Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sylvain Biéler is active.

Publication


Featured researches published by Sylvain Biéler.


PLOS Neglected Tropical Diseases | 2014

Evaluation of the diagnostic accuracy of prototype rapid tests for human African trypanosomiasis.

Jeremy M. Sternberg; Marek Gierliński; Sylvain Biéler; Michael A. J. Ferguson; Joseph M. Ndung'u

Background Diagnosis of human African trypanosomiasis (HAT) remains a challenge both for active screening, which is critical in control of the disease, and in the point-of-care scenario where early and accurate diagnosis is essential. Recently, the first field deployment of a lateral flow rapid diagnostic test (RDT) for HAT, “SD BIOLINE HAT” has taken place. In this study, we evaluated the performance of “SD BIOLINE HAT” and two new prototype RDTs. Methodology/Principal Findings The performance of “SD BIOLINE HAT” and 2 prototype RDTs was tested using archived plasma from 250 Trypanosoma brucei gambiense patients, and 250 endemic controls. As well as comparison of the sensitivity and specificity of each device, the performance of individual antigens was assessed and the hypothetical performance of novel antigen combinations extrapolated. Neither of the prototype devices were inferior in sensitivity or specificity to “SD BIOLINE HAT” (sensitivity 0.82±0.01, specificity 0.97±0.01, 95% CI) at the 5% margins, while one of the devices (BBI) had significantly superior sensitivity (0.88±0.03). Analysis of the performance of individual antigens was used to model new antigen combinations to be explored in development of the next generation of HAT RDTs. The modelling showed that an RDT using two recombinant antigens (rLiTat1.5 and rISG65) would give a performance similar to the best devices in this study, and would also offer the most robust performance under deteriorating field conditions. Conclusions/Significance Both “SD BIOLINE HAT” and the prototype devices performed comparably well to one another and also to the published performance range of the card agglutination test for trypanosomiasis in sensitivity and specificity. The performance of individual antigens enabled us to predict that an all-recombinant antigen RDT can be developed with an accuracy equivalent to “ SD BIOLINE HAT.” Such an RDT would have advantages in simplified manufacture, lower unit cost and assured reproducibility.


Acta Tropica | 2012

Improved detection of Trypanosoma brucei by lysis of red blood cells, concentration and LED fluorescence microscopy.

Sylvain Biéler; Enock Matovu; Patrick Mitashi; Edward Ssewannyana; Stomy Karhemere Bi Shamamba; Paul R. Bessell; Joseph Mathu Ndung’u

Confirmatory diagnosis of African trypanosomiasis relies on demonstration of parasites in body fluids by bright field microscopy. The parasitaemia in infected patients and animals is usually low, and concentration methods are used to try and increase the chances of seeing parasites. Recently, fluorescence microscopes using light-emitting diodes (LED) have been developed. Since they emit strong light, their use does not require a dark room, making field application a possibility. We have combined LED fluorescence microscopy with lysis of red blood cells (RBC) to improve the sensitivity and speed of detecting trypanosomes. In studies conducted at four centers in Uganda and the Democratic Republic of the Congo, parasitaemic blood was serially diluted and the RBCs lysed using commercial buffer. Samples were then concentrated by centrifugation, and different volumes of the sediment used to make thin and thick smears. Next, these were stained with acridine orange or Giemsa, and examined using an LED microscope under fluorescence or bright light, respectively. Detection of parasites was significantly improved by RBC lysis and concentration, regardless of the staining and microscopy method used. Further improvements were made when smears were prepared using larger volumes of sediment. The best results were obtained with thin smears prepared using 20 μl of sediment and stained with acridine orange. The time taken to see the first parasite was dramatically reduced when smears were examined by LED fluorescence microscopy, compared to bright light. LED fluorescence microscopy was found to be easier and requiring less visual effort than bright field microscopy. These studies demonstrate the potential for incremental improvement in detection of Trypanosoma brucei by combining LED fluorescence microscopy with RBC lysis and concentration. The lysis and concentration method may also be useful in sample preparation for other diagnostic tests for trypanosomiasis.


PLOS Neglected Tropical Diseases | 2010

Piggy-backing on diagnostic platforms brings hope to neglected diseases: the case of sleeping sickness.

Joseph M. Ndung'u; Sylvain Biéler; Giorgio Roscigno

Neglected infectious diseases (NIDs) attract little interest from commercial companies that invest in diagnostics and therapeutics, mainly because the people that they affect are amongst the poorest in the world, who cannot afford to pay for them. Many commercial companies shy away from manufacturing diagnostic tests for NIDs because a return on investment is not usually guaranteed.


PLOS Neglected Tropical Diseases | 2016

Sensitivity and Specificity of a Prototype Rapid Diagnostic Test for the Detection of Trypanosoma brucei gambiense Infection: A Multi-centric Prospective Study

Sylvie Bisser; Crispin Lumbala; Etienne Nguertoum; Victor Kande; Laurence Flevaud; Gedeao Vatunga; Marleen Boelaert; Philippe Büscher; Théophile Josenando; Paul R. Bessell; Sylvain Biéler; Joseph Mathu Ndung’u

Background A major challenge in the control of human African trypanosomiasis (HAT) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. In Trypanosoma brucei gambiense HAT, the Card Agglutination Test for Trypanosomiasis (CATT) has been the reference screening test since 1978, usually on whole blood, but also in a 1/8 dilution (CATT 1/8) to enhance specificity. However, the CATT is not available in a single format, requires a cold chain for storage, and uses equipment that requires electricity. A solution to these challenges has been provided by rapid diagnostic tests (RDT), which have recently become available. A prototype immunochromatographic test, the SD BIOLINE HAT, based on two native trypanosomal antigens (VSG LiTat 1.3 and VSG LiTat 1.5) has been developed. We carried out a non-inferiority study comparing this prototype to the CATT 1/8 in field settings. Methodology/Principal Findings The prototype SD BIOLINE HAT, the CATT Whole Blood and CATT 1/8 were systematically applied on fresh blood samples obtained from 14,818 subjects, who were prospectively enrolled through active and passive screening in clinical studies in three endemic countries of central Africa: Angola, the Democratic Republic of the Congo and the Central African Republic. One hundred and forty nine HAT cases were confirmed by parasitology. The sensitivity and specificity of the prototype SD BIOLINE HAT was 89.26% (95% confidence interval (CI) = 83.27–93.28) and 94.58% (95% CI = 94.20–94.94) respectively. The sensitivity and specificity of the CATT on whole blood were 93.96% (95% CI = 88.92–96.79) and 95.91% (95% CI = 95.58–96.22), and of the CATT 1/8 were 89.26% (95% CI = 83.27–93.28) and 98.88% (95% CI = 98.70–99.04) respectively. Conclusion/Significance After further optimization, the prototype SD BIOLINE HAT could become an alternative to current screening methods in primary healthcare settings in remote, resource-limited regions where HAT typically occurs.


PLOS Neglected Tropical Diseases | 2016

Metabolomics Identifies Multiple Candidate Biomarkers to Diagnose and Stage Human African Trypanosomiasis

Isabel M. Vincent; Rónán Daly; Bertrand Courtioux; Amy M. Cattanach; Sylvain Biéler; Joseph Mathu Ndung’u; Sylvie Bisser; Michael P. Barrett

Treatment for human African trypanosomiasis is dependent on the species of trypanosome causing the disease and the stage of the disease (stage 1 defined by parasites being present in blood and lymphatics whilst for stage 2, parasites are found beyond the blood-brain barrier in the cerebrospinal fluid (CSF)). Currently, staging relies upon detecting the very low number of parasites or elevated white blood cell numbers in CSF. Improved staging is desirable, as is the elimination of the need for lumbar puncture. Here we use metabolomics to probe samples of CSF, plasma and urine from 40 Angolan patients infected with Trypanosoma brucei gambiense, at different disease stages. Urine samples provided no robust markers indicative of infection or stage of infection due to inherent variability in urine concentrations. Biomarkers in CSF were able to distinguish patients at stage 1 or advanced stage 2 with absolute specificity. Eleven metabolites clearly distinguished the stage in most patients and two of these (neopterin and 5-hydroxytryptophan) showed 100% specificity and sensitivity between our stage 1 and advanced stage 2 samples. Neopterin is an inflammatory biomarker previously shown in CSF of stage 2 but not stage 1 patients. 5-hydroxytryptophan is an important metabolite in the serotonin synthetic pathway, the key pathway in determining somnolence, thus offering a possible link to the eponymous symptoms of “sleeping sickness”. Plasma also yielded several biomarkers clearly indicative of the presence (87% sensitivity and 95% specificity) and stage of disease (92% sensitivity and 81% specificity). A logistic regression model including these metabolites showed clear separation of patients being either at stage 1 or advanced stage 2 or indeed diseased (both stages) versus control.


PLOS ONE | 2017

Performance of the SD BIOLINE® HAT rapid test in various diagnostic algorithms for gambiense human African trypanosomiasis in the Democratic Republic of the Congo

Crispin Lumbala; Paul R. Bessell; Pascal Lutumba; Sylvain Baloji; Sylvain Biéler; Joseph M. Ndung'u; Ana Paula Arez

We carried out a study to compare the performance, in terms of sensitivity and specificity, of the new SD BIOLINE® HAT rapid diagnostic test (RDT) with the card agglutination test for trypanosomiasis (CATT) for diagnosis of human African trypanosomiasis (HAT) in the Democratic Republic of the Congo (DRC). Participants were enrolled actively by four mobile teams, and passively at four health facilities in three provinces. Consenting participants were tested concurrently with the RDT and CATT on whole blood. Those found positive by either test were tested with CATT on serial dilutions of plasma, and with a parasitological composite reference standard (CRS). Cases were only the individuals found positive by the CRS, while controls were negative by both CATT and RDT, as well as those that were positive by CATT or RDT, but were negative by the CRS, and had no history of HAT. Over five months, 131 cases and 13,527 controls were enrolled. The sensitivity of the RDT was 92.0% (95% confidence interval (CI) = 86.1–95.5), which was significantly higher than CATT (sensitivity 69.1%; 95% CI = 60.7–76.4). The sensitivity of CATT on plasma at a dilution of 1:8 was 59.0% (95% CI = 50.2–67.2). The specificity of the RDT was 97.1% (95% CIs = 96.8–97.4) while that of CATT was 98.0% (95% CIs = 97.8, 98.2) and specificities of algorithms involving CATT at 1:8 dilution were 99.6% (95% CI = 99.5–99.7). Reproducibility of results was excellent. We concluded that an algorithm in which the SD BIOLINE® HAT RDT is used for screening is optimal for case detection in both passive and active screening settings. However, the lower specificity of the RDT compared to that of CATT would result in a larger number of false positive individuals undergoing confirmatory testing.


PLOS ONE | 2017

Enhanced passive screening and diagnosis for gambiense human African trypanosomiasis in north-western Uganda – Moving towards elimination

Charles Wamboga; Enock Matovu; Paul R. Bessell; Albert Picado; Sylvain Biéler; Joseph Mathu Ndung’u

Introduction The incidence of gambiense human African trypanosomiasis (gHAT) in Uganda has been declining, from 198 cases in 2008, to only 20 in 2012. Interruption of transmission of the disease by early diagnosis and treatment is core to the control and eventual elimination of gHAT. Until recently, the format of available screening tests had restricted screening and diagnosis to central health facilities (passive screening). We describe a novel strategy that is contributing to elimination of gHAT in Uganda through expansion of passive screening to the entire population at risk. Methodology / Principal findings In this strategy, patients who are clinically suspected of having gHAT at primary health facilities are screened using a rapid diagnostic test (RDT), followed by parasitological confirmation at strategically located microscopy centres. For patients who are positive with the RDT and negative by microscopy, blood samples undergo further testing using loop-mediated isothermal amplification (LAMP), a molecular test that detects parasite DNA. LAMP positive patients are considered strong suspects, and are re-evaluated by microscopy. Location and upgrading of facilities to perform microscopy and LAMP was informed by results of georeferencing and characterization of all public healthcare facilities in the 7 gHAT endemic districts in Uganda. Three facilities were upgraded to perform RDTs, microscopy and LAMP, 9 to perform RDTs and microscopy, and 200 to screen patients with RDTs. This reduced the distance that a sick person must travel to be screened for gHAT to a median distance of 2.5km compared to 23km previously. In this strategy, 9 gHAT cases were diagnosed in 2014, and 4 in 2015. Conclusions This enhanced passive screening strategy for gHAT has enabled full coverage of the population at risk, and is being replicated in other gHAT endemic countries. The improvement in case detection is making elimination of the disease in Uganda an imminent possibility.


PLOS Neglected Tropical Diseases | 2018

Prospective evaluation of a rapid diagnostic test for Trypanosoma brucei gambiense infection developed using recombinant antigens

Crispin Lumbala; Sylvain Biéler; Simon Kayembe; Jacquies Makabuza; Stefano Ongarello; Joseph Mathu Ndung’u

Background Diagnosis and treatment are central elements of strategies to control Trypanosoma brucei gambiense human African trypanosomiasis (HAT). Serological screening is a key entry point in diagnostic algorithms. The Card Agglutination Test for Trypanosomiasis (CATT) has been the most widely used screening test for decades, despite a number of practical limitations that were partially addressed by the introduction of rapid diagnostic tests (RDTs). However, current RDTs are manufactured using native antigens, which are challenging to produce. Methodology/Principal findings The objective of this study was to evaluate the accuracy of a new RDT developed using recombinant antigens (SD BIOLINE HAT 2.0), in comparison with an RDT produced using native antigens (SD BIOLINE HAT) and CATT. A total of 57,632 individuals were screened in the Democratic Republic of the Congo, either passively at 10 health centres, or actively by 5 mobile teams, and 260 HAT cases were confirmed by parasitology. The highest sensitivity was achieved with the SD BIOLINE HAT 2.0 (71.2%), followed by CATT (62.5%) and the SD BIOLINE HAT (59.0%). The most specific test was CATT (99.2%), while the specificity of the SD BIOLINE HAT and SD BIOLINE HAT 2.0 were 98.9% and 98.1%, respectively. Sensitivity of the tests was lower than previously reported, as they identified cases from partially overlapping sub-populations. All three tests were significantly more sensitive in passive than in active screening. Combining two or three tests resulted in a markedly increased sensitivity: When the SD BIOLINE HAT was combined with the SD BIOLINE HAT 2.0, sensitivity reached 98.4% in passive and 83.0% in active screening. Conclusions/Significance The recombinant antigen-based RDT was more sensitive than, and as specific as, the SD BIOLINE HAT. It was as sensitive as, but slightly less specific than CATT. While the practicality and cost-effectiveness of algorithms including several screening tests would need to be investigated, using two or more tests appears to enhance sensitivity of diagnostic algorithms, although some decrease in specificity is observed as well.


PLOS ONE | 2016

Evaluation of Antigens for Development of a Serological Test for Human African Trypanosomiasis

Sylvain Biéler; Harald Waltenberger; Michael P. Barrett; Richard McCulloch; Jeremy C. Mottram; Mark Carrington; Wilhelm J. Schwaeble; James H. McKerrow; Margaret A. Phillips; Paul A. M. Michels; Philippe Büscher; Jean-Charles Sanchez; Richard P. Bishop; Derrick R. Robinson; Michael A. J. Ferguson; Barbara Nerima; Audrey Albertini; Gerd Michel; Magdalena Radwandska; Joseph M. Ndung'u

Background Control and elimination of human African trypanosomiasis (HAT) can be accelerated through the use of diagnostic tests that are more accurate and easier to deploy. The goal of this work was to evaluate the immuno-reactivity of antigens and identify candidates to be considered for development of a simple serological test for the detection of Trypanosoma brucei gambiense or T. b. rhodesiense infections, ideally both. Methodology/Principal Findings The reactivity of 35 antigens was independently evaluated by slot blot and ELISA against sera from both T. b. gambiense and T. b. rhodesiense infected patients and controls. The antigens that were most reactive by both tests to T. b. gambiense sera were the membrane proteins VSG LiTat 1.3, VSG LiTat 1.5 and ISG64. Reactivity to T. b. rhodesiense sera was highest with VSG LiTat 1.3, VSG LiTat 1.5 and SRA, although much lower than with T. b. gambiense samples. The reactivity of all possible combinations of antigens was also calculated. When the slot blot results of 2 antigens were paired, a VSG LiTat 1.3- ISG75 combination performed best on T. b. gambiense sera, while a VSG LiTat 1.3-VSG LiTat 1.5 combination was the most reactive using ELISA. A combination of SRA and either VSG LiTat 1.3 or VSG LiTat 1.5 had the highest reactivity on T. b. rhodesiense sera according to slot blot, while in ELISA, pairing SRA with either GM6 or VSG LiTat 1.3 yielded the best results. Conclusions This study identified antigens that were highly reactive to T. b. gambiense sera, which could be considered for developing a serological test for gambiense HAT, either individually or in combination. Antigens with potential for inclusion in a test for T. b. rhodesiense HAT were also identified, but because their reactivity was comparatively lower, a search for additional antigens would be required before developing a test for this form of the disease.


Parasites & Vectors | 2018

Evaluation of fluorimetry and direct visualization to interpret results of a loop-mediated isothermal amplification kit to detect Leishmania DNA

Ana V. Ibarra-Meneses; Israel Cruz; Carmen Chicharro; Carmen Sánchez; Sylvain Biéler; Tobias Broger; Javier Moreno; Eugenia Carrillo

BackgroundNucleic acid amplification tests (NAATs) have proven to be advantageous in the diagnosis of leishmaniases, allowing sensitive diagnosis of: (i) cutaneous leishmaniasis in long duration lesions and (ii) visceral leishmaniasis using a less-invasive sample like peripheral blood, in opposition to tissue aspiration required for parasite demonstration by microscopy. Despite their benefits, the implementation of NAATs for leishmaniasis diagnosis at the point-of-care has not been achieved yet, mostly due to the complexity and logistical issues associated with PCR-based methods.MethodsIn this work, we have evaluated the performance of a ready-to-use loop-mediated isothermal amplification (LAMP) kit using two real time fluorimeters to amplify leishmanial DNA obtained by silica column-based and Boil & Spin protocols.ResultsThe different approaches used to run and interpret the LAMP reactions showed a performance equivalent to PCR and real-time PCR, using spiked and clinical samples. The time to positivity obtained with real-time fluorimetry showed an excellent correlation with both Ct values and parasite load from real-time quantitative PCR.ConclusionsThe results obtained open the possibility of using a highly stable, ready-to-use LAMP kit for the accurate diagnosis of leishmaniasis at the point-of-care. Furthermore, the feasibility of relating time to positivity, determined with a portable real-time fluorimeter, with the parasite burden could have a wider application in the management of leishmaniasis, such as in treatment efficacy monitoring or as a pharmacodynamics tool in clinical trials.

Collaboration


Dive into the Sylvain Biéler's collaboration.

Top Co-Authors

Avatar

Joseph M. Ndung'u

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Joseph Mathu Ndung’u

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Paul R. Bessell

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Philippe Büscher

Institute of Tropical Medicine Antwerp

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Paul R. Bessell

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge