Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Tsuyoshi Fujikawa is active.

Publication


Featured researches published by Tsuyoshi Fujikawa.


Medical Physics | 1989

Basic imaging properties of a computed radiographic system with photostimulable phosphors

Hiroshi Fujita; Katsuhiko Ueda; Junji Morishita; Tsuyoshi Fujikawa; Akiyoshi Ohtsuka; Tokugi Sai

We measured the characteristic curve, modulation transfer function (MTF), and the Wiener spectrum of a commercially available computed radiographic (CR) system with photostimulable phosphor plate (imaging plate, IP). The characteristic curve (system response) obtained by an inverse-square x-ray sensitometry showed a wide dynamic range (order of 10(3) in maximum). The slit technique was employed to determine the MTFs, such as IP MTF, presampling MTF including the unsharpness of the detector (IP) and the blurring effect of the sampling aperture, and laser-printer MTF. It was found that the MTF of the standard type of IP was comparable to that of medium-speed screen/film systems. The noticeable degradation of resolution in our CR system, however, occurred at the stage of image data sampling: the presampling MTF was inferior to the IP MTF due to the effect of the scattering and resultant spreading of the incidence laser beam and the emitted luminescence. The noise was characterized by means of digital Wiener spectrum using uniformly exposed noise data. Exposure ranges could be separated into different sections depending upon the noise sources, such as quantum mottle at low exposure and system structure noise at high exposure.


Medical Imaging III: Image Formation | 1989

Resolution Properties Of A Computed Radiographic System

Hiroshi Fujita; Junji Morishita; Katsuhiko Ueda; Du-Yih Tsai; Akiyoshi Ohtsuka; Tsuyoshi Fujikawa

The analysis of spatial-resolution properties in terms of the modulation transfer function (MTF) has been presented in a computed radiographic (CR) system (FCR-101) with the photostimulable-phosphor plate (imaging plate, IP). The newly devised method of determining the presampling MTF which includes the x-ray detector (IP) unsharpness and the unsharpness of the sampling aperture is described in which an image of a slightly-angulated lead slit relative to a horizontal or vertical direction is employed. The IP MTFs as an analog MTF in the system, the presampling MTFs for different types of IPs, different sampling distances, different versions of IPs, simultaneous multisection tomography and magnification radiography, and the laser-printer MTFs as display MTF are measured and shown. The effective sampling aperture MTFs calculated indicate that the noticeable degradation of resolution occurs at the stage of image data sampling. The usefulness of the magnification technique for mammography and bone radiography is demonstrated. It is shown that both of the digital MTF and the overall MTF are difficult to use for general purpose due to the aliasing artifacts. The effect of glare on the contrast is also characterized by lead-disk method. The glare fraction is found to be approximately 6.5%.


Japanese Journal of Radiological Technology | 1990

BASIC IMAGING PROPERTIES IN A COMPUTED RADIOGRAPHY SYSTEM

Junji Morishita; Hiroshi Fujita; Akiyoshi Ohtsuka; Katsuhiko Ueda; Tsuyoshi Fujikawa; Shuichi Yamauchi; Sadamitsu Nishihara; Masahiro Hashida; Ryuji Kanzaki; Kazumi Kanai; Sadato Tanaka; Takashi Nakanishi


Japanese Journal of Radiological Technology | 1995

COMPARISON OF IMAGE QUALITY BETWEE HIGH SENSITIVITY IMAGING PLATE WITH FREQUENCY PROCESSING AND LOW SENSITIVITY IMAGING PLATE

Sadamitsu Nishihara; Keiko Ohmura; Akiyoshi Ohtsuka; Katsuhiko Ueda; Syuichi Yamauchi; Ken-Ichi Yoshida; Tsuyoshi Fujikawa; Takashi Nakanishi


Japanese Journal of Radiological Technology | 1995

PATIENT DOSE REDUCTION USING A HIGH-SENSITIVITY IMAGING PLATE WITH FREQUENCY PROCESSING

Sadamitsu Nishihara; Keiko Ohmura; Akiyoshi Ohtsuka; Ken-Ichi Yoshida; Syuichi Yamauchi; Katsuhiko Ueda; Tsuyoshi Fujikawa; Takashi Nakanishi


Japanese Journal of Radiological Technology | 1994

137. Basic Image Properties of New Type Imaging Plate (-V Series-)

Sadamitsu Nishihara; Keiko Ohmura; A. Ohtuka; Katsuhiko Ueda; Syuichi Yamauchi; Kazumi Kanai; Ken-Ichi Yoshida; Hiromi Nagano; Tsuyoshi Fujikawa


Japanese Journal of Radiological Technology | 1993

165. Comparison of Image Quality of Imaging Plate in CR System (Part 2) : HRIII_N and STIII_N

Sadamitsu Nishihara; Keiko Ohmura; Akiyoshi Ohtsuka; Katsuhiko Ueda; Syuichi Yamauchi; Kazumi Kanai; Ken-Ichi Yoshida; Tsuyoshi Fujikawa


Japanese Journal of Radiological Technology | 1992

16. CR における直線断層写真の障害陰影除去フィルタの臨床評価(CR-1 胸部)

Katsuhiko Ueda; Akiyoshi Ohtsuka; Takashi Nakanishi; Hiroshi Fujita; Tsuyoshi Fujikawa


Japanese Journal of Radiological Technology | 1992

121. Comparison of Image Quality of Imaging Plate in CR System : HR and Unsharp Masked ST

Sadamitsu Nishihara; Keiko Ohmura; Katsuhiko Ueda; Syuichi Yamauchi; Kazumi Kanai; Ken-Ichi Yoshida; Akiyoshi Ohtsuka; Tsuyoshi Fujikawa


Japanese Journal of Radiological Technology | 1992

MEASUREMENTS OF WIENER SPECTRA OF LASER PRINTER IN A COMPUTED RADIOGRAPHY

Syuichi Yamauchi; Hiroshi Fujita; Junji Morishita; Tsuyoshi Fujikawa; Katsuhiko Ueda; Sadamitsu Nishihara; Akiyoshi Ohtsuka

Collaboration


Dive into the Tsuyoshi Fujikawa's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge