American Journal of Roentgenology | 2014

Effect of Patient Centering on Patient Dose and Image Noise in Chest CT

Touko Kaasalainen; Kirsi Palmu; Vappu Reijonen; Mika Kortesniemi

OBJECTIVE The objective of our study was to evaluate the effect of vertical centering on dose and image noise in chest MDCT of different-sized patients using anthropomorphic phantoms and retrospectively studying examinations of clinical patients. MATERIALS AND METHODS Three different anthropomorphic phantoms were scanned using different vertical centering (offset ± 6 cm) and were assessed with radiation dose-monitoring software. The effect of vertical positioning on the radiation dose was studied using the volume CT dose index, dose-length product, and size-specific dose estimates for different-sized phantoms. Image noise was determined from CT number histograms. Vertical positioning for chest CT examinations of 112 patients ranging from neonates to adults were retrospectively assessed. RESULTS Radiation doses were highest when using the posteroanterior scout image for automatic exposure control (AEC) and when phantoms were set in the lowest table position, and radiation doses were lowest when phantoms were set in the uppermost table position. For the adult phantom, relative doses increased by 38% in the lowest table position and decreased by 23% in the highest table position. Similarly, doses for pediatric 5-year-old and newborn phantoms were 21% and 12% higher in the lowest table position and 12% and 8% lower in the highest table position, respectively. The effect decreased when a lateral scout image was used for AEC. The relative noise was lowest when the phantoms were properly centered and increased with vertical offset. In clinical patients, we observed offset with a median value varying from 25 to 35 mm below the isocenter. CONCLUSION Regardless of patient size, most patients in this study were positioned too low, which negatively affected both patient dose and image noise. Miscentering was more pronounced in smaller pediatric patients.


Physica Medica | 2015

Dental cone beam CT: A review

Timo Kiljunen; Touko Kaasalainen; Anni Suomalainen; Mika Kortesniemi

For the maxillofacial region, there are various indications that cannot be interpreted from 2D images and will benefit from multiplanar viewing. Dental cone beam CT (CBCT) utilises a cone- or pyramid-shaped X-ray beam using mostly flat-panel detectors for 3D image reconstruction with high spatial resolution. The vast increase in availability and amount of these CBCT devices offers many clinical benefits, and their ongoing development has potential to bring various new clinical applications for medical imaging. Additionally, there is also a need for high quality research and education. European guidelines promote the use of a medical physics expert for advice on radiation protection, patient dose optimisation, and equipment testing. In this review article, we perform a comparison of technical equipment based on manufacturer data, including scanner specific X-ray spectra, and describe issues concerning CBCT image reconstruction and image quality, and also address radiation dose issues, dosimetry, and optimisation. We also discuss clinical needs and what type of education users should have in order to operate CBCT systems safely. We will also take a look into the future and discuss the issues that still need to be solved.


American Journal of Roentgenology | 2015

Lens Dose in Routine Head CT: Comparison of Different Optimization Methods With Anthropomorphic Phantoms

Ulla Nikupaavo; Touko Kaasalainen; Vappu Reijonen; Sanna-Mari Ahonen; Mika Kortesniemi

OBJECTIVE The purpose of this study was to study different optimization methods for reducing eye lens dose in head CT. MATERIALS AND METHODS Two anthropomorphic phantoms were scanned with a routine head CT protocol for evaluation of the brain that included bismuth shielding, gantry tilting, organ-based tube current modulation, or combinations of these techniques. Highsensitivity metal oxide semiconductor field effect transistor dosimeters were used to measure local equivalent doses in the head region. The relative changes in image noise and contrast were determined by ROI analysis. RESULTS The mean absorbed lens doses varied from 4.9 to 19.7 mGy and from 10.8 to 16.9 mGy in the two phantoms. The most efficient method for reducing lens dose was gantry tilting, which left the lenses outside the primary radiation beam, resulting in an approximately 75% decrease in lens dose. Image noise decreased, especially in the anterior part of the brain. The use of organ-based tube current modulation resulted in an approximately 30% decrease in lens dose. However, image noise increased as much as 30% in the posterior and central parts of the brain. With bismuth shields, it was possible to reduce lens dose as much as 25%. CONCLUSION Our results indicate that gantry tilt, when possible, is an effective method for reducing exposure of the eye lenses in CT of the brain without compromising image quality. Measurements in two different phantoms showed how patient geometry affects the optimization. When lenses can only partially be cropped outside the primary beam, organ-based tube current modulation or bismuth shields can be useful in lens dose reduction.


Pediatric Radiology | 2015

Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

Touko Kaasalainen; Kirsi Palmu; Anniina Lampinen; Vappu Reijonen; Junnu Leikola; Riku Kivisaari; Mika Kortesniemi

BackgroundMedical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis.ObjectiveTo evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging.Materials and methodsWe scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues.ResultsMean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level.ConclusionCraniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality.


Radiation Protection Dosimetry | 2015

Fetal radiation dose in computed tomography

Anna Kelaranta; Touko Kaasalainen; Raija Seuri; Paula Toroi; Mika Kortesniemi

The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept the mean Df fairly constant through all pregnancy stages in trauma (4.4-4.9 mGy) and abdomino-pelvic (2.1-2.4 mGy) protocols. In pulmonary angiography protocol, the mean Df increased exponentially as the distance from the end of the scan range decreased (0.01-0.09 mGy). For trauma protocol, the relative mean Df as a function of gestational age were in the range 0.80-0.97 compared with the mean CTDI vol. For abdomino-pelvic protocol, the relative mean Df was 0.57-0.79 and for pulmonary angiography protocol, 0.01-0.05 compared with the mean CTDI vol, respectively. In conclusion, if the fetus is in the primary beam, the CTDI vol can be used as an upper estimate of the fetal dose. If the fetus is not in the primary beam, the fetal dose can be estimated by considering also the distance of the fetus from the scan range.


EJNMMI Physics | 2017

Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR

Eero Hippeläinen; Teemu Mäkelä; Touko Kaasalainen; Erna Kaleva

BackgroundDevelopments in single photon emission tomography instrumentation and reconstruction methods present a potential for decreasing acquisition times. One of such recent options for myocardial perfusion imaging (MPI) is IQ-SPECT. This study was motivated by the inconsistency in the reported ejection fraction (EF) and left ventricular (LV) volume results between IQ-SPECT and more conventional low-energy high-resolution (LEHR) collimation protocols. IQ-SPECT and LEHR quantitative results were compared while the equivalent number of iterations (EI) was varied. The end-diastolic (EDV) and end-systolic volumes (ESV) and the derived EF values were investigated.A dynamic heart phantom was used to produce repeatable ESVs, EDVs and EFs. Phantom performance was verified by comparing the set EF values to those measured from a gated multi-slice X-ray computed tomography (CT) scan (EFTrue). The phantom with an EF setting of 45, 55, 65 and 70% was imaged with both IQ-SPECT and LEHR protocols. The data were reconstructed with different EI, and two commonly used clinical myocardium delineation software were used to evaluate the LV volumes.ResultsThe CT verification showed that the phantom EF settings were repeatable and accurate with the EFTrue being within 1% point from the manufacture’s nominal value. Depending on EI both MPI protocols can be made to produce correct EF estimates, but IQ-SPECT protocol produced on average 41 and 42% smaller EDV and ESV when compared to the phantom’s volumes, while LEHR protocol underestimated volumes by 24 and 21%, respectively. The volume results were largely similar between the delineation methods used.ConclusionsThe reconstruction parameters can greatly affect the volume estimates obtained from perfusion studies. IQ-SPECT produces systematically smaller LV volumes than the conventional LEHR MPI protocol. The volume estimates are also software dependent.


Acta Radiologica | 2016

Cardiac MRI in patients with cardiac pacemakers: practical methods for reducing susceptibility artifacts and optimizing image quality

Touko Kaasalainen; Sari Kivistö; Miia Holmström; Juha E. Peltonen; Sami Pakarinen; Helena Hänninen; Outi Sipilä

Background Magnetic resonance imaging (MRI) of pacemaker patients has become available despite of previous contraindications. However, pacing systems containing ferromagnetic material may hamper the diagnostic quality of cardiac MR (CMR) images. Purpose To study methods for reducing susceptibility-based artifacts in CMR examinations of pacemaker patients. Material and Methods Altogether 16 patients were scanned with 1.5T MRI scanner using cine balanced steady-state free-precession (bSSFP) and spoiled gradient echo (SPGR) sequences. The use of frequency-scout was also evaluated. For myocardial late gadolinium-enhanced (LGE) imaging, SPGR or bSSFP readout inversion-recovery prepared gradient echo sequences were used with and without phase-sensitive inversion-recovery (PSIR). Two radiologists subjectively compared the image quality (IQ) and the ranges of susceptibility artifacts were evaluated objectively. Results The IQ proved adequate for diagnosing each patient, although in a few patients with a left-side implanted generator, artifacts hampered IQ in the anterior and anteroseptal segments of the myocardium in bSSFP cine and LGE sequences. In bSSFP cine, the use of frequency-scout could often transfer the banding artifacts away from the left ventricular myocardium. In LGE imaging, the artifacts were more pronounced in IR-bSSFP and PSIR than in IR-SPGR sequences. The ranges of generator-based artifacts were greater in bSSFP (10–12 cm) than in SPGR (6 cm) sequences due to banding artifacts. Conclusion The artifacts caused by pacemakers typically did not compromise the diagnostic IQ. The use of frequency-scout prior to bSSFP cine or the use of SPGR-based sequences could also improve IQ.


Academic Radiology | 2017

One-Year Follow-up Study Detects Myocardial Changes with Cardiovascular Magnetic Resonance Tagging in Active Rheumatoid Arthritis

Lauri Lehmonen; Aino-Maija Vuorinen; Riitta Koivuniemi; Marjatta Leirisalo-Repo; Miia Holmström; Sari Kivistö; Touko Kaasalainen

RATIONALE AND OBJECTIVES To evaluate the effects of 1 year of medical treatment on myocardial function in active rheumatoid arthritis (RA). MATERIALS AND METHODS Thirty-nine female patients with RA without any known cardiovascular disease underwent a cardiovascular magnetic resonance (CMR) examination before and after 1 year of antirheumatic treatment. The population comprised untreated active early RA (ERA) and chronic RA patients, who were grouped accordingly. The CMR protocol included volumetric determinations, late gadolinium enhancement imaging, myocardial tagging, and native T1 mapping. DAS28-CRP disease activity scores were calculated before and after the treatment. RESULTS Results are reported as median (quartile 1-quartile 3). Time to peak diastolic filling rate improved in ERA (495 [443-561] ms vs 441 [340-518] ms, P = .018). Peak diastolic mean mid short-axis circumferential strain rate of all six segments was improved (82 [74-91] %/s vs 91 [77-100] %/s, P = .05), particularly in the anterior segment (82 [63-98] %/s vs 86 [77-109] %/s, P = .013). DAS28-CRP decreased in ERA (3.8 [3.2-4.1] vs 1.6 [1.4-2.2], P < .001). In chronic RA, no statistically significant improvement was detected. CONCLUSIONS Early treatment of active RA is important, as myocardial function detected with CMR tagging improved in ERA in parallel with decreasing inflammatory activity.


Acta Radiologica | 2018

Automated daily quality control analysis for mammography in a multi-unit imaging center

Veli-Matti Sundell; Teemu Mäkelä; Alexander Meaney; Touko Kaasalainen; Sauli Savolainen

Background The high requirements for mammography image quality necessitate a systematic quality assurance process. Digital imaging allows automation of the image quality analysis, which can potentially improve repeatability and objectivity compared to a visual evaluation made by the users. Purpose To develop an automatic image quality analysis software for daily mammography quality control in a multi-unit imaging center. Material and Methods An automated image quality analysis software using the discrete wavelet transform and multiresolution analysis was developed for the American College of Radiology accreditation phantom. The software was validated by analyzing 60 randomly selected phantom images from six mammography systems and 20 phantom images with different dose levels from one mammography system. The results were compared to a visual analysis made by four reviewers. Additionally, long-term image quality trends of a full-field digital mammography system and a computed radiography mammography system were investigated. Results The automated software produced feature detection levels comparable to visual analysis. The agreement was good in the case of fibers, while the software detected somewhat more microcalcifications and characteristic masses. Long-term follow-up via a quality assurance web portal demonstrated the feasibility of using the software for monitoring the performance of mammography systems in a multi-unit imaging center. Conclusion Automated image quality analysis enables monitoring the performance of digital mammography systems in an efficient, centralized manner.


Academic Radiology | 2018

The Use of Model-based Iterative Reconstruction to Optimize Chest CT Examinations for Diagnosing Lung Metastases in Patients with Sarcoma: A Phantom Study

Touko Kaasalainen; Teemu Mäkelä; Anna Kelaranta; Mika Kortesniemi

RATIONALE AND OBJECTIVES This phantom study aimed to evaluate low-dose (LD) chest computed tomography (CT) protocols using model-based iterative reconstruction (MBIR) for diagnosing lung metastases in patients with sarcoma. MATERIALS AND METHODS An adult female anthropomorphic phantom was scanned with a 64-slice CT using four LD protocols and a standard-dose protocol. Absorbed organ doses were measured with 10 metal-oxide-semiconductor field-effect transistor dosimeters. Furthermore, Monte Carlo simulations were performed to estimate organ and effective doses. Image quality in terms of image noise, contrast, and resolution was measured from the CT images reconstructed with conventional filtered back projection, adaptive statistical iterative reconstruction, and MBIR algorithms. All the results were compared to the performance of the standard-dose protocol. RESULTS Mean absorbed organ and effective doses were reduced by approximately 95% with the LD protocol (100-kVp tube voltage and a fixed 10-mA tube current) compared to the standard-dose protocol (120-kVp tube voltage and tube current modulation) while yielding an acceptable image quality for diagnosing round-shaped lung metastases. The effective doses ranged from 0.16 to 2.83 mSv in the studied protocols. The image noise, contrast, and resolution were maintained or improved when comparing the image quality of LD protocols using MBIR to the performance of the standard-dose chest CT protocol using filtered back projection. The small round-shaped lung metastases were delineated at levels comparable to the used protocols. CONCLUSIONS Radiation exposure in patients can be reduced significantly by using LD chest CT protocols and MBIR algorithm while maintaining image quality for detecting round-shaped lung metastases.

Collaboration


Dive into the Touko Kaasalainen's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge