Featured researches published by Taoran Li.


Medical Physics | 2011

A planning quality evaluation tool for prostate adaptive IMRT based on machine learning

X Zhu; Y. Ge; Taoran Li; D Thongphiew; Fang-Fang Yin; Q. Jackie Wu

PURPOSE To ensure plan quality for adaptive IMRT of the prostate, we developed a quantitative evaluation tool using a machine learning approach. This tool generates dose volume histograms (DVHs) of organs-at-risk (OARs) based on prior plans as a reference, to be compared with the adaptive plan derived from fluence map deformation. METHODS Under the same configuration using seven-field 15 MV photon beams, DVHs of OARs (bladder and rectum) were estimated based on anatomical information of the patient and a model learned from a database of high quality prior plans. In this study, the anatomical information was characterized by the organ volumes and distance-to-target histogram (DTH). The database consists of 198 high quality prostate plans and was validated with 14 cases outside the training pool. Principal component analysis (PCA) was applied to DVHs and DTHs to quantify their salient features. Then, support vector regression (SVR) was implemented to establish the correlation between the features of the DVH and the anatomical information. RESULTS DVH/DTH curves could be characterized sufficiently just using only two or three truncated principal components, thus, patient anatomical information was quantified with reduced numbers of variables. The evaluation of the model using the test data set demonstrated its accuracy approximately 80% in prediction and effectiveness in improving ART planning quality. CONCLUSIONS An adaptive IMRT plan quality evaluation tool based on machine learning has been developed, which estimates OAR sparing and provides reference in evaluating ART.


Physics in Medicine and Biology | 2011

Adaptive prostate IGRT combining online re-optimization and re-positioning: a feasibility study.

Taoran Li; D Thongphiew; X Zhu; W. Robert Lee; Zeljko Vujaskovic; Fang-Fang Yin; Q. Jackie Wu

In prostate radiation therapy, inter-fractional organ motion/deformation has posed significant challenges on reliable daily dose delivery. To correct for this issue, off-line re-optimization and online re-positioning have been used clinically. In this paper, we propose an adaptive images guided radiation therapy (AIGRT) scheme that combines these two correction methods in an anatomy-driven fashion. The AIGRT process first tries to find a best plan for the daily target from a plan pool, which consists of the original CT plan and all previous re-optimized plans. If successful, the selected plan is used for daily treatment with translational shifts. Otherwise, the AIGRT invokes the re-optimization process of the CT plan for the anatomy of the day, which is afterward added to the plan pool as a candidate for future fractions. The AIGRT scheme is evaluated by comparisons with daily re-optimization and online re-positioning techniques based on daily target coverage, organs at risk (OAR) sparing and implementation efficiency. Simulated treatment courses for 18 patients with re-optimization alone, re-positioning alone and AIGRT shows that AIGRT offers reliable daily target coverage that is highly comparable to daily re-optimization and significantly improves from re-positioning. AIGRT is also seen to provide improved OAR sparing compared to re-positioning. Apart from dosimetric benefits, AIGRT in addition offers an efficient scheme to integrate re-optimization to current re-positioning-based IGRT workflow.


Cancer Journal | 2011

Adaptive radiation therapy: technical components and clinical applications.

Q Wu; Taoran Li; Qiuwen Wu; Fang-Fang Yin

In current standard radiation therapy process, patient anatomy is represented by the snapshot of computed tomographic images at the simulation for treatment planning. However, patient anatomy during the treatment course is not static, and the changes can be in the order of centimeters. The goal of the adaptive radiation therapy (ART) is to measure and account these variations in the treatment process, so that the optimal planned dose distribution is the same as the final delivered dose distribution. The field of the ART is rapidly evolving. The implementation of the ART principle is built on technical components in 3 main areas: image guidance, dose verification, and plan adaptation. The purpose of this review was to present different ART methods currently developed and used by different investigators.


Journal of Oncology | 2010

On-Line Adaptive Radiation Therapy: Feasibility and Clinical Study

Taoran Li; X Zhu; D Thongphiew; W. Robert Lee; Zeljko Vujaskovic; Qiuwen Wu; Fang-Fang Yin; Q. Jackie Wu

The purpose of this paper is to evaluate the feasibility and clinical dosimetric benefit of an on-line, that is, with the patient in the treatment position, Adaptive Radiation Therapy (ART) system for prostate cancer treatment based on daily cone-beam CT imaging and fast volumetric reoptimization of treatment plans. A fast intensity-modulated radiotherapy (IMRT) plan reoptimization algorithm is implemented and evaluated with clinical cases. The quality of these adapted plans is compared to the corresponding new plans generated by an experienced planner using a commercial treatment planning system and also evaluated by an in-house developed tool estimating achievable dose-volume histograms (DVHs) based on a database of existing treatment plans. In addition, a clinical implementation scheme for ART is designed and evaluated using clinical cases for its dosimetric qualities and efficiency.


Medical Physics | 2013

Strategies for automatic online treatment plan reoptimization using clinical treatment planning system: a planning parameters study.

Taoran Li; Qiuwen Wu; Y Zhang; I. Vergalasova; W. Robert Lee; Fang-Fang Yin; Q. Jackie Wu

PURPOSE Adaptive radiation therapy for prostate cancer using online reoptimization provides an improved control of interfractional anatomy variations. However, the clinical implementation of online reoptimization is currently limited by the low efficiency of current strategies and the difficulties associated with integration into the current treatment planning system. This study investigates the strategies for performing fast (~2 min) automatic online reoptimization with a clinical fluence-map-based treatment planning system; and explores the performance with different input parameters settings: dose-volume histogram (DVH) objective settings, starting stage, and iteration number (in the context of real time planning). METHODS Simulated treatments of 10 patients were reoptimized daily for the first week of treatment (5 fractions) using 12 different combinations of optimization strategies. Options for objective settings included guideline-based RTOG objectives, patient-specific objectives based on anatomy on the planning CT, and daily-CBCT anatomy-based objectives adapted from planning CT objectives. Options for starting stages involved starting reoptimization with and without the original plans fluence map. Options for iteration numbers were 50 and 100. The adapted plans were then analyzed by statistical modeling, and compared both in terms of dosimetry and delivery efficiency. RESULTS All online reoptimized plans were finished within ~2 min with excellent coverage and conformity to the daily target. The three input parameters, i.e., DVH objectives, starting stage, and iteration number, contributed to the outcome of optimization nearly independently. Patient-specific objectives generally provided better OAR sparing compared to guideline-based objectives. The benefit in high-dose sparing from incorporating daily anatomy into objective settings was positively correlated with the relative change in OAR volumes from planning CT to daily CBCT. The use of the original plan fluence map as the starting stage reduced OAR dose at the mid-dose region, but increased the monitor units by 17%. Differences of only 2cc or less in OAR V50%/V70Gy/V76Gy were observed between 100 and 50 iterations. CONCLUSIONS It is feasible to perform automatic online reoptimization in ~2 min using a clinical treatment planning system. Selecting optimal sets of input parameters is the key to achieving high quality reoptimized plans, and should be based on the individual patients daily anatomy, delivery efficiency, and time allowed for plan adaptation.


Journal of Applied Clinical Medical Physics | 2016

Diode‐based transmission detector for IMRT delivery monitoring: a validation study

Taoran Li; Q. Jackie Wu; Thomas Matzen; Fang-Fang Yin; J O'Daniel

The purpose of this work was to evaluate the potential of a new transmission detector for real‐time quality assurance of dynamic‐MLC‐based radiotherapy. The accuracy of detecting dose variation and static/dynamic MLC position deviations was measured, as well as the impact of the device on the radiation field (surface dose, transmission). Measured dose variations agreed with the known variations within 0.3%. The measurement of static and dynamic MLC position deviations matched the known deviations with high accuracy (0.7–1.2 mm). The absorption of the device was minimal (∼ 1%). The increased surface dose was small (1%–9%) but, when added to existing collimator scatter effects could become significant at large field sizes (≥30×30 cm2). Overall the accuracy and speed of the device show good potential for real‐time quality assurance. PACS number(s): 87.55.QrThe purpose of this work was to evaluate the potential of a new transmission detector for real-time quality assurance of dynamic-MLC-based radiotherapy. The accuracy of detecting dose variation and static/dynamic MLC position deviations was measured, as well as the impact of the device on the radiation field (surface dose, transmission). Measured dose variations agreed with the known variations within 0.3%. The measurement of static and dynamic MLC position deviations matched the known deviations with high accuracy (0.7-1.2 mm). The absorption of the device was minimal (∼ 1%). The increased surface dose was small (1%-9%) but, when added to existing collimator, scatter effects could become significant at large field sizes (≥30×30 cm2). Overall the accuracy and speed of the device show good potential for real-time quality assurance. PACS number(s): 87.55.Qr.


Journal of Applied Clinical Medical Physics | 2015

Impact of dose calculation accuracy during optimization on lung IMRT plan quality

Ying Li; A Rodrigues; Taoran Li; L Yuan; Fang-Fang Yin; Q. Jackie Wu

The purpose of this study was to evaluate the effect of dose calculation accuracy and the use of an intermediate dose calculation step during the optimization of intensity‐modulated radiation therapy (IMRT) planning on the final plan quality for lung cancer patients. This study included replanning for 11 randomly selected free‐breathing lung IMRT plans. The original plans were optimized using a fast pencil beam convolution algorithm. After optimization, the final dose calculation was performed using the analytical anisotropic algorithm (AAA). The Varian Treatment Planning System (TPS) Eclipse v11, includes an option to perform intermediate dose calculation during optimization using the AAA. The new plans were created using this intermediate dose calculation during optimization with the same planning objectives and dose constraints as in the original plan. Differences in dosimetric parameters for the planning target volume (PTV) dose coverage, organs‐at‐risk (OARs) dose sparing, and the number of monitor units (MU) between the original and new plans were analyzed. Statistical significance was determined with a p‐value of less than 0.05. All plans were normalized to cover 95% of the PTV with the prescription dose. Compared with the original plans, the PTV in the new plans had on average a lower maximum dose (69.45 vs. 71.96 Gy, p=0.005), a better homogeneity index (HI) (0.08 vs. 0.12, p=0.002), and a better conformity index (CI) (0.69 vs. 0.59, p=0.003). In the new plans, lung sparing was increased as the volumes receiving 5, 10, and 30 Gy were reduced when compared to the original plans (40.39% vs. 42.73%, p=0.005; 28.93% vs. 30.40%, p=0.001; 14.11% vs. 14.84%, p=0.031). The volume receiving 20 Gy was not significantly lower (19.60% vs. 20.38%, p=0.052). Further, the mean dose to the lung was reduced in the new plans (11.55 vs. 12.12 Gy, p=0.024). For the esophagus, the mean dose, the maximum dose, and the volumes receiving 20 and 60 Gy were lower in the new plans than in the original plans (17.91 vs. 19.24 Gy, p=0.004; 57.32 vs. 59.81 Gy, p=0.020; 39.34% vs. 41.59%, p=0.097; 12.56% vs. 15.35%, p=0.101). For the heart, the mean dose, the maximum dose, and the volume receiving 40 Gy were also lower in new plans (11.07 vs. 12.04 Gy, p=0.007; 56.41 vs. 57.7 Gy, p=0.027; 7.16% vs. 9.37%, p=0.012). The maximum dose to the spinal cord in the new plans was significantly lower than in the original IMRT plans (29.1 vs. 31.39 Gy, p=0.014). Difference in MU between the IMRT plans was not significant (1216.90 vs. 1198.91, p=0.328). In comparison to the original plans, the number of iterations needed to meet the optimization objectives in the new plans was reduced by a factor of 2 (2–3 vs. 5–6 iterations). Further, optimization was 30% faster corresponding to an average time savings of 10–15 min for the reoptimized plans. Accuracy of the dose calculation algorithm during optimization has an impact on planning efficiency, as well as on the final plan dosimetric quality. For lung IMRT treatment planning, utilizing the intermediate dose calculation during optimization is feasible for dose homogeneity improvement of the PTV and for improvement of optimization efficiency. PACS numbers: 87.55.D‐, 87.55.de, 87.55.dk


Medical Physics | 2014

Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

Taoran Li; Qiuwen Wu; Yun Yang; A Rodrigues; Fang-Fang Yin; Q. Jackie Wu

PURPOSE An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. METHODS The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the systems performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. RESULTS Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the systems ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. CONCLUSIONS The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.


Physics in Medicine and Biology | 2015

Atlas-guided prostate intensity modulated radiation therapy (IMRT) planning.

Y Sheng; Taoran Li; Y Zhang; W. Robert Lee; Fang-Fang Yin; Y. Ge; Q. Jackie Wu

An atlas-based IMRT planning technique for prostate cancer was developed and evaluated. A multi-dose atlas was built based on the anatomy patterns of the patients, more specifically, the percent distance to the prostate and the concaveness angle formed by the seminal vesicles relative to the anterior-posterior axis. A 70-case dataset was classified using a k-medoids clustering analysis to recognize anatomy pattern variations in the dataset. The best classification, defined by the number of classes or medoids, was determined by the largest value of the average silhouette width. Reference plans from each class formed a multi-dose atlas. The atlas-guided planning (AGP) technique started with matching the new case anatomy pattern to one of the reference cases in the atlas; then a deformable registration between the atlas and new case anatomies transferred the dose from the atlas to the new case to guide inverse planning with full automation. 20 additional clinical cases were re-planned to evaluate the AGP technique. Dosimetric properties between AGP and clinical plans were evaluated. The classification analysis determined that the 5-case atlas would best represent anatomy patterns for the patient cohort. AGP took approximately 1 min on average (corresponding to 70 iterations of optimization) for all cases. When dosimetric parameters were compared, the differences between AGP and clinical plans were less than 3.5%, albeit some statistical significances observed: homogeneity index (p  >  0.05), conformity index (p  <  0.01), bladder gEUD (p  <  0.01), and rectum gEUD (p  =  0.02). Atlas-guided treatment planning is feasible and efficient. Atlas predicted dose can effectively guide the optimizer to achieve plan quality comparable to that of clinical plans.


Medical Physics | 2017

Outlier identification in radiation therapy knowledge‐based planning: A study of pelvic cases

Y Sheng; Y. Ge; L Yuan; Taoran Li; Fang-Fang Yin; Q Wu

Purpose: The purpose of this study was to apply statistical metrics to identify outliers and to investigate the impact of outliers on knowledge‐based planning in radiation therapy of pelvic cases. We also aimed to develop a systematic workflow for identifying and analyzing geometric and dosimetric outliers. Methods: Four groups (G1–G4) of pelvic plans were sampled in this study. These include the following three groups of clinical IMRT cases: G1 (37 prostate cases), G2 (37 prostate plus lymph node cases) and G3 (37 prostate bed cases). Cases in G4 were planned in accordance with dynamic‐arc radiation therapy procedure and include 10 prostate cases in addition to those from G1. The workflow was separated into two parts: 1. identifying geometric outliers, assessing outlier impact, and outlier cleaning; 2. identifying dosimetric outliers, assessing outlier impact, and outlier cleaning. G2 and G3 were used to analyze the effects of geometric outliers (first experiment outlined below) while G1 and G4 were used to analyze the effects of dosimetric outliers (second experiment outlined below).A baseline model was trained by regarding all G2 cases as inliers. G3 cases were then individually added to the baseline model as geometric outliers. The impact on the model was assessed by comparing leverages of inliers (G2) and outliers (G3). A receiver‐operating‐characteristic (ROC) analysis was performed to determine the optimal threshold. The experiment was repeated by training the baseline model with all G3 cases as inliers and perturbing the model with G2 cases as outliers.A separate baseline model was trained with 32 G1 cases. Each G4 case (dosimetric outlier) was subsequently added to perturb the model. Predictions of dose‐volume histograms (DVHs) were made using these perturbed models for the remaining 5 G1 cases. A Weighted Sum of Absolute Residuals (WSAR) was used to evaluate the impact of the dosimetric outliers. Results: The leverage of inliers and outliers was significantly different. The Area‐Under‐Curve (AUC) for differentiating G2 (outliers) from G3 (inliers) was 0.98 (threshold: 0.27) for the bladder and 0.81 (threshold: 0.11) for the rectum. For differentiating G3 (outlier) from G2 (inlier), the AUC (threshold) was 0.86 (0.11) for the bladder and 0.71 (0.11) for the rectum. Significant increase in WSAR was observed in the model with 3 dosimetric outliers for the bladder (P < 0.005 with Bonferroni correction), and in the model with only 1 dosimetric outlier for the rectum (P < 0.005). Conclusions: We established a systematic workflow for identifying and analyzing geometric and dosimetric outliers, and investigated statistical metrics for outlier detection. Results validated the necessity for outlier detection and clean‐up to enhance model quality in clinical practice.

Collaboration


Dive into the Taoran Li's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Y. Ge

University of North Carolina at Charlotte

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge