Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Theodore Hughes-Riley is active.

Publication


Featured researches published by Theodore Hughes-Riley.


PLOS ONE | 2012

Pathway to Cryogen Free Production of Hyperpolarized Krypton-83 and Xenon-129

Joseph S. Six; Theodore Hughes-Riley; Karl F. Stupic; Galina E. Pavlovskaya; Thomas Meersmann

Hyperpolarized (hp) 129Xe and hp 83Kr for magnetic resonance imaging (MRI) are typically obtained through spin-exchange optical pumping (SEOP) in gas mixtures with dilute concentrations of the respective noble gas. The usage of dilute noble gases mixtures requires cryogenic gas separation after SEOP, a step that makes clinical and preclinical applications of hp 129Xe MRI cumbersome. For hp 83Kr MRI, cryogenic concentration is not practical due to depolarization that is caused by quadrupolar relaxation in the condensed phase. In this work, the concept of stopped flow SEOP with concentrated noble gas mixtures at low pressures was explored using a laser with 23.3 W of output power and 0.25 nm linewidth. For 129Xe SEOP without cryogenic separation, the highest obtained MR signal intensity from the hp xenon-nitrogen gas mixture was equivalent to that arising from 15.5±1.9% spin polarized 129Xe in pure xenon gas. The production rate of the hp gas mixture, measured at 298 K, was 1.8 cm3/min. For hp 83Kr, the equivalent of 4.4±0.5% spin polarization in pure krypton at a production rate of 2 cm3/min was produced. The general dependency of spin polarization upon gas pressure obtained in stopped flow SEOP is reported for various noble gas concentrations. Aspects of SEOP specific to the two noble gas isotopes are discussed and compared with current theoretical opinions. A non-linear pressure broadening of the Rb D1 transition was observed and taken into account for the qualitative description of the SEOP process.


Science of The Total Environment | 2016

Intermittent aeration to improve wastewater treatment efficiency in pilot-scale constructed wetland

Enrica Uggetti; Theodore Hughes-Riley; Robert H. Morris; Michael Newton; Christophe L. Trabi; Patrick Hawes; Jaume Puigagut; Joan García

Forced aeration of horizontal subsurface flow constructed wetlands (HSSF CWs) is nowadays a recognized method to improve treatment efficiency, mainly in terms of ammonium removal. While numerous investigations have been reported testing constant aeration, scarce information can be found about the efficiency of intermittent aeration. This study aims at comparing continuous and intermittent aeration, establishing if there is an optimal regime that will increase treatment efficiency of HSSF CWs whilst minimizing the energy requirement. Full and intermittent aeration were tested in a pilot plant of three HSSF CWs (2.64m(2) each) fed with primary treated wastewater. One unit was fully aerated; one intermittently aerated (i.e. by setting a limit of 0.5mg/L dissolved oxygen within the bed) with the remaining unit not aerated as a control. Results indicated that intermittent aeration was the most successful operating method. Indeed, the coexistence of aerobic and anoxic conditions promoted by the intermittent aeration resulted in the highest COD (66%), ammonium (99%) and total nitrogen (79%) removals. On the other hand, continuous aeration promotes ammonium removal (99%), but resulted in nitrate concentrations in the effluent of up to 27mg/L. This study demonstrates the high potential of the intermittent aeration to increase wastewater treatment efficiency of CWs providing an extreme benefit in terms of the energy consumption.


Journal of Magnetic Resonance | 2013

Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications

Theodore Hughes-Riley; Joseph S. Six; David M.L. Lilburn; Karl F. Stupic; Alan C. Dorkes; Dominick Shaw; Galina E. Pavlovskaya; Thomas Meersmann

As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp (129)Xe or hp (83)Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp (129)Xe handling, while (83)Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The (83)Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of (129)Xe in corresponding mixtures. The experimental setup also facilitated (129)Xe T1 relaxation measurements as a function of O2 concentration within excised lungs.


Magnetic Resonance Imaging | 2014

Pulmonary MRI contrast using Surface Quadrupolar Relaxation (SQUARE) of hyperpolarized 83Kr

Joseph S. Six; Theodore Hughes-Riley; David M.L. Lilburn; Alan C. Dorkes; Karl F. Stupic; Dominick Shaw; Peter G. Morris; Ian P. Hall; Galina E. Pavlovskaya; Thomas Meersmann

Hyperpolarized 83Kr has previously been demonstrated to enable MRI contrast that is sensitive to the chemical composition of the surface in a porous model system. Methodological advances have lead to a substantial increase in the 83Kr hyperpolarization and the resulting signal intensity. Using the improved methodology for spin exchange optical pumping of isotopically enriched 83Kr, internal anatomical details of ex vivo rodent lung were resolved with hyperpolarized 83Kr MRI after krypton inhalation. Different 83Kr relaxation times were found between the main bronchi and the parenchymal regions in ex vivo rat lungs. The T1 weighted hyperpolarized 83Kr MRI provided a first demonstration of surface quadrupolar relaxation (SQUARE) pulmonary MRI contrast.


PLOS ONE | 2013

Validating Excised Rodent Lungs for Functional Hyperpolarized Xenon-129 MRI

David M.L. Lilburn; Theodore Hughes-Riley; Joseph S. Six; Karl F. Stupic; Dominick Shaw; Galina E. Pavlovskaya; Thomas Meersmann

Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) 129Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp 129Xe. Straightforward hp 129Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp 129Xe probe volumes during the inhalation cycle. Hp 129Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.


Sensors | 2017

A study of thermistor performance within a textile structure

Theodore Hughes-Riley; Pasindu Lugoda; T Dias; Christophe L. Trabi; Robert H. Morris

Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the early detection of diabetic foot ulcer formation. To this end an electronic temperature-sensor yarn was developed by embedding a commercially available thermistor chip into the fibres of a yarn, which can be used to produce a textile or a garment. As part of this process a resin was used to encapsulate the thermistor. This protects the thermistor from mechanical and chemical stresses, and also allows the sensing yarn to be washed. Building off preliminary work, the behaviour and performance of an encapsulated thermistor has been characterised to determine the effect of encapsulation on the step response time and absolute temperature measurements. Over the temperature range of interest only a minimal effect was observed, with step response times varying between 0.01–0.35 s. A general solution is presented for the heat transfer coefficient compared to size of the micro-pod formed by the encapsulation of the thermistor. Finally, a prototype temperature-sensing sock was produced using a network of sensing yarns as a demonstrator of a system that could warn of impending ulcer formation in diabetic patients.


Magnetic Resonance in Medicine | 2016

Investigating lung responses with functional hyperpolarized xenon-129 MRI in an ex vivo rat model of asthma

David M.L. Lilburn; Amanda L. Tatler; Joseph S. Six; Clémentine Lesbats; Anthony Habgood; Joanne Porte; Theodore Hughes-Riley; Dominick Shaw; Gisli Jenkins; Thomas Meersmann

Asthma is a disease of increasing worldwide importance that calls for new investigative methods. Ex vivo lung tissue is being increasingly used to study functional respiratory parameters independent of confounding systemic considerations but also to reduce animal numbers and associated research costs. In this work, a straightforward laboratory method is advanced to probe dynamic changes in gas inhalation patterns by using an ex vivo small animal ovalbumin (OVA) model of human asthma.


Sensors | 2018

Developing an Acoustic Sensing Yarn for Health Surveillance in a Military Setting

Theodore Hughes-Riley; T Dias

Overexposure to high levels of noise can cause permanent hearing disorders, which have a significant adverse effect on the quality of life of those affected. Injury due to noise can affect people in a variety of careers including construction workers, factory workers, and members of the armed forces. By monitoring the noise exposure of workers, overexposure can be avoided and suitable protective equipment can be provided. This work focused on the creation of a noise dosimeter suitable for use by members of the armed forces, where a discrete dosimeter was integrated into a textile helmet cover. In this way the sensing elements could be incorporated very close to the ears, providing a highly representative indication of the sound level entering the body, and also creating a device that would not interfere with military activities. This was achieved by utilising commercial microelectromechanical system microphones integrated within the fibres of yarn to create an acoustic sensing yarn. The acoustic sensing yarns were fully characterised over a range of relevant sound levels and frequencies at each stage in the yarn production process. The yarns were ultimately integrated into a knitted helmet cover to create a functional acoustic sensing helmet cover prototype.


Sensors | 2018

A wearable textile thermograph

Pasindu Lugoda; Theodore Hughes-Riley; Robert H. Morris; T Dias

In medicine, temperature changes can indicate important underlying pathologies such as wound infection. While thermographs for the detection of wound infection exist, a textile substrate offers a preferable solution to the designs that exist in the literature, as a textile is very comfortable to wear. This work presents a fully textile, wearable, thermograph created using temperature-sensing yarns. As described in earlier work, temperature-sensing yarns are constructed by encapsulating an off-the-shelf thermistor into a polymer resin micro-pod and then embedding this within the fibres of a yarn. This process creates a temperature-sensing yarn that is conformal, drapeable, mechanically resilient, and washable. This work first explored a refined yarn design and characterised its accuracy to take absolute temperature measurements. The influence of contact errors with the refined yarns was explored seeing a 0.24 ± 0.03 measurement error when the yarn was held just 0.5 mm away from the surface being measured. Subsequently, yarns were used to create a thermograph. This work characterises the operation of the thermograph under a variety of simulated conditions to better understand the functionality of this type of textile temperature sensor. Ambient temperature, insulating material, humidity, moisture, bending, compression and stretch were all explored. This work is an expansion of an article published in The 4th International Conference on Sensor and Applications.


Scientific Reports | 2018

Photodiodes embedded within electronic textiles

Achala Satharasinghe; Theodore Hughes-Riley; T Dias

A novel photodiode-embedded yarn has been presented and characterized for the first time, offering new possibilities for applications including monitoring body vital signs (including heart rate, blood oxygen and skin temperature) and environmental conditions (light, humidity and ultraviolet radiation). To create an E-Textile integrated with electronic devices that is comfortable, conformal, aesthetically pleasing and washable, electronic components are best integrated within the structure of a textile fabric in yarn form. The device is first encapsulated within a protective clear resin micro-pod before being covered in a fibrous sheath. The resin micro-pod and covering fibres have a significant effect on the nature of light received by the photoactive region of the device. This work characterised the effects of both encapsulating photodiodes within resin micro-pods and covering the micro-pod with a fibrous sheath on the opto-electronic parameters. A theoretical model is presented to provide an estimate for these effects and validated experimentally using two photodiode types and a range of different resin micro-pods. This knowledge may have wider applications to other devices with small-scale opto-electronic components. Wash tests confirmed that the yarns could survive multiple machine wash and drying cycles without deterioration in performance.

Collaboration


Dive into the Theodore Hughes-Riley's collaboration.

Top Co-Authors

Avatar

Robert H. Morris

Nottingham Trent University

View shared research outputs
Top Co-Authors

Avatar

Michael Newton

Nottingham Trent University

View shared research outputs
Top Co-Authors

Avatar

T Dias

Nottingham Trent University

View shared research outputs
Top Co-Authors

Avatar

Joseph S. Six

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Enrica Uggetti

Polytechnic University of Catalonia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dominick Shaw

University of Nottingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Karl F. Stupic

University of Nottingham

View shared research outputs
Researchain Logo
Decentralizing Knowledge