Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Sylvain Gioux is active.

Publication


Featured researches published by Sylvain Gioux.


Molecular Imaging | 2010

Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Sylvain Gioux; Hak Soo Choi; John V. Frangioni

The field of biomedical optics has matured rapidly over the last decade and is poised to make a significant impact on patient care. In particular, wide-field (typically > 5 cm), planar, near-infrared (NIR) fluorescence imaging has the potential to revolutionize human surgery by providing real-time image guidance to surgeons for tissue that needs to be resected, such as tumors, and tissue that needs to be avoided, such as blood vessels and nerves. However, to become a clinical reality, optimized imaging systems and NIR fluorescent contrast agents will be needed. In this review, we introduce the principles of NIR fluorescence imaging, analyze existing NIR fluorescence imaging systems, and discuss the key parameters that guide contrast agent development. We also introduce the complexities surrounding clinical translation using our experience with the Fluorescence-Assisted Resection and Exploration (FLARE™) imaging system as an example. Finally, we introduce state-of-the-art optical imaging techniques that might someday improve image-guided surgery even further.


Journal of Biomedical Optics | 2009

Three-dimensional surface profile intensity correction for spatially modulated imaging

Sylvain Gioux; Amaan Mazhar; David J. Cuccia; Anthony J. Durkin; Bruce J. Tromberg; John V. Frangioni

We describe a noncontact profile correction technique for quantitative, wide-field optical measurement of tissue absorption (microa) and reduced scattering (micros) coefficients, based on geometric correction of the samples Lambertian (diffuse) reflectance intensity. Because the projection of structured light onto an object is the basis for both phase-shifting profilometry and modulated imaging, we were able to develop a single instrument capable of performing both techniques. In so doing, the surface of the three-dimensional object could be acquired and used to extract the objects optical properties. The optical properties of flat polydimethylsiloxane (silicone) phantoms with homogenous tissue-like optical properties were extracted, with and without profilometry correction, after vertical translation and tilting of the phantoms at various angles. Objects having a complex shape, including a hemispheric silicone phantom and human fingers, were acquired and similarly processed, with vascular constriction of a finger being readily detectable through changes in its optical properties. Using profilometry correction, the accuracy of extracted absorption and reduced scattering coefficients improved from two- to ten-fold for surfaces having height variations as much as 3 cm and tilt angles as high as 40 deg. These data lay the foundation for employing structured light for quantitative imaging during surgery.


Journal of Biomedical Optics | 2011

First-in-human pilot study of a spatial frequency domain oxygenation imaging system.

Sylvain Gioux; Amaan Mazhar; Bernard T. Lee; Samuel J. Lin; Adam M. Tobias; David J. Cuccia; Alan Stockdale; Rafiou Oketokoun; Yoshitomo Ashitate; Edward Kelly; Maxwell Weinmann; Nicholas J. Durr; Lorissa A. Moffitt; Anthony J. Durkin; Bruce J. Tromberg; John V. Frangioni

Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.


Surgery | 2010

Real-time intra-operative near-infrared fluorescence identification of the extrahepatic bile ducts using clinically available contrast agents

Aya Matsui; Eiichi Tanaka; Hak Soo Choi; Joshua H. Winer; Vida Kianzad; Sylvain Gioux; Rita G. Laurence; John V. Frangioni

BACKGROUND Iatrogenic bile duct injuries are serious complications with patient morbidity. We hypothesized that the invisible near-infrared (NIR) fluorescence properties of methylene blue (MB) and indocyanine green (ICG) could be exploited for real-time, intraoperative imaging of the extrahepatic bile ducts during open and laparoscopic surgeries. METHODS In all, 2.0 mg/kg of MB and 0.05 mg/kg of ICG were injected intravenously into 35-kg female Yorkshire pigs and the extrahepatic bile ducts were imaged over time using either the Fluorescence-Assisted Resection and Exploration (FLARE) image-guided surgery system (open surgery) or a custom NIR fluorescence laparoscopy system. Surgical anatomy was confirmed using x-ray cholangiography. The contrast-to-background ratio (CBR), contrast-to-liver ratio (CLR), and chemical concentrations in the cystic duct (CD) and common bile duct (CBD) were measured, and the performance of each agent was quantified. RESULTS Using NIR fluorescence of MB, the CD and CBD could be identified with good sensitivity (CBR and CLR > or =4), during both open and laparoscopic surgeries, from 10 to 120 min postinjection. Functional impairment of the ducts, including constriction and injury were immediately identifiable. Using NIR fluorescence of ICG, extrahepatic bile ducts did not become visible until 90 min postinjection because of strong residual liver retention; however, between 90 and 240 min, ICG provided exquisitely high sensitivity for both CD and CBD, with CBR > or =8 and CLR > or =4. CONCLUSION We demonstrate that 2 clinically available NIR fluorophores, MB fluorescing at 700 nm and ICG fluorescing at 800 nm, provide sensitive, prolonged identification of the extrahepatic bile ducts and assessment of their functional status.


Plastic and Reconstructive Surgery | 2010

The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in perforator flap breast reconstruction.

Bernard T. Lee; Merlijn Hutteman; Sylvain Gioux; Alan Stockdale; Samuel J. Lin; Long Ngo; John V. Frangioni

Background: The ability to determine flap perfusion in reconstructive surgery is still primarily based on clinical examination. In this study, the authors demonstrate the use of an intraoperative, near-infrared fluorescence imaging system for evaluation of perforator location and flap perfusion. Methods: Indocyanine green was injected intravenously in six breast cancer patients undergoing a deep inferior epigastric perforator flap breast reconstruction after mastectomy. Three dose levels of indocyanine green were assessed using the fluorescence-assisted resection and exploration (FLARE) imaging system. This system uses light-emitting diodes for fluorescence excitation, which is different from current commercially available systems. In this pilot study, the operating surgeons were blinded to the imaging results. Results: Use of the FLARE system was successful in all six study subjects, with no complications or sequelae. Among the three dose levels, 4 mg per injection resulted in the highest observed contrast-to-background ratio, signal-to-background ratio, and signal-to-noise ratio. However, because of small sample size, the authors did not have sufficient power to detect statistical significance for these pairwise comparisons at the multiple-comparison adjusted type I error of 0.017. Six milligrams per injection provided a similar contrast-to-background ratio but also a higher residual background signal. Conclusion: Based on this pilot study, the authors conclude that near-infrared assessment of perforator flap breast reconstruction is feasible with a light-emitting diode–based system, and that a dose of 4 mg of indocyanine green per injection yields the best observed contrast-to-background ratio compared with a dose of 2 or 6 mg for assessment of flap perfusion.


Surgery | 2010

Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue

Aya Matsui; Eiichi Tanaka; Hak Soo Choi; Vida Kianzad; Sylvain Gioux; Stephen Johnson Lomnes; John V. Frangioni

BACKGROUND The aim of this study was to determine whether the invisible near-infrared (NIR) fluorescence properties of methylene blue (MB), a dye already approved by the U.S. Food and Drug Administration for other indications, could be exploited for real-time, intra-operative identification of the ureters. METHODS The optical properties of MB were quantified in vitro. Open surgery and laparoscopic NIR fluorescence imaging systems were employed. Yorkshire pigs were injected intravenously with 0.1-mg/kg MB (n = 8), 10-mg furosemide followed by 0.1-mg/kg MB (n = 6), or 0.5-mg/kg MB (n = 6). The contrast-to-background ratio (CBR) of the kidney and ureters, and the MB concentration in the urine, were quantified. RESULTS Peak MB absorbance, emission, and intensity in urine occurred at 668 nm, 688 nm, and 20 mumol/L, respectively. After intravenous injection, doses as low as 0.1-mg/kg MB provided prolonged imaging of the ureters, and a dose of 0.5 mg/kg provided statistically significant improvement of CBR. The preinjection of furosemide increased urine volume but did not improve CBR. Laparoscopic identification of the ureter using MB NIR fluorescence was demonstrated. CONCLUSION Ureteral imaging using MB NIR fluorescence provides sensitive, real-time, intra-operative identification of the ureters during open and laparoscopic surgeries.


Journal of Biomedical Optics | 2010

Structured illumination enhances resolution and contrast in thick tissue fluorescence imaging

Amaan Mazhar; David J. Cuccia; Sylvain Gioux; Anthony J. Durkin; John V. Frangioni; Bruce J. Tromberg

We introduce a noncontact imaging method utilizing multifrequency structured illumination for improving lateral and axial resolution and contrast of fluorescent molecular probes in thick, multiple-scattering tissue phantoms. The method can be implemented rapidly using a spatial light modulator and a simple image demodulation scheme similar to structured light microscopy in the diffraction regime. However, imaging is performed in the multiple-scattering regime utilizing spatially modulated scalar photon density waves. We demonstrate that by increasing the structured light spatial frequency, fluorescence from deeper structures is suppressed and signals from more superficial objects enhanced. By measuring the spatial frequency dependence of fluorescence, background can be reduced by localizing the signal to a buried fluorescent object. Overall, signal-to-background ratio (SBR) and resolution improvements are dependent on spatial frequency and object depth/dimension with as much as sevenfold improvement in SBR and 33% improvement in resolution for approximately 1-mm objects buried 3 mm below the surface in tissue-like media with fluorescent background.


Journal of Biomedical Optics | 2010

Wavelength optimization for rapid chromophore mapping using spatial frequency domain imaging.

Amaan Mazhar; Steven J. O’Dell; David J. Cuccia; Sylvain Gioux; Anthony J. Durkin; John V. Frangioni; Bruce J. Tromberg

Spatial frequency-domain imaging (SFDI) utilizes multiple-frequency structured illumination and model-based computation to generate two-dimensional maps of tissue absorption and scattering properties. SFDI absorption data are measured at multiple wavelengths and used to fit for the tissue concentration of intrinsic chromophores in each pixel. This is done with a priori knowledge of the basis spectra of common tissue chromophores, such as oxyhemoglobin (ctO(2)Hb), deoxyhemoglobin (ctHHb), water (ctH(2)O), and bulk lipid. The quality of in vivo SFDI fits for the hemoglobin parameters ctO(2)Hb and ctHHb is dependent on wavelength selection, fitting parameters, and acquisition rate. The latter is critical because SFDI acquisition time is up to six times longer than planar two-wavelength multispectral imaging due to projection of multiple-frequency spatial patterns. Thus, motion artifact during in vivo measurements compromises the quality of the reconstruction. Optimal wavelength selection is examined through matrix decomposition of basis spectra, simulation of data, and dynamic in vivo measurements of a human forearm during cuff occlusion. Fitting parameters that minimize cross-talk from additional tissue chromophores, such as water and lipid, are determined. On the basis of this work, a wavelength pair of 670 nm∕850 nm is determined to be the optimal two-wavelength combination for in vivo hemodynamic tissue measurements provided that assumptions for water and lipid fractions are made in the fitting process. In our SFDI case study, wavelength optimization reduces acquisition time over 30-fold to 1.5s compared to 50s for a full 34-wavelength acquisition. The wavelength optimization enables dynamic imaging of arterial occlusions with improved spatial resolution due to reduction of motion artifacts.


Molecular Imaging | 2009

High-power, computer-controlled, light-emitting diode-based light sources for fluorescence imaging and image-guided surgery.

Sylvain Gioux; Vida Kianzad; Razvan Ciocan; Sunil Gupta; Rafiou Oketokoun; John V. Frangioni

Optical imaging requires appropriate light sources. For image-guided surgery, in particular fluorescence-guided surgery, a high fluence rate, a long working distance, computer control, and precise control of wavelength are required. In this article, we describe the development of light-emitting diode (LED)-based light sources that meet these criteria. These light sources are enabled by a compact LED module that includes an integrated linear driver, heat dissipation technology, and real-time temperature monitoring. Measuring only 27 mm wide by 29 mm high and weighing only 14.7 g, each module provides up to 6,500 lx of white (400–650 nm) light and up to 157 mW of filtered fluorescence excitation light while maintaining an operating temperature ≤ 50°C. We also describe software that can be used to design multimodule light housings and an embedded processor that permits computer control and temperature monitoring. With these tools, we constructed a 76-module, sterilizable, three-wavelength surgical light source capable of providing up to 40,000 lx of white light, 4.0 mW/cm2 of 670 nm near-infrared (NIR) fluorescence excitation light, and 14.0 mW/cm2 of 760 nm NIR fluorescence excitation light over a 15 cm diameter field of view. Using this light source, we demonstrated NIR fluorescence–guided surgery in a large-animal model.


Biomedical Optics Express | 2013

Single snapshot imaging of optical properties

Jean Vervandier; Sylvain Gioux

A novel acquisition and processing method that enables single snapshot wide field imaging of optical properties in the Spatial Frequency Domain (SFD) is described. This method makes use of a Fourier transform performed on a single image and processing in the frequency space to extract two spatial frequency images at once. The performance of the method is compared to the standard six image SFD acquisition method, assessed on tissue mimicking phantoms and in vivo. Overall both methods perform similarly in extracting optical properties.

Collaboration


Dive into the Sylvain Gioux's collaboration.

Top Co-Authors

Avatar

John V. Frangioni

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar

Bernard T. Lee

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar

Yoshitomo Ashitate

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar

John Nguyen

West Virginia University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alan Stockdale

Beth Israel Deaconess Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vivek Venugopal

Rensselaer Polytechnic Institute

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge