Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Susumu Sugawara is active.

Publication


Featured researches published by Susumu Sugawara.


international conference on control applications | 1999

Development of air-conditioning control algorithm for building energy saving

Fumio Yamada; Kenzo Yonezawa; Susumu Sugawara; Nobutaka Nishimura

In office buildings, the requirement is that the room air-conditioning control system has to provide comfortable thermal feeling for the working people. While energy saving may sometimes conflict with comfort, it is possible to eliminate the wasteful use of energy associated with its overuse without prejudicing the comfort. The basic concept is that the target set values for the room temperature should be changed dynamically so as to suit the constantly changing room environment. The paper shows that the well-known comfort index PMV is useful for air-conditioning control systems aimed at both energy-saving and comfort.


society of instrument and control engineers of japan | 2008

Next generation HVAC system

Yasuyuki Ito; Yoshiki Murakami; Kenzo Yonezawa; Nobutaka Nishimura; Yasuo Takagi; Hiroyuki Morimoto; Susumu Sugawara; Nobuyuki Donen

The new HVAC (heating, ventilation and air conditioning) system for buildings is proposed. The key technology for the system is twin coil air handling unit (AHU) and its advanced control method. One coil is equipped to cool and to dehumidify the fresh air intake, and the other coil is for cooling circulated air. The deeply chilled water is necessary only for remove the moisture from the fresh air. The latter coil requires moderately cool water according to the HVAC load. Then 2 kinds of chilled water in terms of temperature should be prepared. The structure help saving the energy consumption for air-conditioning because the higher chilled water temperature means the better chiller efficiency (COP). Next, the advanced control method that is called dasiaAir-Water cooperation systempsila is introduced. The control system mainly focused on energy savings through changing the temperature of chilled water and supply air according to the HVAC load and weather conditions. In the paper, we introduce Next generation HVAC system with its control system and evaluation results of the system for the model-building simulator.


Archive | 1995

Resident space watching control device

Nobutaka Nishimura; Susumu Sugawara; Tomio Yamada; Kenzo Yonezawa; 富美夫 山田; 憲造 米沢; 進 菅原; 信孝 西村


Archive | 2009

Air conditioning control system, supply air switching controller for use in the air conditioning control system, and air conditioning control method

Kenzo Yonezawa; Yasuo Takagi; Nobutaka Nishimura; Yuuichi Hanada; Naoki Makino; Hideki Oono; Akihiro Fujii; Susumu Sugawara; Tomonori Maegawa; Hiroshi Morimoto


Ieej Transactions on Industry Applications | 1999

Development of Energy-saving Air-Conditioning Control System for Office Building based on Comfort Index

Fumio Yamada; Kenzou Yonezawa; Susumu Sugawara; Nobutaka Nishimura


Archive | 1996

Air conditioning control equipment

Nobutaka Nishimura; Susumu Sugawara; Tomio Yamada; Kenzo Yonezawa


Archive | 2010

Klimaanlagensteuersystem, Frischluftzufuhrumschaltcontroller zur Verwendung bei dem Klimaanlagensteuersystem und Klimaanlagensteuerverfahren

Kenzo Yonezawa; Yasuo Takagi; Nobutaka Nishimura; Yuuichi Hanada; Naoki Makino; Hideki Oono; Akihiro Fujii; Susumu Sugawara; Tomonori Maegawa; Hiroshi Morimoto


Archive | 2009

Air conditioning control system, air supply switching controller used for the same and air conditioning control method

Akita Fujii; Yuichi Hanada; Koichi Ikeda; Naoki Makino; Norifumi Mitsumoto; Hiroyuki Morimoto; Nobutaka Nishimura; Hideki Ono; Susumu Sugawara; Yasuo Takagi; Kenzo Yonezawa; 憲史 三ッ本; 秀樹 大野; 博之 森本; 耕一 池田; 直樹 牧野; 憲造 米沢; 雄一 花田; 進 菅原; 明大 藤井; 信孝 西村; 康夫 高木


Archive | 2009

Air conditioning control system for controlling outside air control and return air control of air conditioning system

Kenzo Yonezawa; Yasuo Takagi; Nobutaka Nishimura; Yuuichi Hanada; Naoki Makino; Hideki Oono; Akihiro Fujii; Susumu Sugawara; Tomonori Maegawa; Hiroshi Morimoto


Archive | 2009

Klimaanlagensteuersystem, Frischluftzufuhrumschaltcontroller zur Verwendung bei dem Klimaanlagensteuersystem und Klimaanlagensteuerverfahren Air conditioning control system Frischluftzufuhrumschaltcontroller for use in the air conditioning control system and air conditioning control method

Akihiro Fujii; Yuuichi Hanada; Tomonori Maegawa; Naoki Makino; Hiroshi Morimoto; Nobutaka Nishimura; Hideki Oono; Susumu Sugawara; Yasuo Takagi; Kenzo Yonezawa

Collaboration


Dive into the Susumu Sugawara's collaboration.

Researchain Logo
Decentralizing Knowledge