Tomio Yamashita
Yamaguchi University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Tomio Yamashita.
Nuclear Medicine Communications | 2004
Kazuyoshi Suga; Yasuhiko Kawakami; Mohammed Zaki; Tomio Yamashita; Tsuneo Matsumoto; Naofumi Matsunaga
PurposeRespiratory gated perfusion single photon emission computed tomography (SPECT) was applied to reduce respiratory lung motion effects and to reliably assess perfusion impairment in various lung diseases. MethodsAfter injection of 259 MBq of 99mTc macroaggretated albumin (99mTc-MAA), gating was performed using a triple-headed SPECT unit connected to a physiological synchronizer in a total of 35 patients with either obstructive lung diseases (n=14), pulmonary embolism (n=8), small lung nodules (n=7) or acute interstitial pneumonia (n=6). Projection data were acquired in a 64×64 matrix, with 20 stops over 120° for each detector with a preset time of 15 s for each stop. Inadequate data for the respiratory cycle were automatically eliminated. In addition to end inspiration images and end expiration images derived from 12.5% threshold data centred at peak inspiration and expiration for each respiratory cycle, respectively, an ungated image was obtained from full respiratory cycle data. ResultsGated images were completed for 13.7±1.8 min in all subjects. Although the total lung radioactivity of the gated images were reduced to approximately 13% of that of the ungated images, these gated images showed uniform perfusion in the unaffected lungs and visualized a total of 94 (21.9%) additional perfusion defects against 429 defects visualized on ungated images in 31 patients with focal perfusion defects. Among the perfusion defects visualized on both gated images, the defect size was occasionally larger on the end inspiration images. The end expiration images showed significantly higher lesion-to-normal lung radioactivity ratios compared with those on the end expiration and ungated images in the affected lower lungs throughout the lung diseases. Radioactivity changes per pixel between end inspiration and end expiration images in the affected lower lungs of the obstructive lung diseases were significantly lower compared with those of pulmonary embolism and acute interstitial pneumonia (P<0.0001 and P<0.01, respectively). ConclusionThis technique appears to enhance the clarity of perfusion defects, and lung radioactivity changes between end inspiration and end expiration may characterize regionally impaired ventilation status.
Nuclear Medicine Communications | 2005
Mohammed Zaki; Kazuyoshi Suga; Yasuhiko Kawakami; Tomio Yamashita; Kensaku Shimizu; Aska Seto; Naofumi Matsunaga
PurposePreferential location of acute pulmonary thromboembolism (PTE) induced consolidative opacities (infarction/atelectasis) was determined on respiratory gated perfusion SPECT–CT fusion images. MethodGated end-inspiratory perfusion SPECT images were obtained in 21 patients with acute PTE and 17 patients with inflammatory diseases, using a triple-headed SPECT system and a respiratory tracking device. Anatomical relationships of consolidative opacities and perfusion defects were assessed on gated SPECT–rest inspiratory CT fusion images. The size and radioactivity of perfusion defects with acute PTE consolidative opacities were compared with those of defects without these opacities. The contribution of fusion images for differential diagnosis of acute PTE induced and inflammatory disease induced lesions was evaluated by receiver operating characteristic (ROC) curve analysis. ResultsOf the total 56 acute PTE induced consolidative opacities, 42 (75%) were located at the peripheral interface between the severely decreased and adjacent relatively preserved perfusion areas within wedge shaped perfusion defects on fusion images. These defects with consolidative opacities were significantly larger and had taken up less radioactivity compared with those in the 86 defects without these lesions (P<0.0001). In contrast, of the 29 inflammatory disease induced opacities, 14 (48.2%) had the matched defects and 13 (44.8%) were located at the proximal portion of defects. These preferential locations of acute PTE induced and inflammation induced lesions were significantly different (P<0.01). In ROC curves, the combined reading of fusion images showed a significantly higher differential diagnostic accuracy compared with the reading of CT and SPECT images alone (P<0.01). ConclusionsAcute PTE induced consolidative opacities preferentially occur at the peripheral lung interface between severely decreased and adjacent relatively preserved perfusion areas within relatively large and severely decreased perfusion defects. The fusion images, which provide an accurate assessment of the morphological–perfusion defect relationship could, potentially, provide a differential diagnosis between acute PTE induced and inflammatory disease induced lesions.
American Journal of Roentgenology | 2006
Toshinobu Tsukuda; Takeshi Fujita; Katsuyoshi Ito; Tomio Yamashita; Naofumi Matsunaga
OBJECTIVE The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy with endoscopic push-type gastrostomy tubes using CT and fluoroscopic guidance. CONCLUSION Percutaneous radiologic gastrostomy using CT and fluoroscopic guidance with push-type tubes is a safe and effective means of gastric feeding that has few complications and offers an alternative to introducer-placed gastrostomy tubes.
Nuclear Medicine Communications | 2005
Yasuhiko Kawakami; Kazuyoshi Suga; Tomio Yamashita; Hideyuki Iwanaga; Mohammed Zaki; Naofumi Matsunaga
AimRespiratory-gated thallium-201 chloride (201Tl) single photon emission computed tomography (SPECT) was used in preliminary investigations to reduce the adverse respiratory motion effects observed on standard ungated SPECT images and to obtain reliable fusion images with computed tomography (CT) in patients with malignant lung tumours. MethodsFifteen patients with primary lung cancer (n=10) or metastatic lung tumours (n=5) underwent gated SPECT 20 min after intravenous injection of 148 MBq 201Tl, using triple-headed SPECT and laser light respiratory tracking units. Projection data were acquired by a step and shoot mode, with 20 stops over 120° for each detector and a preset time of 30 s for each 6° stop. Gated end-inspiratory and ungated images were obtained from 1/8 data centred at peak inspiration for each regular respiratory cycle and for the full respiratory cycle data, respectively. The degree and size of tumour 201Tl uptake were compared between these images by regions of interest (ROI) analysis. Gated SPECT images were registered with rest inspiratory CT images using an automated three-dimensional (3D) image registration tool. Registration mismatch was assessed by measuring the 3D distance of the centroid of 14 201Tl-avid peripheral tumours. Attenuation correction of gated SPECT images was performed using CT attenuation values of these fusion images. ResultsGated SPECT images improved image clarity and contrast of tumour 201Tl uptakes compared with ungated images, regardless of the decreased count density due to the use of gated images. The lesion-to-normal (L/N) lung count ratios and ROI size in 18 well-circumscribed 201Tl-avid tumours were significantly higher and smaller on gated images (both P<0.0001). Gated images showed positive 201Tl uptakes in two small peripheral tumours, although negative on ungated images, and demarcated 201Tl-avid tumours from adjacent 201Tl-avid lymph node or surrounding focal 201Tl uptakes caused by other pathology, although these were not clearly demarcated on ungated images. On fusion images, gated images yielded a significantly better SPECT–CT matching compared with ungated images (P<0.0001). Fusion images accurately localized 201Tl uptakes of tumour/lymph node and other focal pathological/physiological conditions. Attenuation-corrected gated SPECT images further facilitated the detection of 201Tl uptake in small or deeply located lesions, with significantly increased L/N ratios. ConclusionGated SPECT images facilitate the detection of tumour 201Tl uptake and provide reliable SPECT–CT fusion images, which contribute to accurate interpretation and attenuation correction of 201Tl SPECT images.
Journal of Magnetic Resonance Imaging | 2004
Nobuhiko Ogasawara; Kazuyoshi Suga; Yasuhiko Kawakami; Tomio Yamashita; Mohammed Zaki; Naofumi Matsunaga
To define regional function impairment in airway obstruction (AO) and pulmonary embolic (PE) dogs with a combination study of noncontrast electrocardiogram (ECG)‐gated perfusion and gadolinium diethylenetriaminepentaacetic acid (Gd‐DTPA) aerosol magnetic resonance (MR) images.
European Journal of Nuclear Medicine and Molecular Imaging | 2004
Kazuyoshi Suga; Yasuhiko Kawakami; Mohammed Zaki; Tomio Yamashita; Kensaku Shimizu; Naofumi Matsunaga
European Journal of Nuclear Medicine and Molecular Imaging | 2004
Kazuyoshi Suga; Kawakami Yasuhiko; Mohammed Zaki; Tomio Yamashita; Aska Seto; Tsuneo Matsumoto; Naofumi Matsunaga
Nuclear Medicine Communications | 2006
Kazuyoshi Suga; Yasuhiko Kawakami; Tomio Yamashita; Mohammed Zaki; Naofumi Matsunaga
Nuclear Medicine Communications | 2005
Kazuyoshi Suga; Kawakami Yasuhiko; Hideyuki Iwanaga; Norio Hayashi; Tomio Yamashita; Naofumi Matsunaga
Annals of Nuclear Medicine | 2007
Yasuhiko Kawakami; Kazuyoshi Suga; Mohammed Zaki; Hideyuki Iwanaga; Tomio Yamashita; Noriko Hayashi; Naofumi Matsunaga