Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Thomas K. Chung is active.

Publication


Featured researches published by Thomas K. Chung.


Clinical Cancer Research | 2015

Safety and Tumor-specificity of Cetuximab-IRDye800 for Surgical Navigation in Head and Neck Cancer

Eben L. Rosenthal; Jason M. Warram; Esther de Boer; Thomas K. Chung; Melissa L. Korb; Margie Brandwein-Gensler; Theresa V. Strong; Cecelia E. Schmalbach; Anthony Morlandt; Garima Agarwal; Yolanda E. Hartman; William R. Carroll; Joshua S. Richman; Lisa Clemons; Lisle Nabell; Kurt R. Zinn

Purpose: Positive margins dominate clinical outcomes after surgical resections in most solid cancer types, including head and neck squamous cell carcinoma. Unfortunately, surgeons remove cancer in the same manner they have for a century with complete dependence on subjective tissue changes to identify cancer in the operating room. To effect change, we hypothesize that EGFR can be targeted for safe and specific real-time localization of cancer. Experimental Design: A dose escalation study of cetuximab conjugated to IRDye800 was performed in patients (n = 12) undergoing surgical resection of squamous cell carcinoma arising in the head and neck. Safety and pharmacokinetic data were obtained out to 30 days after infusion. Multi-instrument fluorescence imaging was performed in the operating room and in surgical pathology. Results: There were no grade 2 or higher adverse events attributable to cetuximab-IRDye800. Fluorescence imaging with an intraoperative, wide-field device successfully differentiated tumor from normal tissue during resection with an average tumor-to-background ratio of 5.2 in the highest dose range. Optical imaging identified opportunity for more precise identification of tumor during the surgical procedure and during the pathologic analysis of tissues ex vivo. Fluorescence levels positively correlated with EGFR levels. Conclusions: We demonstrate for the first time that commercially available antibodies can be fluorescently labeled and safely administered to humans to identify cancer with sub-millimeter resolution, which has the potential to improve outcomes in clinical oncology. Clin Cancer Res; 21(16); 3658–66. ©2015 AACR.


Laryngoscope | 2015

Transoral robotic surgery for oropharyngeal and tongue cancer in the United States.

Thomas K. Chung; Eben L. Rosenthal; J. Scott Magnuson; William R. Carroll

To compare the clinical and cost outcomes of transoral robotic surgery (TORS) versus open procedures following the U.S. Food and Drug Administration approval in December 2009.


Scientific Reports | 2015

In Vivo Fluorescence Immunohistochemistry: Localization of Fluorescently Labeled Cetuximab in Squamous Cell Carcinomas

Esther de Boer; Jason M. Warram; Matthew D. Tucker; Yolanda E. Hartman; Lindsay S. Moore; Johannes S. de Jong; Thomas K. Chung; Melissa L. Korb; Kurt R. Zinn; Gooitzen M. van Dam; Eben L. Rosenthal; Margaret Brandwein-Gensler

Anti-EGFR (epidermal growth factor receptor) antibody based treatment strategies have been successfully implemented in head and neck squamous cell carcinoma (HNSCC). Unfortunately, predicting an accurate and reliable therapeutic response remains a challenge on a per-patient basis. Although significant efforts have been invested in understanding EGFR-mediated changes in cell signaling related to treatment efficacy, the delivery and histological localization in (peri-)tumoral compartments of antibody-based therapeutics in human tumors is poorly understood nor ever made visible. In this first in-human study of a systemically administered near-infrared (NIR) fluorescently labeled therapeutic antibody, cetuximab-IRDye800CW (2.5 mg/m2, 25 mg/m2, and 62.5 mg/m2), we show that by optical molecular imaging (i.e. denominated as In vivo Fluorescence Immunohistochemistry) we were able to evaluate localization of fluorescently labeled cetuximab. Clearly, optical molecular imaging with fluorescently labeled antibodies correlating morphological (peri-)tumoral characteristics to levels of antibody delivery, may improve treatment paradigms based on understanding true tumoral antibody delivery.


Cancer and Metastasis Reviews | 2014

Antibody-based imaging strategies for cancer

Jason M. Warram; Esther de Boer; Anna G. Sorace; Thomas K. Chung; Hyunki Kim; Rick G. Pleijhuis; Gooitzen M. van Dam; Eben L. Rosenthal

Although mainly developed for preclinical research and therapeutic use, antibodies have high antigen specificity, which can be used as a courier to selectively deliver a diagnostic probe or therapeutic agent to cancer. It is generally accepted that the optimal antigen for imaging will depend on both the expression in the tumor relative to normal tissue and the homogeneity of expression throughout the tumor mass and between patients. For the purpose of diagnostic imaging, novel antibodies can be developed to target antigens for disease detection, or current FDA-approved antibodies can be repurposed with the covalent addition of an imaging probe. Reuse of therapeutic antibodies for diagnostic purposes reduces translational costs since the safety profile of the antibody is well defined and the agent is already available under conditions suitable for human use. In this review, we will explore a wide range of antibodies and imaging modalities that are being translated to the clinic for cancer identification and surgical treatment.


Journal of The American College of Surgeons | 2014

Examining National Outcomes after Thyroidectomy with Nerve Monitoring

Thomas K. Chung; Eben L. Rosenthal; John R. Porterfield; William R. Carroll; Joshua S. Richman; Mary T. Hawn

Background Previous IONM studies have demonstrated modest-to-no benefit and did not include a nationwide sample of hospitals representative of broad thyroidectomy practices. This national study was designed to compare vocal cord paralysis (VCP) rates between thyroidectomy with IONM and without monitoring (Conventional). Study Design We performed a retrospective analysis of 243,527 thyroidectomies during 2008-2011 using the Nationwide Inpatient Sample. Results IONM utilization increased throughout the study period (2.6%, 5.6%, 6.1%, 6.9%) and during this time, VCP rates in the IONM group initially increased year-over-year [0.9%(2008), 2.4%(2009), 2.5%(2010), 1.4%(2011)]. In unadjusted analyses, IONM was associated with significantly higher VCP rates (Conventional 1.4% vs IONM 1.9%, p<0.001). After propensity score matching, IONM remained associated with higher VCP rates in partial thyroidectomy and lower VCP rates for total thyroidectomy with neck dissection. Hospital-level analysis revealed that VCP rates were not explained by differential laryngoscopy rates, decreasing the likelihood of ascertainment bias. Additionally, for hospitals where IONM was applied to >50% of thyroidectomies, lower VCP rates were observed (1.1%) compared to hospitals that applied IONM to <50% (1.6%,p=0.016). Higher hospital volume correlated with lower VCP rates in both groups (<75, 75-299, >300 thyroidectomies/year: IONM-2.1%, 1.7%, 1.7%, conventional-1.5%, 1.3%, 1.0%). Conclusions According to this study, IONM has not been broadly adopted into practice. Overall, IONM was associated with a higher rate of VCP even after correction for numerous confounders. In particular, low institutional utilization of IONM and use in partial thyroidectomies is associated with higher rates of VCP. Further studies are warranted to support the broader application of IONM in patients where benefit can be reliably achieved.


Journal of Minimally Invasive Gynecology | 2015

Laparoscopic Fluorescent Visualization of the Ureter With Intravenous IRDye800CW

Melissa L. Korb; Warner K. Huh; Jonathan D. Boone; Jason M. Warram; Thomas K. Chung; Esther de Boer; Kirby I. Bland; Eben L. Rosenthal

OBJECTIVES Ureter injury is a serious complication of laparoscopic surgery. Current strategies to identify the ureters, such as placement of a ureteral stent, carry additional risks for patients. We hypothesize that the systemically injected near-infrared (NIR) dye IRDye800CW-CA can be used to visualize ureters intraoperatively. METHODS Adult female mixed-breed pigs weighing 24 to 41 kg (n = 2 per dose) were given a 30, 60, or 120 μg/kg systemic injection of IRDye800CW-CA. Using the Food and Drug Administration-cleared Pinpoint laparoscopic NIR system, images of the ureter and bladder were captured every 10 minutes for 60 minutes after injection. To determine the biodistribution of the dye, tissues were collected for ex vivo analysis with the Pearl Impulse system. ImageJ software was used to quantify fluorescence signal and signal-to-background ratio (SBR) for the intraoperative images. RESULTS The ureter was identified in all pigs at each dose, with peak intensity reached by 30 minutes and remaining elevated throughout the duration of imaging (60 minutes). The 60 μg/kg dose was determined to be optimal for differentiating ureters according to absolute fluorescence (>60 counts/pixel) and SBR (3.1). Urine fluorescence was inversely related to plasma fluorescence (R(2) = -0.82). Ex vivo imaging of kidney, ureter, bladder, and abdominal wall tissues revealed low fluorescence. CONCLUSION Systemic administration of IRDye800CW-CA shows promise in providing ureteral identification with high specificity during laparoscopic surgery. The low dose required, rapid time to visualization, and absence of invasive ureteral instrumentation inherent to this technique may reduce complications related to pelvic surgery.


Annals of Oncology | 2015

Phase I dose-escalating trial of Escherichia coli purine nucleoside phosphorylase and fludarabine gene therapy for advanced solid tumors

Eben L. Rosenthal; Thomas K. Chung; William B. Parker; P. W. Allan; Lisa Clemons; Deborah Lowman; Jeong Hong; F. R. Hunt; Joshua S. Richman; Robert M. Conry; K. Mannion; William R. Carroll; Lisle Nabell; Eric J. Sorscher

BACKGROUND The use of Escherichia coli purine nucleoside phosphorylase (PNP) to activate fludarabine has demonstrated safety and antitumor activity during preclinical analysis and has been approved for clinical investigation. PATIENTS AND METHODS A first-in-human phase I clinical trial (NCT 01310179; IND 14271) was initiated to evaluate safety and efficacy of an intratumoral injection of adenoviral vector expressing E. coli PNP in combination with intravenous fludarabine for the treatment of solid tumors. The study was designed with escalating doses of fludarabine in the first three cohorts (15, 45, and 75 mg/m(2)) and escalating virus in the fourth (10(11)-10(12) viral particles, VP). RESULTS All 12 study subjects completed therapy without dose-limiting toxicity. Tumor size change from baseline to final measurement demonstrated a dose-dependent response, with 5 of 6 patients in cohorts 3 and 4 achieving significant tumor regression compared with 0 responsive subjects in cohorts 1 and 2. The overall adverse event rate was not dose-dependent. Most common adverse events included pain at the viral injection site (92%), drainage/itching/burning (50%), fatigue (50%), and fever/chills/influenza-like symptoms (42%). Analysis of serum confirmed the lack of systemic exposure to fluoroadenine. Antibody response to adenovirus was detected in two patients, suggesting that neutralizing immune response is not a barrier to efficacy. CONCLUSIONS This first-in-human clinical trial found that localized generation of fluoroadenine within tumor tissues using E. coli PNP and fludarabine is safe and effective. The pronounced effect on tumor volume after a single treatment cycle suggests that phase II studies are warranted. CLINICALTRIALSGOV IDENTIFIER NCT01310179.


The Journal of Nuclear Medicine | 2017

Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients

Lindsay S. Moore; Eben L. Rosenthal; Thomas K. Chung; Esther de Boer; Neel Patel; Andrew C. Prince; Melissa L. Korb; Erika M. Walsh; E. Scott Young; Todd M. Stevens; Kirk P. Withrow; Anthony Morlandt; Joshua S. Richman; William R. Carroll; Kurt R. Zinn; Jason M. Warram

The purpose of this study was to assess the potential of U.S. Food and Drug Administration–cleared devices designed for indocyanine green–based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Methods: Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. Results: In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2–14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P < 0.001). The repurposed device also successfully identified positive margins. Conclusion: The open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery.


Cancer Biology & Therapy | 2015

Time-dependent pretreatment with bevacuzimab increases tumor specific uptake of cetuximab in preclinical oral cavity cancer studies

Thomas K. Chung; Jason M. Warram; Kristine E. Day; Yolanda E. Hartman; Eben L. Rosenthal

Inadequate delivery of therapeutics into tumors has been suggested as a reason for poor response. We hypothesize that bevacizumab, an antibody to vascular endothelial growth factor (VEGF), can improve cetuximab uptake in squamous cell carcinoma tumors. Athymic nude mice were implanted with OSC19 and SCC1 human cancer lines in a subcutaneous flank model. Mice were imaged daily for 14 days after intravenous tail vein injections of the following groups: IgG-IRDye800 (Control), cetuximab-IRDye800 (CTX800 Only), bevacizumab-IRDye800 (BVZ800 Only), cetuximab-IRDye800 + bevacuzimuab-IRDye800 (Simultaneous), and unlabeled bevacizumab followed by cetuximab-IRDye800 3 days later (Neoadjuvant). Within single-agent groups, the CTX800 Only tumor-specific uptake (TSU) was significantly higher than BVZ800 Only at Day 13 (TSU 8.6 vs 2.8, P < 0.001). The Simultaneous treatment with BVZ800 and CTX800 demonstrated no increase in antibody delivery. However, administration of unlabeled bevacizumab 3 days prior to CTX800 (Neoadjuvant group) resulted in significantly higher tumor specific delivery than administration of both antibodies at the same time (11.8 vs Simultaneous 5.0, P < 0.001). This difference can be attributed to a slower decline in tumor fluorescence intensity (−6.8% vs. Simultaneous −11.5% per day, respectively). Structural changes in pericyte coverage and functional vessel changes demonstrating decreased proliferation and tumor growth corroborate these fluorescence results. Although simultaneous administration of bevacizumab with cetuximab failed to increase antibody delivery to the tumor, pretreatment with bevacizumab improved TSU reflecting an increase in tumor-specific uptake of cetuximab as a result of vessel normalization.


Journal of Magnetic Resonance Imaging | 2015

Dynamic contrast-enhanced MRI evaluates the early response of human head and neck tumor xenografts following anti-EMMPRIN therapy with cisplatin or irradiation

Hyunki Kim; Yolanda E. Hartman; Guihua Zhai; Thomas K. Chung; Melissa L. Korb; T. Beasley; Tong Zhou; Eben L. Rosenthal

To assess the early therapeutic effects of anti‐EMMPRIN (extracellular matrix metalloprotease inducer) antibody with/without cisplatin or X‐ray radiation in head and neck cancer mouse models using dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI).

Collaboration


Dive into the Thomas K. Chung's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jason M. Warram

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Joshua S. Richman

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Melissa L. Korb

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Esther de Boer

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Kurt R. Zinn

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Lisa Clemons

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Lisle Nabell

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar

Yolanda E. Hartman

University of Alabama at Birmingham

View shared research outputs
Researchain Logo
Decentralizing Knowledge