Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Tain Lee is active.

Publication


Featured researches published by Tain Lee.


Pediatric Radiology | 2006

Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen

BackgroundEchocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions.ObjectiveTo verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease.Materials and methodsOver a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated.ResultsA total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471xa0HU. No obvious beam-hardening artefact was observed.ConclusionThe technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates.


Pediatric Radiology | 2008

Neonatal cardiac multidetector row CT: why and how we do it

I-Chen Tsai; Min-Chi Chen; Sheng-Ling Jan; Chung-Chi Wang; Yun-Ching Fu; Pao-Chun Lin; Tain Lee

Neonatal congenital heart disease is a most difficult area of diagnostic radiology because of the small patient body size and fast resting heart rate. Recently, the spatial and temporal resolution of multidetector-row CT (MDCT) has evolved so that neonatal congenital heart disease can be precisely diagnosed. We describe the role of MDCT in neonatal congenital heart disease and offer tips for the scanning procedure to familiarize radiologists with this developing field.


Pediatric Radiology | 2007

Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

I-Chen Tsai; Tain Lee; Min-Chi Chen; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang

BackgroundMultidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established.ObjectiveTo compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques.Materials and methodsTwelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant.ResultsIn all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery.ConclusionFor neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries.


Pediatric Radiology | 2007

Vertebral and carotid artery anomalies in patients with aberrant right subclavian arteries

I-Chen Tsai; Wen-Sheng Tzeng; Tain Lee; Sheng-Lin Jan; Yun-Ching Fu; Min-Chi Chen; Pao-Chun Lin; Wan-Chun Liao; Clayton Chi-Chang Chen

BackgroundThere is little published evidence regarding the patterns and prevalence of vertebral artery (VA) and common carotid artery (CCA) anomalies in patients with an aberrant right subclavian artery (ARSCA).ObjectiveTo study the patterns and prevalence of VA and CCA anomalies in patients with ARSCA.Materials and methodsIn a 2-year period we reviewed the children referred with suspected vascular ring who had undergone multidetector-row CT. Patients with ARSCA were reviewed for VA and CCA patterns and their prevalence and relevance were calculated.ResultsIn total, 102 patients with ARSCA were identified. VA anomalies were present in 16 patients (15.7%), and CCA anomalies (common carotid trunk) in 21 patients (20.6%). In some patients with VA anomalies, the right VA arose from the right CCA and in some the left VA arose from the aortic arch. When the left VA arose from the aortic arch it was situated between the left CCA and the left SCA or between the left SCA and the ARSCA.ConclusionIf neurointerventionalists understand these potential anomalies and their prevalence, time and contrast medium could be saved when catheterizing the VA and CCA in patients with ARSCA.


American Journal of Roentgenology | 2008

Comprehensive evaluation of ischemic heart disease using MDCT.

I-Chen Tsai; Wen-Lieng Lee; Chen-Rong Tsao; Yen Chang; Min-Chi Chen; Tain Lee; Wan-Chun Liao

OBJECTIVEnRecently MDCT has become widely used for the evaluation of ischemic heart disease, but clinically the evaluation is primarily focused on the coronary artery only. We describe why and how to comprehensively evaluate the cardiac CT scan, including myocardium, motion, viability, valve, and perfusion aspects related to ischemic heart disease.nnnCONCLUSIONnRadiologists should be familiar with the protocol design and comprehensive interpretation of cardiac MDCT to provide comprehensive treatment suggestions for the patients.


American Journal of Roentgenology | 2008

Contrast enhancement in cardiac MDCT: comparison of iodixanol 320 versus iohexol 350.

I-Chen Tsai; Tain Lee; Wei-Lin Tsai; Min-Chi Chen; Ming-Ju Wu; Wen-Lieng Lee; Hui-Ju Ting

OBJECTIVEnThe objective of our study was to evaluate whether iodixanol 320 mg I/mL (iodixanol 320), with the highest iodine concentration of dimeric nonionic contrast agents on the market, results in decreased vascular or myocardial enhancement compared with iohexol 350 mg I/mL (iohexol 350).nnnSUBJECTS AND METHODSnDuring a 4-month period, 72 patients referred for cardiac MDCT were consecutively enrolled and randomized into two groups: iohexol 350 and iodixanol 320. The injection and scanning protocols were the same for both groups. Enhancement of the right heart, left heart, coronary arteries, and left ventricular (LV) myocardium in both the arterial and delayed phases was compared using two-tailed independent Students t test.nnnRESULTSnEnhancement in the right heart, left heart, coronary arteries, and LV myocardium in the arterial phase showed no statistical difference (p > 0.05) between the two groups, although the iohexol group showed slightly higher enhancement (average, 11.2 H) in all of the areas. Surprisingly, in the delayed phase, the iodixanol group displayed significantly higher (7.7 H) persistent enhancement (p < 0.05) in the LV myocardium.nnnCONCLUSIONnIodixanol 320 can provide vascular enhancement in cardiac MDCT that is similar to iohexol 350. In the delayed phase, iodixanol 320 shows significantly higher delayed enhancement (7.7 H) in the LV myocardium than iohexol 350.


American Journal of Roentgenology | 2007

MDCT evaluation after closure of atrial septal defect with an Amplatzer septal occluder.

Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen

OBJECTIVEnThe essay describes the protocol for and interpretation of MDCT scans in the evaluation of patients after insertion of an Amplatzer septal occluder.nnnCONCLUSIONnIn anatomic regions that cannot be confidently evaluated with transthoracic echocardiography, MDCT is useful for evaluating Amplatzer septal occluders for protrusion, migration, and residual shunt. Radiologists should be familiar with the imaging protocol and interpretation.


American Journal of Roentgenology | 2007

Gradual Pulmonary Artery Enhancement: New Sign of Septal Defects on CT

I-Chen Tsai; Tain Lee; Min-Chi Chen; Yun-Ching Fu; Sheng-Lin Jan; Wei-Lin Tsai; Chung-Chi Wang

OBJECTIVEnHemodynamic information observed on serial images obtained with bolus tracking might help in diagnosing septal defects on CT. Our purpose was to qualitatively and quantitatively examine a new sign called gradual pulmonary artery enhancement.nnnCONCLUSIONnGradual pulmonary artery enhancement is a newly recognized CT sign that may be helpful in evaluating septal defects.


中華放射線醫學雜誌 | 2010

Kommerell Diverticulum: A Five Year Incidence and Morphology Study Using Computed Tomography

Hsin-Yu Tsai; Wei-Lin Tsai; I-Chen Tsai; Yen-Tin Lin; Tain Lee; Min-Chi Chen; Clayton Chi-Chang Chen


中華放射線醫學雜誌 | 2008

Imaging Characteristics of Thymomas on Chest CT Classified by the 2004 WHO Classification

Yen-Ting Lin; I-Chen Tsai; Clayton Chi-Chang Chen; Tain Lee

Collaboration


Dive into the Tain Lee's collaboration.

Top Co-Authors

Avatar

I-Chen Tsai

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Min-Chi Chen

Central Taiwan University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Yun-Ching Fu

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Chung-Chi Wang

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Sheng-Lin Jan

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Wan-Chun Liao

Central Taiwan University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Yen Chang

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Clayton Chi-Chang Chen

Central Taiwan University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Wei-Lin Tsai

National Yang-Ming University

View shared research outputs
Top Co-Authors

Avatar

Pao-Chun Lin

Central Taiwan University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge