Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sy-Chyi Cheng is active.

Publication


Featured researches published by Sy-Chyi Cheng.


Reviews in Analytical Chemistry | 2010

Ambient Ionization Mass Spectrometry

Min-Zong Huang; Cheng-Hui Yuan; Sy-Chyi Cheng; Yi-Tzu Cho; Jentaie Shiea

Mass spectrometric ionization methods that operate under ambient conditions and require minimal or no sample pretreatment have attracted much attention in such fields as biomedicine, food safety, antiterrorism, pharmaceuticals, and environmental pollution. These technologies usually involve separate ionization and sample-introduction events, allowing independent control over each set of conditions. Ionization is typically performed under ambient conditions through use of existing electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) techniques. Rapid analyses of gas, liquid, and solid samples are possible with the adoption of various sample-introduction methods. This review sorts different ambient ionization techniques into two main subcategories, primarily on the basis of the ionization processes, that are further differentiated in terms of the approach used for sampling.


Analytical Chemistry | 2008

Electrospray-Assisted Laser Desorption/Ionization Mass Spectrometry for Continuously Monitoring the States of Ongoing Chemical Reactions in Organic or Aqueous Solution under Ambient Conditions

Chi-Yuan Cheng; Cheng-Hui Yuan; Sy-Chyi Cheng; Min-Zong Huang; Hui-Chiu Chang; Tien-Lu Cheng; Chen-Sheng Yeh; Jentaie Shiea

Electrospray-assisted laser desorption/ionization (ELDI) combined with mass spectrometry allows chemical and biochemical compounds to be characterized directly from hydrophilic and hydrophobic organic solutions mixed with carbon powders under ambient conditions. Organic and inorganic compounds dissolved in polar or nonpolar solvent such as methanol, tetrahydrofuran, ethyl acetate, toluene, dichloromethane, or hexane can be detected using this ambient ionization technique without prior pretreatment. We have used this technique to monitor the progress in several ongoing reactions: the epoxidation of chalcone in ethanol, the chelation of ethylenediaminetetraacetic acid with copper and nickel ions in aqueous solution, the chelation of 1,10-phenanthroline with iron(II) in methanol, and the tryptic digestion of cytochrome c in aqueous solution. Liquid-ELDI analyses simply require irradiation of the surface of the sample solution with a pulsed ultraviolet laser; the laser energy is adsorbed by the carbon powder presuspended in the sample solution; the absorbed laser energy is then transferred to the surrounding solvent and to the analyte molecules in the solution, leading to their desorption; the desorbed gaseous analyte molecules are then postionized within an electrospray (ESI) plume to generate ESI-like analyte ions.


Analytical Chemistry | 2009

Using laser-induced acoustic desorption/electrospray ionization mass spectrometry to characterize small organic and large biological compounds in the solid state and in solution under ambient conditions.

Sy-Chyi Cheng; Tain-Lu Cheng; Hui-Chiu Chang; Jentaie Shiea

We have coupled laser-induced acoustic desorption (LIAD) with electrospray ionization (ESI) mass spectrometry (LIAD/ESI/MS) to characterize molecules in the solid state and in solution under ambient conditions. To perform an LIAD/ESI analysis, the sample droplet is deposited on the surface of a thin aluminum foil by a micropipette; the rear side of the foil with the sample spot is then irradiated with a pulse from a Nd:YAG IR laser. The resulting shockwave and heat cause the sample on the rear side to change from the condensed phase to the gas phase. The desorbed species then move upward to enter an ESI plume to react with charged solvent species (methanol- and water-related ions and droplets), forming singly or multiply charged analyte ions. A quadrupole/time-of-flight (Q-TOF) mass analyzer attached to the LIAD/ESI source detects the analyte ions to obtain an ESI-like mass spectrum. Both small organic and large biological compounds (including amino acids, peptides, and proteins) were successfully ionized and detected by the LIAD/ESI/MS system. Although native and denatured myoglobin ions were both detected from a liquid sample solution, only the denatured myoglobin ions were detected from a dried sample.


Analytical Chemistry | 2008

Detection of Native Protein Ions in Aqueous Solution under Ambient Conditions by Electrospray Laser Desorption/Ionization Mass Spectrometry

Jentaie Shiea; Cheng-Hui Yuan; Min-Zong Huang; Sy-Chyi Cheng; Ya-Lin Ma; Wei-Lung Tseng; Hui-Chiu Chang; Wen-Chun Hung

Liquid electrospray laser desorption/ionization (ELDI) mass spectrometry allows desorption and ionization of proteins directly from aqueous solutions and biological fluids under ambient conditions. Native protein ions such as those of myoglobin, cytochrome c, and hemoglobin were obtained. A droplet (ca. 5 microL) containing the protein molecules and micrometer-sized particles (e.g., carbon graphite powder) is irradiated with a pulsed UV laser. The laser energy adsorbed by the inert particles is transferred to the surrounding solvent and protein molecules, leading to their desorption; the desorbed gaseous molecules are then postionized within an electrospray (ESI) plume to generate the ESI-like protein ions. With the use of this technique, we detected only the protonated protein ions in various biological fluids (including human tears, cow milk, serum, and bacterial extracts) without interference from their corresponding sodiated or potassiated adduct ions. In addition, we rapidly quantified the levels of glycosylated hemoglobin present in drops of whole blood obtained from diabetic patients without the need of sample pretreatment.


Analytical Chemistry | 2009

Thin-Layer Chromatography/Laser-Induced Acoustic Desorption/Electrospray Ionization Mass Spectrometry

Sy-Chyi Cheng; Min-Zong Huang; Jentaie Shiea

The combination of laser-induced acoustic desorption and electrospray ionization mass spectrometry (LIAD/ESI/MS) can be used to rapidly characterize chemical compounds separated on a thin layer chromatography (TLC) plate. We performed LIAD analysis by irradiating the rear side of an aluminum-based TLC plate with a pulsed infrared (IR) laser. To efficiently generate and transfer acoustic and shock waves to ablate the analyte-containing TLC gels, a glass slide was attached to the rear of the TLC plate and the gap between the glass slide and the TLC plate was filled with a viscous solution (glycerol). Although the diameter of the laser spot created on the rear of the TLC plate was approximately 0.35 mm, the ablated areas on the front sides of the silica gel bed and the C(18) reverse-phase gel bed had diameters of approximately 1.3 and 3 mm, respectively. The ablated analyte molecules were ionized in an ESI plume and then detected by an ion trap mass analyzer. This TLC/LIAD/ESI/MS approach allowed the components in mixtures of dye standards, drug standards, and rosemary essential oil to be separated and rapidly characterized.


Rapid Communications in Mass Spectrometry | 2010

Applications of electrospray laser desorption ionization mass spectrometry for document examination

Sy-Chyi Cheng; Yu-Shan Lin; Ming-Zong Huang; Jentaie Shiea

We have employed electrospray laser desorption ionization mass spectrometry (ELDI-MS) to rapidly characterize certain classes of compounds--the inks within the characters made by inks and inkjet printer on regular paper and the chemical compounds within thermal papers. This ELDI-MS approach allowed the ink and paper samples to be distinguished in terms of their chemical compositions. Sample pretreatment was unnecessary and the documents were practically undamaged after examination. The ink chemicals on the documents were desorbed through laser irradiation (sampling spot area: <100 microm(2)); the desorbed molecules then entered an electrospray plume--prepared from an acidic methanol/water solution (50%)--where they became ionized through fusion or ion-molecule reactions with the charged solvent species and droplets in the plume.


Analytical Chemistry | 2013

Rapid characterization of chemical compounds in liquid and solid states using thermal desorption electrospray ionization mass spectrometry.

Min-Zong Huang; Chi-Chang Zhou; De-Lin Liu; Siou-Sian Jhang; Sy-Chyi Cheng; Jentaie Shiea

Rapid characterization of thermally stable chemical compounds in solid or liquid states is achieved through thermal desorption electrospray ionization mass spectrometry (TD-ESI/MS). A feature of this technique is that sampling, desorption, ionization, and mass spectrometric detection are four separate events with respect to time and location. A metal probe was used to sample analytes in their solid or liquid states. The probe was then inserted in a preheated oven to thermally desorb the analytes on the probe. The desorbed analytes were carried by a nitrogen gas stream into an ESI plume, where analyte ions were formed via interactions with charged solvent species generated in the ESI plume. The analyte ions were subsequently detected by a mass analyzer attached to the TD-ESI source. Quantification of acetaminophen in aqueous solutions using TD-ESI/MS was also performed in which a linear response for acetaminophen was obtained between 25 and 500 ppb (R(2) = 0.9978). The standard deviation for a reproducibility test for ten liquid samples was 9.6%. Since sample preparation for TD-ESI/MS is unnecessary, a typical analysis can be completed in less than 10 s. Analytes such as the active ingredients in over-the-counter drugs were rapidly characterized regardless of the different physical properties of said drugs, which included liquid eye drops, viscous cold syrup solution, ointment cream, and a drug tablet. This approach was also used to detect trace chemical compounds in illicit drugs and explosives, in which samples were obtained from the surfaces of a cell phone, piece of luggage made from hard plastic, business card, and wooden desk.


Analytical Chemistry | 2012

Building Blocks for the Development of an Interface for High-Throughput Thin Layer Chromatography/Ambient Mass Spectrometric Analysis: A Green Methodology

Sy-Chyi Cheng; Min-Zong Huang; Li-Chieh Wu; Chih-Chiang Chou; Chu-Nian Cheng; Siou-Sian Jhang; Jentaie Shiea

Interfacing thin layer chromatography (TLC) with ambient mass spectrometry (AMS) has been an important area of analytical chemistry because of its capability to rapidly separate and characterize the chemical compounds. In this study, we have developed a high-throughput TLC-AMS system using building blocks to deal, deliver, and collect the TLC plate through an electrospray-assisted laser desorption ionization (ELDI) source. This is the first demonstration of the use of building blocks to construct and test the TLC-MS interfacing system. With the advantages of being readily available, cheap, reusable, and extremely easy to modify without consuming any material or reagent, the use of building blocks to develop the TLC-AMS interface is undoubtedly a green methodology. The TLC plate delivery system consists of a storage box, plate dealing component, conveyer, light sensor, and plate collecting box. During a TLC-AMS analysis, the TLC plate was sent to the conveyer from a stack of TLC plates placed in the storage box. As the TLC plate passed through the ELDI source, the chemical compounds separated on the plate would be desorbed by laser desorption and subsequently postionized by electrospray ionization. The samples, including a mixture of synthetic dyes and extracts of pharmaceutical drugs, were analyzed to demonstrate the capability of this TLC-ELDI/MS system for high-throughput analysis.


Analytical Chemistry | 2015

Simultaneous detection of polar and nonpolar compounds by ambient mass spectrometry with a dual electrospray and atmospheric pressure chemical ionization source.

Sy-Chyi Cheng; Siou-Sian Jhang; Min-Zong Huang; Jentaie Shiea

A dual ionization source combining electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was developed to simultaneously ionize both polar and nonpolar compounds. The source was constructed by inserting a fused silica capillary into a stainless steel column enclosed in a glass tube. A high dc voltage was applied to a methanol solution flowing in the fused silica capillary to generate an ESI plume at the capillary tip. A high ac voltage was applied to a ring electrode attached to the glass tube to generate plasma from the nitrogen gas flowing between the glass tube and the stainless steel column. The concentric arrangement of the ESI plume and the APCI plasma in the source ensured that analytes entering the ionization region interacted with both ESI and APCI primary ion species generated in the source. Because the high voltages required for ESI and APCI were independently applied and controlled, the dual ion source could be operated in ESI-only, APCI-only, or ESI+APCI modes. Analytes were introduced into the ESI and/or APCI plumes by irradiating sample surfaces with a continuous-wavelength laser or a pulsed laser beam. Analyte ions could also be produced by directing the dual ESI+APCI source toward sample surfaces for desorption and ionization. The ionization mechanisms involved in the dual ion source include Penning ionization, ion molecule reactions, and fused-droplet electrospray ionization. Standards of polycyclic aromatic hydrocarbons, angiotensin I, lidocaine, ferrocene, diesel, and rosemary oils were used for testing. Protonated analyte ions were detected in ESI-only mode, radical cations were detected in APCI-only mode, and both types of ions were detected in ESI+APCI mode.


Analytical Chemistry | 2016

Formation of Metal-Adducted Analyte Ions by Flame-Induced Atmospheric Pressure Chemical Ionization Mass Spectrometry

Sy-Chyi Cheng; Chin-Hsiung Wang; Jentaie Shiea

A flame-induced atmospheric pressure chemical ionization (FAPCI) source, consisting of a miniflame, nebulizer, and heated tube, was developed to ionize analytes. The ionization was performed by reacting analytes with a charged species generated in a flame. A stainless steel needle deposited with saturated alkali chloride solution was introduced into the mini oxyacetylene flame to generate alkali ions, which were reacted with analytes (M) generated in a heated nebulizer. The alkali-adducted 18-crown-6 ether ions, including (M + Li)(+), (M + Na)(+), (M + K)(+), (M + Rb)(+), and (M + Cs)(+), were successfully detected on the FAPCI mass spectra when the corresponding alkali chloride solutions were separately introduced to the flame. When an alkali chloride mixture was introduced, all alkali-adducted analyte ions were simultaneously detected. Their intensity order was as follows: (M + Cs)(+) > (M + Rb)(+) > (M + K)(+) > (M + Na)(+) > (M + Li)(+), and this trend agreed with the lattice energies of alkali chlorides. Besides alkali ions, other transition metal ions such as Ni(+), Cu(+), and Ag(+) were generated in a flame for analyte ionization. Other than metal ions, the reactive species generated in the fossil fuel flame could also be used to ionize analytes, which formed protonated analyte ions (M + H)(+) in positive ion mode and deprotonated analyte ions (M - H)(-) in negative ion mode.

Collaboration


Dive into the Sy-Chyi Cheng's collaboration.

Top Co-Authors

Avatar

Jentaie Shiea

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Min-Zong Huang

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Siou-Sian Jhang

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Cheng-Hui Yuan

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Chu-Nian Cheng

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Hui-Chiu Chang

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Suhail Muzaffar Bhat

National Sun Yat-sen University

View shared research outputs
Top Co-Authors

Avatar

Yeou-Lih Huang

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Chi-Wei Lee

Kaohsiung Medical University

View shared research outputs
Top Co-Authors

Avatar

Chih-Chiang Chou

National Sun Yat-sen University

View shared research outputs
Researchain Logo
Decentralizing Knowledge