Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Tomokazu Ishida is active.

Publication


Featured researches published by Tomokazu Ishida.


Medical Imaging 2004: Physics of Medical Imaging | 2004

Evaluation of dose efficiency index compared to receiver operating characteristics for assessing CT low-contrast performance

Tomokazu Ishida; Shinsuke Tsukagoshi; Kazuyuki Kondo; Kazuhisa Kainuma; Miwa Okumura; Tsukasa Sasaki

The dose efficiency index (DEI) is a dose independent measure that quantifies the low-contrast performance of CT scanners. The purpose of this paper is to compare the results of DEI analysis with those of ROC analysis. A custom-made phantom consisting of diluted contrast targets of various sizes and densities was scanned at 80 & 120 kV on a multislice CT scanner (Hispeed Advantage RP, GE). Eight radiographers reviewed the images and identified discernable targets. The likelihood of detection was measured as a function of the target size and scan conditions. The results of the DEI & ROC analyses showed that the low-contrast resolution was higher at 80kV than at 120kV. The p-value obtained by the paired-t test was 0.000 for both analyses, indicating that the difference was significant. Under the conditions used in this study, the DEI analysis was found to be an effective alternative to ROC analysis for characterizing the low-contrast performance of CT scanners. The evaluation time was about 1/6 compared with ROC analysis. It is much simpler to calculate than ROC and is useful in comparing scanners from different manufacturers or as part of ongoing quality assurance.


International Journal of Intelligent Computing in Medical Sciences & Image Processing | 2009

Improvement of Low-dose MDCT Images by Applying a Novel Adaptive Median Filter with Local Averaging

Jiehang Deng; Koichiro Hiratsuka; Tomokazu Ishida; Haruhiko Shirai; Jousuke Kuroiwa; Tomohiro Odaka; Hisakazu Ogura

In order to reduce the quantum noise level without the expense of feature preservation of small tumors, a novel 3D adaptive median filter with local averaging is developed according to the size of tumors and the distribution of voxel value in a local region. In this paper, two new methods based on entropy of correlation and mutual information of correlation are also proposed to evaluate the validity and efficiency of the proposed filter quantitatively. The proposed filter is applied to processing low-dose abdominal datasets, and experimental results show that the filtering technique is able to reduce the level of the quantum noise and preserve the features of the edge region and the shape of the tumors for low-dose abdominal 3D MDCT images.


computer science and software engineering | 2008

Analysis of 3D Linear and Non-linear Filtering Effects Based on 3D MDCT Medical Images

Jiehang Deng; Yoshihito Susuki; Koichiro Hiratsuka; Tomokazu Ishida; Toshihide Itoh; Jian Zhou; Haruhiko Shirai; Jousuke Kuroiwa; Tomohiro Odaka; Hisakazu Ogura

The risk of X-ray exposure will increase when applying the 3D-CT methods such as MDCT. To decrease this risk it is better to lower the dose-level of X-ray, but it reduces the resolution of obtained image and causes negative effect on imaging diagnosis. We think that 3D-filtering methods will recover the reduction. In order to obtain a better filtered result, 3D linear and non-linear filters are designed and applied to 80%, 60%, 40% and 20%-dose simulated low dose clinical MDCT images of abdomen with a tumor. Direct observation and 3D voxel value profile is extracted to evaluate the filtered results. Experimental results show both the filtering and the evaluating method perform well.


Archive | 2010

低線量 3D-CT 画像における画質改善

紘一郎 平塚; 久和 小倉; 智一 石田; Kouichirou Hiratsuka; Hisakazu Ogura; Tomokazu Ishida


電子情報通信学会技術研究報告. MI, 医用画像 | 2009

An adaptive 3D filter to improve the noise level of Low-Dose 3D MDCT(International Forum on Medical Imaging in Asia 2009 (IFMIA 2009))

Yoshihito Susuki; Jiehang Deng; Koichiro Hiratsuka; Hisakazu Ogura; Haruhiko Shirai; Jousuke Kuroiwa; Tomohiro Odaka; Toshihide Itoh; Tomokazu Ishida; Kazutaka Yamamoto


Nihon Hōshasen Gijutsu Gakkai zasshi | 2007

[Usefulness of low- and medium-energy collimators in 123I-MIBG myocardial scintigraphy].

Ryoko Sakashita; Katsuya Sugimoto; Yuko Fukuya; Hiroshi Fujibuchi; Tomokazu Ishida; Kyoji Higashimura; Tatsuro Tsuchida


Nihon Hōshasen Gijutsu Gakkai zasshi | 2003

[Usefulness of low tube operating potential (TOP) for improved detection of minimally contrast-enhanced nodules CT].

Tomokazu Ishida; Higashimura K; Itou H


Japanese Journal of Radiological Technology | 2003

Report on the 14th European Congress of Radiology(ECR)

Tomokazu Ishida; Kyoji Higashimura; H. Itou


Japanese Journal of Radiological Technology | 1998

Ability to recognize the CT image with different effective energy.

Tomokazu Ishida; Hiroshi Hujibuchi; Kyoji Higashimura; Hiroyuki Komuro


Japanese Journal of Radiological Technology | 1997

Development of a Registration Technique with Nonlinear Geometric Warping in DSA Images

Yasuhiro Nishimoto; Masato Tanaka; Tetsuya Fukushima; Hiroyuki Sashie; Tomokazu Ishida; Hiroyuki Komuro; Nobuhsige Hayashi; Norihiro Sadatou; Yasushi Ishii; Tamami Makino; Hisakazu Ogura

Collaboration


Dive into the Tomokazu Ishida's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge