Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Takeshi Machino is active.

Publication


Featured researches published by Takeshi Machino.


Heart Rhythm | 2013

Concomitant obstructive sleep apnea increases the recurrence of atrial fibrillation following radiofrequency catheter ablation of atrial fibrillation: clinical impact of continuous positive airway pressure therapy.

Yoshihisa Naruse; Hiroshi Tada; Makoto Satoh; Mariko Yanagihara; Hidekazu Tsuneoka; Yumi Hirata; Yoko Ito; Kenji Kuroki; Takeshi Machino; Hiro Yamasaki; Miyako Igarashi; Yukio Sekiguchi; Akira Sato; Kazutaka Aonuma

BACKGROUND Recent studies have suggested an emerging link between obstructive sleep apnea (OSA) and atrial fibrillation (AF). Patients with OSA are less likely to remain in sinus rhythm after radiofrequency catheter ablation of AF. OBJECTIVE To evaluate the efficacy of appropriate treatment with continuous positive airway pressure (CPAP) on recurrences of AF after ablation. METHODS This study prospectively included 153 patients (128 men; 60 ± 9 years) who underwent extensive encircling pulmonary vein isolation for drug refractory AF. The standard overnight polysomnographic evaluation was performed 1 week after ablation, and the total duration and the number of central or obstructive sleep apnea or hypopnea episodes were examined. RESULTS Of 153 patients, 116 patients were identified as having OSA. Data regarding the use of CPAP and recurrences of AF were obtained in 82 patients. The remaining 34 patients with OSA were defined as the no-CPAP group. Polysomnography revealed no sleep-disordered breathing in 37 patients. During a mean follow-up period of 18.8 ± 10.3 months, 51 (33%) patients experienced AF recurrences after ablation. A Cox regression analysis revealed that the left atrial volume (hazard ratio [HR] 1.11; 95% confidence interval [CI] 1.01-1.23; P<.05), concomitant OSA (HR 2.61; 95% CI 1.12-6.09; P<.05), and usage of CPAP therapy (HR 0.41; 95% CI 0.22-0.76; P<.01) were associated with AF recurrences during the follow-up period. CONCLUSIONS Patients with untreated OSA have a higher recurrence of AF after ablation. Appropriate treatment with CPAP in patients with OSA is associated with a lower recurrence of AF.


Journal of the American College of Cardiology | 2010

Prevention of atrial fibrillation recurrence with corticosteroids after radiofrequency catheter ablation: a randomized controlled trial.

Takashi Koyama; Hiroshi Tada; Yukio Sekiguchi; Takanori Arimoto; Hiro Yamasaki; Kenji Kuroki; Takeshi Machino; Kazuko Tajiri; Xu Dong Zhu; Aiko Sugiyasu; Keisuke Kuga; Yoshio Nakata; Kazutaka Aonuma

OBJECTIVES We sought to clarify the efficacy of corticosteroid therapy for preventing atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI). BACKGROUND The inflammatory process may cause acute AF recurrence after PVI. However, no studies have examined the relationship between corticosteroid administration and AF recurrence after PVI. METHODS A total of 125 patients with paroxysmal AF were randomized to receive either corticosteroids (corticosteroid group) or a placebo (placebo group). In the corticosteroid group, intravenous hydrocortisone (2 mg/kg) was given the day of the procedure, and oral prednisolone (0.5 mg/kg/day) was administered for 3 days after the PVI. The body temperature and high-sensitivity C-reactive protein level were measured before and on each of the first 3 days after ablation. RESULTS The prevalence of immediate AF recurrence (≤3 days after the PVI) was significantly lower in the corticosteroid group (7%) than in the placebo group (31%). The maximum body temperature and C-reactive protein during the initial 3 days after ablation and the increase in the body temperature and C-reactive protein level from baseline were significantly lower in the corticosteroid group than in the placebo group. Corticosteroid treatment did not decrease AF recurrences between 4 and 30 days after ablation. The AF-free rate at 14 months post-ablation was greater in the corticosteroid group (85%) than in the placebo group (71%, p=0.032 by the log-rank test). CONCLUSIONS Transient use of small amounts of corticosteroids shortly after AF ablation may be effective and safe for preventing not only immediate AF recurrences but also AF recurrences during the mid-term follow-up period after PVI.


American Journal of Cardiology | 2009

Comparison of Characteristics and Significance of Immediate Versus Early Versus No Recurrence of Atrial Fibrillation After Catheter Ablation

Takashi Koyama; Yukio Sekiguchi; Hiroshi Tada; Takanori Arimoto; Hiro Yamasaki; Kenji Kuroki; Takeshi Machino; Kazuko Tajiri; Xu Dong Zhu; Miyako Kanemoto; Aiko Sugiyasu; Keisuke Kuga; Kazutaka Aonuma

Atrial fibrillation (AF) recurrences after catheter ablation are common within the first month after AF ablation, and inflammatory processes may be related to AF genesis. This study aimed to clarify the relation between inflammatory processes and recurrence of AF after ablation and to characterize AF recurring within 3 days after ablation (immediate AF recurrence).The study included 186 patients with drug-refractory paroxysmal AF who underwent extensive pulmonary vein isolation. Body temperature and C-reactive protein level were measured before and consecutively on the first 3 days after ablation. Signs of pericarditis or atrial arrhythmias within 3 days after ablation were also monitored. Forty-five patients (24%) had immediate AF recurrence (immediate-AF-recurrence group), 27 (14%) had early recurrence 4 to 30 days after ablation (early-AF-recurrence group), and the remaining 114 (61%) had no AF recurrence within 1 month after ablation (no-AF-recurrence group). Increases in body temperature and C-reactive protein level from baseline in the immediate-AF-recurrence group were the highest among the 3 groups, and signs of pericarditis were observed in 15 of the 45 patients (33%) in the immediate-AF-recurrence group. Atrial premature contractions and nonsustained AF occurred most frequently in the early-AF-recurrence group. After 6-month follow-up, the AF-free rate was greater in the immediate-AF-recurrence group (76%) than in the early-AF-recurrence group (30%). In conclusion, immediate AF recurrence has an apparently different mechanism and impact on midterm outcomes than does early AF recurrence. Acute inflammatory changes after ablation may be responsible for immediate AF recurrence.


Journal of Cardiovascular Electrophysiology | 2011

Left Atrial Stiffness Relates to Left Ventricular Diastolic Dysfunction and Recurrence After Pulmonary Vein Isolation for Atrial Fibrillation

Tomoko Machino-Ohtsuka; Yoshihiro Seo; Hiroshi Tada; Tomoko Ishizu; Takeshi Machino; Hiro Yamasaki; Miyako Igarashi; Dongzhu Xu; Yukio Sekiguchi; Kazutaka Aonuma

Left Atrial Stiffness and Atrial Fibrillation. Introduction: An increased left atrial (LA) stiffness reflects the structural remodeling and deterioration of the LA function. This study was designed to estimate LA stiffness by measuring a combination of the strain and LA pressure in patients undergoing pulmonary vein isolation (PVI) of atrial fibrillation (AF) and to evaluate the influence of the LA stiffness on the cardiac function, serum markers, and recurrence of AF after PVI.


Heart Rhythm | 2011

Concomitant chronic kidney disease increases the recurrence of atrial fibrillation after catheter ablation of atrial fibrillation: A mid-term follow-up

Yoshihisa Naruse; Hiroshi Tada; Yukio Sekiguchi; Takeshi Machino; Mahito Ozawa; Hiro Yamasaki; Miyako Igarashi; Kenji Kuroki; Yoko Itoh; Nobuyuki Murakoshi; Iwao Yamaguchi; Kazutaka Aonuma

BACKGROUND Chronic kidney disease (CKD) is often associated with atrial fibrillation (AF). However, its impact on the results of radiofrequency catheter ablation for AF has not been fully examined. OBJECTIVE The purpose of this study was to clarify the relationship between CKD and postcatheter ablation AF recurrence. METHODS The study included 221 patients with AF who underwent successful catheter ablation. The prevalence and characteristics of AF recurrences were determined. CKD was defined as an estimated glomerular filtration rate <60 mL/min/1.73 m(2). RESULTS After mean follow-up of 31.9 ± 7.6 months, 87 (39%) patients had AF recurrences. Multivariate Cox regression analysis revealed that CKD (hazard ratio [HR] 2.089, 95% confidence interval [CI] 1.292-3.378, P <.01) and left atrial volume (HR 1.009, 95% CI 1.002-1.017, P <.05) were independent predictors of AF recurrences. Among the 221 patients, 54 (24.4%) had CKD. Patients with CKD had a higher incidence of AF recurrences (57.4%) compared to the non-CKD patients (33.5%, P <.01). Compared with patients without CKD, patients with CKD were older (64 ± 11 years vs 58 ± 10 years, P <.001) and had a higher prevalence of hypertension (72% vs 53%, P <.05), larger left atrial volume (74.7 ± 29.4 mL vs 62.0 ± 26.0 mL, P <.01), and higher plasma B-type natriuretic peptide levels (129.6 ± 209.3 pg/mL vs 68.8 ± 91.0 pg/mL, P <.01). CONCLUSION The presence of CKD increased the risk of AF recurrences after catheter ablation. Multifactorial physiologic factors due to CKD may account for the higher prevalence of recurrent AF in patients with CKD than in those without.


Heart Rhythm | 2011

Prevalence and characteristics of asymptomatic excessive transmural injury after radiofrequency catheter ablation of atrial fibrillation.

Hiro Yamasaki; Hiroshi Tada; Yukio Sekiguchi; Miyako Igarashi; Takanori Arimoto; Takeshi Machino; Mahito Ozawa; Yoshihisa Naruse; Kenji Kuroki; Hidekazu Tsuneoka; Yoko Ito; Nobuyuki Murakoshi; Keisuke Kuga; Ichinosuke Hyodo; Kazutaka Aonuma

BACKGROUND Even with a low energy setting, radiofrequency energy applications on the left atrial (LA) posterior wall may cause excessive transmural injury (ETI) during catheter ablation of atrial fibrillation (AF). OBJECTIVE The purpose of this study was to clarify the prevalence and characteristics of ETI. METHODS This study included 104 patients with AF who underwent extensive encircling pulmonary vein isolation (EEPVI) followed by an endoscopic examination (≤48 hours after EEPVI). EEPVI was performed under conscious sedation, and the ablation settings at the LA posterior wall were a maximum energy of 20 to 25 W and duration of ≤30 seconds. The ETI was defined as any injury that resulted from EEPVI, including esophageal damage or periesophageal nerve injury. RESULTS ETIs were found in 10 (9.6%) patients and were all asymptomatic; esophageal damage in 4 patients and periesophageal nerve injury in the remaining 6. All patients with ETI were below normal weight (body mass index [BMI] < 24.9 kg/m(2)), and consisted of 17% of those below normal weight. The procedural parameters such as the type of energy source, total duration of energy applications to the LA posterior wall, additional LA linear ablation, and biochemical markers were not related to the ETI. In the logistic multiadjusted model, the BMI (per 1 kg/m(2)) was the only independent predictor of ETI (odds ratio = 0.76; 95% confidence interval = 0.59 to 0.97, P < .05). CONCLUSION Asymptomatic ETIs were not rare even with a low energy setting in patients below normal weight. Tailored energy settings based on the patients BMI may be required when performing EEPVI.


Circulation-arrhythmia and Electrophysiology | 2014

Systematic Treatment Approach to Ventricular Tachycardia in Cardiac Sarcoidosis

Yoshihisa Naruse; Yukio Sekiguchi; Akihiko Nogami; Hiroyuki Okada; Yasuteru Yamauchi; Takeshi Machino; Kenji Kuroki; Yoko Ito; Hiro Yamasaki; Miyako Igarashi; Hiroshi Tada; Junichi Nitta; Dongzhu Xu; Akira Sato; Kazutaka Aonuma

Background—Fatal arrhythmia is commonly observed in cardiac sarcoidosis, but clinical effects of a systematic treatment approach are still uncertain. This study sought to describe both clinical and electrophysiological characteristics and outcomes of systematic treatment approach to ventricular tachycardia (VT) associated with cardiac sarcoidosis. Methods and Results—We enrolled 37 consecutive patients (11 men; age, 56±11 years) with a diagnosis of sustained VT associated with cardiac sarcoidosis. Clinical effects of a systematic treatment approach including medical therapy (both steroid and antiarrhythmic agents), in association with radiofrequency catheter ablation, were evaluated. All patients received antiarrhythmic agents, and 34 received steroid therapy. During a 39-month follow-up, 23 (62%) patients were free from any VT episodes with medical therapy. Multivariable Cox regression analyses revealed that the absence of gallium-67 myocardial uptake was an independent predictor for VT recurrence (hazard ratio, 7.51; 95% confidence interval, 1.65–34.26; P<0.01). Fourteen patients who experienced VT recurrences even while on drug therapy underwent radiofrequency catheter ablation. Electrophysiological study revealed that the mechanisms of VTs could be classified into 2 subgroups: Purkinje-related or scar-related VT. The QRS duration of VT was narrower in Purkinje-related than in scar-related VTs (157±23 versus 183±22 ms; P<0.05). After a 33-month follow-up subsequent to the radiofrequency catheter ablation, 6 of 14 patients experienced VT recurrence. The number of VTs sustained during electrophysiological study was higher in the patients with VT recurrence than in those without (3.7±1.4 versus 1.9±0.8; P<0.01). Conclusions—A systematic treatment approach to cardiac sarcoidosis with VT successfully suppressed VT recurrences in the majority of patients studied.


Journal of Cardiovascular Electrophysiology | 2011

High Washout Rate of Iodine-123-Metaiodobenzylguanidine Imaging Predicts the Outcome of Catheter Ablation of Atrial Fibrillation

Takanori Arimoto; Hiroshi Tada; Miyako Igarashi; Yukio Sekiguchi; Akira Sato; Takashi Koyama; Hiro Yamasaki; Takeshi Machino; Kenji Kuroki; Keisuke Kuga; Kazutaka Aonuma

123 I‐MIBG and Ablation for Atrial Fibrillation. Introduction: Excessive sympathetic nervous activity may contribute to atrial fibrillation (AF) recurrences after ablation, but its precise role remains controversial. The goals of this study were to assess the effects of AF on the iodine‐123‐metaiodobenzylguanidine (123I‐MIBG) findings and to elucidate its impact on the procedural outcome in patients undergoing a first‐time catheter ablation to treat AF.


American Journal of Cardiology | 2013

Effect of eplerenone on maintenance of sinus rhythm after catheter ablation in patients with long-standing persistent atrial fibrillation.

Yoko Ito; Hiro Yamasaki; Yoshihisa Naruse; Kentaro Yoshida; Takashi Kaneshiro; Nobuyuki Murakoshi; Miyako Igarashi; Kenji Kuroki; Takeshi Machino; Dongzhu Xu; Fusanori Kunugita; Yukio Sekiguchi; Akira Sato; Hiroshi Tada; Kazutaka Aonuma

Several studies have demonstrated a relation between the rennin-angiotensin-aldosterone system and atrial fibrillation (AF), but there are no reports on the effect of eplerenone, a selective aldosterone blocker, on the prevention of AF recurrence after radiofrequency catheter ablation (RFCA). The aim of this study was to evaluate the effects of eplerenone on clinical outcomes after RFCA in patients with long-standing persistent AF. A total of 161 consecutive patients with long-standing persistent AF (sustained AF duration 1 to 20 years, mean 3.4 ± 3.8) who underwent RFCA were investigated. Eplerenone was used in 55 patients and not used in the remaining 106 patients. Other conventional pharmacologic agents, including angiotensin-converting enzyme inhibitors or angiotensin type 1 receptor blockers, were used equally in the 2 groups. After 24 months of follow-up, 47% of the patients were free from AF recurrence. The rate of freedom from AF recurrence was significantly greater in the eplerenone group (60%) than in the noneplerenone group (40%) (p = 0.011). By univariate analysis, the duration of sustained AF (p <0.001), left atrial diameter (p = 0.010), left atrial volume index (p = 0.017), and early AF recurrence (p <0.001) were significantly associated with AF recurrence, and the use of eplerenone was associated with maintenance of sinus rhythm after RFCA (p = 0.022). Multivariate Cox regression analysis showed that longer duration of sustained AF (>3 years) (p <0.001) and early AF recurrence (p <0.001) were significantly associated with AF recurrence, and only eplerenone therapy significantly improved maintenance of sinus rhythm (p = 0.017). In conclusion, eplerenone significantly improved maintenance of sinus rhythm after RFCA in patients with long-standing persistent AF.


American Journal of Cardiology | 2010

Effect of Restoration of Sinus Rhythm by Extensive Antiarrhythmic Drugs in Predicting Results of Catheter Ablation of Persistent Atrial Fibrillation

Miyako Igarashi; Hiroshi Tada; Yukio Sekiguchi; Hiro Yamasaki; Takanori Arimoto; Kenji Kuroki; Takeshi Machino; Nobuyuki Murakoshi; Kazutaka Aonuma

In patients with persistent atrial fibrillation (AF), an extensive antiarrhythmic drug (AAD) therapy using class III AADs and class I AADs might be more effective in restoring sinus rhythm than class I or III AADs alone. However, the significance and efficacy of this treatment before radiofrequency catheter ablation is unclear. The present study included 51 consecutive patients with long-lasting persistent AF (>12 months) in whom > or =2 previous AADs had failed to restore sinus rhythm (SR). Before performing extensive pulmonary vein isolation, extensive AAD therapy for >3 months was attempted. Before ablation, AF had converted to SR in 33 patients (65%; SR group) and had continued in 18 (35%; AF group). The left ventricular ejection fraction had increased (p <0.01) in association with the improved left atrial diameter (p <0.05) and brain natriuretic peptide plasma level (p <0.001) in the SR group. However, these parameters had not improved in the AF group. The AF-free rate without any AADs at 14 months after a single ablation procedure was greater in the SR group (61%) than in the AF group (22%; hazard ratio 2.62, 95% confidence interval 1.22 to 5.63; p = 0.013). No restoration of SR with extensive AAD therapy (odds ratio 4.493, 95% confidence interval 1.143 to 17.658; p <0.05) and sustained AF lasting for >3 years (odds ratio 4.574, 95% confidence interval 1.027 to 20.368; p <0.05) before ablation were associated with AF recurrence after ablation. In conclusion, restoration of SR with improved cardiac function and structural remodeling after extensive AAD therapy might predict favorable outcomes after ablation in patients with long-lasting, persistent AF.

Collaboration


Dive into the Takeshi Machino's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge