and 5-year survival rate of SLA implants was 92%, 80% and 75·8% and of SLActive implants 94·2%, 78·8% and 74·4%, respectively. Eighteen implants were considered lost because the patients had died. Sandblasted acid-etched implants with or without a chemically modified surface can be used in irradiated patients with a high predictability of success. Lower implant survival rates in patients with irradiated oral cancer may be associated with systemic effects rather than peri-implantitis.
Journal of Clinical Periodontology | 2015
Tabea Flügge; Katja Nelson; Claudia Nack; Andres Stricker; Susanne Nahles
AIM This study identified the soft tissue changes of the alveolar ridge at different time points within 12 weeks after tooth extraction with and without socket augmentation. MATERIALS AND METHODS In 38 patients with single tooth extractions, 40 sockets were augmented and 39 extraction sockets were not augmented. At 2, 4, 6, 8 and 12 weeks impressions were taken and casts digitized with a laser scanner. The horizontal and vertical changes were compared between augmented and non-augmented sites. A p-value <0.05 was considered statistically significant. RESULTS The mean changes of augmented sockets were between 0.4 mm (2 weeks) and 0.8 mm (12 weeks). In non-augmented sockets changes of 0.7 mm (2 weeks) and of 1.0 mm (12 weeks) were demonstrated. The mean values differed significantly between the buccal and oral region (p < 0.01). Overall, there were significant differences of the mean dimensional changes regarding time (p < 0.01) and augmentation (p < 0.01). CONCLUSIONS Augmented sockets showed less resorption within 4 weeks after extraction compared to non-augmented sockets. Non-augmented sockets showed a continuous dimensional loss with a great variation over 12 weeks whereas augmented sockets had the highest degree of resorption between 4 and 6 weeks. At 12 weeks a comparable resorption in augmented and non-augmented sockets was observed.
International Journal of Oral & Maxillofacial Implants | 2017
Sabine Maria Toso; Kerstin Menzel; Jan-Dirk Raguse; Susanne Nahles
PURPOSE Application of endosseous implants in prosthetic orbital reconstruction seems to be very successful, but few reports have evaluated cumulative survival rates of orbital implants over a long period. The aim of this study was to analyze long-term survival rates and potential influencing factors of orbital implants. MATERIALS AND METHODS A retrospective evaluation of patients treated with extraoral screw implants for retaining orbital prostheses from 1991 to 2014 was performed. Patient records were assessed for implant survival, demographic data, defect etiology, irradiation status, location of implant placement, implant systems, length, and retention type. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. RESULTS A total of 282 orbital implants placed in 78 patients were evaluated during an observation period ranging from 2 to 268 months (mean: 94.97 months). The cumulative implant survival rate was 91.3% at 2 years, 80.5% at 5 years, 68.7% at 10 years, and 62.2% after 15 years. The survival rate was significantly higher in females (75.3%) vs males (47.3%), in supraorbital vs infraorbital implants (67.4% vs 51.5%), and in Brånemark implants (70.2%) vs Straumann implants (54.5%). CONCLUSION The presented data suggest that the long-term predictability of orbital implants revealed good to acceptable results. Factors such as female gender, localization in the supraorbital rim, a machined surface of the implant system, length, and magnetic retention seem to affect the implant survival rate positively, whereas irradiation status does not show any influence. These factors should be considered in planning future patient rehabilitation.
Journal of Periodontal & Implant Science | 2016
Jan Oliver Voss; Tobias Dieke; Christian Doll; Claudia Sachse; Katja Nelson; Jan D. Raguse; Susanne Nahles
Purpose The goal of this study was to evaluate the long-term success of horizontal alveolar crest augmentation of the retromolar region of the mandible with particulated bone, as well as factors affecting subsequent peri-implant bone loss. Methods A total of 109 patients (68 female, 41 male) suffering from alveolar ridge deficiencies of the maxilla and mandible were included in this study. All patients were treated with particulated retromolar bone grafts from the mandible prior to the insertion of endosseous dental implants. Mesial and distal peri-implant crestal bone changes were assessed at six time points. Several parameters, including implant survival and the influence of age, gender, localisation of the implant, diameter, covering procedures, and time points of implant placement, were analysed to identify associations with bone level changes using the Mann-Whitney U-test, the Kruskal-Wallis test, and Spearmans rank-order correlation coefficient. Results A total of 164 dental implants were placed in the maxilla (n=97) and in the mandible (n=67). The mean observation period was 105.26±21.58 months after implantation. The overall survival rate was 97.6% after 10 years. Overall, peri-implant bone loss was highest during the first year, but decreased over time. The mean amount of bone loss after 10 years was 2.47 mm mesially and 2.50 mm distally. Bone loss was significantly influenced by implant type and primary stability. Conclusions The use of particulated autologous retromolar bone grafts is a reliable technique for the horizontal reconstruction of local alveolar ridge deficiencies. Our results demonstrate that implants placed in augmented bone demonstrated similar bone level changes compared to implants inserted in non-augmented regions.