Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Teng Lu is active.

Publication


Featured researches published by Teng Lu.


PLOS ONE | 2015

Meta-Analysis Comparing Zero-Profile Spacer and Anterior Plate in Anterior Cervical Fusion.

Jun Dong; Meng Lu; Teng Lu; Baobao Liang; Junkui Xu; Jun Zhou; Hongjun Lv; Jie Qin; Xuan Cai; Sihua Huang; Haopeng Li; Dong Wang; Xijing He

Background Anterior plate fusion is an effective procedure for the treatment of cervical spinal diseases but is accompanied by a high incidence of postoperative dysphagia. A zero profile (Zero-P) spacer is increasingly being used to reduce postoperative dysphagia and other potential complications associated with surgical intervention. Studies comparing the Zero-P spacer and anterior plate have reported conflicting results. Methodology A meta-analysis was conducted to compare the safety, efficacy, radiological outcomes and complications associated with the use of a Zero-P spacer versus an anterior plate in anterior cervical spine fusion for the treatment of cervical spinal disease. We comprehensively searched PubMed, Embase, the Cochrane Library and other databases and performed a meta-analysis of all randomized controlled trials (RCTs) and prospective or retrospective comparative studies assessing the two techniques. Results Ten studies enrolling 719 cervical spondylosis patients were included. The pooled data showed significant differences in the operation time [SMD = –0.58 (95% CI = −0.77 to 0.40, p < 0.01)] and blood loss [SMD = −0.40, 95% CI (−0.59 to –0.21), p < 0.01] between the two groups. Compared to the anterior plate group, the Zero-P group exhibited a significantly improved JOA score and reduced NDI and VAS. However, anterior plate fusion had greater postoperative segmental and cervical Cobb’s angles than the Zero-P group at the last follow-up. The fusion rate in the two groups was similar. More importantly, the Zero-P group had a lower incidence of earlier and later postoperative dysphagia. Conclusions Compared to anterior plate fusion, Zero-P is a safer and effective procedure, with a similar fusion rate and lower incidence of earlier and later postoperative dysphagia. However, the results of this meta-analysis should be accepted with caution due to the limitations of the study. Further evaluation and large-sample RCTs are required to confirm and update the results of this study.


computer assisted radiology and surgery | 2016

Cervical screw placement using rapid prototyping drill templates for navigation: a literature review

Teng Lu; Chao Liu; Jun Dong; Meng Lu; Haopeng Li; Xijing He

PurposeDue to the high screw malposition rate and the potential risk of neurovascular injury in cervical fixation surgeries, guided tools, mainly computer-assisted surgery navigation systems and rapid prototyping drill templates (RPDTs) have increasingly been developed to help surgeons improve screw placement accuracy. Although RPDTs have been used in cervical surgeries for almost 2 decades, no specific review has been performed detailing the state of this technique. Thus, in the current review, we fully discuss the status of applying RPDTs in cervical surgeries.MethodsStudies that tested the accuracy and reliability of RPDTs in guiding cervical screw placements were included in this review. The fabrication workflow and usage of RPDTs, the accuracy and reliability of using RPDTs for screw and plate placement, the advantages and disadvantages of RPDTs and their prospects for future applications as a part of cervical fixation instrumentation are discussed.ResultsAs the design of RPDTs becomes more rational, the accuracy and reliability of these devices have significantly improved in cervical fixation surgeries. Moreover, RPDTs decrease the intraoperative radiation exposure for surgeons and patients relative to conventional methods. However, some disadvantages also exist. The fabrication of RPDTs is time-consuming, and the time required to learn the related software is long.ConclusionWe believe that because of their merits, the RPDT technique is worth promoting for use in cervical surgeries. However, the time-consuming fabrication workflow and the long period required to learn the related software might limit its widespread use. In the future, the workflow should be simplified to reduce the extra workload for surgeons. Moreover, more clinical studies with high-level evidence are still needed to further test its accuracy and feasibility.


Medical Science Monitor | 2017

Single-Level Anterior Cervical Corpectomy and Fusion Using a New 3D-Printed Anatomy-Adaptive Titanium Mesh Cage for Treatment of Cervical Spondylotic Myelopathy and Ossification of the Posterior Longitudinal Ligament: A Retrospective Case Series Study

Teng Lu; Chao Liu; Baohui Yang; Jiantao Liu; Feng Zhang; Dong Wang; Haopeng Li; Xijing He

Background The aim of this study was to evaluate the clinical and radiological outcomes of the use of a new 3D-printed anatomy-adaptive titanium mesh cage (AA-TMC) for single-level anterior cervical corpectomy and fusion (ACCF) in patients with cervical spondylotic myelopathy (CSM) and ossification of the posterior longitudinal ligament (OPLL). Material/Methods We retrospectively reviewed the records of 15 consecutive patients who underwent ACCF surgeries with AA-TMC implantation. The Japanese Orthopedic Association (JOA) scoring system, a visual analogue scale (VAS), the mean intervertebral height (MIBH) of the surgical segments, and the surgical segmental angle (SSA) were recorded preoperatively, immediately after surgery and at the final follow-up visit. The outcomes of these parameters at different time points were compared. Results Six months after ACCF surgery, solid bony fusions of the surgical level were achieved in all patients. The mean MIBH was 21.05±1.99 mm preoperatively, 27.51±1.44 mm immediately after surgery (P<0.05), and 26.85±1.25 mm at the last follow-up visit (P<0.05). At the last follow-up visit, none of the AA-TMCs exhibited severe subsidence (>3 mm). The mean SSA was 6.66±7.08° preoperatively, 14.03±2.3° immediately after surgery (P<0.05), and 15.09±2.1° at the final follow-up visit (P>0.05). The mean VAS and JOA scores were 6.6±1.26 and 10.47±2.07, respectively, preoperatively and 2.47±1.3 and 13.6±1.96 immediately after surgery, respectively (P<0.05). At the last follow-up visit, the mean VAS and JOA were further restored to 1.67±1.18 and 14.9±1.39, respectively (P<0.05). Conclusions The application of the AA-TMC in single-level ACCF significantly relieved symptoms of CSM and OPLL. The rational design of the AA-TMC restores the surgical segmental curvature, maintains the intervertebral height, and prevents postoperative subsidence-related complications.


Clinics | 2015

Artificial disc and vertebra system: a novel motion preservation device for cervical spinal disease after vertebral corpectomy

Jun Dong; Meng Lu; Teng Lu; Baobao Liang; Junkui Xu; Jie Qin; Xuan Cai; Sihua Huang; Dong Wang; Haopeng Li; Xijing He

OBJECTIVE: To determine the range of motion and stability of the human cadaveric cervical spine after the implantation of a novel artificial disc and vertebra system by comparing an intact group and a fusion group. METHODS: Biomechanical tests were conducted on 18 human cadaveric cervical specimens. The range of motion and the stability index range of motion were measured to study the function and stability of the artificial disc and vertebra system of the intact group compared with the fusion group. RESULTS: In all cases, the artificial disc and vertebra system maintained intervertebral motion and reestablished vertebral height at the operative level. After its implantation, there was no significant difference in the range of motion (ROM) of C3–7 in all directions in the non-fusion group compared with the intact group (p>0.05), but significant differences were detected in flexion, extension and axial rotation compared with the fusion group (p<0.05). The ROM of adjacent segments (C3−4, C6−7) of the non-fusion group decreased significantly in some directions compared with the fusion group (p<0.05). Significant differences in the C4-6 ROM in some directions were detected between the non-fusion group and the intact group. In the fusion group, the C4−6 ROM in all directions decreased significantly compared with the intact and non-fusion groups (p<0.01). The stability index ROM (SI-ROM) of some directions was negative in the non-fusion group, and a significant difference in SI-ROM was only found in the C4−6 segment of the non-fusion group compared with the fusion group. CONCLUSION: An artificial disc and vertebra system could restore vertebral height and preserve the dynamic function of the surgical area and could theoretically reduce the risk of adjacent segment degeneration compared with the anterior fusion procedure. However, our results should be considered with caution because of the low power of the study. The use of a larger sample should be considered in future studies.


International Journal of Molecular Sciences | 2014

Effects of Different Sera Conditions on Olfactory Ensheathing Cells in Vitro

Meng Lu; Jun Dong; Teng Lu; Hongjun Lv; Pinglin Yang; Zhijian Cheng; Jin Li; Baobao Liang; Junkui Xu; Haopeng Li; Xijing He

Transplantation of olfactory ensheathing cells (OEC) is a promising therapy in spinal cord injury (SCI) treatment. However, the therapeutic efficacy of this method is unstable due to unknown reasons. Considering the alterations in the culture environment that occur during OEC preparation for transplantation, we hypothesize that these changes may cause variations in the curative effects of this method. In this study, we compared OEC cultured in medium containing different types and concentrations of serum. After purification and passage, the OEC were cultured for 7 days in different media containing 5%, 10%, 15% or 20% fetal bovine serum (FBS) or rat serum (RS), or the cells were cultured in FBS-containing medium first, followed by medium containing RS. In another group, the OEC were first cultured in 10% FBS for 3 days and then cultured with rat spinal cord explants with 10% RS for another 4 days. An MTT assay and P75 neurotrophin receptor immunofluorescence staining were used to examine cell viability and OEC numbers, respectively. The concentration of neurotrophin-3 (NT-3), which is secreted by OEC into the culture supernatant, was detected using the enzyme-linked immunosorbent assay (ELISA). RT-PCR was applied to investigate the NT-3 gene expression in OEC according to different groups. Compared with FBS, RS reduced OEC proliferation in relation to OEC counts (χ2 = 166.279, df = 1, p < 0.01), the optical density (OD) value in the MTT assay (χ2 = 34.730, df = 1, p < 0.01), and NT-3 concentration in the supernatant (χ2 = 242.997, df = 1, p < 0.01). OEC cultured with spinal cord explants secreted less NT-3 than OEC cultured alone (F = 9.611, df = 5.139, p < 0.01). Meanwhile, the order of application of different sera was not influential. There was statistically significant difference in NT-3 gene expression among different groups when the serum concentration was 15% (χ2 = 64.347, df = 1, p < 0.01). In conclusion, different serum conditions may be responsible for the variations in OEC proliferation and function.


Journal of Electromyography and Kinesiology | 2018

Reliability and validity of a Coda Motion 3-D Analysis system for measuring cervical range of motion in healthy subjects

Hui Song; Xu Zhai; Zhongyang Gao; Teng Lu; Qian Tian; Haopeng Li; Xijing He

In the past two decades, many tools have been reported to measure the cervical range of motion (CROM), but most of the results are controversial in healthy individuals and/or individuals with neck pain. The Coda Motion 3-D Analysis system is a new instrument that measures three-dimensional joint movement. However, measurements of CROM using this system have yet to be conducted. Here, we investigate the reliability and validity of the Coda Motion 3-D Analysis System for measuring CROM in healthy adults. Sixty healthy volunteers were involved in this reliability study. Two trained investigators (M1 and M2) used the Coda Motion 3-D Analysis System to measure CROM. M1 and M2 measured all the volunteers once independently; after a short rest, M1 then measured all of them again. The intraclass correlation coefficient (ICC), standard error of the measurements (SEM), smallest detectable difference (SDD), a scatter diagram, and the limits of agreement (LoAs) were applied to evaluate the inter-tester and intra-tester reliability. Thirty healthy volunteers were involved in this validity study. The cervical flexion and extension ranges of motion were measured simultaneously with both the Coda Motion 3-D Analysis System and X-ray. A scatter diagram, the Pearson correlation coefficient and LoAs were used to evaluate the validity. Excellent intra-tester and inter-tester reliabilities were observed for the Coda Motion 3-D Analysis System (intra-tester ICC: 0.84-0.95, inter-tester ICC: 0.84-0.90). Good validity was achieved in extension and flexion with Pearson correlation coefficients ranging from 0.78 to 0.91. The Coda Motion 3-D Analysis System has excellent reliability for the measurement of CROM and good validity for measurements of flexion and extension in healthy subjects. This system has the potential to be used to measure the normal active CROM in the clinic and is accurate, safe, non-invasive, and radiation free.


Medical Science Monitor | 2017

Effects of Titanium Mesh Cage End Structures on the Compressive Load at the Endplate Interface: A Cadaveric Biomechanical Study

Teng Lu; Hui Liang; Chao Liu; Shuai Guo; Ting Zhang; Baohui Yang; Xijing He

Background This study aimed to evaluate whether obliquely angled and ring-shaped titanium mesh cage (TMC) end structures can improve the compressive load on the endplate interface in anterior cervical corpectomy and fusion (ACCF). Material/Methods A total of 23 volunteers underwent cervical lateral x-ray. The oblique angle of the superior endplate was measured, which was used to construct the gradient of the TMC end. Forty-two fresh cadaveric vertebral bodies were harvested and randomly distributed among four TMC groups with different ends. The baseline indicators of bone mineral density and anteroposterior and transverse dimensions were recorded. The superior endplate was placed at an angle of 12° when performing uniaxial compression testing. The maximum loads of the four TMCs were assessed. Results There were no significant differences among the groups regarding the baseline indicators. The conventional TMC had the lowest maximum load (1362.3±221.78 N, p<0.05), whereas the TMC with an obliquely end ring had the highest maximum load (2095.82±285.64 N, p<0.05). The maximum loads of the TMCs with oblique footprints and flat end ring were much higher than that of the conventional TMC (p<0.05) but significantly lower than that of the TMC with the obliquely end ring (p<0.05), with average values of 1806.91±246.98 N and 1725.3±213.33 N, respectively. Conclusions Both the ring shape and oblique angle of the TMC end contributed to an increase in compressive force and are advocated for use in TMC structure optimization to decrease the incidence of TMC subsidence in ACCF.


BioMed Research International | 2017

Single-Session Combined Anterior-Posterior Approach for Treatment of Ankylosing Spondylitis with Obvious Displaced Lower Cervical Spine Fractures and Dislocations

Baohui Yang; Teng Lu; Haopeng Li

For patients with AS and lower cervical spine fractures, surgical methods have mainly included the single anterior approach, single posterior approach, and combined anterior-posterior approach. However, various surgical procedures were utilized because the fractures have not been clearly classified according to presence of displacement in these previous studies. Consequently, controversies have been raised regarding the selection of the surgical procedure. This study retrospective analysis was conducted in 12 patients with AS and lower cervical spine fractures and dislocations and explored single-session combined anterior-posterior approach for the treatment of AS with obvious displaced lower cervical spine fractures and dislocations which has demonstrated advantages such as good stabilization, satisfied fracture healing, and easy postoperative cares. However, to some extent, the difficulty and risk of this approach should be considered. Attention should be paid to the prevention of perioperative complications.


BioMed Research International | 2016

Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study

Shuai Guo; Teng Lu; Qiaolong Hu; Baohui Yang; Xijing He; Haopeng Li

Purpose. To preliminarily evaluate the feasibility and accuracy of using rapid prototyping drill templates (RPDTs) for C1 lateral mass screw (C1-LMS) and C2 pedicle screw (C2-PS) placement. Methods. 23 formalin-fixed craniocervical cadaver specimens were randomly divided into two groups. In the conventional method group, intraoperative fluoroscopy was used to assist the screw placement. In the RPDT navigation group, specific RPDTs were constructed for each specimen and were used intraoperatively for screw placement navigation. The screw position, the operating time, and the fluoroscopy time for each screw placement were compared between the 2 groups. Results. Compared with the conventional method, the RPDT technique significantly increased the placement accuracy of the C2-PS (p < 0.05). In the axial plane, using RPDTs also significantly increased C1-LMS placement accuracy (p < 0.05). In the sagittal plane, although using RPDTs had a very high accuracy rate (100%) in C1-LMS placement, it was not statistically significant compared with the conventional method (p > 0.05). Moreover, the RPDT technique significantly decreased the operating and fluoroscopy times. Conclusion. Using RPDTs significantly increases the accuracy of C1-LMS and C2-PS placement while decreasing the screw placement time and the radiation exposure. Due to these advantages, this approach is worth promoting for use in the Harms technique.


Zhongguo Gu Shang | 2018

[Rapid prototyping navigation template assisted cervical screw implantation:a review].

Zhijing Wen; Teng Lu; Zhengchao Gao; Jiantao Liu; Yibin Wang; Hui Liang; Xijing He

Collaboration


Dive into the Teng Lu's collaboration.

Top Co-Authors

Avatar

Xijing He

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Haopeng Li

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Baohui Yang

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Jun Dong

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Meng Lu

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Baobao Liang

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Chao Liu

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Dong Wang

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Hui Liang

Xi'an Jiaotong University

View shared research outputs
Top Co-Authors

Avatar

Jie Qin

Xi'an Jiaotong University

View shared research outputs
Researchain Logo
Decentralizing Knowledge