Tao Shiyang
Electric Power Research Institute
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Tao Shiyang.
china international conference on electricity distribution | 2016
Tao Shiyang; Cheng Xu; Duan Dapeng; Ye Huisheng; Bi Jiangang; Feng Yi; Zhang Tianchen; Li Wei
With the purpose of performing field verification on 1100kv GIS UHF partial discharge sensors, the author utilized the steep pulse signal injection method and the transfer characteristic experimental method to perform this study. The results indicate that both of the methods have feasibility for UHF partial discharge internal sensor field verification, and have very high relevance. The study obtained the attenuation characteristics of UHF internal sensors with different GIS structures, and provides advice on how to optimize the field verification of UHF sensors.
china international conference on electricity distribution | 2016
Tao Shiyang; Cheng Xu; Wang Wenshan; Ma Mengchao; Duan Dapeng; Ren Zhigang; Wu Linlin; Zhang Tianchen
The paper establishes a defect simulation platform for multi-sensor 1100kVGIS, simulating four types of typical partial discharge defects within the GIS capsule and obtaining detection spectra of different types of defects as well as detection signal spectra of diversified position sensors. The attenuation characteristics of different position sensors were acquired under diversified voltage signals by utilizing steep pulse signal sources, as well as the relationship of equivalence between steep pulse injection signal amplitude and the discharge capacity of the discharge model, which provides a theoretical basis for field verification technology for a 1100kVGIS on-line monitoring system.
ieee international conference on power system technology | 2014
Fan Wenbo; Sheng Wanxing; Jiang Cheng; Li Jianxiu; Xu Jie; Tao Shiyang
Conjoint analysis is a new evaluation method. It has many advantages, but it has been seldom applied in the field of power equipment condition evaluation. This paper applies conjoint analysis method in the condition evaluation of distribution equipment, and proposes corresponding solutions to the specific problems appeared in implementation process: by refining the rule of consistency check in conjoint analysis, an optimization model with the goal of minimizing the adjustment to the original scores without violating the logical consistency constraint has been built; in view of the problem that too few levels to do accurate evaluation, the concept of membership degree is introduced in the transition process of index scores to levels to improve the evaluation sensitivity to the minor changes of index, making the results more accurate; under the presume of making sure that survey cards have reasonable redundancy, the linear correlation cards are removed in orthogonal experiment to reduce the cards number to improve the efficiency of investigation. The example analysis results show that those proposed solutions are correct and effective.
Archive | 2015
Tao Shiyang; Feng Yi; Jin Wenjie; Duan Dapeng; Cheng Xu; Wang Wenshan; Ren Zhigang
Archive | 2015
Cheng Xu; Wang Wenshan; Tao Shiyang; Li Wei; Qi Weiqiang; Ren Zhigang
Archive | 2015
Qi Weiqiang; Wang Wenshan; Ren Zhigang; Tao Shiyang; Cheng Xu; Duan Dapeng; Zhang Yujia
Archive | 2015
Duan Dapeng; Wang Liyong; Huang Chengjun; Cao Jiamei; Wang Wei; Ma Jingjun; Ren Zhigang; Tao Shiyang
Archive | 2015
Duan Dapeng; Wang Liyong; Huang Chengjun; Cao Jiamei; Wang Wei; Ma Jingjun; Ren Zhigang; Tao Shiyang
Archive | 2015
Ren Zhigang; Liu Ruoxi; Ren Jiancong; Tao Shiyang; Guo Xinyu; Duan Dapeng
Archive | 2015
Cheng Xu; Li Pei; Guan Yonggang; Wang Wenshan; Tao Shiyang