Journal of Vascular and Interventional Radiology | 2013

Quantification of Tissue Shrinkage and Dehydration Caused by Microwave Ablation: Experimental Study in Kidneys for the Estimation of Effective Coagulation Volume

Christof M. Sommer; Steffen A. Sommer; Theresa Mokry; Theresa Gockner; Daniel Gnutzmann; Nadine Bellemann; Anne Schmitz; B Radeleff; Hans U. Kauczor; U Stampfl; Philippe L. Pereira

PURPOSE To quantify the extent of tissue shrinkage and dehydration caused by microwave (MW) ablation in kidneys for estimation of effective coagulation volume. MATERIALS AND METHODS MW ablations were carried out in ex vivo porcine kidneys. Six study groups were defined: groups 1A, 2A, and 3A for MW ablation (90 W for 5 min, 7.5 min, or 10 min), and groups 1B, 2B, and 3B for control (without MW ablation). Pre- and postinterventional volume analyses were performed. Effective coagulation volumes (original tissue included in coagulation) were determined. Postinterventional dehydration analyses were performed with calculation of mean mass fractions of water. RESULTS Mean deployed energies were 21.6 kJ ± 1.1 for group 1A, 29.9 kJ ± 1.0 for group 2A, and 42.1 kJ ± 0.5 kJ for group 3A, and were significantly different (P < .0001). Differences between pre- and postinterventional volumes were -3.8% ± 0.6 for group 1A, -5.6% ± 0.9 for group 2A, and -7.2% ± 0.4 for group 3A, and -1.1% ± 0.3 for group 1B, -1.8% ± 0.4 for group 2B, and -1.1% ± 0.4 for group 3B. Postinterventional volumes were significantly smaller than preinterventional volumes for all groups (P < .01). Underestimations of effective coagulation volume from visualized coagulation volume were 26.1% ± 3.5 for group 1A, 35.2% ± 11.2 for group 2A, and 42.1% ± 4.9 for group 3A, which were significantly different (P < .01). Mean mass fractions of water were 64.2% ± 1.4 for group 1A, 63.2% ± 1.7 for group 2A, and 62.6% ± 1.8% for group 3A, with significant differences versus corresponding control groups (P < .01). CONCLUSIONS For MW ablation in kidneys, underestimation of effective coagulation volume based on visualized coagulation volume is significantly greater with greater deployed energy. Therefore, local dehydration with tissue shrinkage is a potential contributor.


European Journal of Radiology | 2012

Technical and clinical outcome of transjugular intrahepatic portosystemic stent shunt: Bare metal stents (BMS) versus viatorr stent-grafts (VSG)

Christof M. Sommer; Theresa Gockner; U Stampfl; Nadine Bellemann; Peter Sauer; Tom M. Ganten; Juergen Weitz; Hans U. Kauczor; B Radeleff

PURPOSE To compare retrospectively angiographical and clinical results in patients undergoing transjugular intrahepatic portosystemic stent-shunt (TIPS) using BMS or VSG. MATERIALS AND METHODS From February 2001 to January 2010, 245 patients underwent TIPS. From those, 174 patients matched the inclusion criteria with elective procedures and institutional follow-up. Group (I) consisted of 116 patients (mean age, 57.0±11.1 years) with BMS. Group (II) consisted of 58 patients with VSG (mean age, 53.5±16.1 years). Angiographic and clinical controls were scheduled at 3, 6 and 12 months, followed by clinical controls every 6 months. Primary study goals included hemodynamic success, shunt patency as well as time to and number of revisions. Secondary study goals included clinical success. RESULTS Hemodynamic success was 92.2% in I and 91.4% in II (n.s.). Primary patency was significantly higher in II compared to I (53.8% after 440.4±474.5 days versus 45.8% after 340.1±413.8 days; p<0.05). The first TIPS revision was performed significantly later in II compared to I (288.3±334.7 days versus 180.1±307.0 days; p<0.05). In the first angiographic control, a portosystemic pressure gradient ≥15 mmHg was present in 73.9% in I and in 39.4% in II (p<0.05). Clinical success was 73.7-86.2% after 466.3±670.1 days in I and 85.7-90.5% after 617.5±642.7 days in II (n.s.). Hepatic encephalopathy was 37.5% in I and 36.5% in II (n.s.). CONCLUSION VSG increased primary shunt patency as well as decreased time to and number of TIPS revisions. There was a trend of higher clinical success in VSG without increased hepatic encephalopathy.


Journal of Vascular and Interventional Radiology | 2013

Irreversible electroporation of the pig kidney with involvement of the renal pelvis: technical aspects, clinical outcome, and three-dimensional CT rendering for assessment of the treatment zone.

Christof M. Sommer; Stefan Fritz; Dominik Vollherbst; U Stampfl; Nadine Bellemann; Theresa Gockner; Theresa Mokry; Daniel Gnutzmann; Anne Schmitz; Jürgen Knapp; Thomas Longerich; Clemens Kuhn-Neureuther; Philippe L. Pereira; Hans U. Kauczor; Jens Werner; B Radeleff

PURPOSE To analyze irreversible electroporation (IRE) of the pig kidney with involvement of the renal pelvis. MATERIALS AND METHODS IRE of renal tissue including the pelvis was performed in 10 kidneys in five pigs. Three study groups were defined: group I (two applicators with parallel configuration; n = 11), group II (three applicators with triangular configuration; n = 2), and group III (six applicators with complex configuration; n = 3). After IRE and before euthanasia, pigs underwent contrast-enhanced computed tomography (CT). Technical aspects (radial distance of applicators, resulting mean current), clinical outcome (complications, blood samples), and three-dimensional CT rendering for assessment of the treatment zone (short axis, circularity) were assessed. RESULTS Radial distances of applicators were 14.3 mm ± 2.8 in group I, 12.3 mm ± 1.9 in group II, and 16.4 mm ± 3.5 in group III. Resulting mean currents were 25.7 A ± 6.5 in group I, 27.0 A ± 7.1 in group II, and 39.4 A ± 8.9 in group III. In group III, two perirenal hematomas were identified. There was no damage to the renal pelvis. During IRE, clinical blood parameters and cardiovascular markers did not change significantly. Short axis measurements were 20.6 mm ± 3.6 in group I, 31.9 mm ± 8.2 in group II, and 39.3 mm ± 2.4 in group III (P < .01 between groups). Circularity scores were 0.8 ± 0.2 in group I, 0.7 ± 0.1 in group II, and 0.7 ± 0.1 in group III, with a score of 1 indicating perfect roundness (P value not significant). CONCLUSIONS IRE of the pig kidney with involvement of the renal pelvis is feasible and safe. Size but not shape of the treatment zone is significantly affected by applicator configuration.


Journal of Vascular and Interventional Radiology | 2015

Evaluation of the Plasmatic and Parenchymal Elution Kinetics of Two Different Irinotecan-Loaded Drug-Eluting Embolics in a Pig Model

Daniel Gnutzmann; Julia Mechel; Anne Schmitz; Kernt Köhler; Dorothee Krone; Nadine Bellemann; Theresa Gockner; Theresa Mokry; Nikolas Kortes; Cm Sommer; Hans-Ulrich Kauczor; B Radeleff; U Stampfl

PURPOSE To evaluate and compare irinotecan elution kinetics of two drug-eluting embolic agents in a porcine model. MATERIALS AND METHODS Embolization of the left liver lobe was performed in 16 domestic pigs, with groups of two receiving 1 mL of DC Bead M1 (70-150 µm) or Embozene TANDEM (75 µm) loaded with 50 mg irinotecan. Irinotecan plasma levels were measured at 0, 10, 20, 30, 60, 120, 180, and 240 minutes after completed embolization and at the time of euthanasia (24 h, 48 h, 72 h, or 7 d). Liver tissue samples were taken to measure irinotecan tissue concentrations. RESULTS The highest irinotecan plasma concentrations of both embolic agents were measured 10 and 20 minutes after embolization, and concentrations were significantly higher for DC Bead M1 versus Embozene TANDEM (P = .0019 and P = .0379, respectively). At 48 hours and later follow-up, no irinotecan was measurable in the plasma. For both embolic agents, the highest irinotecan tissue concentration was found after 24 hours and decreased in a time-dependent manner at later follow-up intervals. Additionally, SN-38 tissue levels for both agents were therapeutic at 24 hours, with therapeutic levels of SN-38 at 48 hours in one liver embolized with TANDEM particles. Histopathologic analysis revealed ischemic, inflammatory, and fibrotic tissue reactions. CONCLUSIONS Irinotecan is measurable in plasma and hepatic tissue after liver embolization with both types of irinotecan-eluting embolic agents. DC Bead M1 shows early burst elution kinetics, whereas Embozene TANDEM has a lower and slower release profile. The initial burst is significantly greater after embolization with DC Bead M1 than with Embozene TANDEM.


European Journal of Radiology | 2014

Hepatic artery stent-grafts for the emergency treatment of acute bleeding

Nadine Bellemann; Cm Sommer; Theresa Mokry; Nikolas Kortes; Daniel Gnutzmann; Theresa Gockner; Anne Schmitz; Jürgen Weitz; Hans-Ulrich Kauczor; B Radeleff; U Stampfl

PURPOSE We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. METHODS Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. RESULTS In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n=16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. CONCLUSIONS Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.


Journal of Vascular and Interventional Radiology | 2012

Microwave Ablation in Porcine Livers Applying 5-minute Protocols: Influence of Deployed Energy on Extent and Shape of Coagulation

Christof M. Sommer; Mark Bryant; Nikolas Kortes; U Stampfl; Nadine Bellemann; Theresa Mokry; Theresa Gockner; Hans-Ulrich Kauczor; Philippe L. Pereira; B Radeleff

PURPOSE To evaluate the influence of deployed energy on extent and shape of microwave (MW)-induced coagulation in porcine livers applying 5-minute protocols. MATERIALS AND METHODS MW ablations (n = 25) were performed in ex vivo porcine livers (n = 8). Ablation time was 5 minutes. Five study groups were defined, each with different power output: I, 20 W (n = 5); II, 40 W (n = 5); III, 60 W (n = 5); IV, 80 W (n = 5); and V, 105 W (n = 5). Extent and shape of white coagulation was evaluated macroscopically, including short diameter, volume, front margin, coagulation center (distance between center of short diameter of coagulation and applicator tip), and ellipticity index (short diameter/long diameter). Deployed energy was also analyzed. RESULTS Short diameter and volume were significantly different (P<.001 and P<.001) between the groups: I, 23.0 mm and 11.1 cm(3); II, 12.4 mm and 12.4 cm(3); III, 27.0 mm and 17.6 cm(3); IV, 31.0 mm and 29.2 cm(3); and V, 35.0 mm and 42.3 cm(3). Front margin and coagulation center were also significantly different (P<.05 and P<.001): I, 6.0 mm and 13.0 mm; II, 8.0 mm and 11.0 mm; III, 8.0 mm and 14.0 mm; IV, 8.0 mm and 18.0 mm; and V, 10.0 mm and 19.0 mm. Ellipticity index was not significantly different. Deployed energy was significantly different (P<.001): I, 5.7 kJ; II, 11.0 kJ; III, 15.5 kJ; IV, 21.6 kJ; and V, 26.6 kJ. CONCLUSIONS Extent, but not shape, of MW-induced coagulation depends on the deployed energy. Applying the protocols described in this study, significantly different coagulation volumes can be created with an ablation time of 5 minutes but different power output.


Journal of Biomaterials Applications | 2018

In vivo characterization of a new type of biodegradable starch microsphere for transarterial embolization

Christof M. Sommer; Thuy Do; Christopher L. Schlett; Paul Flechsig; Theresa Gockner; Anja Kuthning; Dominik F. Vollherbst; Philippe L. Pereira; Hans U. Kauczor; Stephan Macher-Göppinger

Transarterial embolization is an established minimally invasive treatment for solid tumors. Unintended inflammation, foreign body reactions and ischemia-triggered neoangiogenesis are clinical drawbacks of permanent embolic materials. The aim of the current study was to characterize a new type of biodegradable starch microsphere with regard to angiographic and histopathological features such as patterns of acute arterial occlusion as well as induction of tissue necrosis, microsphere biodegradation, and inflammation and foreign body reactions during follow-up. Key characteristics of both biodegradable prototypes (L1 and L2; prototype groups) were as follows: microspheres are biodegradable by serum α-amylase, produced from chemically crosslinked potato starch to different extents, in a diameter range of ∼300–800 µm, differing in size distribution and featuring a microsphere deformation of ∼1%. In vivo transarterial embolization with L1 and L2, while applying clinical standard techniques, was performed and compared with clinically established permanent microspheres (Embosphere®500-700 and Embosphere®700-900; control groups). Twenty-four pig kidneys were embolized with the different embolic materials by following the study protocol, and there were no technical failures or complications. Parenchymal necrosis with interstitial calcification was observed in all kidneys independent of the type of embolic material used. Compared with the permanent embolic materials, biodegradable microspheres showed complete (L1) or partial (L2) biodegradation within one week after transarterial embolization, and induced a comparable (L1) or a lower (L2) degree of arterial wall necrosis and a lower degree of inflammation and foreign body reactions. In conclusion, the presented new type of biodegradable microsphere is promising, and could be further evaluated in terms of clinical translation.


PLOS ONE | 2018

Computed tomography and histopathological findings after embolization with inherently radiopaque 40μm-microspheres, standard 40μm-microspheres and iodized oil in a porcine liver model

Dominik F. Vollherbst; Theresa Gockner; Thuy Do; Kerstin Holzer; Carolin Mogler; Paul Flechsig; Alexander Harms; Christopher L. Schlett; Philippe L. Pereira; Götz M. Richter; Hans U. Kauczor; Christof M. Sommer

Purpose The present study compared standard computed tomography (CT) and histopathological findings after endovascular embolization using a prototype of inherently radiopaque 40μm-microspheres with both standard 40μm-microspheres and iodized oil in a porcine liver model. Materials and methods Twelve pigs were divided into six study groups, of two pigs each. Four pigs were embolized with iodized oil alone and four with radiopaque microspheres; two animals in each group were sacrificed at 2 hours and two at 7 days. Two pigs were embolized with radiopaque microspheres and heparin and sacrificed at 7 days. Two pigs were embolized with standard microspheres and sacrificed at 2 hours. CT was performed before and after segmental embolization and before sacrifice at 7 days. The distribution of embolic agent, inflammatory response and tissue necrosis were assessed histopathologically. Results Radiopaque microspheres and iodized oil were visible on standard CT 2 hours and 7 days after embolization, showing qualitatively comparable arterial and parenchymal enhancement. Quantitatively, the enhancement was more intense for iodized oil. Standard microspheres, delivered without contrast, were not visible by imaging. Radiopaque and standard microspheres similarly occluded subsegmental and interlobular arteries and, to a lesser extent, sinusoids. Iodized oil resulted in the deepest penetration into sinusoids. Necrosis was always observed after embolization with microspheres, but never after embolization with iodized oil. The inflammatory response was mild to moderate for microspheres and moderate to severe for iodized oil. Conclusion Radiopaque 40μm-microspheres are visible on standard CT with qualitatively similar but quantitatively less intense enhancement compared to iodized oil, and with a tendency towards less of an inflammatory reaction than iodized oil. These microspheres also result in tissue necrosis, which was not observed after embolization with iodized oil. Both radiopaque and standard 40μm-microspheres are found within subsegmental and interlobar arteries, as well as in hepatic sinusoids.


CardioVascular and Interventional Radiology | 2015

CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

Cm Sommer; Stefan Fritz; Dominik Vollherbst; Sascha Zelzer; Nadine Bellemann; Theresa Gockner; Theresa Mokry; Anne Schmitz; S. Aulmann; U Stampfl; Philippe L. Pereira; Hu Kauczor; Jens Werner; B Radeleff


Emergency Radiology | 2014

Emergency embolization for the treatment of acute hemorrhage from intercostal arteries.

U Stampfl; Cm Sommer; Nadine Bellemann; Nikolas Kortes; Daniel Gnutzmann; Theresa Mokry; Theresa Gockner; Anne Schmitz; Katja Ott; Hans-Ulrich Kauczor; B Radeleff

Collaboration


Dive into the Theresa Gockner's collaboration.

Top Co-Authors

Avatar

B Radeleff

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Nadine Bellemann

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

U Stampfl

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Theresa Mokry

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Anne Schmitz

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Christof M. Sommer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Daniel Gnutzmann

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Cm Sommer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Hans U. Kauczor

University Hospital Heidelberg

View shared research outputs
Researchain Logo
Decentralizing Knowledge