Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Toralf Neuling is active.

Publication


Featured researches published by Toralf Neuling.


Frontiers in Human Neuroscience | 2013

Transcranial alternating current stimulation: a review of the underlying mechanisms and modulation of cognitive processes

Christoph Herrmann; Stefan Rach; Toralf Neuling; Daniel Strüber

Brain oscillations of different frequencies have been associated with a variety of cognitive functions. Convincing evidence supporting those associations has been provided by studies using intracranial stimulation, pharmacological interventions and lesion studies. The emergence of novel non-invasive brain stimulation techniques like repetitive transcranial magnetic stimulation (rTMS) and transcranial alternating current stimulation (tACS) now allows to modulate brain oscillations directly. Particularly, tACS offers the unique opportunity to causally link brain oscillations of a specific frequency range to cognitive processes, because it uses sinusoidal currents that are bound to one frequency only. Using tACS allows to modulate brain oscillations and in turn to influence cognitive processes, thereby demonstrating the causal link between the two. Here, we review findings about the physiological mechanism of tACS and studies that have used tACS to modulate basic motor and sensory processes as well as higher cognitive processes like memory, ambiguous perception, and decision making.


Frontiers in Human Neuroscience | 2013

Orchestrating neuronal networks: sustained after-effects of transcranial alternating current stimulation depend upon brain states.

Toralf Neuling; Stefan Rach; Christoph Herrmann

The interest in transcranial alternating current stimulation (tACS) has significantly increased in the past decade. It has potential to modulate brain oscillations in a frequency specific manner, offering the possibility to demonstrate a causal nature of oscillation behavior relationships. TACS is a strong candidate as a tool for clinical applications, however, to fulfill this potential, certain parameters have yet to be evaluated. First, little is known about long-lasting after-effects of tACS with respect to the modulations of rhythmic brain activity. Second, the power of endogenous brain oscillations might play a crucial role in the efficacy of tACS. We hypothesize that the after-effects of tACS depend on the endogenous power of oscillations. To this end, we modulated the power of endogenous occipital alpha oscillations via tACS. In two experiments, participants either had their eyes open or closed to keep endogenous alpha power either low or high while they were stimulated for 20 min with their individual alpha frequency (IAF) and simultaneously performing a vigilance task. After-effects on IAF power were evaluated over a course of 30 min with a pre stimulation period serving as baseline. After-effects were strongly dependent on IAF power. Enhanced IAF power was observed for at least 30 min after tACS under conditions of low endogenous IAF power, whereas, IAF power could not be further enhanced by tACS under conditions of high IAF power. The current study demonstrates, for the first time, a long lasting effect after tACS on endogenous EEG power in the range of the stimulation frequency. Additionally, we present conclusive evidence that the power of the endogenous oscillations has a critical impact on tACS efficacy. Long lasting after-effects foster the role of tACS as a tool for non-invasive brain stimulation and demonstrate the potential for therapeutic application to reestablish the balance of altered brain oscillations.


NeuroImage | 2012

Good vibrations: oscillatory phase shapes perception.

Toralf Neuling; Stefan Rach; Sven Wagner; Carsten H. Wolters; Christoph Herrmann

In the current study, we provide compelling evidence to answer the long-standing question whether perception is continuous or periodic. Spontaneous brain oscillations are assumed to be the underlying mechanism of periodic perception. Depending on the phase angle of the oscillations, an identical stimulus results in different perceptual outcomes. Past results, however, can only account for a correlation of perception with the phase of the ongoing brain oscillations. Therefore, it is desirable to demonstrate a causal relation between phase and perception. One way to address this question is to entrain spontaneous brain oscillations by applying an external oscillation and then demonstrate behavioral consequences of this oscillation. We conducted an auditory detection experiment with humans, recorded the electroencephalogram (EEG) concurrently and simultaneously applied oscillating transcranial direct current stimulation at 10Hz (α-tDCS). Our approach revealed that detection thresholds were dependent on the phase of the oscillation that was entrained by α-tDCS. This behavioral effect was accompanied by an electrophysiological effect: α-power was enhanced after α-tDCS as compared to a pre-stimulation period. By showing a causal relation between phase and perception, our results extend findings of previous studies that were only able to demonstrate a correlation. We found that manipulation of the phase resulted in different detection thresholds, which supports the notion that perception can be periodically modulated by oscillatory processes. This demonstrates that tDCS can serve as a tool in neuroscience to extend the knowledge of the functional significance of brain oscillations.


Frontiers in Psychiatry | 2012

Finite-Element Model Predicts Current Density Distribution for Clinical Applications of tDCS and tACS

Toralf Neuling; Sven Wagner; Carsten H. Wolters; Tino Zaehle; Christoph Herrmann

Transcranial direct current stimulation (tDCS) has been applied in numerous scientific studies over the past decade. However, the possibility to apply tDCS in therapy of neuropsychiatric disorders is still debated. While transcranial magnetic stimulation (TMS) has been approved for treatment of major depression in the United States by the Food and Drug Administration (FDA), tDCS is not as widely accepted. One of the criticisms against tDCS is the lack of spatial specificity. Focality is limited by the electrode size (35 cm2 are commonly used) and the bipolar arrangement. However, a current flow through the head directly from anode to cathode is an outdated view. Finite-element (FE) models have recently been used to predict the exact current flow during tDCS. These simulations have demonstrated that the current flow depends on tissue shape and conductivity. To face the challenge to predict the location, magnitude, and direction of the current flow induced by tDCS and transcranial alternating current stimulation (tACS), we used a refined realistic FE modeling approach. With respect to the literature on clinical tDCS and tACS, we analyzed two common setups for the location of the stimulation electrodes which target the frontal lobe and the occipital lobe, respectively. We compared lateral and medial electrode configuration with regard to their usability. We were able to demonstrate that the lateral configurations yielded more focused stimulation areas as well as higher current intensities in the target areas. The high resolution of our simulation allows one to combine the modeled current flow with the knowledge of neuronal orientation to predict the consequences of tDCS and tACS. Our results not only offer a basis for a deeper understanding of the stimulation sites currently in use for clinical applications but also offer a better interpretation of observed effects.


Journal of Neural Engineering | 2014

Investigation of tDCS volume conduction effects in a highly realistic head model.

Sven Wagner; S.M. Rampersad; Umit Aydin; Johannes Vorwerk; Thom F. Oostendorp; Toralf Neuling; Christoph Herrmann; Dick F. Stegeman; Carsten H. Wolters

OBJECTIVE We investigate volume conduction effects in transcranial direct current stimulation (tDCS) and present a guideline for efficient and yet accurate volume conductor modeling in tDCS using our newly-developed finite element (FE) approach. APPROACH We developed a new, accurate and fast isoparametric FE approach for high-resolution geometry-adapted hexahedral meshes and tissue anisotropy. To attain a deeper insight into tDCS, we performed computer simulations, starting with a homogenized three-compartment head model and extending this step by step to a six-compartment anisotropic model. MAIN RESULTS We are able to demonstrate important tDCS effects. First, we find channeling effects of the skin, the skull spongiosa and the cerebrospinal fluid compartments. Second, current vectors tend to be oriented towards the closest higher conducting region. Third, anisotropic WM conductivity causes current flow in directions more parallel to the WM fiber tracts. Fourth, the highest cortical current magnitudes are not only found close to the stimulation sites. Fifth, the median brain current density decreases with increasing distance from the electrodes. SIGNIFICANCE Our results allow us to formulate a guideline for volume conductor modeling in tDCS. We recommend to accurately model the major tissues between the stimulating electrodes and the target areas, while for efficient yet accurate modeling, an exact representation of other tissues is less important. Because for the low-frequency regime in electrophysiology the quasi-static approach is justified, our results should also be valid for at least low-frequency (e.g., below 100 Hz) transcranial alternating current stimulation.


NeuroImage | 2015

Friends, not foes: Magnetoencephalography as a tool to uncover brain dynamics during transcranial alternating current stimulation

Toralf Neuling; Philipp Ruhnau; Marco Fuscà; Gianpaolo Demarchi; Christoph Herrmann

Brain oscillations are supposedly crucial for normal cognitive functioning and alterations are associated with cognitive dysfunctions. To demonstrate their causal role on behavior, entrainment approaches in particular aim at driving endogenous oscillations via rhythmic stimulation. Within this context, transcranial electrical stimulation, especially transcranial alternating current stimulation (tACS), has received renewed attention. This is likely due to the possibility of defining oscillatory stimulation properties precisely. Also, measurements comparing pre-tACS with post-tACS electroencephalography (EEG) have shown impressive modulations. However, the period during tACS has remained a blackbox until now, due to the enormous stimulation artifact. By means of application of beamforming to magnetoencephalography (MEG) data, we successfully recovered modulations of the amplitude of brain oscillations during weak and strong tACS. Additionally, we demonstrate that also evoked responses to visual and auditory stimuli can be recovered during tACS. The main contribution of the present study is to provide critical evidence that during ongoing tACS, subtle modulations of oscillatory brain activity can be reconstructed even at the stimulation frequency. Future tACS experiments will be able to deliver direct physiological insights in order to further the understanding of the contribution of brain oscillations to cognition and behavior.


Scientific Reports | 2016

Eyes wide shut: Transcranial alternating current stimulation drives alpha rhythm in a state dependent manner

Philipp Ruhnau; Toralf Neuling; Marco Fuscà; Christoph Herrmann; Gianpaolo Demarchi

Transcranial alternating current stimulation (tACS) is used to modulate brain oscillations to measure changes in cognitive function. It is only since recently that brain activity in human subjects during tACS can be investigated. The present study aims to investigate the phase relationship between the external tACS signal and concurrent brain activity. Subjects were stimulated with tACS at individual alpha frequency during eyes open and eyes closed resting states. Electrodes were placed at Cz and Oz, which should affect parieto-occipital areas most strongly. Source space magnetoencephalography (MEG) data were used to estimate phase coherence between tACS and brain activity. Phase coherence was significantly increased in areas in the occipital pole in eyes open resting state only. The lag between tACS and brain responses showed considerable inter-individual variability. In conclusion, tACS at individual alpha frequency entrains brain activity in visual cortices. Interestingly, this effect is state dependent and is clearly observed with eyes open but only to a lesser extent with eyes closed.


Frontiers in Cellular Neuroscience | 2015

On the possible role of stimulation duration for after-effects of transcranial alternating current stimulation.

Daniel Strüber; Stefan Rach; Toralf Neuling; Christoph Herrmann

Transcranial alternating current stimulation is a novel method that allows application of sinusoidal currents to modulate brain oscillations and cognitive processes. Studies in humans have demonstrated transcranial alternating current stimulation (tACS) after-effects following stimulation durations in the range of minutes. However, such after-effects are absent in animal studies using much shorter stimulation protocols in the range of seconds. Thus, stimulation duration might be a critical parameter for after-effects to occur. To test this hypothesis, we repeated a recent human tACS experiment with a short duration. We applied alpha tACS intermittently for 1 s duration while keeping other parameters identical. The results demonstrate that this very short intermittent protocol did not produce after-effects on amplitude or phase of the electroencephalogram. Since synaptic plasticity has been suggested as a possible mechanism for after-effects, our results indicate that a stimulation duration of 1 s is too short to induce synaptic plasticity. Future studies in animals are required that use extended stimulation durations to reveal the neuronal underpinnings. A better understanding of the mechanisms of tACS after-effects is crucial for potential clinical applications.


NeuroImage | 2017

Faith and oscillations recovered: On analyzing EEG/MEG signals during tACS

Toralf Neuling; Philipp Ruhnau; Christoph Herrmann; Gianpaolo Demarchi

ABSTRACT Despite recent success in analyzing brain oscillations recorded during transcranial alternating current stimulation (tACS), the field still requires further research to establish standards in artifact removal methods. This includes taking a step back from the removal of the tACS artifact and thoroughly characterizing the to‐be‐removed artifact. A recent study by Noury et al. (2016) contributed importantly to this endeavour by showing the existence of nonlinear artefacts in the tACS signal as seen by MEG and EEG. Unfortunately however this paper conveys the message that current artifact removal attempts have failed altogether and that—based on these available tools—brain oscillations recorded during tACS cannot be analyzed using MEG and EEG. Here we want to balance this overly pessimistic conclusion: In‐depth reanalyses of our own data and phantom‐head measurements indicate that nonlinearities can occur, but only when technical limits of the stimulator are reached. As such they are part of the “real” stimulation and not a specific MEG analysis problem. Future tACS studies should consider these technical limits to avoid any nonlinear modulations of the tACS artifact. We conclude that even with current approaches, brain oscillations recorded during tACS can be meaningfully studied in many practical cases.


Frontiers in Human Neuroscience | 2016

Flicker-Driven Responses in Visual Cortex Change during Matched-Frequency Transcranial Alternating Current Stimulation

Philipp Ruhnau; Christian Keitel; Chrysa Lithari; Toralf Neuling

We tested a novel combination of two neuro-stimulation techniques, transcranial alternating current stimulation (tACS) and frequency tagging, that promises powerful paradigms to study the causal role of rhythmic brain activity in perception and cognition. Participants viewed a stimulus flickering at 7 or 11 Hz that elicited periodic brain activity, termed steady-state responses (SSRs), at the same temporal frequency and its higher order harmonics. Further, they received simultaneous tACS at 7 or 11 Hz that either matched or differed from the flicker frequency. Sham tACS served as a control condition. Recent advances in reconstructing cortical sources of oscillatory activity allowed us to measure SSRs during concurrent tACS, which is known to impose strong artifacts in magnetoencephalographic (MEG) recordings. For the first time, we were thus able to demonstrate immediate effects of tACS on SSR-indexed early visual processing. Our data suggest that tACS effects are largely frequency-specific and reveal a characteristic pattern of differential influences on the harmonic constituents of SSRs.

Collaboration


Dive into the Toralf Neuling's collaboration.

Top Co-Authors

Avatar

Christoph Herrmann

Braunschweig University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sven Wagner

University of Münster

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge