Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Tanvir Bajwa is active.

Publication


Featured researches published by Tanvir Bajwa.


The New England Journal of Medicine | 2008

Long-Term Results of Carotid Stenting versus Endarterectomy in High-Risk Patients

Hitinder S. Gurm; Jay S. Yadav; Pierre Fayad; Barry T. Katzen; Gregory Mishkel; Tanvir Bajwa; Gary M. Ansel; Neil E. Strickman; Hong Wang; Sidney Cohen; Joseph M. Massaro; Donald E. Cutlip

BACKGROUND We previously reported that, in a randomized trial, carotid stenting with the use of an emboli-protection device is not inferior to carotid endarterectomy for the treatment of carotid artery disease at 30 days and at 1 year. We now report the 3-year results. METHODS The trial evaluated carotid artery stenting with the use of an emboli-protection device as compared with endarterectomy in 334 patients at increased risk for complications from endarterectomy who had either a symptomatic carotid artery stenosis of at least 50% of the luminal diameter or an asymptomatic stenosis of at least 80%. The prespecified major secondary end point at 3 years was a composite of death, stroke, or myocardial infarction within 30 days after the procedure or death or ipsilateral stroke between 31 days and 1080 days (3 years). RESULTS At 3 years, data were available for 260 patients (77.8%), including 85.6% of patients in the stenting group and 70.1% of those in the endarterectomy group. The prespecified major secondary end point occurred in 41 patients in the stenting group (cumulative incidence, 24.6%; Kaplan-Meier estimate, 26.2%) and 45 patients in the endarterectomy group (cumulative incidence, 26.9%; Kaplan-Meier estimate, 30.3%) (absolute difference in cumulative incidence for the stenting group, -2.3%; 95% confidence interval, -11.8 to 7.0). There were 15 strokes in each of the two groups, of which 11 in the stenting group and 9 in the endarterectomy group were ipsilateral. CONCLUSIONS In our trial of patients with severe carotid artery stenosis and increased surgical risk, no significant difference could be shown in long-term outcomes between patients who underwent carotid artery stenting with an emboli-protection device and those who underwent endarterectomy. (ClinicalTrials.gov number, NCT00231270 [ClinicalTrials.gov].).


Journal of the American College of Cardiology | 2012

Acute and 12-Month Results With Catheter-Based Mitral Valve Leaflet Repair : The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study

Patrick L. Whitlow; Ted Feldman; Wes R. Pedersen; D. Scott Lim; Robert Kipperman; Richard W. Smalling; Tanvir Bajwa; Howard C. Herrmann; John M. Lasala; James T. Maddux; Murat Tuzcu; Samir Kapadia; Alfredo Trento; Robert J. Siegel; Elyse Foster; Donald D. Glower; Laura Mauri; Saibal Kar

OBJECTIVES The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study (HRS) assessed the safety and effectiveness of the MitraClip device (Abbott Vascular, Santa Clara, California) in patients with significant mitral regurgitation (MR) at high risk of surgical mortality rate. BACKGROUND Patients with severe MR (3 to 4+) at high risk of surgery may benefit from percutaneous mitral leaflet repair, a potentially safer approach to reduce MR. METHODS Patients with severe symptomatic MR and an estimated surgical mortality rate of ≥12% were enrolled. A comparator group of patients screened concurrently but not enrolled were identified retrospectively and consented to compare survival in patients treated by standard care. RESULTS Seventy-eight patients underwent the MitraClip procedure. Their mean age was 77 years, >50% had previous cardiac surgery, and 46 had functional MR and 32 degenerative MR. MitraClip devices were successfully placed in 96% of patients. Protocol-predicted surgical mortality rate in the HRS and concurrent comparator group was 18.2% and 17.4%, respectively, and Society of Thoracic Surgeons calculator estimated mortality rate was 14.2% and 14.9%, respectively. The 30-day procedure-related mortality rate was 7.7% in the HRS and 8.3% in the comparator group (p = NS). The 12-month survival rate was 76% in the HRS and 55% in the concurrent comparator group (p = 0.047). In surviving patients with matched baseline and 12-month data, 78% had an MR grade of ≤2+. Left ventricular end-diastolic volume improved from 172 ml to 140 ml and end-systolic volume improved from 82 ml to 73 ml (both p = 0.001). New York Heart Association functional class improved from III/IV at baseline in 89% to class I/II in 74% (p < 0.0001). Quality of life was improved (Short Form-36 physical component score increased from 32.1 to 36.1 [p = 0.014] and the mental component score from 45.5 to 48.7 [p = 0.065]) at 12 months. The annual rate of hospitalization for congestive heart failure in surviving patients with matched data decreased from 0.59 to 0.32 (p = 0.034). CONCLUSIONS The MitraClip device reduced MR in a majority of patients deemed at high risk of surgery, resulting in improvement in clinical symptoms and significant left ventricular reverse remodeling over 12 months. (Pivotal Study of a Percutaneous Mitral Valve Repair System [EVEREST II]; NCT00209274).


Catheterization and Cardiovascular Interventions | 2002

Prospective randomized study of N-acetylcysteine, fenoldopam, and saline for prevention of radiocontrast-induced nephropathy

Suhail Allaqaband; Ramagopal Tumuluri; Ahmed M. Malik; Anjan Gupta; Paul Volkert; Yoseph Shalev; Tanvir Bajwa

The objective of this study was to compare the efficacy of N‐acetylcysteine (NAC), fenoldopam, and saline in preventing radiocontrast‐induced nephropathy (RCIN) in high‐risk patients undergoing cardiovascular procedures. We prospectively enrolled 123 patients who were scheduled for cardiovascular procedures and had a baseline creatinine > 1.6 mg/dl or creatinine clearance of < 60 ml/min. Patients were randomly assigned to receive either saline (0.45% normal saline at 1 cc/kg) for 12 hr before and 12 hr after the procedure, or fenoldopam (0.1 μg/kg/min) plus saline for 4 hr prior and 4 hr after the procedure, or NAC orally (600 mg) plus saline every 12 hr for 24 hr prior and 24 hr after the procedure. All the patients received low‐osmolality nonionic contrast. RCIN was defined as an increase in creatinine level > 0.5 mg/dl after 48 hr. The incidence of RCIN was 17.7% in the NAC group, 15.3% in the saline group, and 15.7% in the fenoldopam group (P = 0.919). Of the 20 patients who developed RCIN, 2 required dialysis. Serum creatinine decreased after 48 hr (vs. baseline) in 38% patients in the NAC group, 18% in the fenoldopam group, and 15% in the saline group. In patients with chronic renal insufficiency, NAC or fenoldopam offered no additional benefit over hydration with saline in preventing RCIN. Cathet Cardiovasc Intervent 2002;57:279–283.


Journal of the American College of Cardiology | 2014

Percutaneous Mitral Valve Repair for Mitral Regurgitation in High-Risk Patients: Results of the EVEREST II Study

Donald D. Glower; Saibal Kar; Alfredo Trento; D. Scott Lim; Tanvir Bajwa; Ramon Quesada; Patrick L. Whitlow; Michael J. Rinaldi; Paul A. Grayburn; Michael J. Mack; Laura Mauri; Patrick M. McCarthy; Ted Feldman

BACKGROUND The EVEREST II (Endovascular Valve Edge-to-Edge REpair STudy) High-Risk registry and REALISM Continued Access Study High-Risk Arm are prospective registries of patients who received the MitraClip device (Abbott Vascular, Santa Clara, California) for mitral regurgitation (MR) in the United States. OBJECTIVES The purpose of this study was to report 12-month outcomes in high-risk patients treated with the percutaneous mitral valve edge-to-edge repair. METHODS Patients with grades 3 to 4+ MR and a surgical mortality risk of ≥12%, based on the Society of Thoracic Surgeons risk calculator or the estimate of a surgeon coinvestigator following pre-specified protocol criteria, were enrolled. RESULTS In the studies, 327 of 351 patients completed 12 months of follow-up. Patients were elderly (76 ± 11 years of age), with 70% having functional MR and 60% having prior cardiac surgery. The mitral valve device reduced MR to ≤2+ in 86% of patients at discharge (n = 325; p < 0.0001). Major adverse events at 30 days included death in 4.8%, myocardial infarction in 1.1%, and stroke in 2.6%. At 12 months, MR was ≤2+ in 84% of patients (n = 225; p < 0.0001). From baseline to 12 months, left ventricular (LV) end-diastolic volume improved from 161 ± 56 ml to 143 ± 53 ml (n = 203; p < 0.0001) and LV end-systolic volume improved from 87 ± 47 ml to 79 ± 44 ml (n = 202; p < 0.0001). New York Heart Association functional class improved from 82% in class III/IV at baseline to 83% in class I/II at 12 months (n = 234; p < 0.0001). The 36-item Short Form Health Survey physical and mental quality-of-life scores improved from baseline to 12 months (n = 191; p < 0.0001). Annual hospitalization rate for heart failure fell from 0.79% pre-procedure to 0.41% post-procedure (n = 338; p < 0.0001). Kaplan-Meier survival estimate at 12 months was 77.2%. CONCLUSIONS The percutaneous mitral valve device significantly reduced MR, improved clinical symptoms, and decreased LV dimensions at 12 months in this high-surgical-risk cohort. (Endovascular Valve Edge-to-Edge REpair STudy [EVERESTIIRCT]; NCT00209274).


Journal of Vascular and Interventional Radiology | 2013

Heparin-bonded, Expanded Polytetrafluoroethylene-lined Stent Graft in the Treatment of Femoropopliteal Artery Disease: 1-Year Results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) Trial

Richard R. Saxon; Arun Chervu; Paul A. Jones; Tanvir Bajwa; Dennis Gable; Peter Soukas; Richard J. Begg; John G. Adams; Gary M. Ansel; Darren B. Schneider; Charles M. Eichler; Michael Rush

PURPOSE To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. MATERIALS AND METHODS In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. RESULTS At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. CONCLUSIONS The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes.


Catheterization and Cardiovascular Interventions | 2008

Stent fracture, an incidental finding or a significant marker of clinical in-stent restenosis?

Fareed Shaikh; Rajesh Maddikunta; Mohamed Djelmami-Hani; Joaquin Solis; Suhail Allaqaband; Tanvir Bajwa

The predictors and clinical significance for stent fracture (SF) in drug‐eluting stents (DES) remain unknown. We identified procedural factors leading to SF and its clinical consequences in DES.


Catheterization and Cardiovascular Interventions | 2010

“The chimney graft”—A simple technique for endovascular repair of complex juxtarenal abdominal aortic aneurysms in no‐option patients

Suhail Allaqaband; M. Fuad Jan; Tanvir Bajwa

Endovascular aneurysm repair (EVAR) has developed as a less invasive alternative to open surgery for patients with abdominal aortic aneurysms. However, patients with very short infrarenal necks require complex surgical open repair, which is associated with increased mortality and morbidity. The risk of complex open repair may be prohibitive in high‐risk patients. Thus, modifying the technique of EVAR may be required in such patients to successfully exclude aneurysms. An alternative that can be used in these patients is the so‐called “chimney graft” technique. We report two cases where the chimney graft technique was used with good immediate results.


Journal of Cardiovascular Electrophysiology | 1994

Ablation of left free-wall accessory pathways using radiofrequency energy at the atrial insertion site: transseptal versus transaortic approach

Sanjay Deshpande; Siobhan Bremner; Jasbir Sra; Anwer Dhala; Zalmen Blanck; Tanvir Bajwa; Issam Al‐Bitar; Rami Gal; Joseph S. Sarnoski; Masood Akhtar; Mohammad Jazayeri

Transseptal versus Transaortic Ablation. Introduction: Transcatheter ablation of the left free‐wall atrioventricular accessory pathways (AP) by delivery of radiofrequency current at the ventricular insertion site has been shown to be effective. The efficacy of such a technique targeting the atrial insertion site of the AP was evaluated.


Catheterization and Cardiovascular Interventions | 2003

Endovascular intervention of aortoiliac occlusive disease in high‐risk patients using the kissing stents technique: Long‐term results

Mouatou Mouanoutoua; Rajesh Maddikunta; Suhail Allaqaband; Anjan Gupta; Yoseph Shalev; Ramagopal Tumuluri; Tanvir Bajwa

Endovascular intervention deploying a kissing stents (KS) technique has been used as an alternative to surgical intervention in treating symptomatic aortoiliac occlusive disease. However, the long‐term results on high‐risk patients are unknown. We retrospectively analyzed data on high‐risk patients who underwent endovascular intervention using the KS technique at our institution. Fifty high‐risk patients aged 62 ± 6.4 years with severe aortoiliac stenosis underwent stent‐supported angioplasty using the KS technique. Thirty percent of the patients had total occlusion of the distal aorta and/or the iliac arteries. Twelve patients received thrombolytics prior to stenting. The procedure was successful in all 50 patients. There was a 4% acute complication rate (distal embolization). However, there were no vascular complications, myocardial infarction, or perioperative death. Primary patency during follow‐up of 20 ± 12.3 months was 92%, while secondary patency rate was 100%. Amputation‐free survival was 100%. Ninety‐two percent remained free of lifestyle‐limiting claudication.Catheter Cardiovasc Interv 2003;60:320–326.© 2003 Wiley‐Liss, Inc.


Catheterization and Cardiovascular Interventions | 2006

A case of popliteal stent fracture with pseudoaneurysm formation.

Joaquin Solis; Suhail Allaqaband; Tanvir Bajwa

We describe a case of angiographically documented stent fracture and pseudoaneurysm formation in a patient with femoropopliteal disease, which was successfully treated with deployment of an endovascular stent graft. Technical aspects of the procedure are discussed and the experience with stent fractures previously reported in the literature is reviewed.

Collaboration


Dive into the Tanvir Bajwa's collaboration.

Top Co-Authors

Avatar

Suhail Allaqaband

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Anjan Gupta

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Bijoy K. Khandheria

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

M. Fuad Jan

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Naoyo Mori

University of Wisconsin–Milwaukee

View shared research outputs
Top Co-Authors

Avatar

Donald H. Schmidt

University of Wisconsin–Milwaukee

View shared research outputs
Top Co-Authors

Avatar

Yoseph Shalev

University of Wisconsin–Milwaukee

View shared research outputs
Top Co-Authors

Avatar

Ted Feldman

NorthShore University HealthSystem

View shared research outputs
Top Co-Authors

Avatar

Mark W. Mewissen

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge