Toshimitsu Watabiki
Kansai Medical University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Toshimitsu Watabiki.
Journal of Forensic Sciences | 1996
Atsushi Akane; Sumitaka Yoshimura; Manabu Yoshida; Yutaka Okii; Toshimitsu Watabiki; Kazuo Matsubara; Kojiro Kimura
Using primers designed by Lee and Chang, 200 base-pair (bp) fragment of ABO locus was amplified by PCR, which spans the site of the single nucleotide deletion associated with O allele. O allele could be identified by Kpn I digestion of the PCR product as reported. A and B alleles were also distinguishable by Mae II digestion of the product. Thus restriction digestion by Kpn I and Mae II could genotype ABO blood group following the single amplification. The nucleotide substitution in the 200-bp product between A and B alleles was also found in O allele, resulting in 2 different suballeles OA and OG. The single-strand conformational polymorphism of the PCR product was also investigated for ABO genotyping following the single amplification.
Forensic Science International | 1991
Manabu Yoshida; Junko Adachi; Toshimitsu Watabiki; Yoshitsugu Tatsuno; Noriaki Ishida
Correlation among age, concentrations of carboxyhemoglobin and hydrogen cyanide, oxygen density and hemolysis were studied in 120 house fire victims. Victims aged over 60 years comprised approximately 50% of the pooled subjects. Blood samples were mainly collected from the left ventricle, but sometimes from both the right and left ventricles. The concentration of carboxyhemoglobin ranged from 1-95%, of which 71 persons (59.7%) died with carboxyhemoglobin concentrations below 60%. Carboxyhemoglobin concentrations below 10% were found in 9 persons (7.5%). Most of these cases involved the elderly persons. In this paper, we report on the death of elderly victims as a result of low carboxyhemoglobin concentrations. A significant correlation of blood carboxyhemoglobin concentrations existed between the right and left ventricles. The concentration of carboxyhemoglobin in the left ventricle was significantly higher than that in the right. Two out of 31 victims whose hydrogen cyanide concentrations were determined, succumbed to hydrogen cyanide poisoning, having a high concentration of hydrogen cyanide and a low concentration of carboxyhemoglobin. On analysis, oxygen density was found to be low in 13 persons. A negative correlation was shown between carboxyhemoglobin concentration and hemolysis. Inasmuch as hemolysis may indicate the extent of heat dissociation, hemolysis should provide an index of carbon monoxide dissociation from carboxyhemoglobin. In the present study of victims, possible causes of death i.e., carbon monoxide gas poisoning, hydrogen cyanide poisoning, oxygen deprivation, burning, shock due to burns and others were estimated. The survival time for elderly victims was considered to be short.
International Journal of Legal Medicine | 1995
Sumitaka Yoshimura; Manabu Yoshida; Yutaka Okii; Takuma Tokiyasu; Toshimitsu Watabiki; Atsushi Akane
The plankton test (generally, diatom test) is one of the methods available to diagnose the cause of death of submerged bodies. The solubilization method using tissue solubilizer Soluene-350 was used in this study to detect not only diatoms but also green algae, based on the fact that the solubilizer does not digest the cell walls of green algae which are made from cellulose. Detection of green algae from organs of submerged cadavers is very informative to determine drowning in fresh water, and also in cases where only few diatoms are detected in the organs.[/p]
Journal of Chromatography A | 1993
Manabu Yoshida; Toshimitsu Watabiki; Takuma Tokiyasu; Noriaki Ishida
Abstract Thermospray liquid chromatography-mass spectrometry can be used for identifying and determining both paraquat (C 12 H 14 N 2+ 2 ) and diquat (C 12 H 12 N 2+ 2 ). Reversed-phase liquid chromatography was performed using a 15-cm Shim-pack CLCODS column, with methanol-water (80–20) + 0.1 M ammonium acetate (adjusted to pH 5 with trifluoroacetic acid) as buffers, at a flow-rate of 1.0 ml/min. The mass spectral sensitivity was best when the temperatures of the vaporizer, block and tip heater of the ion source block were set at paraquat and diquat, respectively. Detection limits by selected ion monitoring were of the order of 20 ng ( S / N = 3.5). The mass spectra are influenced by temperature and therefore, precise temperature contorl is essential.
Journal of Human Genetics | 1997
Atsushi Akane; Tetsuya Kobayashi; Zhi-Xiang Li; Sumitaka Yoshimura; Yutaka Okii; Manabu Yoshida; Takuma Tokiyasu; Toshimitsu Watabiki
SummaryPCR-based genotyping of MNSs blood group system was investigated in combination with restriction fragment length polymorphism (RFLP), single-strand conformation polymorphism (SSCP) and allele-specific PCR amplification (ASPA) techniques. M and N alleles are based on three nucleotide substitutions in exon 2 and one base change (G or T) in an intron of glycophorin A locus. The latter single base change was also found among M alleles analyzed in this study, so that M allele appeared to be subdivided into MG and MT. All three alleles, MG, MT and N were identified clearly by RFLP or SSCP analysis following a single amplification. S and s alleles are based on one nucleotide substitution in exon 3 of glycophorin B gene. Genotyping of Ss blood group system was also explored by PCR-SSCP or ASPA analysis, and problems in the methods were discussed.
Alcoholism: Clinical and Experimental Research | 1999
Toshimitsu Watabiki; Takuma Tokiyasu; Manabu Yoshida; Yutaka Okii; Sumitaka Yoshimura; Atsushi Akane
The hepatic lobular localization of class I alcohol dehydrogenase (ADH) and aldehyde dehydrogenase (ALDH) 2 activities was examined histochemically using livers of hamsters with high ethanol preferences. The activity of class I ADH detected by the nitro blue tetrazolium method using 5 mM ethanol as a substrate was extremely high and was almost homogeneously distributed throughout the lobule. The ALDH 2 activity (substrate, 8 μM acetaldehyde) was localized to the centrilobular zone, whereas low Km ALDH (ALDH 1 + ALDH 2) activity (substrate, 50 μM acetaldehyde) showed a gradient distribution in the lobule with high centrilobular to moderate periportal activity, suggesting that the ALDH 1 activity was distributed throughout the lobule.
Journal of Chromatography B: Biomedical Sciences and Applications | 1998
Manabu Yoshida; Atsushi Akane; Yutaka Okii; Sumitaka Yoshimura; Takuma Tokiyasu; Toshimitsu Watabiki
Rapid assay of dihydrocodeine (DHC) by thermospray mass spectrometry is explored. Liquid-liquid extractions of blood, urine and gastric contents were injected into a thermospray mass spectrometer, to which there was no column connected, and DHC was assayed by the flow injection method. The mass spectra of DHC under thermospray ionization and filament-on ionization modes consist of the MH+ ion of mlz 302 alone, which was clearly detected in the samples. Although DHC should be quantitated by gas chromatography-mass spectrometry, this method is applicable for rapid identification of DHC in biological materials.
Legal Medicine | 2003
Toshimitsu Watabiki; Atsushi Akane; Yutaka Okii; Sumitaka Yoshimura; Takuma Tokiyasu; Manabu Yoshida
Phenotyping of ABO and Rh blood groups was performed by the absorption-elution technique using cerebral dura maters. For the ABO system, the cerebral dura maters extracted from nine autopsied cadavers including two burnt bodies, two putrefied corpses, and one half-mummified and one skeletal structure were tested with commercially available Wako antisera (animal polyclonal antibodies). At the same time, blood, fingernails or bones were sampled. In all the cases, the phenotypes could be typed correctly and more clearly with the use of 2 x 2 x 0.3 mm dura maters (0.6 mm thick dura maters were sliced to 0.3 mm thickness) than the phenotyping using 2 x 2 mm fingernails or 2 x 2 x 1 mm bones. For the Rh system, the cerebral dura maters extracted from eight autopsied cadavers within 2 days after death including two burnt bodies were tested with commercially available Ortho Bioclone anti-C, anti-c, anti-E and anti-e sera (human monoclonal antibodies), and Ortho anti-D serum (human polyclonal antibody). The eluate of anti-D antibody was needed to perform the indirect anti-globulin test (Ortho Coombs serum). At the same time, blood was sampled. In all the cases, the Rh blood groups of cerebral dura maters were in agreement with those of blood.
Analytical Chemistry | 2004
Manabu Yoshida; Atsushi Akane; Mayumi Nishikawa; Toshimitsu Watabiki; Hitoshi Tsuchihashi
Alcoholism: Clinical and Experimental Research | 2000
Toshimitsu Watabiki; Yutaka Okii; Takuma Tokiyasu; Sumitaka Yoshimura; Manabu Yoshida; Atsushi Akane; N. Shikata; A. Tsubura