Takkan Morishima
Aichi Medical University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Takkan Morishima.
Journal of Arthroplasty | 2014
Takkan Morishima; Bastiaan Ginsel; Godwin G.H. Choy; Lance J. Wilson; Sarah L. Whitehouse; Ross Crawford
In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available. We investigated the torque to periprosthetic femoral fracture of the Exeter short stem compared with the conventional length Exeter stem in a Sawbone model. Forty-two stems; 21 shorter and 21 conventional stems both with three different offsets were cemented in a composite Sawbone model and torqued to fracture. Results showed that Sawbone femurs break at a statistically significantly lower torque to failure with a shorter compared to conventional-length Exeter stem of the same offset. Both standard and short-stem designs are safe to use as the torque to failure is 7-10 times that seen in activities of daily living.
Internal Medicine | 2016
Junko Takagi; Hiroyuki Morita; Kiyoaki Ito; Tomohiko Ohashi; Sho Hirase; Tatsuo Ito; Takkan Morishima; Kazuo Otake; Masashi Yoneda
Adefovir dipivoxil (ADV) is effective for hepatitis B virus (HBV) infection; however, ADV may provoke renal injury resulting in osteomalacia, and this side effect is seldom recognized until bone fractures emerge. We herein present a 66-year-old woman with HBV infection who received ADV for 6 years. Although she exhibited no sign of bone fractures, her urinary β-2 microglobulin (β2MG) level increased to 83,837 μg/L and scintigraphy revealed minimal fractures of the third rib. ADV was subsequently reduced and her urinary β2MG rapidly fell to 3,637 μg/L. Conversely, her urinary N-acetyl-β-D-glucosaminidase, and serum phosphate, alkaline phosphatase levels did not respond.
Journal of orthopaedic surgery | 2014
Takkan Morishima; Godwin G.H. Choy; Ross Crawford; Lance J. Wilson
Purpose. To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. Methods. Two groups of 5 synthetic femurs were used, and 6 pressure sensors were placed in the femur at 20-mm intervals proximally to distally. Cement was filled into the femoral canal retrogradely using a cement gun with either the half-moon pressuriser or the femoral canal pressuriser. Maximum pressures and pressure time integrals (cumulative pressure over time) of the 2 pressurisers were compared. Results. At all sensors, the half-moon pressuriser produced higher maximum pressures and pressure time integrals than the femoral canal pressuriser, but the difference was significant only at sensor 1 (proximal femur). This may result in reduced cement interdigitation in the proximal femur. Conclusion. The half-moon pressuriser produced higher maximum cementation pressures and pressure time integrals than the femoral canal pressuriser in the proximal femur region, which is critical for rotational stability of the implant and prevention of implant fracture.
Journal of Orthopaedic Science | 2011
Shiro Hirose; Hiromi Otsuka; Takkan Morishima; Keiji Sato
Journal of Orthopaedic Science | 2012
Shiro Hirose; Hiromi Otsuka; Takkan Morishima; Keiji Sato
Journal of Orthopaedic Science | 2011
Haruhiko Akiyama; Takkan Morishima; Mitsuru Takemoto; Koji Yamamoto; Hiromi Otsuka; Toshiki Iwase; Tamon Kabata; Tsunemitsu Soeda; Keiichi Kawanabe; Keiji Sato; Takashi Nakamura
Institute of Health and Biomedical Innovation; Science & Engineering Faculty | 2015
Bastiaan Ginsel; Takkan Morishima; Lance J. Wilson; Sarah L. Whitehouse; Ross Crawford
Science & Engineering Faculty | 2014
Takkan Morishima; Godwin G.H. Choy; Ross Crawford; Lance J. Wilson
Institute of Health and Biomedical Innovation; Science & Engineering Faculty | 2014
Takkan Morishima; Bastiaan Ginsel; Godwin G.H. Choy; Lance J. Wilson; Sarah L. Whitehouse; Ross Crawford
Journal of Bone and Joint Surgery-british Volume | 2013
Takkan Morishima; Bastiaan Ginsel; Godwin G.H. Choy; Lance J. Wilson; Sarah L. Whitehouse; Ross Crawford