Tim Mullen
University of California, San Diego
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Tim Mullen.
Computational Intelligence and Neuroscience | 2011
Arnaud Delorme; Tim Mullen; Christian Kothe; Zeynep Acar; Nima Bigdely-Shamlo; Andrey Vankov; Scott Makeig
We describe a set of complementary EEG data collection and processing tools recently developed at the Swartz Center for Computational Neuroscience (SCCN) that connect to and extend the EEGLAB software environment, a freely available and readily extensible processing environment running under Matlab. The new tools include (1) a new and flexible EEGLAB STUDY design facility for framing and performing statistical analyses on data from multiple subjects; (2) a neuroelectromagnetic forward head modeling toolbox (NFT) for building realistic electrical head models from available data; (3) a source information flow toolbox (SIFT) for modeling ongoing or event-related effective connectivity between cortical areas; (4) a BCILAB toolbox for building online brain-computer interface (BCI) models from available data, and (5) an experimental real-time interactive control and analysis (ERICA) environment for real-time production and coordination of interactive, multimodal experiments.
Proceedings of the IEEE | 2012
Scott Makeig; Christian Kothe; Tim Mullen; Nima Bigdely-Shamlo; Zhilin Zhang; Kenneth Kreutz-Delgado
Because of the increasing portability and wearability of noninvasive electrophysiological systems that record and process electrical signals from the human brain, automated systems for assessing changes in user cognitive state, intent, and response to events are of increasing interest. Brain-computer interface (BCI) systems can make use of such knowledge to deliver relevant feedback to the user or to an observer, or within a human-machine system to increase safety and enhance overall performance. Building robust and useful BCI models from accumulated biological knowledge and available data is a major challenge, as are technical problems associated with incorporating multimodal physiological, behavioral, and contextual data that may in the future be increasingly ubiquitous. While performance of current BCI modeling methods is slowly increasing, current performance levels do not yet support widespread uses. Here we discuss the current neuroscientific questions and data processing challenges facing BCI designers and outline some promising current and future directions to address them.
Frontiers in Neuroinformatics | 2015
Nima Bigdely-Shamlo; Tim Mullen; Christian Kothe; Kyung Min Su; Kay A. Robbins
The technology to collect brain imaging and physiological measures has become portable and ubiquitous, opening the possibility of large-scale analysis of real-world human imaging. By its nature, such data is large and complex, making automated processing essential. This paper shows how lack of attention to the very early stages of an EEG preprocessing pipeline can reduce the signal-to-noise ratio and introduce unwanted artifacts into the data, particularly for computations done in single precision. We demonstrate that ordinary average referencing improves the signal-to-noise ratio, but that noisy channels can contaminate the results. We also show that identification of noisy channels depends on the reference and examine the complex interaction of filtering, noisy channel identification, and referencing. We introduce a multi-stage robust referencing scheme to deal with the noisy channel-reference interaction. We propose a standardized early-stage EEG processing pipeline (PREP) and discuss the application of the pipeline to more than 600 EEG datasets. The pipeline includes an automatically generated report for each dataset processed. Users can download the PREP pipeline as a freely available MATLAB library from http://eegstudy.org/prepcode.
international conference of the ieee engineering in medicine and biology society | 2013
Tim Mullen; Christian Kothe; Yu Mike Chi; Alejandro Ojeda; Trevor Kerth; Scott Makeig; Gert Cauwenberghs; Tzyy-Ping Jung
This report summarizes our recent efforts to deliver real-time data extraction, preprocessing, artifact rejection, source reconstruction, multivariate dynamical system analysis (including spectral Granger causality) and 3D visualization as well as classification within the open-source SIFT and BCILAB toolboxes. We report the application of such a pipeline to simulated data and real EEG data obtained from a novel wearable high-density (64-channel) dry EEG system.
IEEE Transactions on Biomedical Engineering | 2015
Tim Mullen; Christian Kothe; Yu Mike Chi; Alejandro Ojeda; Trevor Kerth; Scott Makeig; Tzyy-Ping Jung; Gert Cauwenberghs
Goal: We present and evaluate a wearable high-density dry-electrode EEG system and an open-source software framework for online neuroimaging and state classification. Methods: The system integrates a 64-channel dry EEG form factor with wireless data streaming for online analysis. A real-time software framework is applied, including adaptive artifact rejection, cortical source localization, multivariate effective connectivity inference, data visualization, and cognitive state classification from connectivity features using a constrained logistic regression approach (ProxConn). We evaluate the system identification methods on simulated 64-channel EEG data. Then, we evaluate system performance, using ProxConn and a benchmark ERP method, in classifying response errors in nine subjects using the dry EEG system. Results: Simulations yielded high accuracy (AUC = 0.97 ± 0.021) for real-time cortical connectivity estimation. Response error classification using cortical effective connectivity [short-time directdirected transfer function (sdDTF)] was significantly above chance with similar performance (AUC) for cLORETA (0.74 ± 0.09) and LCMV (0.72 ± 0.08) source localization. Cortical ERPbased classification was equivalent to ProxConn for cLORETA (0.74 ± 0.16) butsignificantlybetterforLCMV (0.82 ± 0.12). Conclusion: We demonstrated the feasibility for real-time cortical connectivity analysis and cognitive state classification from highdensity wearable dry EEG. Significance: This paper is the first validated application of these methods to 64-channel dry EEG. This study addresses a need for robust real-time measurement and interpretation of complex brain activity in the dynamic environment of the wearable setting. Such advances can have broad impact in research, medicine, and brain-computer interfaces. The pipelines are made freely available in the open-source SIFT and BCILAB toolboxes.
NeuroImage | 2013
Nima Bigdely-Shamlo; Tim Mullen; Kenneth Kreutz-Delgado; Scott Makeig
A crucial question for the analysis of multi-subject and/or multi-session electroencephalographic (EEG) data is how to combine information across multiple recordings from different subjects and/or sessions, each associated with its own set of source processes and scalp projections. Here we introduce a novel statistical method for characterizing the spatial consistency of EEG dynamics across a set of data records. Measure Projection Analysis (MPA) first finds voxels in a common template brain space at which a given dynamic measure is consistent across nearby source locations, then computes local-mean EEG measure values for this voxel subspace using a statistical model of source localization error and between-subject anatomical variation. Finally, clustering the mean measure voxel values in this locally consistent brain subspace finds brain spatial domains exhibiting distinguishable measure features and provides 3-D maps plus statistical significance estimates for each EEG measure of interest. Applied to sufficient high-quality data, the scalp projections of many maximally independent component (IC) processes contributing to recorded high-density EEG data closely match the projection of a single equivalent dipole located in or near brain cortex. We demonstrate the application of MPA to a multi-subject EEG study decomposed using independent component analysis (ICA), compare the results to k-means IC clustering in EEGLAB (sccn.ucsd.edu/eeglab), and use surrogate data to test MPA robustness. A Measure Projection Toolbox (MPT) plug-in for EEGLAB is available for download (sccn.ucsd.edu/wiki/MPT). Together, MPA and ICA allow use of EEG as a 3-D cortical imaging modality with near-cm scale spatial resolution.
Annals of Biomedical Engineering | 2014
Frédéric D. Broccard; Tim Mullen; Yu Mike Chi; David A. Peterson; John R. Iversen; Mike Arnold; Kenneth Kreutz-Delgado; Tzyy-Ping Jung; Scott Makeig; Howard Poizner; Terrence J. Sejnowski; Gert Cauwenberghs
Traditional approaches for neurological rehabilitation of patients affected with movement disorders, such as Parkinson’s disease (PD), dystonia, and essential tremor (ET) consist mainly of oral medication, physical therapy, and botulinum toxin injections. Recently, the more invasive method of deep brain stimulation (DBS) showed significant improvement of the physical symptoms associated with these disorders. In the past several years, the adoption of feedback control theory helped DBS protocols to take into account the progressive and dynamic nature of these neurological movement disorders that had largely been ignored so far. As a result, a more efficient and effective management of PD cardinal symptoms has emerged. In this paper, we review closed-loop systems for rehabilitation of movement disorders, focusing on PD, for which several invasive and noninvasive methods have been developed during the last decade, reducing the complications and side effects associated with traditional rehabilitation approaches and paving the way for tailored individual therapeutics. We then present a novel, transformative, noninvasive closed-loop framework based on force neurofeedback and discuss several future developments of closed-loop systems that might bring us closer to individualized solutions for neurological rehabilitation of movement disorders.
international conference of the ieee engineering in medicine and biology society | 2011
Tim Mullen; Zeynep Acar; Gregory A. Worrell; Scott Makeig
Mapping the dynamics and spatial topography of brain source processes critically involved in initiating and propagating seizure activity is critical for effective epilepsy diagnosis, intervention, and treatment. In this report we analyze neuronal dynamics before and during epileptic seizures using adaptive multivariate autoregressive (VAR) models applied to maximally-independent (ICA) sources of intracranial EEG (iEEG, ECoG) data recorded from subdural electrodes implanted in a human patient for evaluation of surgery for epilepsy. We visualize the spatial distribution of causal sources and sinks of ictal activity on the cortical surface (gyral and sulcal) using a novel combination of multivariate Granger-causal and graph-theoretic metrics combined with distributed source localization by Sparse Bayesian Learning applied to a multi-scale patch basis. This analysis reveals and visualizes distinct, seizure stage-dependent shifts in inter-component spatiotemporal dynamics and connectivity including the clinically-identified epileptic foci.
IEEE Transactions on Neural Systems and Rehabilitation Engineering | 2016
Sheng-Hsiou Hsu; Tim Mullen; Tzyy-Ping Jung; Gert Cauwenberghs
Independent component analysis (ICA) has been widely applied to electroencephalographic (EEG) biosignal processing and brain-computer interfaces. The practical use of ICA, however, is limited by its computational complexity, data requirements for convergence, and assumption of data stationarity, especially for high-density data. Here we study and validate an optimized online recursive ICA algorithm (ORICA) with online recursive least squares (RLS) whitening for blind source separation of high-density EEG data, which offers instantaneous incremental convergence upon presentation of new data. Empirical results of this study demonstrate the algorithms: 1) suitability for accurate and efficient source identification in high-density (64-channel) realistically-simulated EEG data; 2) capability to detect and adapt to nonstationarity in 64-ch simulated EEG data; and 3) utility for rapidly extracting principal brain and artifact sources in real 61-channel EEG data recorded by a dry and wearable EEG system in a cognitive experiment. ORICA was implemented as functions in BCILAB and EEGLAB and was integrated in an open-source Real-time EEG Source-mapping Toolbox (REST), supporting applications in ICA-based online artifact rejection, feature extraction for real-time biosignal monitoring in clinical environments, and adaptable classifications in brain-computer interfaces.
NeuroImage | 2017
Javier O. Garcia; Justin Brooks; Scott E. Kerick; Tony Johnson; Tim Mullen; Jean M. Vettel
Abstract Conventional neuroimaging analyses have ascribed function to particular brain regions, exploiting the power of the subtraction technique in fMRI and event‐related potential analyses in EEG. Moving beyond this convention, many researchers have begun exploring network‐based neurodynamics and coordination between brain regions as a function of behavioral parameters or environmental statistics; however, most approaches average evoked activity across the experimental session to study task‐dependent networks. Here, we examined on‐going oscillatory activity as measured with EEG and use a methodology to estimate directionality in brain‐behavior interactions. After source reconstruction, activity within specific frequency bands (delta: 2–3 Hz; theta: 4–7 Hz; alpha: 8–12 Hz; beta: 13–25 Hz) in a priori regions of interest was linked to continuous behavioral measurements, and we used a predictive filtering scheme to estimate the asymmetry between brain‐to‐behavior and behavior‐to‐brain prediction using a variant of Granger causality. We applied this approach to a simulated driving task and examined directed relationships between brain activity and continuous driving performance (steering behavior or vehicle heading error). Our results indicated that two neuro‐behavioral states may be explored with this methodology: a Proactive brain state that actively plans the response to the sensory information and is characterized by delta‐beta activity, and a Reactive brain state that processes incoming information and reacts to environmental statistics primarily within the alpha band. Graphical abstract Figure. No Caption available. HighlightsTraditional neuroscience studies investigate localized task‐evoked responsesOur approach examines continuous tracking of brain‐behavior interactions in oscillatory activityBrain leads behavior in a Proactive state, while brain follows behavior in a Reactive stateReactive states are largely carried by alpha activity in regions sensitive to environmental statisticsProactive states rely more on a diffuse delta‐beta network, particularly when linked with steering behavior